首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVES: Many flow-cytometric cell characterization methods require costly markers and colour reagents. We present here a novel device for cell discrimination based on impedance measurement of electrical cell properties in a microfluidic chip, without the need of extensive sample preparation steps and the requirement of labelling dyes. MATERIALS AND METHODS, RESULTS: We demonstrate that in-flow single cell measurements in our microchip allow for discrimination of various cell line types, such as undifferentiated mouse fibroblasts 3T3-L1 and adipocytes on the one hand, or human monocytes and in vitro differentiated dendritic cells and macrophages on the other hand. In addition, viability and apoptosis analyses were carried out successfully for Jurkat cell models. Studies on several species, including bacteria or fungi, demonstrate not only the capability to enumerate these cells, but also show that even other microbiological life cycle phases can be visualized. CONCLUSIONS: These results underline the potential of impedance spectroscopy flow cytometry as a valuable complement to other known cytometers and cell detection systems.  相似文献   

2.
Microfluidic chips have been widely used to probe the mechanical properties of cells, which are recognized as a promising label-free biomarker for some diseases. In our previous work (Ye et al., 2018), we have studied the relationships between the transit time and the mechanical properties of a cell flowing through a microchannel with a single constriction, which potentially forms a basis for a microfluidic chip to measure cell’s mechanical properties. Here, we investigate this microfluidic chip design and examine its potential in performances. We first develop the simultaneous dependence of the transit time on both the shear and bending moduli of a cell, and then examine the chip sensitivity with respect to the cell mechanical properties while serializing a single constriction along the flow direction. After that, we study the effect of the flow velocity on the transit time, and also test the chip’s ability to identify heterogeneous cells with different mechanical properties. The results show that the microfluidic chip designed is capable of identifying heterogeneous cells, even when only one unhealthy cell is included. The serialization of chip can greatly increase the chip sensitivity with respect to the mechanical properties of cells. The flow with a higher velocity helps in not only promoting the chip throughput, but also in providing more accurate transit time measurements, because the cell prefers a symmetric deformation under a high velocity.  相似文献   

3.
The key benefits of Lab-on-a-Chip technology are substantial time savings via an automation of lab processes, and a reduction in sample and reagent volumes required to perform analysis. In this article we present a new implementation of cell assays on disposable microfluidic chips. The applications are based on the controlled movement of cells by pressure-driven flow in microfluidic channels and two-color fluorescence detection of single cells. This new technology allows for simple flow cytometric studies of cells in a microfluidic chip-based system. In addition, we developed staining procedures that work “on-chip,” thus eliminating time-consuming washing steps. Cells and staining-reagents are loaded directly onto the microfluidic chip and analysis can start after a short incubation time. These procedures require only a fraction of the staining reagents generally needed for flow cytometry and only 30,000 cells per sample, demonstrating the advantages of microfluidic technology. The specific advantage of an on-chip staining reaction is the amount of time, cells, and reagents saved, which is of great importance when working with limited numbers of cells, e.g., primary cells or when needing to perform routine tests of cell cultures as a quality control step. Applications of this technology are antibody staining of proteins and determination of cell transfection efficiency by GFP expression. Results obtained with microfluidic chips, using standard cell lines and primary cells, show good correlation with data obtained using a conventional flow cytometer.  相似文献   

4.
Zhang C  Xing D 《Nucleic acids research》2007,35(13):4223-4237
The possibility of performing fast and small-volume nucleic acid amplification and analysis on a single chip has attracted great interest. Devices based on this idea, referred to as micro total analysis, microfluidic analysis, or simply ‘Lab on a chip’ systems, have witnessed steady advances over the last several years. Here, we summarize recent research on chip substrates, surface treatments, PCR reaction volume and speed, architecture, approaches to eliminating cross-contamination and control and measurement of temperature and liquid flow. We also discuss product-detection methods, integration of functional components, biological samples used in PCR chips, potential applications and other practical issues related to implementation of lab-on-a-chip technologies.  相似文献   

5.
High-throughput single cell analysis is required for understanding and predicting the complex stochastic responses of individual cells in changing environments. We have designed a microfluidic device consisting of parallel, independent channels with cell-docking structures for the formation of an array of individual cells. The microfluidic cell array was used to quantify single cell responses and the distribution of response patterns of calcium channels among a population of individual cells. In this device, 15 cell-docking units in each channel were fabricated with each unit containing 5 sandbag structures, such that an array of individual cells was formed in 8 independent channels. Single cell responses to different treatments in different channels were monitored in parallel to study the effects of the specific activator and inhibitor of the Ca2+ release-activated Ca2+ (CRAC) channels. Multichannel detection was performed to obtain the response patterns of the population of cells within this single cell array. The results demonstrate that it is possible to acquire single cell features in multichannels simultaneously with passive structural control, which provides an opportunity for high-throughput single cell response analysis in a microfluidic chip.  相似文献   

6.
Bone cells exist in a complex environment where they are constantly exposed to numerous dynamic biochemical and mechanical stimuli. These stimuli regulate bone cells that are involved in various bone disorders, such as osteoporosis. Knowledge of how these stimuli affect bone cells have been utilised to develop various treatments, such as pharmaceuticals, hormone therapy, and exercise. To investigate the role that bone loading has on these disorders in vitro, bone cell mechanotransduction studies are typically performed using parallel plate flow chambers (PPFC). However, these chambers do not allow for dynamic cellular interactions among different cell populations to be investigated. We present a microfluidic approach that exposes different cell populations, which are located at physiologically relevant distances within adjacent channels, to different levels of fluid shear stress, and promotes cell-cell communication between the different channels. We employed this microfluidic system to assess mechanically regulated osteocyte-osteoclast communication. Osteoclast precursors (RAW264.7 cells) responded to cytokine gradients (e.g., RANKL, OPG, PGE-2) developed by both mechanically stimulated (fOCY) and unstimulated (nOCY) osteocyte-like MLO-Y4 cells simultaneously. Specifically, we observed increased osteoclast precursor cell densities and osteoclast differentiation towards nOCY. We also used this system to show an increased mechanoresponse of osteocytes when in co-culture with osteoclasts. We envision broad applicability of the presented approach for microfluidic perfusion co-culture of multiple cell types in the presence of fluid flow stimulation, and as a tool to investigate osteocyte mechanotransduction, as well as bone metastasis extravasation. This system could also be applied to any multi-cell population cross-talk studies that are typically performed using PPFCs (e.g. endothelial cells, smooth muscle cells, and fibroblasts).  相似文献   

7.
Nowadays numerous microfluidic systems are being developed to address a variety of clinical problems. Latest advances in microfluidic technology are promising to revolutionize the detection of pathogens in vivo through the development of integrated lab-on-chip devices. Such microfabricated systems will undertake all steps in sample analysis from collection and preparation to molecular detection. Micro total analysis systems are suitable candidates for point of care diagnostics due to small size, low cost production and enabled portability. The work here presented aimed the use of microfluidic platforms to identify and manipulate bovine red blood cells infected by the protozoan parasite Babesia bovis. A microfabricated device based on impedance spectroscopy was used for single cell discrimination and its sensitivity and applicability as a diagnostic method for bovine babesiosis was studied. Furthermore, manipulation and sorting of normal and infected red blood cells was performed on a dielectrophoresis based microfabricated cell cytometer. Single cell analysis of normal and B. bovis infected red blood cells was performed by electrorotation and dielectric parameters such as permittivities and conductivities of the cellular membrane and cytoplasm were determined.  相似文献   

8.
Miniaturized microfluidic systems provide simple and effective solutions for low-cost point-of-care diagnostics and high-throughput biomedical assays. Robust flow control and precise fluidic volumes are two critical requirements for these applications. We have developed microfluidic chips featuring elastomeric polydimethylsiloxane (PDMS) microvalve arrays that: 1) need no extra energy source to close the fluidic path, hence the loaded device is highly portable; and 2) allow for microfabricating deep (up to 1 mm) channels with vertical sidewalls and resulting in very precise features.The PDMS microvalves-based devices consist of three layers: a fluidic layer containing fluidic paths and microchambers of various sizes, a control layer containing the microchannels necessary to actuate the fluidic path with microvalves, and a middle thin PDMS membrane that is bound to the control layer. Fluidic layer and control layers are made by replica molding of PDMS from SU-8 photoresist masters, and the thin PDMS membrane is made by spinning PDMS at specified heights. The control layer is bonded to the thin PDMS membrane after oxygen activation of both, and then assembled with the fluidic layer. The microvalves are closed at rest and can be opened by applying negative pressure (e.g., house vacuum). Microvalve closure and opening are automated via solenoid valves controlled by computer software.Here, we demonstrate two microvalve-based microfluidic chips for two different applications. The first chip allows for storing and mixing precise sub-nanoliter volumes of aqueous solutions at various mixing ratios. The second chip allows for computer-controlled perfusion of microfluidic cell cultures.The devices are easy to fabricate and simple to control. Due to the biocompatibility of PDMS, these microchips could have broad applications in miniaturized diagnostic assays as well as basic cell biology studies.  相似文献   

9.
Modern microfabrication and microfluidic technologies offer new opportunities in the design and fabrication of miniaturized cell culture systems for online monitoring of living cells. We used laser micromachining and thermal bonding to fabricate an optically transparent, low-cost polymeric chip for long-term online cell culture observation under controlled conditions. The chip incorporated a microfluidic flow equalization system, assuring uniform perfusion of the cell culture media throughout the cell culture chamber. The integrated indium-tin-oxide heater and miniature temperature probe linked to an electronic feedback system created steady and spatially uniform thermal conditions with minimal interference to the optical transparency of the chip. The fluidic and thermal performance of the chip was verified by finite element modeling and by operation tests under fluctuating ambient temperature conditions. HeLa cells were cultured for up to 2 weeks within the cell culture chip and monitored using a time-lapse video recording microscopy setup. Cell attachment and spreading was observed during the first 10-20 h (lag phase). After approximately 20 h, cell growth gained exponential character with an estimated doubling time of about 32 h, which is identical to the observed doubling time of cells grown in standard cell culture flasks in a CO2 incubator.  相似文献   

10.
Cultured neuronal networks (CNNs) are a robust model to closely investigate neuronal circuits’ formation and monitor their structural properties evolution. Typically, neurons are cultured in plastic plates or, more recently, in microfluidic platforms with potentially a wide variety of neuroscience applications. As a biological protocol, cell culture integration with a microfluidic system provides benefits such as accurate control of cell seeding area, culture medium renewal, or lower exposure to contamination. The objective of this report is to present a novel neuronal network on a chip device, including a chamber, fabricated from PDMS, vinyl and glass connected to a microfluidic platform to perfuse the continuous flow of culture medium. Network growth is compared in chips and traditional Petri dishes to validate the microfluidic chip performance. The network assessment is performed by computing relevant topological measures like the number of connected neurons, the clustering coefficient, and the shortest path between any pair of neurons throughout the culture's life. The results demonstrate that neuronal circuits on a chip have a more stable network structure and lifespan than developing in conventional settings, and therefore this setup is an advantageous alternative to current culture methods. This technology could lead to challenging applications such as batch drug testing of in vitro cell culture models. From the engineering perspective, a device's advantage is the chance to develop custom designs more efficiently than other microfluidic systems.  相似文献   

11.
The investigation of cellular processes and gene regulatory networks within living cells requires the development of improved technology for dynamic, single cell imaging. Here, we demonstrate a microfluidic system capable of mechanical trapping of yeast cells with continuous flow and flow switching capability during time-lapse high magnification fluorescence imaging. The novel functionality of the system was validated by observing the response of pheromone-induced expression of GFP in Saccharomyces cerevisiae.  相似文献   

12.
The study of the dielectric properties of micrometer- or nanometer-scale particles is of particular interest in present-day applications of biomedical engineering. Electrokinetics utilises electrically energised microelectrode structures within microfluidic chambers to noninvasively probe the physiological structure of live cancer cells. A system is described that combines the three complementary techniques of dielectrophoresis (DEP), travelling wave dielectrophoresis (TWD) and electrorotation (ROT) for the first time on a single, integrated chip (3 x 6 mm). The chip employs planar microelectrode arrays fabricated on a silicon substrate to facilitate the synthesis of the various nonuniform electric fields required for the controlled manipulation, measurement and characterization of mammalian cells. A study of the dielectric properties of human malignant cells (Daudi and NCI-H929) was performed to demonstrate the potential and the versatility of the system in providing a fully programmable microsystem.  相似文献   

13.
Sample flow switching techniques on microfluidic chips   总被引:1,自引:0,他引:1  
This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.  相似文献   

14.
Although the recent advances in stem cell engineering have gained a great deal of attention due to their high potential in clinical research, the applicability of stem cells for preclinical screening in the drug discovery process is still challenging due to difficulties in controlling the stem cell microenvironment and the limited availability of high-throughput systems. Recently, researchers have been actively developing and evaluating three-dimensional (3D) cell culture-based platforms using microfluidic technologies, such as organ-on-a-chip and organoid-on-a-chip platforms, and they have achieved promising breakthroughs in stem cell engineering. In this review, we start with a comprehensive discussion on the importance of microfluidic 3D cell culture techniques in stem cell research and their technical strategies in the field of drug discovery. In a subsequent section, we discuss microfluidic 3D cell culture techniques for high-throughput analysis for use in stem cell research. In addition, some potential and practical applications of organ-on-a-chip or organoid-on-a-chip platforms using stem cells as drug screening and disease models are highlighted.  相似文献   

15.
We have developed a microfluidic platform modeled after the physiologic microcirculation for multiplexed tissue-like culture and high-throughput analysis. Each microfabricated culture unit consisted of three functional components: a 50 microm wide cell culture pocket, an artificial endothelial barrier with 2 microm pores, and a nutrient transport channel. This configuration enabled a high density of cancer cells to be maintained for over 1 week in a solid tumor-like morphology when fed with continuous flow. The microfluidic chip contained 16 parallel units for "flow cell" based experiments where live cells were exposed to a soluble factor and analyzed via fluorescence microscopy or flow-through biochemistry. Each fluidically independent tissue unit contained approximately 500 cells fed with a continuous flow of 10 nL/min. As a demonstration, the toxicity profile of the anti-cancer drug paclitaxel was collected on HeLa cells cultured in the microfluidic format and compared with a 384-well dish for up to 5 days of continuous drug exposure.  相似文献   

16.
A nanoliter-scale nucleic acid processor with parallel architecture   总被引:6,自引:0,他引:6  
The purification of nucleic acids from microbial and mammalian cells is a crucial step in many biological and medical applications. We have developed microfluidic chips for automated nucleic acid purification from small numbers of bacterial or mammalian cells. All processes, such as cell isolation, cell lysis, DNA or mRNA purification, and recovery, were carried out on a single microfluidic chip in nanoliter volumes without any pre- or postsample treatment. Measurable amounts of mRNA were extracted in an automated fashion from as little as a single mammalian cell and recovered from the chip. These microfluidic chips are capable of processing different samples in parallel, thereby illustrating how highly parallel microfluidic architectures can be constructed to perform integrated batch-processing functionalities for biological and medical applications.  相似文献   

17.
A major limitation to yeast aging study has been the inability to track mother cells and observe molecular markers during the aging process. The traditional lifespan assay relies on manual micro-manipulation to remove daughter cells from the mother, which is laborious, time consuming, and does not allow long term tracking with high resolution microscopy. Recently, we have developed a microfluidic system capable of retaining mother cells in the microfluidic chambers while removing daughter cells automatically, making it possible to observe fluorescent reporters in single cells throughout their lifespan. Here we report the development of a new generation of microfluidic device that overcomes several limitations of the previous system, making it easier to fabricate and operate, and allowing functions not possible with the previous design. The basic unit of the device consists of microfluidic channels with pensile columns that can physically trap the mother cells while allowing the removal of daughter cells automatically by the flow of the fresh media. The whole microfluidic device contains multiple independent units operating in parallel, allowing simultaneous analysis of multiple strains. Using this system, we have reproduced the lifespan curves for the known long and short-lived mutants, demonstrating the power of the device for automated lifespan measurement. Following fluorescent reporters in single mother cells throughout their lifespan, we discovered a surprising change of expression of the translation elongation factor TEF2 during aging, suggesting altered translational control in aged mother cells. Utilizing the capability of the new device to trap mother-daughter pairs, we analyzed mother-daughter inheritance and found age dependent asymmetric partitioning of a general stress response reporter between mother and daughter cells.  相似文献   

18.
We have developed the first fully integrated microfluidic system for DNA sequencing-by-synthesis. Using this chip and fluorescence detection, we have reliably sequenced up to 4 consecutive bps. The described sequencer can be integrated with other microfluidic components on the same chip to produce true lab-on-a-chip technology. The surface chemistry that was designed to anchor the DNA to elastomeric microchannels is useful in a broad range of studies and applications.  相似文献   

19.
基于微流控的真菌单细胞捕获和培养   总被引:1,自引:1,他引:0  
【背景】真菌单细胞培养在研究细胞异质性及细胞生长特性等方面十分重要,因此需要建立简单便捷的方法对真菌单细胞进行培养与观察。【目的】基于微流控建立一种真菌单细胞的捕获及培养方法,同时直观地对单细胞进行定位和实时观察。【方法】利用L-edit设计芯片图案并利用等离子键合的方法制备微流控芯片;通过注射泵将红酵母菌溶液及里氏木霉孢子溶液进样以实现单细胞捕获;采用台盼蓝染色法测定酵母细胞的存活率;利用显微镜对酵母单细胞及木霉孢子的萌发、生长、繁殖过程进行观察。【结果】所制备的芯片形状完好,可实现酵母或孢子的单细胞捕获;酵母的捕获率为25.00%±1.38%;分别于0、2、4、6h对酵母进行观察,可看到酵母出芽过程;培养至48h,芯片上酵母细胞的存活率与游离培养条件下的存活率无显著性差异;分别于0、3、6、9 h对单个孢子进行观察,可以看到孢子萌发以及菌丝生长情况,且直至120h菌丝仍在生长。【结论】设计并制备了一种用于真菌单细胞捕获及定位培养的微流控芯片,这是此种芯片在真菌单细胞培养中的首次应用。细胞可在此微流控芯片上正常生长至少2 d,并可实现5 d及更长时间的培养,此方法可对真菌单细胞进行直观、定位的实时观察,有望用于多种微生物单细胞的生理、遗传性状研究,以及原生质体融合育种研究。  相似文献   

20.
The uptake of microfluidics by the wider scientific community has been limited by the fabrication barrier created by the skills and equipment required for the production of traditional microfluidic devices. Here we present simple 3D printed microfluidic devices using an inexpensive and readily accessible printer with commercially available printer materials. We demonstrate that previously reported limitations of transparency and fidelity have been overcome, whilst devices capable of operating at pressures in excess of 2000 kPa illustrate that leakage issues have also been resolved. The utility of the 3D printed microfluidic devices is illustrated by encapsulating dental pulp stem cells within alginate droplets; cell viability assays show the vast majority of cells remain live, and device transparency is sufficient for single cell imaging. The accessibility of these devices is further enhanced through fabrication of integrated ports and by the introduction of a Lego®-like modular system facilitating rapid prototyping whilst offering the potential for novices to build microfluidic systems from a database of microfluidic components.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号