首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
Endovascular coiling is the most common treatment for cerebral aneurysms. During the treatment, a sequence of embolic coils with different stiffness, shapes, sizes, and lengths is deployed to fill the aneurysmal sac. Although coil packing density has been clinically correlated with treatment success, many studies have also reported success at low packing densities, as well as recurrence at high packing densities. Such reports indicate that other factors may influence treatment success. In this study, we used a novel finite element approach and computational fluid dynamics (CFD) to investigate the effects of packing density, coil shape, aneurysmal neck size, and parent vessel flow rate on aneurysmal hemodynamics. The study examines a testbed of 80 unique CFD simulations of post-treatment flows in idealized basilar tip aneurysm models. Simulated coil deployments were validated against in vitro and in vivo deployments. Among the investigated factors, packing density had the largest effect on intra-aneurysmal velocities. However, multifactor analysis of variance showed that coil shape can also have considerable effects, depending on packing density and neck size. Further, linear regression analysis showed an inverse relationship between mean void diameter in the aneurysm and mean intra-aneurysmal velocities, which underscores the importance of coil distribution and thus coil shape. Our study suggests that while packing density plays a key role in determining post-treatment hemodynamics, other factors such as coil shape, aneurysmal geometry, and parent vessel flow may also be very important.  相似文献   

2.
Endovascular coiling aims to isolate the aneurysm from blood circulation by altering hemodynamics inside the aneurysm and triggering blood coagulation. Computational fluid dynamics (CFD) techniques have the potential to predict the post-operative hemodynamics and to investigate the complex interaction between blood flow and coils. The purpose of this work is to study the influence of blood viscosity on hemodynamics in coiled aneurysms. Three image-based aneurysm models were used. Each case was virtually coiled with a packing density of around 30%. CFD simulations were performed in coiled and untreated aneurysm geometries using a Newtonian and a Non-Newtonian fluid models. Newtonian fluid slightly overestimates the intra-aneurysmal velocity inside the aneurysm before and after coiling. There were numerical differences between fluid models on velocity magnitudes in coiled simulations. Moreover, the non-Newtonian fluid model produces high viscosity (>0.007>0.007 [Pa s]) at aneurysm fundus after coiling. Nonetheless, these local differences and high-viscous regions were not sufficient to alter the main flow patterns and velocity magnitudes before and after coiling. To evaluate the influence of coiling on intra-aneurysmal hemodynamics, the assumption of a Newtonian fluid can be used.  相似文献   

3.
Cerebral aneurysms constitute a major medical challenge as treatment options are limited and often associated with high risks. Statistically, up to 3% of patients with a brain aneurysm may suffer from bleeding for each year of life. Eight percent of all strokes are caused by ruptured aneurysms. In order to prevent this rupture, endovascular stenting using so called flow diverters is increasingly being regarded as an alternative to the established coil occlusion method in minimally invasive treatment. Covering the neck of an aneurysm with a flow diverter has the potential to alter the hemodynamics in such a way as to induce thrombosis within the aneurysm sac, stopping its further growth, preventing its rupture and possibly leading to complete resorption. In the present study the influence of different flow diverters is quantified considering idealized patient configurations, with a spherical sidewall aneurysm placed on either a straight or a curved parent vessel. All important hemodynamic parameters (exchange flow rate, velocity, and wall shear stress) are determined in a quantitative and accurate manner using computational fluid dynamics when varying the key geometrical properties of the aneurysm. All simulations are carried out using an incompressible, Newtonian fluid with steady conditions. As a whole, 72 different cases have been considered in this systematic study. In this manner, it becomes possible to compare the efficiency of different stents and flow diverters as a function of wire density and thickness. The results show that the intra-aneurysmal flow velocity, wall shear stress, mean velocity, and vortex topology can be considerably modified thanks to insertion of a suitable implant. Intra-aneurysmal residence time is found to increase rapidly with decreasing stent porosity. Of the three different implants considered in this study, the one with the highest wire density shows the highest increase of intra-aneurysmal residence time for both the straight and the curved parent vessels. The best hemodynamic modifications are always obtained for a small aneurysm diameter.  相似文献   

4.
Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in wide-neck and giant aneurysms. Placing of a stentlike device across the aneurysm neck may be sufficient to occlude the aneurysm by promoting intra-aneurysmal thrombosis; however, conclusive evidence of its efficacy is still lacking. In this study, we investigate in vitro the efficacy of custom designed flow divertors that will be subsequently implanted in a large cohort of animals. The aim of this study is to provide a detailed database against which in vivo results can be analyzed. Six custom designed flow divertors were fabricated and tested in vitro. The design matrix included three different porosities (75%, 70%, and 65%). For each porosity, there were two divertors with one having a nominal pore density double than that of the other. To quantify efficacy, the divertors were implanted in a compliant elastomeric model of an elastase-induced aneurysm model in rabbit and intra-aneurysmal flow changes were evaluated by particle image velocimetry (PIV). PIV results indicate a marked reduction in intra-aneurysmal flow activity after divertor implantation in the innominate artery across the aneurysm neck. The mean hydrodynamic circulation after divertor implantation was reduced to 14% or less of the mean circulation in the control and the mean intra-aneurysmal kinetic energy was reduced to 29% or less of its value in the control. The intra-aneurysmal wall shear rate in this model is low and implantation of the flow divertor did not change the wall shear rate magnitude appreciably. This in vitro experiment evaluates the characteristics of local flow phenomena such as hydrodynamic circulation, kinetic energy, wall shear rate, perforator flow, and changes of these parameters as a result of implantation of stentlike flow divertors in an elastomeric replica of elastase-induced saccular aneurysm model in rabbit. These initial findings offer a database for evaluation of in vivo implantations of such devices in the animal model and help in further development of cerebral aneurysm bypass devices.  相似文献   

5.

Introduction

Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC) of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited.

Material and Methods

We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months) was available in 72.6% (61/84) of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization.

Results

The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively). In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group.

Conclusion

The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the SAC group and may in part be due to flow diversion.  相似文献   

6.
Clinical studies suggest that aneurysm aspect ratio (AR) is an important indicator of rupture likelihood. The importance of AR is hypothesized to arise from its influence on intra-aneurysmal hemodynamics. It has been conjectured that slower flow in high AR sacs leads to a cascade of biological activities that weaken the aneurysm wall (Ujiie et al.,1999). However, the connection between AR, hemodynamics and wall weakening has never been proven. Animal models of saccular aneurysms provide a venue for evaluating this conjecture. The focus of this work was to evaluate whether a commonly used elastase induced aneurysm model in rabbits is suitable for a study of this kind from a hemodynamic perspective. In particular, to assess whether hemodynamic factors in low and high AR sacs are statistically different. To achieve this objective, saccular aneurysms were created in 51 rabbits and pulsatile computational fluid dynamics (CFD) studies were performed using rabbit specific inflows. Distinct hemodynamics were found in the low AR (AR<1.8, n=25), and high AR (AR>2.2, n=18) models. A single, stable recirculation zone was present in all low AR aneurysms, whereas a second, transient recirculation zone was also found in the superior aspect of the aneurysm dome for all high AR cases. Aneurysms with AR between 1.8 and 2.2 displayed transitional flow patterns. Differences in values and distributions of hemodynamic parameters were found between low and high AR cases including time averaged wall shear stress, oscillatory shear index, relative residence time and non-dimensional inflow rate. This work lays the foundation for future studies of the dependence of growth and remodeling on AR in the rabbit model and provides a motivation for further studies of the coupling between AR and hemodynamics in human aneurysms.  相似文献   

7.

Background and Purpose

In recurrent cerebral aneurysms treated by coil embolization, coil compaction is regarded as the presumptive mechanism. We test the hypothesis that aneurysm growth is the primary recurrence mechanism. We also test the hypothesis that the coil mass will translate a measurable extent when recurrence occurs.

Methods

An objective, quantitative image analysis protocol was developed to determine the volumes of aneurysms and coil masses during initial and follow-up visits from 3D rotational angiograms. The population consisted of 15 recurrence and 12 non-recurrence control aneurysms initially completely coiled at a single center. An investigator sensitivity study was performed to assess the objectivity of the methods. Paired Wilcoxon tests (p<0.05, one-tailed) were performed to assess for aneurysm and coil growth. The translation of the coil mass center at follow-up was computed. A Mann Whitney U-Test (p<0.05, one-tailed) was used to compare translation of coil mass centers between recurrence and control subjects.

Results

Image analysis protocol was found to be insensitive to the investigator. Aneurysm growth was evident in the recurrence cohort (p=0.003) but not the control (p=0.136). There was no evidence of coil compaction in either the recurrence or control cohorts (recurrence: p=0.339; control: p=0.429). The translation of the coil mass centers was found to be significantly larger in the recurrence cohort than the control cohort (p=0.047).

Conclusion

Aneurysm sac growth, not coil compaction, was the primary mechanism of recurrence following successful coil embolization. The coil mass likely translates to a measurable extent when recurrence occurs and has the potential to serve as a non-angiographic recurrence marker.  相似文献   

8.

Purpose

Flow diverters (FD) are increasingly being considered for treating large or giant wide-neck aneurysms. Clinical outcome is highly variable and depends on the type of aneurysm, the flow diverting device and treatment strategies. The objective of this study was to analyze the effect of different flow diverting strategies together with parent artery curvature variations on altering intra-aneurysmal hemodynamics.

Methods

Four ideal intracranial aneurysm models with different parent artery curvature were constructed. Computational fluid dynamics (CFD) simulations of the hemodynamics before and after applying five types of flow diverting strategies (single FD, single FD with 5% and 10% packing density of coils, two FDs with 25% and 50% overlapping rate) were performed. Changes in pressure, wall shear stress (WSS), relative residence time (RRT), inflow velocity and inflow volume rate were calculated and compared.

Results

Each flow diverting strategy resulted in enhancement of RRT and reduction of normalized mean WSS, inflow volume rate and inflow velocity in various levels. Among them, 50% overlapped FD induced most effective hemodynamic changes in RRT and inflow volume rate. The mean pressure only slightly decreased after treatment. Regardless of the kind of implantation of FD, the mean pressure, inflow volume rate and inflow velocity increased and the RRT decreased as the curvature of the parent artery increased.

Conclusions

Of all flow diverting strategies, overlapping FDs induced most favorable hemodynamic changes. Hemodynamics alterations post treatment were substantially influenced by parent artery curvature. Our results indicate the need of an individualized flow diverting strategy that is tailored for a specific aneurysm.  相似文献   

9.
Blood flow dynamics in saccular aneurysm models of the basilar artery   总被引:1,自引:0,他引:1  
Blood flow dynamics under physiologically realistic pulsatile conditions plays an important role in the growth, rupture, and surgical treatment of intracranial aneurysms. The temporal and spatial variations of wall pressure and wall shear stress in the aneurysm are hypothesized to be correlated with its continuous expansion and eventual rupture. In addition, the assessment of the velocity field in the aneurysm dome and neck is important for the correct placement of endovascular coils. This paper describes the flow dynamics in two representative models of a terminal aneurysm of the basilar artery under Newtonian and non-Newtonian fluid assumptions, and compares their hemodynamics with that of a healthy basilar artery. Virtual aneurysm models are investigated numerically, with geometric features defined by beta = 0 deg and beta = 23.2 deg, where beta is the tilt angle of the aneurysm dome with respect to the basilar artery. The intra-aneurysmal pulsatile flow shows complex ring vortex structures for beta = 0 deg and single recirculation regions for beta = 23.2 deg during both systole and diastole. The pressure and shear stress on the aneurysm wall exhibit large temporal and spatial variations for both models. When compared to a non-Newtonian fluid, the symmetric aneurysm model (beta = 0 deg) exhibits a more unstable Newtonian flow dynamics, although with a lower peak wall shear stress than the asymmetric model (beta = 23.2 deg). The non-Newtonian fluid assumption yields more stable flows than a Newtonian fluid, for the same inlet flow rate. Both fluid modeling assumptions, however, lead to asymmetric oscillatory flows inside the aneurysm dome.  相似文献   

10.
Hemodynamic stress in lateral saccular aneurysms   总被引:7,自引:0,他引:7  
The flow velocities in glass and silastic lateral aneurysm models were quantitatively measured with the non-invasive laser Doppler method. The influences of the elasticity of the wall, the pulse wave and the properties of the perfusion medium on the intra-aneurysmal circulation were investigated. As shown previously, the inflow into the aneurysm arose from the downstream lip and was directed toward the center of the fundus. Backflow to the parent vessel took place along the walls of the fundus. With non-pulsatile perfusion, flow velocities in the center of the standardized aneurysms varied between 0.4 and 2% of the maximum velocity in the parent vessel. With pulsatile perfusion, flow velocities in the center of the fundus ranged between 8 and 13% of the flow velocity in the axis of the parent vessel. Flow velocities in the aneurysms were slower with a polymer suspension with blood-like properties compared to a glycerol/water solution. Flow velocity measurements near the aneurysmal wall allowed the estimation of the shear stresses at critical locations. The maximum shear stresses at the downstream lip of the aneurysm were in the range of the stresses measured at the flow divider of an arterial bifurcation. The present results suggest that in human saccular aneurysms intra-aneurysmal flow and shear stress on the wall are directly related to the pulsatility of perfusion, i.e. the systolic/diastolic pressure difference and that the tendency to spontaneous thrombosis depends on the viscoelastic properties of the blood, namely the hematocrit.  相似文献   

11.
Cerebral aneurysms are a common cause of death and disability. Of all the cardiovascular diseases, aneurysms are perhaps the most strongly linked with the local fluid mechanic environment. Aside from early in vivo clinical work that hinted at the possibility of high-frequency intra-aneurysmal velocity oscillations, flow in cerebral aneurysms is most often assumed to be laminar. This work investigates, through the use of numerical simulations, the potential for disturbed flow to exist in the terminal aneurysm of the basilar bifurcation. The nature of the disturbed flow is explored using a series of four idealized basilar tip models, and the results supported by four patient specific terminal basilar tip aneurysms. All four idealized models demonstrated instability in the inflow jet through high frequency fluctuations in the velocity and the pressure at approximately 120?Hz. The instability arises through a breakdown of the inflow jet, which begins to oscillate upon entering the aneurysm. The wall shear stress undergoes similar high-frequency oscillations in both magnitude and direction. The neck and dome regions of the aneurysm present 180 deg changes in the direction of the wall shear stress, due to the formation of small recirculation zones near the shear layer of the jet (at the frequency of the inflow jet oscillation) and the oscillation of the impingement zone on the dome of the aneurysm, respectively. Similar results were observed in the patient-specific models, which showed high frequency fluctuations at approximately 112 Hz in two of the four models and oscillations in the magnitude and direction of the wall shear stress. These results demonstrate that there is potential for disturbed laminar unsteady flow in the terminal aneurysm of the basilar bifurcation. The instabilities appear similar to the first instability mode of a free round jet.  相似文献   

12.
Pulsatile flow fields in a cerebrovascular side-wall aneurysm model with a wide ostium after stenting are presented in terms of particle tracking velocimetry measurements and flow visualization. Among the stent parameters the shape, helix versus mesh, was selected to study its effect on the changes of intraaneurysmal hemodynamics for the reference of minimally invasive endovascular aneurysm treatment. The blocking ratio of the stents was fixed at 30%. The Womersley number was 3.9 and the mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 600, 850, and 300, respectively. Four consecutive flow-rate phases were selected to characterize the intra-aneurysmal flow. The results are characterized in terms of velocity vector field, regional average velocity, and intra-aneurysmal vorticity/circulation/wall shear stress. It is found that the hemodynamic features inside the aneurysm alter markedly with the shape of the stent and the size of the orifice. Both stents investigated induce favorable changes in the intra-aneurysmal flow stasis as well as direction and undulation of wall shear stresses. A comparison of the results of the helix to mesh stent shows that the former is more favorable for endovascular treatment.  相似文献   

13.
本文报道用“静脉囊镶嵌技术·制成犬的囊状动脉瘤模型。18个模型(6个单侧型,6个分叉型,6个末梢型)造型后2周经IA DSA检查。本模型在分型、血流动力学改变方面与人类囊状脑动脉瘤类似。不同类型的动脉瘤模型既有相同的血流动力学特征,又有各自的特点,这与动脉瘤与载瘤动脉的角度有关。我们认为该模型可应用于研究动脉瘤的血流动力学与血管内栓塞治疗。  相似文献   

14.
Background: CFD has been used to assess intra-aneurysmal hemodynamics. Nevertheless, the lack of patient-specific flow information has triggered the possibility of implementing a wide variety of physiological flow conditions. Due to these uncertainties in the patient flow conditions, the normalization of the intra-aneurysmal hemodynamics is generally conducted.  相似文献   

15.
It recently has been shown that the aspect ratio (dome/neck) of an aneurysm correlates well with intraaneurysmal blood flow, and the aneurysms of aspect ratio larger than 1.6 carry a higher risk of rupture. We examined the effect of aspect ratio (AR) on intra-aneurysmal flow based on flow visualization studies using various aneurysm models. A flow visualization study with the milk tracing method was performed on ten different aneurysm models, and we calculated the mean transit time (MTT) for each aneurysm model at different flow ratios into the branches. The AR and the MTT for each aneurysm were significantly correlated. It was confirmed that the larger the AR was, the longer the MTT became. An asymetric flow ratio induced smooth circulating flow along the aneurysm wall, but a symmetric flow ratio raised complexed vortices at the neck, resulting in longer MTT for the aneurysm model. Aneurysms growing more than AR 2.0 showed very slow flow, and the bleb at the 2.0 AR aneurysm model showed almost stagnant flow, which is considered a characteristic morphology for rupture. Hemodynamics in the aneurysm larger than AR 2.0 and an accompanying daughter aneurysm at the dome definitely contribute to thrombus formation.  相似文献   

16.
During the last years endovascular aneurysm repair (EVAR) became the elective treatment for abdominal aortic aneurysms (AAAs) thanks to lower mortality and morbidity rates than open surgery. In face of these advantages, stent-graft performances are still clinically suboptimal. In particular, post-surgical complications derive from device migration as a consequence of the hemodynamic forces acting on the endograft. In this regard, while the importance of hemodynamic surface forces is well recognized, the role of the in-stent flow is still unclear. Here we hypothesize that in-stent helical blood flow patterns might influence the distribution of the displacement forces (DFs) acting on the stent-graft and, ultimately, the risk of stent migration. To test this hypothesis, the hemodynamics of 20 post-EVAR models of patients treated with two different commercial endografts was analyzed using computational hemodynamics.The main findings of the study indicate that: (1) helical flow intensity decreases the risk of endograft migration, as given by an inverse correlation between helicity intensity (h2) and time-averaged displacement forces (TADFs) (p < 0.05); (2) unbalanced counter-rotating helical structures in the legs of the device contribute, in particular along the systole, to significantly suppress TADFs (p < 0.01); (3) as expected, helical flow intensity is positively correlated with pressure drop and resistance to flow (p < 0.001). The findings of this study suggest that a design strategy promoting in-stent helical flow structures could contribute to minimize the risk of migration of implanted EVAR devices.  相似文献   

17.
Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CFD simulations were then carried out using a well-validated, in-house solver, based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CFD simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement between PIV and CFD suggests that CFD can reliably predict the details of the intra-aneurysmal flow dynamics observed in anatomically realistic in vitro models. Nevertheless, given the various modeling assumptions, this does not prove that they are mimicking the actual in vivo hemodynamics, and so validations against in vivo data are encouraged whenever possible.  相似文献   

18.
The governing equations for pulsatile fluid flow were solved in their finite volume formulation in order to simulate blood flow in a variety of three-dimensional aneurysm geometries. The influence of geometric factors on flow patterns and fluid mechanical forces was studied with the goal of identifying the risk of aneurysm rupture. Aneurysm morphology was characterized by quantitative shape indices reflecting the three dimensionality of the vasculature derived from clinical studies. Recirculation zones and secondary flows were observed in aneurysms and arteries. Regions of extreme and alternating shear stress were observed and identified as sites for potential aneurysm rupture. The ellipticity of an aneurysm was observed to be strongly correlated with wall shear stress at the aneurysm fundus, while its non-sphericity, volume, and degree of undulation were more weakly correlated.  相似文献   

19.
One possible treatment for cerebral aneurysms is a porous tubular structure, similar to a stent, called a flow diverter. A flow diverter can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. This excludes the aneurysm from the parent artery and returns the flow of blood to normal. Previous flow diverting devices have been analyzed to determine optimal characteristics, such as braiding angle and wire diameter. From this information, a new optimized device was designed to achieve equivalent hemodynamic performance to the previous best device, but with better longitudinal flexibility to preserve physiological arterial configuration. The new device was tested in vitro in an elastomeric replica of the rabbit elastase induced aneurysm model and is now in the process of being tested in vivo. Particle image velocimetry was utilized to determine the velocity field in the plane of symmetry of the model under pulsatile flow conditions. Device hemodynamic performance indices such as the hydrodynamic circulation were evaluated from the velocity fields. Comparison of these indices with the previous best device and a control shows that the significant design changes of the device did not change its hemodynamic attributes (p?>?0.05).  相似文献   

20.
The strength and direction of blood flow into and within a cerebral aneurysm are important issues in developing effective interventional strategies to stabilize the aneurysm. We tested the hypothesis that there are significant major hemodynamic features that are common to many aneurysm flows of the type studied here. This was investigated by performing computational fluid dynamic simulations of flow near 7 cerebral aneurysms using geometrical data obtained from clinical CT scans. Our numerical simulations of flow across the ostium plane of an aneurysm show that in many cases there is relatively stable flow structure that is maintained over the phase of the pulsatile flow cycle. The two main features of this flow are (1) quasi-permanent regions of flow influx and efflux across the ostium plane exist, separated by a “virtual boundary”, and (2) a helical vortex flow pattern within the aneurismal sac with swirl in two orthogonal cross-sectional planes. These numerical observations are consistent with in vitro experimental data from ultrasound color-Doppler velocimetry and other numerical and experimental studies. The observed flow patterns are found to occur in different types of aneurysms (bifurcation and sidewall), and can persist even after flow parameters are perturbed beyond the normal range of physiological flow conditions. These results suggest that in many cases, major aspects of the behavior of aneurismal hemodynamics for important classes of aneurysms can be learned from an analysis of steady, non-pulsatile flow, which is simpler and faster to simulate than time-dependent, pulsatile flow. An understanding of this fluid dynamical behavior may also prove useful in the design of stents, coils, and various other endovascular flow diverting devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号