首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
A new two-step filtration protocol followed by a real-time PCR assay based on SYBR green I detection was developed to directly quantitate salmonellae in two types of biological samples: i.e., chicken rinse and spent irrigation water. Four prefiltration filters, one type of final filter, and six protocols for recovery of salmonellae from the final filter were evaluated to identify an effective filtration protocol. This method was then combined with a real-time PCR assay based on detection of the invA gene. The best results were obtained by subsequent filtration of 100 ml of chicken rinse or 100 ml of spent irrigation water through filters with pore diameters of >40 μm to remove large particles and of 0.22 μm to recover the Salmonella cells. After this, the Salmonella cells were removed from the filter by vortexing in 1 ml of physiological saline, and this sample was then subjected to real-time quantitative PCR. The whole procedure could be completed within 3 h from sampling to quantitation, and cell numbers as low as 7.5 × 102 CFU per 100-ml sample could be quantified. Below this limit, qualitative detection of concentrations as low as 2.2 CFU/100 ml sample was possible on occasion. This study has contributed to the development of a simple, rapid, and reliable method for quantitation of salmonellae in food without the need for sample enrichment or DNA extraction.  相似文献   

2.
A microplate assay for the rapid quantitation of adenovirus DNA has been developed using the fluorescent dye PicoGreen, which selectively binds double-stranded DNA. The method was first applied to extracted adenoviral DNA and then extended to samples of intact, purified adenovirus after lysis of the viral capsid with the ionic detergent SDS. Utilizing the stoichiometric relationship between adenovirus DNA and intact particles, a physical particle count of intact virus is then derived for the sample. This PicoGreen-based assay has excellent reproducibility, linearity, and sensitivity. In its present form, this assay has a limit of quantitation of 10.3 ng/ml viral DNA, predicted to correspond to 2.6 x 10(8) virus particles/ml. This procedure was compared to a widely utilized spectroscopic method, in which samples are lysed with SDS and absorbance is read at 260 nm, and found to be 10- to 20-fold more sensitive. The dye binding assay also uses considerably less sample volume (<20%) than that needed for the spectroscopic method. Particle count values generated by the PicoGreen procedure are consistently lower (typically 1.5- to 2-fold) than this spectroscopic method. The applications and limitations of this method in the analysis of adenovirus samples are discussed.  相似文献   

3.
The work described in this paper represents an improvement over a previously published method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) in human urine by solid phase extraction on a molecularly imprinted polymer column coupled with HPLC and -MS/MS detection. The influence of ion suppression due to sample matrix effect was evaluated, and found to influence the response of NNAL. By changing the liquid chromatography conditions, the response for this method was enhanced approximately 25-fold through avoidance of ionization suppression that was found with a previously published method and sample throughput has been improved. The dynamic range of the assay extends from 20 to 2500 pg/mL with a mean r2 > 0.998. The lower limit of quantitation for the assay was 20 pg/mL despite the use of an inherently lower sensitivity instrument. The method was validated according to current FDA guidelines for bioanalytical method validations.  相似文献   

4.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

5.
Dried blood spots (DBSs) technology was evaluated in an assay for the quantitation of dextromethorphan (DM) and its metabolite, dextrorphan (DT), in human whole blood using high performance liquid chromatography with tandem mass spectrometry method (LC–MS/MS). Both the parent drug and metabolite were spiked in the blood matrix and subsequently allowed to dry on a specimen collection card. The dried blood spots were removed using a manual punch and then extracted into methyl tert-butyl ether (MTBE). The organic supernatant was transferred and evaporated and the residue was reconstituted in 20% acetonitrile. The overall method recovery of DM and DT was 87.8% and 95.4%, respectively. The assay was linear over the concentration range of 0.2–200 ng/mL for both analytes. Several factors that potentially affect DBS assay quantitation were investigated, such as punch size, DBS sample punch-out location, and the volume of the blood sample pipetted on the specimen collection cards. The study determined that punch size does not affect assay quantitation accuracy. Indeed, a larger punch size increases the sensitivity due to the larger sampled blood spots. Sampling from different location on the specimen collection cards shows no significant variation for both drugs. The study also shows that acceptable results can be achieved with some variation of the sample volume, which allows a simple blood sampling procedure at the test sites. To achieve the similar lower limit of quantitation (LLOQ) as the plasma assay, several blood spots at the same concentration level were stacked together and extracted. Bioanalytical assays using the DBS technique are promising given the advantages of the method over the plasma assay.  相似文献   

6.
7.
An assay, based on pre-column derivatization and micro-high-performance liquid chromatography–tandem mass spectrometry, was developed for the determination of the GABAB agonist CGP 44532 in rat plasma. CGP 44532, a highly polar 3-amino-2(S)-hydroxypropylmethylphosphinic acid, presented difficulties in developing a chromatographic method for the analysis of the compound in rat plasma. Instead of analyzing the target compound directly, it was derivatized prior to separation to a 4-nitrobenzylcarbamate isopropyliden derivative. In order to reach the required quantitation limit, on-line solid-phase extraction was utilized for sample clean-up and reversed-phase micro-column high-performance liquid chromatography, for separation of the plasma samples. The separated compounds were detected by negative electrospray tandem mass spectrometry in selected reaction monitoring mode. The derivatives show good chromatographic and mass spectrometric properties and both the target compound and the internal standard, could be eluted as symmetrical peaks with good signal/noise ratio. The MS–MS detection was selective and sensitive due to the straight fragmentation pattern. After injection of 200-μl sample aliquots, the limit of quantification was 10 ng ml−1. The analytical assay is useable in the range of 10–500 ng ml−1.  相似文献   

8.
Isotope dilution analysis for the quantitation of labile compounds has been limited in applicability by the amount of sample necessary to determine specific activity. A method is described for the analysis of radiolabeled compounds which allows the direct determination of specific activity by gas chromatography. It requires the availability of the radiolabeled internal standard, as is customarily used in an isotope dilution assay, and also requires a chemically related radiolabeled compound to serve as a second internal standard. It is this second internal standard, added in known amounts, that permits quantitation of the gas chromatography. The method is illustrated by assaying indole-3-acetic acid in plant extracts using [14C]indole-3-acetic acid as the internal standard and adding [14C]indole-3-butyric acid as the second internal standard for quantitation of the gas chromatographic procedures. Used with a nitrogen-specific thermionic detector the method is selective and is sensitive at the nanogram level. The synthesis of [2-ring-14C]indole-3-butyric acid is also described.  相似文献   

9.
Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20–1000 pg mL−1, and its limit of quantitation was 20 pg mL−1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.  相似文献   

10.
Diphenylmethoxyacetic acid (DPMA) is a major metabolite of diphenhydramine in monkeys, dogs, and humans. The metabolic fate of diphenhydramine (DPHM) in sheep is not yet well understood; however, preliminary studies have demonstrated the presence of DPMA in the plasma and urine of sheep following an intravenous bolus of DPHM. Our current studies employ the simultaneous intravenous co-administration of DPHM and the stable isotope analog of DPHM to investigate the pharmacokinetics of DPHM in sheep. In these studies, in order to investigate the pharmacokinetics of the DPMA metabolite, measurement of both unlabeled and stable-isotope labeled DPMA is required. Thus, a stable isotope analog of DPMA ([2H10]DPMA) was synthesized, characterized, and purified for use as an analytical standard. The quantitative method for the gas chromatography—electron-impact mass spectrometry (GC—EI-MS) analysis of DPMA and [2H10]DPMA used a single step liquid-liquid extraction procedure using toluene for sample cleanup. The samples were derivatized with N-methyl-N-(tert.-butyldimethylsilyl) trifluoroacetamide. A 1.0-μl aliquot of the prepared sample was injected into the GC-MS system and quantitated using selected-ion monitoring (SIM). One ion was monitored for each compound, namely, m/z 165 for the internal standard diphenylacetic acid, m/z 183 for DPMA, and m/z 177 for [2H10]DPMA. The ion chromatograms were free from chromatographic peaks co-eluting with the compound of interest. The calibration curve was linear from 2.5 ng/ml (limit of quantitation) to 250.0 ng/ml in both urine and plasma. The intra-day and inter-day variabilities of this assay method were within acceptable limits (below 20% at the limit of quantitation and below 10% at all other concentrations). This method was used to measure the concentration of DPMA and [2H10]DPMA in plasma and urine samples from a ewe in which equimolar amounts of DPHM and [2H10]DPHM were administered by an intravenous bolus dose via the femoral vein. DPMA appeared to persist longer in the plasma and the urine as compared to DPHM. This method is robust and reliable for the quantitation of DPMA and [2H10]DPMA in biological samples obtained from sheep (e.g. plasma and urine).  相似文献   

11.
A new two-step filtration protocol followed by a real-time PCR assay based on SYBR green I detection was developed to directly quantitate salmonellae in two types of biological samples: i.e., chicken rinse and spent irrigation water. Four prefiltration filters, one type of final filter, and six protocols for recovery of salmonellae from the final filter were evaluated to identify an effective filtration protocol. This method was then combined with a real-time PCR assay based on detection of the invA gene. The best results were obtained by subsequent filtration of 100 ml of chicken rinse or 100 ml of spent irrigation water through filters with pore diameters of >40 mum to remove large particles and of 0.22 microm to recover the Salmonella cells. After this, the Salmonella cells were removed from the filter by vortexing in 1 ml of physiological saline, and this sample was then subjected to real-time quantitative PCR. The whole procedure could be completed within 3 h from sampling to quantitation, and cell numbers as low as 7.5 x 10(2) CFU per 100-ml sample could be quantified. Below this limit, qualitative detection of concentrations as low as 2.2 CFU/100 ml sample was possible on occasion. This study has contributed to the development of a simple, rapid, and reliable method for quantitation of salmonellae in food without the need for sample enrichment or DNA extraction.  相似文献   

12.
SARS冠状病毒实时荧光RT-PCR定量检测   总被引:1,自引:0,他引:1  
为建立一种快速、准确、特异的SARS病毒RNA定量检测方法,根据复合探针荧光定量分析原理,对SARS病毒核酸进行实时荧光定量RT-PCR检测.借助计算机辅助,对SARS病毒基因靶序列以及检测引物和探针进行了优化筛选;利用体外转录SARS病毒RNA靶序列,对RT-PCR反应的镁离子浓度参数进行了优化;比较Trizol法、磁珠法、Qiagen法、煮沸法等4种方法提取RNA的检测效果,建立了样本处理方法;通过对构建的体外转录靶序列模型的检测,对本方法的灵敏度、特异性、定量线性关系、精确度等进行了评价,并通过对42例临床标本的检测对本方法的检测效果进行了评估. 通过克隆SARS病毒核酸靶序列并进行体外转录,获得了长度约1.2 kb的体外转录RNA靶序列;经优化,荧光RT-PCR反应液中的Mg2+浓度以4.0 mmol/L为最好;RNA提取方法采用磁珠法效果较好;本方法的检测灵敏度最低可达5个拷贝的体外转录RNA分子,特异性100%,Ct值的CV值小于5%.对临床确诊的42份SARS病人血清和漱口水标本的检测结果表明,该方法的检出率为79%,与荧光抗体检测法的符合率为70%.上述结果表明,该方法建立的荧光定量RT-PCR技术能够快速准确、特异、敏感地对SARS病毒核酸进行定量分析,为临床SARS冠状病毒RNA的检测提供了新的,更为有效的检测方法.  相似文献   

13.
A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4'-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak AD-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 microg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 microg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.  相似文献   

14.
Xanthomonas fragariae is a bacterium that causes angular leaf spot of strawberry. Asymptomatic infection is common and contributes to the difficulties in disease management. The aim of this study was to develop a loop-mediated isothermal amplification (LAMP) assay as an efficient method for detection of asymptomatic infections of X. fragariae. In addition, a new method of sample preparation was developed that allows sampling of a larger amount of plant tissue, hence increasing the detection rate in real-life samples. The sample preparation procedure includes an overnight incubation of strawberry tissues in phosphate-buffered saline (PBS), followed by a quick sample concentration and a boiling step to extract DNA for amplification. The detection limit of the LAMP assay was approximately 2×103 CFU/mL for pure bacteria culture and 300 CFU/mL for bacteria spiked strawberry leaf and petiole samples. LAMP provided a 2–3 fold lower detection limit than the standard qPCR assay but was faster, and more user-friendly. The LAMP assay should serve as a rapid, sensitive and cost-effective tool for detecting asymptomatic infections of X. fragariae in strawberry nursery stock and contribute to improved disease management.  相似文献   

15.
Enantiomers of salbutamol were directly separated (Rs=1.16) and quantitated at therapeutic concentrations after solid-phase extraction from human plasma and urine by normal-phase high-performance liquid chromatography on a chiral column with fluorescence detection. The assay was linear for each enantiomer between 1.25 and 500 ng ml−1 and had a minimum limit of detection of 250 pg ml−1. A 3-ml plasma or 1-ml urine sample was required for quantitation at therapeutic doses. Inter-day variation was 50% for S-(+)- and 6.5% for R-(−)-salbutamol. The assay was used to compare enantioselective disposition after single doses of racemate by the intravenous, oral and rectal routes.  相似文献   

16.
Aim: To develop and to validate a method for the quantification of Lawsonia intracellularis in porcine faeces by real‐time PCR. Methods and Results: A real‐time PCR including a calibrator based on plasmid DNA for quantification by means of ΔΔCt method was evaluated. The parameters specificity, detection limit, quantification limit, linearity, range, repeatability, precision and recovery were validated. The detection limit of the agent was 1 copy per reaction, and quantification was reliable between 101 and 107 copies per μl reaction volume. The linearity calculated by logistic regression revealed a slope of ?3·329 reflecting an efficiency of 99·7% for the assay. Moreover, it was shown that storage of samples and repetition of tests including DNA isolation by same or other investigators did not influence the outcome. Conclusion: The quantification method described herein revealed consistent results for the quantitation of L. intracellularis in porcine faeces samples. Significance and Impact of the Study: In contrast to common PCR in combination with gel electrophoresis, this validated quantification method based on real‐time PCR enhances a reliable quantification and is even more sensitive.  相似文献   

17.
This report evaluates the use of a quadrupolar ion trap for quantitation in a bioanalytical laboratory. The evaluation was accomplished with the cross-validation of an LC–MS–MS quantitative method previously validated on a triple quadrupole mass spectrometer. The method was a multi-level determination of the anti-obesity drug, orlistat, in human plasma. The method has been refined previously on a triple quadrupole instrument to provide rapid sample throughput with robust reproducibility at sub-nanogram detection limits. Optimization of the method on the ion trap required improved chromatographic separation of orlistat from interfering plasma matrix components coextracted during the initial liquid–liquid extraction of plasma samples. The ion trap produces full-scan collision-induced dissociation mass spectra containing characteristic orlistat fragment ions that are useful for quantitation. Data collection on the ion trap required a precursor ion isolation width of 3.0 Da and optimal quantitative results were obtained when three fragment ions were monitored with a 1.8 Da window for each ion. Although a direct cross-validation between the ion trap and the tandem triple quadrupole mass spectrometer was not possible, quantitative results for orlistat comparable to those obtained from the triple quadrupole instrument were achieved by the ion trap with the modified method. The limit of quantitation for orlistat in plasma on the ion trap was 0.3 ng ml−1 with a linear dynamic range of 0.3 to 10 ng ml−1. Precision and accuracy varied from 4 to 15% over the quantitation range. The overall results provide an example of the utility of an ion trap in bioanalytical work.  相似文献   

18.
目的:建立人博卡病毒(HBoV)核酸特异、快速、敏感的TaqMan探针实时定量PCR检测方法,并对临床样本进行检测。方法:比对编码HBoV非结构蛋白NP-1的基因序列,选取其保守片段设计引物和探针,建立实时荧光定量PCR检测方法,并与传统PCR方法进行比较,然后分别对两者的灵敏性、特异性、稳定性及临床样本检验的适用性等进行评价。结果:所建立的实时定量PCR检测方法可用于HBoV的特异性检测;相对于传统PCR所达到的250拷贝/反应的检测灵敏度,实时定量PCR的检测灵敏度可高达10拷贝/反应,检测范围为109~101拷贝/反应,且具有良好的特异性和重复性;初步用于76份临床呼吸道标本检测,检出阳性5例,高于普通PCR方法(3/76)。结论:建立了HBoV TaqMan探针实时定量PCR检测方法,并可用于临床鼻咽拭子样本的检测,为开展HBoV流行病学监测及早期临床诊断提供了技术手段。  相似文献   

19.
Propofol (2,6-diisopropyl phenol) is widely used for the induction and maintenance of anesthesia. Analyses of its pharmacokinetics require simple and sensitive methods for quantitation of propofol in human plasma. Previously reported HPLC and GC methods are limited by cumbersome extraction steps. We describe a novel method that combines sample preparation by solid-phase extraction (SPE) with hydrophilic-lipophilic balance cartridges and analysis with a sensitive LC-APCI-triple quadrupole mass spectrometry (MS/MS) method for better quantitation. The absolute recovery of the analyte was greater than 96%. The limit of quantification for propofol in plasma at a signal-to-noise ratio of 10 was 5 ng/ml. The precision of the assay yielded coefficients of variation ranging from 2.9 to 5.3% and an accuracies of 99-105%. Our method advances the quantitative analysis of propofol in human plasma by combining simple, rapid and efficient SPE with specific and sensitive quantitation by HPLC with APCI-MS/MS detection.  相似文献   

20.
A short reversed-phase HPLC column and a tandem mass spectrometer were used to develop a stable-isotope-dilution assay for the rapid and sensitive analysis of fluprostenol, a prostaglandin analog, in rat plasma. A Waters Symmetry ODS column (2.1×10 mm) afforded rapid isocratic elution of fluprostenol (tR=40 s) but still provided a relatively large k′ value of 4. The use of tandem mass spectrometry allowed the interference-free detection of fluprostenol under the rapid elution conditions, with a limit of quantitation of 25 pg ml−1 fluprostenol, using 0.2 ml plasma sample volumes. The method was linear over three orders of magnitude, yielded accurate and precise results and allowed the pharmacokinetic profile of fluprostenol to be defined following intravenous administration in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号