1.

Background and Purpose

Although the relevance of understanding spinal kinematics during functional activities in patients with complex spinal deformities is undisputed among researchers and clinicians, evidence using skin marker-based motion capture systems is still limited to a handful of studies, mostly conducted on healthy subjects and using non-validated marker configurations. The current study therefore aimed to explore the validity of a previously developed enhanced trunk marker set for the static measurement of spinal curvature angles in patients with main thoracic adolescent idiopathic scoliosis. In addition, the impact of inaccurate marker placement on curvature angle calculation was investigated.

Methods

Ten patients (Cobb angle: 44.4±17.7 degrees) were equipped with radio-opaque markers on selected spinous processes and underwent a standard biplanar radiographic examination. Subsequently, radio-opaque markers were replaced with retro-reflective markers and the patients were measured statically using a Vicon motion capture system. Thoracolumbar / lumbar and thoracic curvature angles in the sagittal and frontal planes were calculated based on the centers of area of the vertebral bodies and radio-opaque markers as well as the three-dimensional position of the retro-reflective markers. To investigate curvature angle estimation accuracy, linear regression analyses among the respective parameters were used. The impact of inaccurate marker placement was explored using linear regression analyses among the radio-opaque marker- and spinous process-derived curvature angles.

Results and Discussion

The results demonstrate that curvatures angles in the sagittal plane can be measured with reasonable accuracy, whereas in the frontal plane, angles were systematically underestimated, mainly due to the positional and structural deformities of the scoliotic vertebrae. Inaccuracy of marker placement had a greater impact on thoracolumbar / lumbar than thoracic curvature angles. It is suggested that spinal curvature measurements are included in marker-based clinical gait analysis protocols in order to enable a deeper understanding of the biomechanical behavior of the healthy and pathological spine in dynamic situations as well as to comprehensively evaluate treatment effects.  相似文献   

2.
Most clinical gait analyses are conducted using motion capture systems which track retro-reflective markers that are placed on key landmarks of the participants. An alternative to a three-dimensional (3D) motion capture, marker-based, optical camera system may be a marker-less video-based tracking system. The aim of our study was to investigate the efficacy of the use of a marker-less tracking system in the calculation of 3D joint angles for possible use in clinical gait analysis. Ten participants walked and jogged on a treadmill and their kinematic data were captured with a marker and marker-less tracking system simultaneously. The hip, knee and ankle angles in the frontal, sagittal and transverse planes were computed. Root Mean Square differences (RMSdiff) between corresponding angles for each participant’s support phase were calculated and averaged to derive the mean within-subject RMSdiff. These within-subject means were averaged to obtain the mean between-subject RMSdiff for the relevant joint angles in the two gait conditions (walking and jogging). The RMSdiff between the two tracking systems was less than 1° for all rotations of the three joint angles of the hip and knee. However, there were slightly larger differences in the ankle joint angles. The results of this study suggest a potential application in gait analysis in clinical settings where observations of anatomical motions may provide meaningful feedback.  相似文献   

3.
Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.  相似文献   

4.
Inverse dynamics are the cornerstone of biomechanical assessments to calculate knee moments during walking. In knee osteoarthritis, these outcomes have been used to understand knee pathomechanics, but the complexity of an inverse dynamic model may limit the uptake of joint moments in some clinical and research structures. The objective was to determine whether discrete features of the sagittal and frontal plane knee moments calculated using inverse dynamics compare to knee moments calculated using a cross product function. Knee moments from 74 people with moderate knee osteoarthritis were assessed after ambulating at a self-selected speed on an instrumented dual belt treadmill. Standardized procedures were used for surface marker placement, gait speed determination and data processing. Net external frontal and sagittal plane knee moments were calculated using inverse dynamics and the three-dimensional position of the knee joint center with respect to the center of pressure was crossed with the three-dimensional ground reaction forces in the cross product function. Correlations were high between outcomes of the moment calculations (r > 0.9) and for peak knee adduction moment, knee adduction moment impulse and difference between peak flexion and extension moments, the cross product function resulted in absolute values less than 10% of those calculated using inverse dynamics in this treadmill walking environment. This computational solution may allow the integration of knee moment calculations to understand knee osteoarthritis gait without data collection or computational complexity.  相似文献   

5.
Increased femoral antetorsion leads to several gait deviations, and amongst others, an increased knee flexion was reported in mid and terminal stance. Therefore, the purpose of this retrospective study was to identify gait deviations caused by increased femoral antetorsion and to perform subgroup analyses based on sagittal knee kinematics. Patients with isolated, CT confirmed increased femoral antetorsion (n = 42) and age-matched typically developing children (TDC, n = 17) were included in this study. Patients were referred to gait analysis because of gait abnormalities going along with an increased femoral antetorsion ≥30°. Kinematic and kinetic data were recorded during 3D gait analysis and three valid gait cycles were analyzed. Principal component (PC) analysis was used to achieve data transformation. A linear mixed model was used to estimate the group effect of PC-scores of retained PCs explaining 90% of the cumulative variance. Group effects of PC-scores revealed that patients walked with more flexed hips and greater anterior pelvic tilt throughout the gait cycle. Knee flexion was increased in patients during mid and terminal stance. Increased frontal plane knee and hip joint moments were found for patients compared to TDC. Furthermore, dividing patients into two subgroups based on their sagittal knee kinematics showed that kinematic gait deviations were more pronounced in patients with higher femoral antetorsion, while deviations in joint moments were more pronounced in patients with lower femoral antetorsion. Increased femoral antetorsion showed alterations in all lower limb joints and may be not only a cosmetic problem. Therefore, 3D gait analysis should be used for clinical management and operative treatment should be considered depending on severity of gait deviations.  相似文献   

6.
Tendon orientations in knee models are often taken from cadaver studies. The aim of this study was to investigate the effect of muscle activation on tendon orientation in vivo. Magnetic resonance imaging (MRI) images of the knee were made during relaxation and isometric knee extensions and flexions with 0 degrees , 15 degrees and 30 degrees of knee joint flexion. For six tendons, the orientation angles in sagittal and frontal plane were calculated. In the sagittal plane, muscle activation pulled the patellar tendon to a more vertical orientation and the semitendinosus and sartorius tendons to a more posterior orientation. In the frontal plane, the semitendinosus had a less lateral orientation, the biceps femoris a more medial orientation and the patellar tendon less medial orientation in loaded compared to unloaded conditions. The knee joint angle also influenced the tendon orientations. In the sagittal plane, the patellar tendon had a more anterior orientation near full extension and the biceps femoris had an anterior orientation with 0 degrees and 15 degrees flexions and neutral with 30 degrees flexions. Within 0 degrees to 30 degrees of flexion, the biceps femoris cannot produce a posterior shear force and the anterior angle of the patellar tendon is always larger than the hamstring tendons. Therefore, co-contraction of the hamstring and quadriceps is unlikely to reduce anterior shear forces in knee angles up to 30 degrees . Finally, inter-individual variation in tendon angles was large. This suggests that the amount of shear force produced and the potential to counteract shear forces by co-contraction is subject-specific.  相似文献   

7.
Researchers conduct gait analyses utilizing both overground and treadmill modes of running. Previous studies comparing these modes analyzed discrete variables. Recently, techniques involving quantitative pattern analysis have assessed kinematic curve similarity in gait. Therefore, the purpose of this study was to compare hip, knee and rearfoot 3-D kinematics between overground and treadmill running using quantitative kinematic curve analysis. Twenty runners ran at 3.35 m/s ± 5% during treadmill and overground conditions while right lower extremity kinematics were recorded. Kinematics of the hip, knee and rearfoot at footstrike and peak were compared using intraclass correlation coefficients. Kinematic curves during stance phase were compared using the trend symmetry method within each subject. The overall average trend symmetry was high, 0.94 (1.0 is perfect symmetry) between running modes. The transverse plane and knee frontal plane exhibited lower similarity (0.86-0.90). Other than a 4.5 degree reduction in rearfoot dorsiflexion at footstrike during treadmill running, all differences were ≤1.5 degrees. 17/18 discrete variables exhibited modest correlations (>0.6) and 8/18 exhibited strong correlations (>0.8). In conclusion, overground and treadmill running kinematic curves were generally similar when averaged across subjects. Although some subjects exhibited differences in transverse plane curves, overall, treadmill running was representative of overground running for most subjects.  相似文献   

8.
Understanding the potential causes of both reduced gait speed and compensatory frontal plane kinematics during walking in individuals post-stroke may be useful in developing effective rehabilitation strategies. Multiple linear regression analysis was used to select the combination of paretic limb impairments (frontal and sagittal plane hip strength, sagittal plane knee and ankle strength, and multi-joint knee/hip torque coupling) which best estimate gait speed and compensatory pelvic obliquity velocities at toeoff. Compensatory behaviors were defined as deviations from control subjects’ values. The gait speed model (n=18; p=0.003) revealed that greater hip abduction strength and multi-joint coupling of sagittal plane knee and frontal plane hip torques were associated with decreased velocity; however, gait speed was positively associated with paretic hip extension strength. Multi-joint coupling was the most influential predictor of gait speed. The second model (n=15; p<0.001) revealed that multi-joint coupling was associated with increased compensatory pelvic movement at toeoff; while hip extension and flexion and knee flexion strength were associated with reduced frontal plane pelvic compensations. In this case, hip extension strength had the greatest influence on pelvic behavior. The analyses revealed that different yet overlapping sets of single joint strength and multi-joint coupling measures were associated with gait speed and compensatory pelvic behavior during walking post-stroke. These findings provide insight regarding the potential impact of targeted rehabilitation paradigms on improving speed and compensatory kinematics following stroke.  相似文献   

9.
The foot progression angle (FPA) influences knee loading during gait, but its determinants are unclear. The purpose of this study was to compare FPA between males and females and also examine the association between lower extremity kinematics during gait, hip strength, and the FPA. 25 males and 25 females completed 5 gait trials while FPA and frontal and transverse plane hip and knee angles were calculated from the dominant limb during the foot flat portion of stance. Hip extensor/flexor, abductor/adductor, and internal/external rotator strength were evaluated using maximum voluntary isometric contractions. One-way MANOVAs compared gait and strength outcomes. Stepwise regression assessed the association between FPA, and MVIC and kinematics after accounting for speed in males and females. There was no difference in FPA between sexes (p > 0.05), but females had greater frontal and transverse plane hip angles compared with males (all p < 0.05). Greater hip abduction (p = 0.02) strength was associated with greater FPA, but only in males. In males, greater hip abductor strength may contribute to a more neutral position of the foot during gait, which could help maintain an equal knee loading distribution. Our results suggest that there are sex specific control strategies to achieve a similar FPA during gait.  相似文献   

10.
A three-dimensional kinematic and dynamic model of the lower limb   总被引:7,自引:0,他引:7  
A model describing the kinematics and dynamics of the lower limb is presented. The lower limb is modeled as a sequence of four rigid links connected by three universal rotary joints representing the hip, knee and ankle joints. Each joint is modeled as a sequence of three single axis rotational joints thus ascribing to the lower limb a total of 12 degrees of freedom. A method is described to measure the gait variables so that all nine angles can be computed based on the positions of nine markers placed on the subject during a gait study. The gait variables are then used in an iterative Newton-Euler formulation to compute the moments exerted about the axes of each joint during gait.  相似文献   

11.
In gait analysis, the concepts of Euler and helical (screw) angles are used to define the three-dimensional relative joint angular motion of lower extremities. Reliable estimation of joint angular motion depends on the accurate definition and construction of embedded axes within each body segment. In this paper, using sensitivity analysis, we quantify the effects of uncertainties in the definition and construction of embedded axes on the estimation of joint angular motion during gait. Using representative hip and knee motion data from normal subjects and cerebral palsy patients, the flexion-extension axis is analytically perturbed +/- 15 degrees in 5 degrees steps from a reference position, and the joint angles are recomputed for both Euler and helical angle definitions. For the Euler model, hip and knee flexion angles are relatively unaffected while the ab/adduction and rotation angles are significantly affected throughout the gait cycle. An error of 15 degrees in the definition of flexion-extension axis gives rise to maximum errors of 8 and 12 degrees for the ab/adduction angle, and 10-15 degrees for the rotation angles at the hip and knee, respectively. Furthermore, the magnitude of errors in ab/adduction and rotation angles are a function of the flexion angle. The errors for the ab/adduction angles increase with increasing flexion angle and for the rotation angle, decrease with increasing flexion angle. In cerebral palsy patients with flexed knee pattern of gait, this will result in distorted estimation of ab/adduction and rotation. For the helical model, similar results are obtained for the helical angle and associated direction cosines.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
A primary source of measurement error in gait analysis is soft-tissue artefact. Hip and knee angle measurements, regularly used in clinical decision-making, are particularly prone to pervasive soft tissue on the femur. However, despite several studies of thigh marker artefact it remains unclear how lateral thigh marker height affects results using variants of the Conventional Gait Model. We compared Vicon Plug-in Gait hip and knee angle estimates during gait using a proximal and distal thigh marker placement for ten healthy subjects. Knee axes were estimated by optimizing thigh rotation offsets to minimize knee varus-valgus range during gait. Relative to the distal marker, the proximal marker produced 37% less varus-valgus range and 50% less hip rotation range (p < 0.001), suggesting that it produced less soft-tissue artefact in knee axis estimates. The thigh markers also produced different secondary effects on the knee centre estimate. Using whole gait cycle optimization, the distal marker showed greater minimum and maximum knee flexion (by 6° and 2° respectively) resulting in a 4° reduction in range. Mid-stance optimization reduced distal marker knee flexion by 5° throughout, but proximal marker results were negligibly affected. Based on an analysis of the Plug-in Gait knee axis definition, we show that the proximal marker reduced sensitivity to soft-tissue artefact by decreasing collinearity between the points defining the femoral frontal plane and reducing anteroposterior movement between the knee and thigh markers. This study suggests that a proximal thigh marker may be preferable when performing gait analysis using the Plug-in Gait model.  相似文献   

13.
As a cost-effective, clinician-friendly gait assessment tool, the Kinect v2 sensor may be effective for assessing lower extremity joint kinematics. This study aims to examine the validity of time series kinematical data as measured by the Kinect v2 on a flatland for gait assessment. In this study, 51 healthy subjects walked on a flatland while kinematic data were extracted concurrently using the Kinect and Vicon systems. The kinematic outcomes comprised the hip and knee joint angles. Parallel translation of Kinect data obtained throughout the gait cycle was performed to minimize the differences between the Kinect and Vicon data. The ensemble curves of the hip and knee joint angles were compared to investigate whether the Kinect sensor can consistently and accurately assess lower extremity joint motion throughout the gait cycle. Relative consistency was assessed using Pearson correlation coefficients. Joint angles measured by the Kinect v2 followed the trend of the trajectories made by the Vicon data in both the hip and knee joints in the sagittal plane. The trajectories of the hip and knee joint angles in the frontal plane differed between the Kinect and Vicon data. We observed moderate to high correlation coefficients of 20%–60% of the gait cycle, and the largest difference between Kinect and Vicon data was 4.2°. Kinect v2 time series kinematical data obtained on the flatland are validated if the appropriate correction procedures are performed. Future studies are warranted to examine the reproducibility and systematic bias of the Kinect v2.  相似文献   

14.
We investigated the simple and multivariate associations between knee pain and gait biomechanics. 279 patients with medial knee osteoarthritis (OA) and discordant changes in pain between limbs after walking completed bilateral three-dimensional gait analysis. For each limb, patients rated their pain before and after a 6-min walk and the change in pain was recorded as an increase (≥1 points) or not (≤0 points). Among paired limbs, the simple and multivariate associations between an increase in pain and the external moments in each orthogonal plane were evaluated using conditional logistic regression. The analyses were then repeated for knee angles. Univariate analyses demonstrated associations in each plane that varied in both magnitude and direction, with larger associations for the knee moments [Odds Ratio (95% confidence interval) = first peak adduction moment: 2.80 (2.02, 3.88), second peak adduction moment: 2.36 (1.73, 3.24), adduction impulse: 6.65 (3.50, 12.62), flexion moment: 0.46 (0.36, 0.60), extension moment: 0.56 (0.44, 0.71), internal rotation moment: 7.54 (3.32, 17.13), external rotation moment: 0.001 (0.00, 0.04)]. Multivariate analyses with backward elimination resulted in a model including only the adduction impulse [5.35 (2.51, 11.42)], flexion moment [0.32 (0.22, 0.46)] and extension moment [0.28 (0.19, 0.42)]. The varus, flexion and extension angles were included in the final multivariate model for the knee angles. When between-person confounding is lessened by comparing limbs within patients, there are strong independent associations between knee pain and multiple external knee moments that vary in magnitude and direction. While controlling for other knee moments, a greater adduction impulse and lower flexion and extension moments were independently associated with greater odds of an increase in pain.  相似文献   

15.
Hip joint moments are an important parameter in the biomechanical evaluation of orthopaedic surgery. Joint moments are generally calculated using scaled generic musculoskeletal models. However, due to anatomical variability or pathology, such models may differ from the patient's anatomy, calling into question the accuracy of the resulting joint moments. This study aimed to quantify the potential joint moment errors caused by geometrical inaccuracies in scaled models, during gait, for eight test subjects. For comparison, a semi-automatic computed tomography (CT)-based workflow was introduced to create models with subject-specific joint locations and inertial parameters. 3D surface models of the femora and hemipelves were created by segmentation and the hip joint centres and knee axes were located in these models. The scaled models systematically located the hip joint centre (HJC) up to 33.6 mm too inferiorly. As a consequence, significant and substantial peak hip extension and abduction moment differences were recorded, with, respectively, up to 23.1% and 15.8% higher values in the image-based models. These findings reaffirm the importance of accurate HJC estimation, which may be achieved using CT- or radiography-based subject-specific modelling. However, obesity-related gait analysis marker placement errors may have influenced these results and more research is needed to overcome these artefacts.  相似文献   

16.
As biomechanical research evolves, a continuing challenge is the standardization of data collection and analysis techniques. In gait analysis, placement of markers to construct an anatomical model has been identified as the single greatest source of error; however, there is currently no standardized approach to quantifying these errors. The current study applies morphometric methods, including a generalized Procrustes analysis (GPA) and a nearest neighbour comparison to quantify discrepancies in marker placement, with the goal of improving reliability in gait analysis. An extensive data-set collected by an Expert (n = 340) was used to evaluate marker placements performed by a Novice (n = 55). Variances identified through principal component analysis were used to create a modified GPA to transform anatomical data, and scaled coordinates from the Novice data-set were then scored against the Expert subset. The results showed quantitative differences in marker placement, suggesting that, although training improved consistency, systematic biases remained.  相似文献   

17.
Motion of the knee after condylar resurfacing--an in vivo study.   总被引:3,自引:0,他引:3  
The purpose of this study was determine the amounts of rotation and displacement occurring in a relatively unconstrained condylar replacement knee, and to compare the motion with a matched group of normal knees. The motion was measured using an electromagnetic device, the 3-Space Tracker, for various common activities, for 25 normal volunteers and 25 total knee patients. The main variables studied were internal-external rotation of the tibia about its long axis and anterior-posterior displacement of the femoral origin with respect to the tibia, as a function of flexion angle or per cent of gait cycle. The motion of the total knees was very similar to that of the normals. For sitting, standing and free-swing, the knee rotated internally by 5-10 degrees and the femur displaced posteriorly by 9-14 mm, as the knee was flexed from 0 to 90 degrees. For walking and going upstairs and downstairs the absolute values of the rotations and displacements were similar to the above. However, the mean values of rotation were less due to greater variation in the rotation patterns, due probably to the increased laxity of the knee during the swing phases. From these data, taking the mean motions and one standard deviation (S.D.), it is suggested that a knee prosthesis should allow a rotation from minus to plus 12 degrees (a total range of 24 degrees) and an anterior-posterior displacement of 13 mm. It is suggested that these motions be subject to progressive restraint from the neutral position in the manner of the natural knee.  相似文献   

18.
The primary method to model ankle motion during inverse dynamic calculations of the lower limb is through the use of skin-mounted markers, with the foot modeled as a rigid segment. Motion of the foot is often tracked via the use of a marker cluster triad on either the dorsum, or heel, of the foot/shoe. The purpose of this investigation was to evaluate differences in calculated lower extremity dynamics during the stance phase of gait between these two tracking techniques. In an analysis of 7 subjects, it was found that sagittal ankle angles and sagittal ankle, hip and knee moments were strongly correlated between the two conditions, however, there was a significant difference in peak ankle plantar flexion and dorsiflexion angles. Frontal ankle angles were only moderately correlated and there was a significant difference in peak ankle eversion and inversion, resulting in moderate correlations in frontal plane moments and a significant difference in peak hip adductor moments. We demonstrate that the technique used to track the foot is an important consideration in interpreting lower extremity dynamics for clinical and research purposes.  相似文献   

19.
This paper presents a control approach for bounding gait of quadruped robots by applying the concept of Virtual Constraints (VCs).A VC is a relative motion relation between two related joints imposed to the robots in terms of a specified gait,which can drive the robot to run with desired gait.To determine VCs for highly dynamic bounding gait,the limit cycle motions of the passive dynamic model of bounding gait are analyzed.The leg length and hip/shoulder angle trajectories corresponding to the limit cycles are parameterized by leg angles using 4 th-order polynomials.In order to track the calculated periodic motions,the polynomials are imposed on the robot as virtual motion constraints by a high-level state machine controller.A bounding speed feedback strategy is introduced to stabilize the robot running speed and enhance the stability.The control approach was applied to a newly designed lightweight bioinspired quadruped robot,AgiDog.The experimental results demonstrate that the robot can bound at a frequency up to 5 Hz and bound at a maximum speed of 1.2 m·s-1 in sagittal plane with a Froude number approximating to 1.  相似文献   

20.
Although a number of approaches have attempted to model knee kinematics, rarely have they been validated against in vivo data in a larger subject cohort. Here, we assess the feasibility of four-bar linkage mechanisms in addressing knee kinematics and propose a new approach that is capable of accounting for lengthening characteristics of the ligaments, including possible laxity, as well as the internal/external rotation of the joint. MR scans of the knee joints of 12 healthy volunteers were taken at flexion angles of 0 degrees , 30 degrees and 90 degrees under both passive and active muscle conditions. By reconstructing the surfaces at each position, the accuracy of the four-bar linkage mechanism was assessed for every possible combination of points within each cruciate ligament attachment area. The specific set of parameters that minimized the deviation between the predictions and the in vivo pose was derived, producing a mean error of 1.8 and 2.5 on the medial and 1.7 and 2.4mm on the lateral side at 30 degrees and 90 degrees flexion, respectively, for passive motion, significantly improving on the models that did not consider internal/external rotation. For active flexion, mean medial errors were 3.3 and 4.7 mm and lateral errors 3.4 and 4.8 mm. Using this best parameter set, a generic predictive model was created and assessed against the known in vivo positions, producing a maximum average error of 4.9 mm at 90 degrees flexion. The accuracy achieved shows that kinematics may be accurately reconstructed for subject specific musculoskeletal models to allow a better understanding of the load distribution within the knee.  相似文献   