首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
As recently shown, different physiologically relevant lipid classes can easily be analyzed by matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI–TOF MS). In the present study the first application of MALDI–TOF for the quantitative analysis of diacylglycerols is described. It is shown that the use of a suitable reference sample enables the quantification of diacylglycerols up to the picomolar range. The best reproducibility of quantitative results for diacylglycerols was obtained using a matrix of 2,5-dihydroxybenzoic acid in ethylacetate and incorporation of an internal standard of the same lipid class. A moderate laser power was used, resulting in a very low extent of fragmentation, allowing a quantification by using solely the highest signal arising from sodium adduct formation of diacylglycerols. A linear correlation between peak intensity and lipid concentration over one order of magnitude was found. The applicability of this new technique for the analysis of other lipids like phosphatidylcholines is also discussed.  相似文献   

2.
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive.  相似文献   

3.
A method is described for the quantitative determination of peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Known limitations imposed by crystal heterogeneity, peptide ionization differences, data handling, and protein quantification with MALDI-TOF mass spectrometry are addressed in this method with a "seed crystal" protocol for analyte-matrix formation, the use of internal protein standards, and a software package called maldi_quant. The seed crystal protocol, a new variation of the fast-evaporation method, minimizes crystal heterogeneity and allows for consistent collection of protein spectra. The software maldi_quant permits rapid and automated analysis of peak intensity data, normalization of peak intensities to internal standards, and peak intensity deconvolution and estimation for vicinal peaks. Using insulin proteins in a background of other unrelated peptides, this method shows an overall coefficient of variance of 4.4%, and a quantitative working range of 0.58-37.5 ng bovine insulin per spot. Coupling of this methodology to powerful analytical procedures such as immunoprecipitation is likely to lead to the rapid and reliable quantification of biologically relevant proteins and their closely related variants.  相似文献   

4.
The DNA of all organisms is persistently damaged by endogenous reactive molecules. Most of the single-base endogenous damage is repaired through the base excision repair (BER) pathway that is initiated by members of the DNA glycosylase family. Although the BER pathway is often considered to proceed through a common abasic site intermediate, emerging evidence indicates that there are likely distinct branches reflected by the multitude of chemically different 3′ and 5′ ends generated at the repair site. In this study, we have applied matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF–MS) to the analysis of model DNA substrates acted on by recombinant glycosylases. We examine the chemical identity of several possible abasic site and nicked intermediates generated by monofunctional and bifunctional glycosylases. Our results suggest that the intermediate from endoIII/Nth might not be a simple β-elimination product as described previously. On the basis of 18O incorporation experiments, we propose a new mechanism for the endoIII/Nth family of glycosylases that may resolve several of the previous controversies. We further demonstrate that the use of an array of lesion-containing oligonucleotides can be used to rapidly examine the substrate preferences of a given glycosylase. Some of the lesions examined here can be acted on by more than one glycosylase, resulting in a spectrum of damaged intermediates for each lesion, suggesting that the sequence and coordination of repair activities that act on these lesions may influence the biological outcome of damage repair.  相似文献   

5.
与传统的微生物鉴定技术相比,基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry, MALDI-TOF MS)是一种准确、可靠和快速的鉴定和分型的技术。本文通过检索近年来国内外相关研究论文,总结最新的研究进展,发现MALDI-TOF MS在临床病原微生物、食源性微生物以及环境微生物等鉴定中有较大的优势,加快了微生物鉴定的进程,同时探索该技术在新领域的最新进展和面临的挑战,以期为我国基质辅助激光解吸电离飞行时间质谱技术的发展提供参考。  相似文献   

6.
7.
Papac  DI; Briggs  JB; Chin  ET; Jones  AJ 《Glycobiology》1998,8(5):445-454
This report describes a convenient method for the rapid and efficient release of N-linked oligosaccharides from low microgram amounts of glycoproteins. A 96-well MultiScreen assay system containing a polyvinylidene difluoride (PVDF) membrane is employed to immobilize glycoproteins for subsequent enzymatic deglycosylation. Recombinant tissue-type plasminogen activator (rt-PA) is used to demonstrate the deglycosylation of 0.1-50 micrograms of a glycoprotein. This method enabled the recovery of a sufficient amount of N-linked oligosaccharides released enzymatically with peptide N-glycosidase F (PNGaseF) from as little as 0.5 microgram rt-PA for subsequent analysis by matrix-assisted laser desorption/ionization time-of-flight (MALDI- TOF) mass spectrometry. The immobilization of rt-PA to the PVDF membrane did not sterically inhibit the PNGaseF-mediated release of oligosaccharides from rt-PA as determined by tryptic mapping experiments. Comparison of the oligosaccharides released from 50 micrograms of rt-PA by either the 96-well plate method or by a standard solution digestion procedure showed no significant differences in the profiles obtained by high-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD). Both neutral and sialylated oligosaccharide standards spiked into wells were recovered equally as determined by HPAEC-PAD. One advantage of this approach is that reduction and alkylation can be performed on submicrogram amounts of glycoproteins with easy removal of reagents prior to PNGaseF digestion. In addition, this method allows 60 glycoprotein samples to be deglycosylated in 1 day with MALDI-TOF or HPAEC-PAD analysis being performed on the following day.   相似文献   

8.
In view of the fact that memory effects associated with instrument calibration hinder the use of many mass-to-charge (m/z) ratios and tuning standards, identification of robust, comprehensive, inexpensive, and memory-free calibration standards is of particular interest to the mass spectrometry community. Glucose and its isomers are known to have a residue mass of 162.05282 Da; therefore, both linear and branched forms of polyhexose oligosaccharides possess well-defined masses, making them ideal candidates for mass calibration. Using a wide range of maltooligosaccharides (MOSs) derived from commercially available beers, ions with m/z ratios from approximately 500 to 2500 Da or more have been observed using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) and time-of-flight mass spectrometry (TOF-MS). The MOS mixtures were further characterized using infrared multiphoton dissociation (IRMPD) and nano-liquid chromatography/mass spectrometry (nano-LC/MS). In addition to providing well-defined series of positive and negative calibrant ions using either electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI), the MOSs are not encumbered by memory effects and, thus, are well-suited mass calibration and instrument tuning standards for carbohydrate analysis.  相似文献   

9.
10.
Eight pyridylamino (PA) derivatives of fucose-containing oligosaccharides, which occur as free oligosaccharides in human milk and also are derived from glycosphingolipids, have been analyzed by high-performance liquid chromatography (HPLC) on normal-phase and reversed-phase columns, and by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Six out of eight PA-oligosaccharides were clearly separated by both normal- and reversed-phase HPLC at a column temperature of 40 degrees C, but two PA-oligosaccharides, lacto-N-fucopentaose II [Gal beta1-3(Fuc alpha1-4)GlcNAc beta1-3Gal beta1-4GIcPA] and lacto-N-fucopentaose III [Gal beta1-4(Fuc alpha1-3)GlcNAc beta1-3Gal beta1-4GIcPA], were not separated. The two unresolved PA-oligosaccharides were finally separated by reversed-phase HPLC at a column temperature of 11 degrees C. MALDI-TOF mass spectra of PA-oligosaccharides demonstrated pseudo-molecular ions as the predominant signals, therefore information about the molecular mass of each PA-oligosaccharide was easily obtained. Post-source decay (PSD) MALDI-TOF mass spectra of PA-oligosaccharides gave information about the carbohydrate sequences and carbohydrate species of each PA-oligosaccharide by detecting the ions responsible for the cleavage of the glycosidic bonds. The detection limits of the PA-oligosaccharides by HPLC, MALDI-TOF mass spectrometry, and PSD MALDI-TOF mass spectrometry were 20 fmol, 20 fmol, and 2 pmol, respectively. These results suggest that a system including HPLC and MALDI-TOF mass spectrometry or HPLC and PSD MALDI-TOF mass spectrometry is quite useful for the structural characterization of sub-pmol or pmol levels of fucose-containing oligosaccharides, and that these methods could be used for the analysis of various types of oligosaccharides derived from glycoproteins and glycosphingolipids.  相似文献   

11.
Quantitative matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) was applied for the determination of concentrations of low-molecular-weight (< 400Da) substrates and products of enzyme-catalyzed reactions. Isotope-labeled and fluorinated internal standards were used for the quantification. Automated quantitative MALDI-ToF MS analysis of quenched samples allowed the direct and simultaneous observation of time-dependent decrease of substrate concentration and increase of product concentration without any need for prepurification or desalting steps. The results showed good agreement with established but more elaborate analytical methods. MALDI-ToF MS thus is an interesting alternative tool for the determination of enzyme activities. Due to automated and miniaturized measurement it is especially suitable for the screening of biocatalysts.  相似文献   

12.
To evaluate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) as a tool for rapid identification of common clinical bacterial isolates, we analyzed 25 carefully selected isolates of pathogenic Escherichia coli (E. coli) and additional Enterobacteriaceae members. Organisms were prepared according to clinical microbiological protocols and analyzed with minimal additional processing. Spectra were reproducible from preparation to preparation and comprised 40-100 peaks primarily representing intracellular proteins with masses up to 25 kDa. Spectra of 14 genetically diverse bacteremic isolates of E. coli were compared with isolates representing other genera within the Enterobacteriaceae family. Using a new spectrum comparison algorithm, E. coli isolates were closely related to each other and were readily distinguishable from other Enterobacteriaceae, including Salmonella and Shigella. Presently, the methodology permits the analysis of 40 unknown isolates per hour per instrument. These results suggest that MALDI-ToF MS offers a rapid and reliable approach for performing phyloproteomics i.e., identification of unknown bacterial isolates based on similarities within protein biomarker databases.  相似文献   

13.
The capability of iTRAQ (isotope tags for relative and absolute quantification) reagents coupled with matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) as a qualitative and quantitative technique for the analysis of complicated protein pharmaceutical mixtures was evaluated. Mixtures of Somavert and Miacalcin with a small amount of bovine serum albumin (BSA) as an impurity were analyzed. Both Somavert and Miacalcin were qualitatively identified, and BSA was detected at levels as low as 0.8 mol%. Genotropin and Somavert were compared in a single experiment, and all of the distinct amino acid residues from the two proteins were readily identified. Four somatropin drug products (Genotropin, Norditropin, Jintropin, and Omnitrope) were compared using the iTRAQ/MALDI-MS method to determine the similarity between their primary structures and quantify the amount of protein in each product. All four product samples were well labeled and successfully compared when a filtration cleanup step preceded iTRAQ labeling. The quantitative accuracy of the iTRAQ method was evaluated. In all cases, the accuracy of experimentally determined protein ratios was higher than 90%, and the relative standard deviation (RSD) was less than 10%. The iTRAQ and global internal standard technology (GIST) methods were compared, and the iTRAQ method provided both higher sequence coverage and enhanced signal intensity.  相似文献   

14.
Cartilage extracellular matrix molecules synthesized and maintained by chondrocytes form a strong, elastic tissue functioning to cushion and protect the subchondral bone. Osteoarthritis is characterized by degradation of cartilage extracellular matrix molecules resulting in fibrillation, irreversible erosion, and eventual failure of the tissue. With recent interest in the degradation of cartilage extracellular matrix molecules, a need for more detailed structural information exists. Posttranslational modifications are believed to play a role in determining the susceptibility of these molecules to proteolytic degradation during the development of osteoarthritis. The purpose of this paper is to show how the application of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry to extracellular matrix protein and proteoglycan structure will help elucidate problems in extracellular matrix biochemistry. Methodological issues relating to the high molecular weight, polydispersity, and high degree of posttranslational modification of these molecules are discussed. MALDI-TOF mass spectrometry provides an improved level of detail for extracellular matrix protein and proteoglycan structure and is useful in addressing issues surrounding the causes of degradation during osteoarthritis.  相似文献   

15.
Different methods were established for monitoring the phospholipase A(2)(PLA(2)) activity but all of them are rather cumbersome and time consuming. In this paper we have investigated the suitability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the determination of the PLA(2) activity. Phosphatidylcholine (PC) was digested with pancreatic PLA(2) under different conditions, i.e., various Ca(2+), PC, and PLA(2) concentrations. The digestion products were analyzed by MALDI-TOF MS and the concentration of lysophosphatidylcholine (LPC)-generated upon PLA(2) digestion-was determined by the application of an internal standard (known concentration) and by a comparison of their signal-to-noise ratios. The results clearly demonstrate that the LPC concentration determined from the MALDI-TOF mass spectra correlates directly with the activity of the applied enzyme. Additionally, LPC concentration increased with an increase in Ca(2+), as well as in the PC concentration. A single MALDI-TOF mass spectrum provides immediate information on the digestion products as well as on the residual substrate without requirements for any previous derivatization. MALDI-TOF MS can be easily and simply applied for monitoring the PLA(2) activity and we assume that this method might also be useful for other types of phospholipases.  相似文献   

16.
A robust high-throughput single-nucleotide polymorphism (SNP) genotyping method is reported, which applies allele-specific extension to achieve allelic discrimination and uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to measure the natural molecular weight difference of oligonucleotides for determination of the base in a single-nucleotide polymorphic location. Tenfold PCR is performed successfully by carefully designing the primers and adjusting the conditions of PCR. In addition, two ways used for PCR product purification are compared and the matrix used in mass spectrometry for high-throughput oligonucleotide analysis is evaluated. The result here shows that the method is very effective and suitable for high-throughput genotyping of SNPs.  相似文献   

17.
18.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry – one of the most commonly used analytical tools in proteomics – for high-throughput analyses.  相似文献   

19.
Phosphoamino acid modifications on substrate proteins are critical components of protein kinase signaling pathways. Thus, diverse methodologies have been developed and applied to identify the sites of phosphorylated amino acids within proteins. Despite significant progress in the field, even the determination of phosphorylated residues in a given highly purified protein is not a matter of routine and can be difficult and time-consuming. Here we present a practicable approach that integrates into a liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry (LC–MALDI MS) workflow and allows localization and quantification of phosphorylated peptides on the MALDI target plate prior to MS analysis. Tryptic digests of radiolabeled proteins are fractionated by reversed-phase LC directly onto disposable MALDI target plates, followed by autoradiographic imaging. Visualization of the radiolabel enables focused analysis of selected spots, thereby accelerating the process of phosphorylation site mapping by decreasing the number of spectra to be acquired. Moreover, absolute quantification of the phosphorylated peptides is permitted by the use of appropriate standards. Finally, the manual sample handling is minimal, and consequently the risk of adsorptive sample loss is very low. Application of the procedure allowed the targeted identification of six novel autophosphorylation sites of AMP-activated protein kinase (AMPK) and displayed additional unknown phosphorylated peptide species not amenable to detection by MS. Furthermore, autoradiography revealed topologically inhomogeneous distribution of phosphorylated peptides within individual spots. However, accurate analysis of defined areas within single spots suggests that, rather than such quantitative differences, mainly the manner of matrix crystallization significantly affects ionization of phosphopeptides.  相似文献   

20.
Harvey DJ 《Proteomics》2005,5(7):1774-1786
This paper reviews methods for the analysis of N-linked glycans by mass spectrometry with emphasis on studies conducted at the Oxford Glycobiology Institute. Topics covered are the release of glycans from sodium dodecyl sulphate-polyacrylamide gel electrophoresis gels, their purification for analysis by mass spectrometry, methods based on matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization for producing fragment ions, and details of their fragmentation. MALDI mass spectrometry provided a rapid method for profiling neutral N-linked glycans as their [M + Na](+) ions which could be fragmented by collision-induced decomposition to give spectra containing both glycosidic and cross-ring fragments. Electrospray ionization mass spectrometry was more versatile in that it was relatively easy to change the type of ion that was formed and, furthermore, unlike MALDI, electrospray did not cause extensive loss of sialic acids from sialylated glycans. Negative ions formed by addition of anions such as chloride and, particularly, nitrate, to the electrospray solvent were stable and enabled singly charged ions to be obtained from larger glycans than was possible in positive ion mode. Fragmentation of negative ions followed specific pathways that defined structural details of the glycans that were difficult to obtain by classical methods such as exoglycosidase digestion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号