首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Process Biochemistry》1999,34(3):281-288
A novel hybrid bioreactor was designed to remove volatile organic compounds from wastewater and its performance was investigated. The bioreactor was composed of a biofilter section and a bubble column bioreactor section. Benzene was used as a model compound and the influent benzene was removed by immobilized cells in a bubble column bioreactor. Gas phase benzene stripped by air injection was removed in a biofilter. When the superficial air flow rate was 21.1 m h−1 (0.76 min of residence time in a biofilter), up to 2.2 ppm of benzene in gas phase was removed completely in a biofilter and the maximum removal rate was 4.71 mg day−1 cm−3. The concentration profile of benzene along the biofilter column was dependent on the superficial air flow rate and the degree of microbial adaptation. Air flow rate and residence time were found to be the most important operation parameters for the hybrid bioreactor. By manipulating these operational parameters, the removal efficiency and capacity of the hybrid bioreactor could be enhanced. The organic load on the hybrid bioreactor could be shared by the biofilter and bubble column bioreactors and the fluctuation of load on the hybrid bioreactor could be absorbed by changing the distribution of benzene between biofilter and bubble column bioreactors. The maximum removal capacity of the hybrid bioreactor in the experimental range was obtained when the biofilter took 50.3% of influent benzene while 100% of removal efficiency was achieved when the biofilter took 72.3% of influent benzene.  相似文献   

2.
In this study, a novel fibrous bioreactor was developed for treating odorous compounds present in contaminated air. The first stage of this work was a preliminary study which aimed at investigating the feasibility of using the fibrous bioreactor for the removal of malodorous volatile fatty acids (VFA) that is a common odorous contaminant generated from anaerobic degradation of organic compounds. The kinetics of microbial growth and VFA degradation in the selected culture, and the performance of the submerged bioreactor at different VFA mass loadings were studied. Above 95% of VFA removal efficiencies were achieved at mass loadings up to 22.4 g/m(3)/h. In the second stage, the odour treatment process was scaled up with system design and operational considerations. A trickling biofilter with synthetic fibrous packing medium was employed. The effects of inlet VFA concentration and empty bed retention time (EBRT) on the process performance were investigated. The bioreactor was effective in removing VFA at mass loadings up to 32 g/m(3)/h, beyond which VFA started to accumulate in the recirculation liquid, indicating the biofilm was unable to degrade all of the VFA introduced. Although VFA accumulated in the liquid phase, the removal efficiency remained above 99%. This suggested that the biochemical reaction rather than gas-liquid mass transfer was the limiting step of the treatment process. In addition, the biotrickling filter was stable for long-term operation with relatively low and steady pressure drop, no clogging and degeneration of the packing material occurred during the four-month study.  相似文献   

3.
《Process Biochemistry》2007,42(4):554-560
In a previous study, a hybrid bioreactor comprised of a bubble column bioreactor section and a biofilter section was successfully applied to the treatment of benzene. In order to design and optimize the bioreactor system for actual use in the field, simple but effective mathematical models of the two-stage system were required. Since the liquid phase in the bubble column bioreactor section was well mixed, a CSTR (continuously stirred tank reactor) model was adopted for this section, with benzene removal by both air stripping and biodegradation being considered in the model equations. The gaseous benzene degradation in the biofilter section was described using a PFR (plug flow reactor) model. The combined model was validated through independent experiments, and the simulation results were in a good agreement with measured data.  相似文献   

4.
A trickle‐bed air biofilter (TBAB) was evaluated under conditions of interchanging the feed volatile organic compounds (VOCs) in the sequence methyl ethyl ketone (MEK), toluene, methyl isobutyl ketone (MIBK), styrene, and then back to MEK. The obtained performance results revealed that the biofilter provided high removal efficiency within the critical loading of each VOC, which was previously defined in the non‐interchanging VOC fed biofilter. The biofilter easily acclimated to the oxygenated compounds (MEK and MIBK), but re‐acclimation was delayed for the aromatic compounds (toluene and styrene). Ratios of the molar mass of CO2 produced per molar mass of VOC removed were investigated. It has been found that the ratios for the aromatic compounds closely resembled the theoretical complete chemical oxidation based ratios while larger differences were encountered with the oxygenated compounds. Denaturing gradient gel electrophoresis (DGGE) analysis of 16S rRNA genes was used to assess the impact of interchanging VOCs on the bacterial community structure in the biofilter. The results from denaturing gradient gel electrophoresis (DGGE) showed that the structure of the microbial community in the biofilter was different after each interchange of VOCs.  相似文献   

5.
The performance of a biofilter packed with Active Carbon (AC) was evaluated. The effluent (alcohol, ketones, esters, aromatic and chlorinated compounds) treated was a representative mixture of most common industrial emissions. To achieve a better knowledge of multicomponent adsorption mechanisms, and to underline the interest of inoculating AC, a control abiotic humidified filter had been operated in the same conditions as the biofilter. For a load of 110 g VOC m(-3) AC h(-1), after 55 days of operation, the removal efficiency was higher in the biotic than in the abiotic filter (85% vs 55%, respectively). Moreover, in the biofilter, at steady state, the elimination of all compounds was almost complete except for chlorinated compounds and p-xylene (removal efficiency of 25% and 64%, respectively). The microbial colonization of AC involved a decrease of the adsorption sites accessibility and enhanced the treatment of VOCs (volatile organic compounds) having a lower affinity for activated carbon. Moreover, while aromatic compounds and MIBK were eliminated along the overall height of the biofilter, pollutants with reduced affinity for AC, such as methanol, acetone, and halogenated compounds were only treated on the second half of the reactor. Thus, the affinity for activated carbon was an important parameter controlling the biodegradation process. Nevertheless, the use of AC as packing material in biofilters treating complex mixtures of VOCs is limited. Actually, similar removal efficiency could be reached, in the same conditions, for a biofilter packed with granular peat. Furthermore, for the biofilter packed with AC, the column height necessary to remove biodegradable compounds, with reduced affinity for the support, was important.  相似文献   

6.
Biofiltration of volatile organic compounds   总被引:6,自引:0,他引:6  
The removal of volatile organic compounds (VOCs) from contaminated airstreams has become a major air pollution concern. Improvement of the biofiltration process commonly used for the removal of odorous compounds has led to a better control of key parameters, enabling the application of biofiltration to be extended also to the removal of VOCs. Moreover, biofiltration, which is based on the ability of micro-organisms to degrade a large variety of compounds, proves to be economical and environmentally viable. In a biofilter, the waste gas is forced to rise through a layer of packed porous material. Thus, pollutants contained in the gaseous effluent are oxidised or converted into biomass by the action of microorganisms previously fixed on the packing material. The biofiltration process is then based on two principal phenomena: (1) transfer of contaminants from the air to the water phase or support medium, (2) bioconversion of pollutants to biomass, metabolic end-products, or carbon dioxide and water. The diversity of biofiltration mechanisms and their interaction with the microflora mean that the biofilter is defined as a complex and structured ecosystem. As a result, in addition to operating conditions, research into the microbial ecology of biofilters is required in order better to optimise the management of such biological treatment systems.  相似文献   

7.
Biofiltration of air: a review   总被引:9,自引:0,他引:9  
In this paper we present a review of the existing air pollution control technologies (APCT), when used essentially for the elimination of volatile organic compounds (VOC). The biotechnologies referred to, bioscrubbers, biotrickling filters and biofilters, are also described. A more detailed review of biofiltration is proposed, presenting the most recent and latest developments achieved in the field of bioprocessing. In particular, the influence of the filter bed, the polluted air flowrates, the pollutants, the pressure drop, bed moisture content, temperature, nutrients, pH and the microorganisms are reviewed. Models of biofiltration are also presented.  相似文献   

8.
Abstract

In this paper we present a review of the existing air pollution control technologies (APCT), when used essentially for the elimination of volatile organic compounds (VOC). The biotechnologies referred to, bioscrubbers, biotrickling filters and biofilters, are also described. A more detailed review of biofiltration is proposed, presenting the most recent and latest developments achieved in the field of bioprocessing. In particular, the influence of the filter bed, the polluted air flowrates, the pollutants, the pressure drop, bed moisture content, temperature, nutrients, pH and the microorganisms are reviewed. Models of biofiltration are also presented.  相似文献   

9.
An adapted bioactive foamed emulsion bioreactor for the treatment of benzene vapor has been developed. In this reactor, bed clogging was resolved by bioactive foam as a substitute of packing bed for interfacial contact of liquid to gaseous phase. The pollutant solubility has been increased using biocompatible organic phase in liquid phase and this reactor can be applied for higher inlet benzene concentration. Experimental results showed a benzene elimination capacity (EC) of 220 g m−3 h−1 with removal efficiency (RE) of 85% for benzene inlet concentration of 1–1.2 g m−3 at 15 s gas residence time in bioreactor. Assessment of benzene concentration in liquid phase showed that a significant amount of transferred benzene mass has been biodegraded. By optimizing the operational parameters of bioreactor, continuous operation of bioreactor with high EC and RE was demonstrated. With respect to the results, this reactor has the potential to be applied instead of biofilter and biotrickling filters.  相似文献   

10.
While gasoline vapor emissions are common sources of air pollution, very few results have been published on the biofilter biodegradation of gasoline vapors in flowing waste gases. This investigation reports on a bench‐scale biofilter of an ID of 50 mm and a bed height of 850 mm with an inexpensive fire clay chip medium as a packing material. The biofilter was inoculated with a concentrate of a mixed culture of the common microflora. After an acclimatization period of three weeks, loading tests were carried out at increasing gasoline inlet concentrations at a constant Empty Bed Retention Time (EBRT) of 16 min. Evaluating the removal rate and efficiency of aliphatic and aromatic fractions of the gasoline vapor, it was found that in a range of overall organic loading (OLTPH) up to 33.6 g/m3 h the removal efficiency of aromatic hydrocarbons decreased from 90 to 70 %, while that of the aliphatic components decreased much more significantly from 60 to 10 % after six months of operation. The removal rate and efficiency achieved for total petroleum hydrocarbons were 13 g/m3 h and 45 %, respectively. The microbial strains and genera of culturable cells in the inoculum and in the biofilm after six months of gasoline degradation were evaluated.  相似文献   

11.
Biodegradation of ethanol vapour in a biofilter   总被引:1,自引:0,他引:1  
Biofiltration is a cost effective air pollution control technology for volatile organic compounds. Biofiltration of ethanol vapour from air stream was evaluated in this study. Experimental investigations were conducted on a laboratory scale biofilter, containing mixture of compost and polystyrene inert particles as the filter materials. Mixed consortium of activated sludge was used as a inoculum. The continuous performance of biofilter for ethanol removal was monitored for different concentrations and flow rates. The removal efficiencies decreased at higher concentrations and higher gas flow rates. A maximum elimination capacity of 195 g mх hу was achieved. The response of biofilter to shut down and restart-up operation showed that the biofilm has got a good stability.  相似文献   

12.
Biofiltration has proven an efficient tool for the elimination of volatile organic compounds (VOCs) and ammonia from livestock facilities, thereby reducing nuisance odors and ammonia emissions to the local environment. The active microbial communities comprising these filter biofilms have not been well characterized. In this study, a trickle biofilter treating air from a pig facility was investigated and proved efficient in removing carboxylic acids (>70% reduction), mainly attributed to the primary filter section within which reduced organic sulfur compounds were also depleted (up to 50%). The secondary filter eliminated several aromatic compounds: phenol (81%), p-cresol (89%), 4-ethylphenol (68%), indole (48%), and skatole (69%). The active butyric acid degrading bacterial community of an air filter sample was identified by DNA stable-isotope probing (DNA-SIP) and microautoradiography, combined with fluorescence in situ hybridization (MAR-FISH). The predominant 16S rRNA gene sequences from a clone library derived from "heavy" DNA from [(13)C(4)]butyric acid incubations were Microbacterium, Gordonia, Dietzia, Rhodococcus, Propionibacterium, and Janibacter, all from the Actinobacteria. Actinobacteria were confirmed and quantified by MAR-FISH as being the major bacterial phylum assimilating butyric acid along with several Burkholderiales-related Betaproteobacteria. The active bacterial community assimilating dimethyl disulfide (DMDS) was characterized by DNA-SIP and MAR-FISH and found to be associated with the Actinobacteria, along with a few representatives of Flavobacteria and Sphingobacteria. Interestingly, ammonia-oxidizing Betaproteobacteria were also implicated in DMDS degradation, as were fungi. Thus, multiple isotope-based methods provided complementary data, enabling high-resolution identification and quantitative assessments of odor-eliminating Actinobacteria-dominated populations of these biofilter environments.  相似文献   

13.
The biological removal of pollutants, especially through biotrickling filters (BTFs), has recently become attractive for the low investment and operational costs and the low secondary pollution. This paper is intended to investigate the state of the art on BTF applications. After an overview on the biodegradation process and the typical parameters involved, this paper presents the analysis of a group of 16 literature studies chosen as the references for this sector. The reference studies differ from one another by the pollutants treated (volatile organic compounds [VOC], hydrogen sulphide, nitrogen oxides and trimethylamine), the geometry and size of the BTFs, and the procedures of the tests. The reference studies are analyzed and discussed in terms of the operational conditions and the results obtained, especially with respect to the removal efficiencies (REs) and the elimination capacities (ECs) of the pollutants considered. Empty bed residence time (EBRT), pollutant loading rate, temperature, pH, oxygen availability, trickling liquid flow rate, inoculum selection and biomass control strategies revealed to be the most important operational factors influencing the removal performance of a BTF.  相似文献   

14.
The removal of a 1:1 by weight mixture of ethanol and ethyl acetate was studied in a gas phase biotrickling filter running under conditions that simulated industrial emissions from the flexographic sector, i.e. discontinuous loading (twelve hours per day and five days per week) and oscillating concentration of the inlet stream. Three sets of experimental conditions were tested in which empty‐bed residence time varied from 60 to 25 s (inlet loads from 50 to 90 g C m?3 h?1). The biotrickling filter reached a maximum elimination capacity of 48.5 g C m?3 h?1 (removal efficiency=68.9%) for an empty‐bed residence time of 40 s. A decrease in the residence time from 40 to 25 s adversely affected the elimination capacity (40.3 g C m?3 h?1, removal efficiency=46.6%). For the three tested residence times, outlet concentrations during pollutant feeding were above 100 mg C m?3 (EU legal limit for flexographic facilities). Then an activated carbon prefilter was installed to buffer the fluctuating concentration, enabling a more stable operation. The desorbed pollutant from the activated carbon during non‐feeding hours also served as an extra source of substrate, avoiding severe starvation. The use of the activated carbon prefilter with a volume 25 times lower than that of the bioreactor was shown to reach an average outlet emission concentration lower than 50 mg C m?3 operating the biotrickling filter at an empty‐bed residence time of 40 s, with a maximum elimination capacity of 59.6 g C m?3 h?1 (removal efficiency=92.0%).  相似文献   

15.
We report on the implementation of proton transfer reaction‐mass spectrometry (PTR‐MS) technology for on‐line monitoring of volatile organic compounds (VOCs) in the off‐gas of bioreactors. The main part of the work was focused on the development of an interface between the bioreactor and an analyzer suitable for continuous sampling of VOCs emanating from the bioprocess. The permanently heated sampling line with an inert surface avoids condensation and interaction of volatiles during transfer to the PTR‐MS. The interface is equipped with a sterile sinter filter unit directly connected to the bioreactor headspace, a condensate trap, and a series of valves allowing for dilution of the headspace gas, in‐process calibration, and multiport operation. To assess the aptitude of the entire system, a case study was conducted comprising three identical cultivations with a recombinant E. coli strain, and the volatiles produced in the course of the experiments were monitored with the PTR‐MS. The high reproducibility of the measurements proved that the established sampling interface allows for reproducible transfer of volatiles from the headspace to the PTR‐MS analyzer. The set of volatile compounds monitored comprises metabolites of different pathways with diverse functions in cell physiology but also volatiles from the process matrix. The trends of individual compounds showed diverse patterns. The recorded signal levels covered a dynamic range of more than five orders of magnitude. It was possible to assign specific volatile compounds to distinctive events in the bioprocess. The presented results clearly show that PTR‐MS was successfully implemented as a powerful bioprocess‐monitoring tool and that access to volatiles emitted by the cells opens promising perspectives in terms of advanced process control. Biotechnol. Bioeng. 2012; 109: 3059–3069. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
Biofiltration of air polluted by volatile organic compounds is now recognized by the industrial and research communities as an effective and viable alternative to standard environmental technologies. Whereas many studies have focused on solid/liquid/gas biofilters, there have been fewer reports on waste air treatment using other biological processes, especially in a solid/gas biofilter. In this study, a comparison was made of the hydrolysis of halogenated compounds (such as 1-chlorobutane) by lyophilized Rhodococcus erythropolis cells in a novel solid/gas biofilter and in the aqueous phase. We first determined the culture conditions for the production of R. erythropolis cells with a strong dehalogenase activity. Four different media were studied and the amount of 1-chlorobutane was optimized. Next, we report the possibility to use R. erythropolis cells in a solid/gas biofilter in order to transform halogenated compounds in corresponding alcohols. The effect of experimental parameters (total flow into the biofilter, thermodynamic activity of the substrates, temperature, carbon chain length of halogenated substrates) on the activity and stability of lyophilized cells in the gas phase was determined. A critical water thermodynamic activity (a(w)) of 0.4 is necessary for the enzyme to become active and optimal dehalogenase activity for the lyophilized cells is obtained for an a(w) of 0.9. A temperature of reaction of 40 degrees C represents the best compromise between stability and activity. Activation energy of the reaction was determined and found equal to 59.5 KJ/mol. The pH effect on the dehalogenase activity of R. erythropolis cells was also studied in the gas phase and in the aqueous phase. It was observed that pH 9.0 provided the best activity in both systems. We observed that in the aqueous phase R. erythropolis cells were less sensitive to the variation in pH than R. erythropolis cells in the gas phase. Finally, the addition of volatile Lewis base (triethylamine) in the gaseous phase and the action of the lysozyme in order to permeabilize the cells was found to be highly beneficial to the effectiveness of the biofilter.  相似文献   

17.
Xu M  Wen X  Yu Z  Li Y  Huang X 《Bioresource technology》2011,102(10):5617-5625
Anaerobic membrane bioreactor and online ultrasonic equipment used to enhance membrane filtration were coupled to form a hybrid system (US-AnMBR) designed for long-term digestion of waste activated sludge. The US-AnMBR was operated under volatile solids loading rates of 1.1-3.7 gVS/L·d. After comprehensive studies on digestion performance and membrane fouling control in the US-AnMBR, the final loading rate was determined to be 2.7 gVS/L·d with 51.3% volatile solids destruction. In the US-AnMBR, the improved digestion was due to enhanced sludge disintegration, as indicated by soluble matter comparison in the supernatant and particle size distribution in the digested sludge. Maximum specific methanogenic activity revealed that ultrasound application had no negative effect on anaerobic microorganisms. Furthermore, implementing ultrasound effectively controlled membrane fouling and successfully facilitated membrane bioreactor operation. This lab-scale study demonstrates the potential feasibility and effectiveness of setting up a US-AnMBR system for sludge digestion.  相似文献   

18.
In recent years, biofiltration has been increasingly applied as an air pollution control technology to minimize or eliminate emissions of volatile organic compounds from industrial sources and environmental remediation activities. Although the ability of this technology to maintain high removal efficiency during relatively steady loading conditions has been well established for many waste streams, relatively little research has focused on development of operating strategies that could improve treatment performance during transient loading conditions typical of industrial operations. In the research described herein, two operating strategies were evaluated over a period of 295 days in biofilters treating a model waste gas stream containing a two-component mixture of methyl ethyl ketone (MEK) and toluene. One biofilter was operated as a sequencing batch biofilter (SBB), and the other was operated as a conventional continuous-flow biofilter (CFB). During "normal" steady loading conditions, the model waste stream contained MEK concentrations ranging from 80 to 89 ppmv and toluene concentrations ranging from 28 to 30 ppmv. Both biofilter operating strategies resulted in stable long-term performance with greater than 99% contaminant removal during these normal loading conditions. On a regular basis, the influent MEK and toluene concentrations were temporarily increased to five times the normal influent concentration for the duration of 1 h to test performance during transient "shock loading" conditions. Biofilter performance during the model shock loading conditions demonstrate that SBB operating strategies can result in superior treatment in two important areas: (1) overall mass of contaminants removed and (2) minimum instantaneous removal efficiency.  相似文献   

19.
A novel immobilised bioreactor has been developed especially for the treatment of pollutants characterized by high volatility along with high water solubility and low microbial yields. The new bioreactor referred to as the rotating rope bioreactor (RRB) provides higher interfacial area (per unit reactor liquid volume) along with high oxygen mass transfer rate, greater microbial culture stability; and consequently higher substrate loadings and removal rates in comparison to other conventional rectors for the treatment of volatile compounds. Pyridine was used as a model compound to demonstrate the enhanced performance with RRB, when compared to that reported with other conventional bioreactors. The experimental results indicate that the novel RRB system is able to degrade pyridine with removal efficiency of more than 85% at higher pyridine concentration (up to 1000 mg/l) and loading [up to 400 mg/m(2)/h (66.86 g/m(3)/h)], with a shorter hydraulic retention time (9-18 h). The reactor has been in operation for the past 15 months and no loss of activity has been observed.  相似文献   

20.
This study aimed to remove complex odorous gas produced from composting using a biotrickling filter and to observe the temporal and special distributions of bacteria, fungi, and actinomycetes. The removal efficiencies of the total volatile organic compounds (TVOC) were 26.1% and 81.5% before and after inoculation of volatile organic compounds (VOC)-degrading microbes, respectively. Especially trimethylamine was 100% degraded. In the first and second composting period, the odor reduction efficiencies showed average values of 86.2% and 94.5%, respectively. The total average of the bacteria in the biofilm was 2.06 × 109 CFU/g TS, which was 22.2% higher than that of the control (the culture of microbes prior to the inoculation of VOC-degrading microbes). The bacteria may have played a predominant role in odor removal. The total average of the fungi in the biofilm was 9.64 × 106 CFU/g TS, which was only 6.40% of the control. The total average of the actinomycetes in the biofilm was 5.10 × 105 CFU/g TS, which was 5.63 times higher than that of the control. Findings from this study showed that usage of a biotrickling filter is a promising process for the treatment of complex odorous gas.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏