首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 984 毫秒
1.
A method is proposed for the determination of nicotine and cotinine in human urine, plasma and saliva. Nicotine and cotinine were extracted from alkalinized sample with ethyl ether and concentrated to minimum volume with nitrogen stream. The volatility of nicotine was prevented by the addition of acetic acid to the organic solvent during evaporation. Peak shapes and quantitation of nicotine and cotinine are excellent, with linear calibration curves over a wide range of 1-10,000 ng/ml. The detection limits of nicotine and cotinine are 0.2 ng/ml in urine and 1.0 ng/ml in plasma and saliva. The intra-day precision of nicotine and cotinine in all samples was <5% relative standard deviation (RSD). Urine, plasma and saliva samples of 303 non-smoking and 41 smoking volunteers from a girl's high school in Korea were quantified by the described procedure. As a result, the concentrations of nicotine and cotinine in plasma ranged from 6 to 498 ng/ml and 4 to 96 ng/ml. Otherwise, those of nicotine and cotinine in saliva ranged from 0 to 207 ng/ml and 0 to 42 ng/ml, and those of nicotine and cotinine in urine ranged from 0 to 1,590 ng/ml and 0 to 2,986 ng/ml, respectively. We found that the concentration of cotinine in plasma was successfully predicted from the salivary cotinine concentration by the equation y=2.31x+4.76 (x=the concentration of cotinine in saliva, y=the concentration of cotinine in plasma). The results show that through the accurate determination of cotinine in saliva, the risk of ETS-exposed human can be predicted.  相似文献   

2.
A rapid and sensitive method is described for the simultaneous determination of nicotine and its principal metabolite, cotinine, in plasma. A one-step extraction procedure is employed and the quantitative analyses are performed by capillary column gas chromatography using a thermionic specific detector. Other special measures to avoid contamination from external sources such as atmosphere, solvents and laboratory equipment, which constitutes the major limiting factor of nicotine assay, were also undertaken. The structural analogues of nicotine and cotinine, N-methylanabasine and N-ethylnorcotinine, are used as internal standards. Moreover, a micromethod, which requires only 0.1 ml of plasma and found to be suitable for analysis of cotinine in finger-tip samples of blood, is described. Linearity over the concentration ranges 5–100 ng of nicotine per ml of plasma and 5–500 ng of cotinine per ml of plasma is demonstrated. The precision of the method has been investigated by determining the reproducibility at different levels of nicotine and cotinine within the working ranges, for both 1-ml and 0.1-ml samples of plasma.  相似文献   

3.
The objective of this study was to compare cotinine concentrations in urine and saliva using gas chromatography (GC), high-performance liquid chromatography (HPLC) and enzyme-linked immunosorbent assay (ELISA). Ninety-four subjects were selected (27 smokers and 67 non-smokers) and interviewed using questionnaire. Of the non-smokers, 39 had been exposed to environmental tobacco smoke (ETS) and 28 had not been exposed to ETS. Cotinine levels among smokers were highest using all three measurements, followed by ETS exposed subjects and non-smokers. Cotinine levels in urine, using HPLC, correlated significantly with levels measured using ELISA (r=0.92) and GC-nitrogen-phosphorus detection (NPD) (r=0.92). Salivary cotinine levels measured using ELISA did not correlate significantly with either HPLC (r=0.37) or GC-NPD (r=0.33) measurements. Multiple regression models were used to adjust for age, gender, drug use and health status, and it was found that cotinine levels in urine and saliva were significantly correlated with smoking pack-year. The authors conclude that urinary cotinine concentration is a more accurate biomarker for ETS than salivary cotinine concentration.  相似文献   

4.
A rapid and selective assay of nicotine, cotinine and rans-3'-hydroxycotinine in human serum, based on high-performance liquid chromatography with UV detection has been developed. The compounds were subjected to solid-phase extraction, using Extrelut 1 cartridges. Recoveries were ca. 95% for nicotine, 90% for cotinine and 50–55% for trans-3'-hydroxycotinine. The limit of quantitation observed with this method was 10 ng/ml for nicotine and 5 ng/ml for each of the metabolites. The compounds were also identified using high-performance liquid chromatography with particle beam mass spectrometry, to confirm their presence in human serum.  相似文献   

5.
A simple, sensitive, and rapid gas chromatographic–mass spectrometric method is described for the simultaneous detection and quantitation of nicotine and its metabolite, cotinine, in urine and serum. The analytes and their respective deuterated internal standards were extracted by liquid–liquid extraction coupled to centrifugation and evaporation. The detection limit of the assay was 0.16 ng/ml for both nicotine and cotinine. The limit of quantitation for each analyte was 1.25 ng/ml.  相似文献   

6.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

7.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

8.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

9.
When measuring fentanyl and midazolam simultaneously in the same plasma sample with standard high-performance liquid chromatography–ultraviolet (HPLC–UV) detection, overlap of the fentanyl peak by the midazolam peak occurs, which makes fentanyl determination impossible. We tested the hypothesis that by acidifying the methanol mobile phase with 0.02% perchloric acid, 70%, it would be possible to separate both peaks. The UV detector was set at 200 nm. Calibration curves for fentanyl (range 0–2000 pg/ml) and midazolam (range 0–400 ng/ml) were linear (r>0.99). The detection limits were 200 pg/ml (fentanyl) and 10 ng/ml (midazolam). Precision and accuracy for intra- and inter-assay variability as well as in-line validation with quality control samples (QCS) were acceptable (< 15 and 20%, respectively), except for fentanyl QCS of 200 pg/ml (17.8% precision). Although less sensitive than gas chromatography–mass spectrometry (GC–MS), reliable measurements of fentanyl, simultaneously with midazolam, can be performed with this HPLC–UV system.  相似文献   

10.
A rapid and sensitive capillary gas-chromatographic method with nitrogen-sensitive detection is reported for the simultaneous analysis of nicotine and cotinine levels occurring in the plasma, saliva, and urine of regular tobacco smokers. The proposed assay has a linear output, has satisfactory accuracy over the range of concentrations of both amines encountered in active smokers, and has also been successful in the analysis of the urine samples of passive smokers. Its lower limit of sensitivity is 0.2 ng of nicotine and 0.5 ng of cotinine per ml of plasma or saliva or per 100 l of urine.The beneficial characteristics of the presented method were achieved by the combination of solid phase extraction of 0.1–1.0 ml of fluid specimens, capillary column gas chromatography with splitless injection and nitrogen sensitive detection, and the use of separate, structurally analogous compounds as internal standards for nicotine. The suitability of the assay is shown by plasma concentration-time curves of nicotine and cotinine in a steady smoker during a 24 hours period.  相似文献   

11.
Here we report a sensitive liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method capable of quantifying nicotine down to 1 ng/ml and cotinine to 10 ng/ml from 1.0 ml of human plasma. The method was validated over linear ranges of 1.0–50.0 ng/ml for nicotine and 10.0–500.0 ng/ml for cotinine, using deuterated internal standards. Compounds were simply extracted from alkalinized human heparinized plasma with methylene chloride, reconstituted into a solution of acetonitrile, methanol and 10 mM ammonium acetate (53:32:15, v/v) after the organic phase was dried down, and analyzed on the LC-MS-MS, which is a PE Sciex API III system equipped with a Keystone BDS Hypersil C18 column and atmospheric pressure chemical ionization (APCI) interface. The between-run precision and accuracy of the calibration standards were ≤6.42% relative standard deviation (R.S.D.) and ≤11.8%n relative error (R.E.) for both nicotine and cotinine. The between-run and within-run precision and accuracy of quality controls. (2.5, 15.0, 37.5 ng/ml for nicotine and 25.0, 150.0, 375.0 ng/ml for cotinine), were ≤6.34% R.S.D. and ≤7.62% R.E. for both analytes. Sample stabilities in chromatography, in processing and in biological matrix were also investigated. This method has been applied to pharmacokinetic analysis of nicotine and cotinine in human plasma.  相似文献   

12.
The paper describes a HPLC–fluorimetric procedure for the determination of methylenedioxyamphetamine, methylenedioxymethamphetamine, methylenedioxyethamphetamine and N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine in urine, serum, saliva and street samples, that features interesting advantages over other procedures previously described. The method requires a very small sample volume (100 μl) and no extraction, lacks matrix effect, and is not time consuming. Linearity was in the range 50–1000 ng/ml regardless of matrix. Sensitivity and detection limit were 50 ng/ml and 10 ng/ml, respectively, but they may reach 10 ng/ml and 2 ng/ml if a slight modification is introduced in the procedure. Intra- and inter-day precision were always within 5% and 8%, respectively. Recovery was satisfactory for all matrices. The described procedure could be successfully used for clinical, epidemiological and forensic applications.  相似文献   

13.
A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 μl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid–liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography–tandem mass spectrometry (LC–MS–MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from −8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC–MS–MS are discussed in this paper.  相似文献   

14.
A reversed-phase, high-performance liquid chromatographic method using UV detection is described for the assay of the major metabolite of phentolamine in plasma and urine before or after enzymatic hydrolysis. Plasma is deproteinized with methanol. The sensitivity limit is 200 ng/ml using 150-μl samples. Urine is either diluted with water or purified after enzymatic hydrolysis. Concentrations down to 2–3 μg/ml could be quantified with acceptable precision. This method was applied to plasma and urine samples from subjects given phentolamine.  相似文献   

15.
Solid-phase microextraction (SPME) was investigated as a sample preparation method for assaying the neuroleptic drug clozapine in human plasma. A mixture of human plasma, water, loxapine (as internal standard) and aqueous NaOH was extracted with a 100-μm polydimethylsiloxane (PDMS) fiber (Supelco). Desorption of the fiber was performed in the injection port of a gas chromatograph at 260°C (HP 5890; 30 m×0.53 mm I.D., 1 μm film capillary; nitrogen–phosphorous selective detection). Fibers were used repeatedly in up to about 75 analyses. The recovery was found to be 3% for clozapine from plasma after 30 min of extraction. However, in spite of the low recovery, the analyte was well separated and the calibration was linear between 100 and 1000 ng/ml. The within-day and between-day precision was consistently about 8 to 15% at concentrations of 200 ng/ml to 1000 ng/ml. No interfering drug was found. The limit of detection was 30 ng/ml. The sample volume was 250 μl. The influence of the concentration of proteins, triglycerides and salt, i.e., changes in the matrix on the peak areas and peak-area ratios was studied. The method is not impaired by physiological changes in the composition of the matrix. Good agreement was found with a liquid–liquid extraction–gas–liquid chromatography (LLE–GLC) standard method and an on-line column-switching high-performance liquid chromatography (HPLC) method for patients’ samples and spiked samples, respectively. It is concluded that the method can be used in the therapeutic drug monitoring of clozapine because the therapeutic window of clozapine is from 350 to 600 ng/ml.  相似文献   

16.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed and validated for the measurement of (−)-2′-deoxy-3′-thiacytidine (3TC) in human serum. The method included precipitation of serum proteins by trichloroacetic acid (20%, w/v) treatment followed by centrifugation. The resulting supernatant was directly injected and 3TC was isocratically chromatographed on a reversed-phase C18 column using a mixture of phosphate buffer and methanol (88.3:11.7, v/v) and monitored at 280 nm. The limit of quantitation was 20 ng/ml using 100 μl of serum. The standard curve was linear within the range of 20–10 000 ng/ml. Replicate analysis of three quality control samples (40–1500 ng/ml) led to satisfactory intra- and itner-assay precision (coefficient of variation from 3.0 to 12.9%) and accuracy (deviation from −6.3 to 9.7%). Moreover, sample treatment processes including human immunodeficiency virus (HIV) heat-inactivation, exposure at room temperature and freezing-thawing cycles did not influence the stability of the analyte. This assay was successfully applied to the determination of 3TC serum levels in HIV-infected patients. In addition, preliminary results indicated that this procedure may also be extended to the measurement of 3TC in human plasma and urine.  相似文献   

17.
This paper describes a novel liquid chromatographic method for the quantitation of 2-naphthol in human urine. Urine samples were extracted after enzymatic hydrolysis of glucuronides and sulfates; 2-naphthol was then separated using reversed-phase high-performance liquid chromatography. The corresponding detection limits were 0.04 ng/ml for the standard sample in acetonitrile and 0.13 ng/ml for urine samples. The level of urinary 2-naphthol in 100 Korean shipyard workers was analyzed using this new method. The level ranged from 0.21 ng/ml (0.26 μmol/mol creatinine) to 34.19 ng/ml (59.11 μmol/mol creatinine), and the mean±standard deviation was 5.08 ng/ml (6.60 μmol/mol creatinine)±5.75 ng/ml (9.22 μmol/mol creatinine). The mean±standard deviation of urinary 2-naphthol level of smokers, 7.03 ng/ml (8.49 μmol/mol creatinine)±6.16 ng/ml (10.23 μmol/mol creatinine), was significantly higher than that of non-smokers, 2.49 ng/ml (4.10 μmol/mol creatinine)±3.92 ng/ml (7.03 μmol/mol creatinine).  相似文献   

18.

Background

A smoke-free law came into effect in Spain on 1st January 2006, affecting all enclosed workplaces except hospitality venues, whose proprietors can choose among totally a smoke-free policy, a partial restriction with designated smoking areas, or no restriction on smoking on the premises. We aimed to evaluate the impact of the law among hospitality workers by assessing second-hand smoke (SHS) exposure and the frequency of respiratory symptoms before and one year after the ban.

Methods and Finding

We formed a baseline cohort of 431 hospitality workers in Spain and 45 workers in Portugal and Andorra. Of them, 318 (66.8%) were successfully followed up 12 months after the ban, and 137 nonsmokers were included in this analysis. We obtained self-reported exposure to SHS and the presence of respiratory symptoms, and collected saliva samples for cotinine measurement. Salivary cotinine decreased by 55.6% after the ban among nonsmoker workers in venues where smoking was totally prohibited (from median of 1.6 ng/ml before to 0.5 ng/ml, p<0.01). Cotinine concentration decreased by 27.6% (p = 0.068) among workers in venues with designated smoking areas, and by 10.7% (p = 0.475) among workers in venues where smoking was allowed. In Portugal and Andorra, no differences between cotinine concentration were found before (1.2 ng/ml) and after the ban (1.2 ng/ml). In Spain, reported respiratory symptom declined significantly (by 71.9%; p<0.05) among workers in venues that became smoke-free. After adjustment for potential confounders, salivary cotinine and respiratory symptoms decreased significantly among workers in Spanish hospitality venues where smoking was totally banned.

Conclusions

Among nonsmoker hospitality workers in bars and restaurants where smoking was allowed, exposure to SHS after the ban remained similar to pre-law levels. The partial restrictions on smoking in Spanish hospitality venues do not sufficiently protect hospitality workers against SHS or its consequences for respiratory health.  相似文献   

19.
Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC–MS–MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC–MS–MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC–MS interface. The standard curve range in plasma was 0.5–50 ng/ml for MOR, 1.0–100 ng/ml for M6G, and 10–1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC–MS–MS systems to analyze over one thousand samples from clinical trials.  相似文献   

20.
We present fast LC–MS–MS analyses of multicomponent mixtures containing flavones, sulfonamides, benzodiazepines and tricyclic amines. Using a short microbore HPLC column with small particle size, five to eight compounds were partially resolved within 15 to 30 s. TurboIonSpray and atmospheric pressure chemical ionization interfaces were well suited to tolerate the higher eluent flow-rates of 1.2 to 2 ml/min. The methods were applied to biological sample matrices after clean-up using solid-phase or liquid–liquid extraction. Good precision and accuracy (average 8.9 and 97.7%, respectively) were achieved for the determination of tricyclic amines in human plasma. Benzodiazepines were determined in human urine with average precision of 9% and average accuracy of 95% for intra- and inter-assay. Detection limits in the low ng/ml range were obtained. An example for 240 injections per hour of demonstrated the feasibility of rapid LC–MS–MS analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号