首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 17 毫秒
1.
There is a great desire to relate the patterns of endogenous peptides in blood to human disease and drug response. The best practices for the preparation of blood fluids for analysis are not clear and also relatively few of the peptides in blood have been identified by tandem mass spectrometry. We compared a number of sample preparation methods to extract endogenous peptides including C18 reversed phase, precipitation, and ultrafiltration. We examined the results of these sample preparation methods by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and liquid chromatography-tandem mass spectrometry (MS/MS) using MALDI-TOF/TOF and electrospray ionization-ion trap. Peptides from solid-phase extraction with C18 in the range of hundreds of femtomoles per spot were detected from the equivalent of 1 μL of serum by MALDI-TOF. We observed endogenous serum peptides from fibrinogen α- and β-chain, complement C3, α-2-HS-glycoprotein, albumin, serine (or cysteine) proteinase inhibitor, factor VIII, plasminogen, immunoglobulin, and other abundant blood proteins. However, we also recorded significant MS/MS spectra from tumor necrosis factor-α-, major histocompatibility complex-, and angiotensin-related peptides, as well as peptides from collagens and other low-abundance proteins. Amino acid substitutions were detected and a phosphorylated peptide was also observed. This is the first time the endogenous peptides of fetal serum have been examined by MS and where peptides from low-abundance proteins, phosphopeptides, and amino acid substitutions were detected.  相似文献   

2.
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.  相似文献   

3.
Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.  相似文献   

4.
Mass spectrometric methods were applied to determine the peptidome of the brain and thoracic ganglion of the Jonah crab (Cancer borealis). Fractions obtained by high performance liquid chromatography were characterized using MALDI-TOF MS and ESI-Q-TOF MS/MS. In total, 28 peptides were identified within the molecular mass range 750-3000Da. Comparison of the molecular masses obtained with MALDI-TOF MS with the calculated molecular masses of known crustacean peptides revealed the presence of at least nine allatostatins, three orcokinin precursor derived peptides, namely FDAFTTGFGHS, [Ala(13)]-orcokinin, and [Val(13)]-orcokinin, and two kinins, a tachykinin-related peptide and four FMRFamide-related peptides. Eight other peptides were de novo sequenced by collision induced dissociation on the Q-TOF system and yielded AYNRSFLRFamide, PELDHVFLRFamide or EPLDHVFLRFamide, APQRNFLRFamide, LNPFLRFamide, DVRTPALRLRFamide, and LRNLRFamide, which belong to the FMRFamide related peptide family, as well as NFDEIDRSGFA and NFDEIDRSSFGFV, which display high sequence similarity to peptide sequences within the orcokinin precursor of Orconectes limosus. Our paper is the first (neuro)peptidomic analysis of the crustacean nervous system.  相似文献   

5.
Integral membrane proteins are notoriously difficult to identify and analyze by mass spectrometry because of their low abundance and limited number of trypsin cleavage sites. Our strategy to address this problem is based on a novel technology for MALDI-MS peptide sample preparation that increases the success rate of membrane protein identification by increasing the sensitivity of the MALDI-TOF system. For this, we used sample plates with predeposited matrix spots of CHCA crystals prepared by vacuum sublimation onto an extremely low wettable (ultraphobic) surface. In experiments using standard peptides, an up to 10-fold gain of sensitivity was found for on-chip preparations compared with classical dried-droplet preparations on a steel target. In order to assess the performance of the chips with membrane proteins, three model proteins (bacteriorhodopsin, subunit IV(a) of ATP synthase, and the cp47 subunit from photosystem II) were analyzed. To mimic realistic analysis conditions, purified proteins were separated by SDS-PAGE and digested with trypsin. The digest MALDI samples were prepared either by dried-droplet technique on steel plates using CHCA as matrix, or applied directly onto the matrix spots of the chip surface. Significantly higher signal-to-noise ratios were observed for all of the spectra resulting from on-chip preparations of different peptides.In a second series of experiments, the membrane proteome of Rhodococcus jostii RHA1 was investigated by AIEC/SDS-PAGE in combination with MALDI-TOF MS/MS. As in the first experiments, Coomassie-stained SDS-PAGE bands were digested and the two different preparation methods were compared. For preparations on the Mass·Spec·Turbo Chip, 43 of 60 proteins were identified, whereas only 30 proteins were reliably identified after classical sample preparation. Comparison of the obtained Mascot scores, which reflect the confidence level of the protein identifications, revealed that for 70% of the identified proteins, higher scores were obtained by on-chip sample preparation. Typically, this gain was a consequence of higher sequence coverage due to increased sensitivity.  相似文献   

6.
The combination of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), in-gel enzymatic digestion of proteins separated by two-dimensional gel electrophoresis and searches of molecular weight in peptide-mass databases is a powerful and well established method for protein identification in proteomics analysis. For successful protein identification by MALDI-TOF mass spectrometry of peptide mixtures, critical parameters include highly specific enzymatic cleavage, high mass accuracy and sufficient numbers and sequence coverage of the peptides which can be analyzed. For in-gel digestion with trypsin, the method employed should be compatible both with enzymatic cleavage and subsequent MALDI-TOF MS analysis. We report here an improved method for preparation of peptides for MALDI-TOF MS mass fingerprinting by using volatile solubilizing agents during the in-gel digestion procedure. Our study clearly demonstrates that modification of the in-gel digestion protocols by addition of dimethyl formamide (DMF) or a mixture of DMF/N,N-dimethyl acetamide at various concentrations can significantly increase the recovery of peptides. These higher yields of peptides resulted in more effective protein identification.  相似文献   

7.
The immature core protein (p23, residues 1 to 191) of hepatitis C virus undergoes posttranslational modifications including intramembranous proteolysis within its C-terminal signal sequence by signal peptide peptidase to generate the mature form (p21). In this study, we analyzed the cleavage site and other amino acid modifications that occur on the core protein. To produce the posttranslationally modified core protein, we used a baculovirus-insect cell expression model system. As previously reported, p23 is processed to form p21 in insect as well as in mammalian cells. p21 was found to be associated with the cytoplasmic membrane, and its significant portion behaved as an integral membrane protein. The protein was purified from the membrane by a simple and unique procedure on the basis of its membrane-binding properties and solubility in detergents. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of purified p21 showed that the average molecular mass (m/z 19,307) of its single-charged ion differs by m/z 1,457 from that calculated for p23. To determine the posttranslational modifications, tryptic p21 peptides were analyzed by MALDI-TOF MS. We found three peptides that did not match the theoretically derived peptides of p23. Analysis of these peptides by MALDI-TOF tandem MS revealed that they correspond to N-terminal peptides (residues 2 to 9 and 2 to 10) starting with alpha-N-acetylserine and C-terminal peptide (residues 150 to 177) ending with phenylalanine. These results suggest that the mature core protein (molecular mass of 19,306 Da) includes residues 2 to 177 and that its N terminus is blocked with an acetyl group.  相似文献   

8.
Xiong S  Ding Q  Zhao Z  Chen W  Wang G  Liu S 《Proteomics》2003,3(3):265-272
High detection sensitivity and resolution are two critical parameters for recording good peptide mass fingerprints (PMF) of low abundance proteins. This paper reports a mass spectrometry (MS) sample preparation technique that could improve sensitivity and resolution. By coating the MS steel target with a thin layer of pentadecafluorooctamido propyltrimethoxysilane, which was both polar and nonpolar solvent repellent, the transferred sample droplets on its surface were significantly smaller. As a result, the analyte of the peptide mixture became more concentrated and homogeneous, which helped to improve the sensitivity. The advantages of a modified MS target were documented by mass spectra improvement of attomole level standard peptides and silver-stained proteins from polyacrylamide gels. The mass signal of angiotensin II at 100 attomole was difficult to record on the conventional support, whereas it was easily detected on the modified one. The PMF of cytochrome C was also better recorded on the modified support, in terms of both signal-to-noise ratio and the number of detected peptides. When silver-stained proteins from two-dimensional electrophoresis gels were analyzed, in most cases more satisfactory peptide mass spectra were obtained from the modified support. Searching protein databases with more mass data from the improved PMFs, several unknown proteins were successfully identified.  相似文献   

9.
Salivary agglutinin is a high molecular mass component of human saliva that binds Streptococcus mutans, an oral bacterium implicated in dental caries. To study its protein sequence, we isolated the agglutinin from human parotid saliva. After trypsin digestion, a portion was analyzed by matrix-assisted laser/desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), which gave the molecular mass of 14 unique peptides. The remainder of the digest was subjected to high performance liquid chromatography, and the separated peptides were analyzed by MALDI-TOF/post-source decay; the spectra gave the sequences of five peptides. The molecular mass and peptide sequence information showed that salivary agglutinin peptides were identical to sequences in lung (lavage) gp-340, a member of the scavenger receptor cysteine-rich protein family. Immunoblotting with antibodies that specifically recognized either lung gp-340 or the agglutinin confirmed that the salivary agglutinin was gp-340. Immunoblotting with an antibody specific to the sialyl Le(x) carbohydrate epitope detected expression on the salivary but not the lung glycoprotein, possible evidence of different glycoforms. The salivary agglutinin also interacted with Helicobacter pylori, implicated in gastritis and peptic ulcer disease, Streptococcus agalactiae, implicated in neonatal meningitis, and several oral commensal streptococci. These results identify the salivary agglutinin as gp-340 and suggest it binds bacteria that are important determinants of either the oral ecology or systemic diseases.  相似文献   

10.
In order to identify new orcokinin and orcomyotropin-related peptides in crustaceans, molecular and immunocytochemical data were combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). In the crayfish Procambarus clarkii, four orcokinins and an orcomyotropin-related peptide are present on the precursor. Because these peptides are highly conserved, we assumed that other species have an identical number of peptides. To identify the peptides, immunocytochemistry was used to localize the regions of the stomatogastric nervous system in which orcokinins are predominantly present. One of the regions predominantly containing orcokinins was a previously undescribed olive-shaped neuropil region within the commissural ganglia of the lobsters Homarus americanus and Homarus gammarus. MALDI-TOF MS on these regions identified peptide masses that always occur together with the known orcokinins. Seven peptide ions occurred together in the peptide massspectra of the lobsters. Mass spectrometric fragmentation by MALDI-MS post-source decay (PSD) and electrospray ionization quadrupole time-of-flight mass spectrometry (ESI Q-TOF MS) collision-induced dissociation (CID) were used in the identification of six of these masses, either as orcokinins or as orcomyotropin-related peptides and revealed three hitherto unknown peptide variants, two of which are [His13]-orcokinin ([M+H]+ = 1540.8 Da) and an orcomyotropin-related peptide FDAFTTGFGHN ([M+H]+ = 1213.5 Da). The mass of the third previously unknown orcokinin variant corresponded to that of an identified orcokinin, but PSD fragmentation did not support the suggested amino acid sequence. CID analysis allowed partial de novo sequencing of this peptide. In the crab Cancer pagurus, five orcokinins and an orcomyotropin-related peptide were unambigously identified, including the previously unknown peptide variant [Ser9-Val13]-orcokinin ([M+H]+ = 1532.8 Da).  相似文献   

11.
This paper presents computational methods to analyze MALDI-TOF mass spectrometry data for quantitative comparison of peptides and glycans in serum. The methods are applied to identify candidate biomarkers in serum samples of 203 participants from Egypt; 73 hepatocellular carcinoma (HCC) cases, 52 patients with chronic liver disease (CLD) consisting of cirrhosis and fibrosis cases, and 78 population controls. Two complementary sample preparation methods were applied prior to generating mass spectra: (1) low molecular weight (LMW) enrichment of each serum sample was carried out for MALDI-TOF quantification of peptides, and (2) glycans were enzymatically released from proteins in each serum sample and permethylated for MALDI-TOF quantification of glycans. A peak selection algorithm was applied to identify the most useful peptide and glycan peaks for accurate detection of HCC cases from high-risk population of patients with CLD. In addition to global peaks selected by the whole population based approach, where identically labeled patients are treated as a single group, subgroup-specific peaks were identified by searching for peaks that are differentially abundant in a subgroup of patients only. The peak selection process was preceded by peak screening, where we eliminated peaks that have significant association with covariates such as age, gender, and viral infection based on the peptide and glycan spectra from population controls. The performance of the selected peptide and glycan peaks was evaluated in terms of their ability in detecting HCC cases from patients with CLD in a blinded validation set and through the cross-validation method. Finally, we investigated the possibility of using both peptides and glycans in a panel to enhance the diagnostic capability of these candidate markers. Further evaluation is needed to examine the potential clinical utility of the candidate peptide and glycan markers identified in this study.  相似文献   

12.
Single-cell MALDI: a new tool for direct peptide profiling   总被引:7,自引:0,他引:7  
Matrix-assisted laser desorption-ionization (MALDI) mass spectrometry (MS) is a rapid and sensitive analytical approach that is well suited for obtaining molecular weights of peptides and proteins from complex samples. MALDI-MS can profile the peptides and proteins from single-cell and small tissue samples without the need for extensive sample preparation, except for the cell isolation and matrix application. Strategies for peptide identification and characterization of post-translational modifications are presented. Furthermore, several recent enhancements in MALDI-MS technology, including in situ peptide sequencing as well as the direct spatial mapping of peptides in cells and tissues are discussed.  相似文献   

13.
An antibacterial peptide was isolated from a lepidopteran insect, Spodoptera litura. The molecular mass of this peptide was determined to be 4489.55 by matrix assisted laser desorption/ionization-time of flight mass (MALDI-TOF MS) spectrometry. The peptide consists of 42 amino acids and the sequence has 69-98% identity to those of moricin-related peptides, antibacterial peptides from lepidopetran insects. Thus, the peptide was designated S. litura (Sl) moricin. Sl moricin showed a broad antibacterial spectrum against Gram-positive and negative bacteria. Sl moricin gene was inducible by bacterial injection and expressed tissue-specifically in the fat body and hemocytes. Furthermore, the solution structure of Sl moricin was determined by two-dimensional (2D) 1H-nuclear magnetic resonance (NMR) spectroscopy and hybrid distance geometry-simulated annealing calculation. The tertiary structure revealed a long alpha-helix containing eight turns along nearly the full length of the peptide like that of moricin, confirming that Sl moricin is a new moricin-like antibacterial peptide. These results suggest that moricin is present not only in B. mori but also in other lepidopteran insects forming a gene family.  相似文献   

14.
Mass spectrometry and peptide-centric approaches are powerful techniques for the identification of differentially expressed proteins. Despite enormous improvements in MS technologies, sample preparation and efficient fractionation of target analytes are still major bottlenecks in MS-based protein analysis. The complexity of tryptically digested whole proteomes needs to be considerably reduced before low abundance proteins can be effectively analyzed using MS/MS. Sample preparation strategies that use peptide-specific antibodies are able to reduce the complexity of tryptic digests and lead to a substantial increase in throughput and sensitivity; however, the number of peptide-specific capture reagents is low, and consequently immunoaffinity-based approaches are only capable of detecting small sets of protein-derived peptides. In this proof-of-principle study, special anti-peptide antibodies were used to enrich peptides from a complex mixture. These antibodies recognize short amino acid sequences that are found directly at the termini of the peptides. The recognized epitopes consist of three or four amino acids only and include the terminally charged group of the peptide. Because of its limited length, antibodies recognizing the epitope will enrich not only one peptide but a whole class of peptides that share this terminal epitope. In this study, β-catenin-derived peptides were used to demonstrate that it is possible (i) to effectively generate antibodies that recognize short C-terminal peptide epitopes and (ii) to enrich and identify peptide classes from a complex mixture using these antibodies in an immunoaffinity MS approach. The expected β-catenin peptides and a set of 38 epitope-containing peptides were identified from trypsin-digested cell lysates. This might be a first step in the development of proteomics applications that are based on the use of peptide class-specific antibodies.  相似文献   

15.
Male copulation behavior in mollusks is controlled by an array of peptide messengers. In the present study, we have used a peptidomics approach employing liquid chromatography in conjunction with electrospray mass spectrometry to characterize peptides contained in the penial complex of the freshwater snail, Lymnaea stagnalis. In addition to the previously described peptides, we have identified a group of novel peptides that share the carboxyl termini of -FVRIamide. A cDNA cloning study revealed the organization of the precursor, which contains 20 peptide domains with the carboxyl termini of -F(X)RIamide which are flanked by many putative proteolytic sites including the KR and the less commonly occurring (G)K and (G)R sites. In addition, there are several monobasic R and dibasic RR and KK sites that may be used for processing. We then used MALDI-TOF/TOF-MS in a data-dependent mode, which selected all the molecular ion species with the predicted masses of the mature -F(X)RIamide peptides, and performed MS/MS analysis on these peptides. This approach allowed us to identify all the predicted -F(X)RIamide peptides. Immunocytochemistry showed the localization of -FVRIamide immunoreactive neurons in several central ganglia, and immunoreactive axons in the penial complex. Finally, application of synthetic -FVRIamide peptides to an in vitro posterior vas deferens preparation showed inhibitory effect on the spontaneous contraction/relaxation cycle of the vas deferens.  相似文献   

16.
The use of mass spectrometry (MS) for analysing low-molecular weight proteins and peptides from biological fluids has a great, yet not fully realized, potential for biomarker discovery. To prune MS-data as much as possible for non-relevant non-biological variation the development of standardized protocols for handling and processing the samples before MS and adjusting data after MS to compensate for method-induced variability are warranted. This calls for knowledge about how different variables contribute to MS-based proteome analyses. In addition, identification of the peptides involved in pre-analytical variation will be helpful in evaluating the clinical significance of predictive models derived from MS data. Using human sera, extraction by weak cation-exchange magnetic beads, and analysis by MALDI-TOF MS we here evaluated pre-analytical variation and identify peptides involved in this. The influences of humidity, temperature, and time for preparation of sera on spectral changes were evaluated. Also, the reproducibility of the methods and the effect of a baseline correction procedure were examined. Low temperatures, short handling times, and a baseline correction procedure minimize the contribution of artifacts to sample variability as observed by MS. The complement split product C3f and fragments thereof appear to be sensitive indicators of sample handling induced modifications. Other peptides that are indicative of such variability are fibrin and kininogen fragments. Using strict experimental guidelines as well as standardized sample collection procedures it is possible to obtain reproducible peak intensities and positions in serum mass profiling using magnetic bead-based fractionation and MALDI-TOF MS.  相似文献   

17.
The occurrence of neuropeptides in the retrocerebral complexes of adult male and females of the tobacco hawkmoth, Manduca sexta, was investigated using matrix-assisted laser desorption time of flight (MALDI-TOF) mass spectrometry (MS), post source decay (PSD) and collision-induced dissociation (CID) MS/MS. From fractions of methanol extracts of corpora cardiaca (CC)/corpora allata (CA), separated by reversed-phase high performance liquid chromatography (RP-HPLC), a total of 11 mass ions were assigned to known peptides from M. sexta. These peptides were adipokinetic hormone (AKH), FLRFamides I, II and III, crustacean cardioactive peptide (CCAP), cardioactive peptide 2b (CAP(2b)), three myoinhibitory peptides, corazonin, and M. sexta allatostatin (Manse-AS). A further six masses were in agreement with Y/FXFGLamide allatostatins identified from other Lepidoptera. The sequence identities of FLRFamide I and AKH were confirmed using post source decay analysis. Fragmentation by collision-induced dissociation MS/MS identified an extended AKH peptide. The apparent differences in the peptides present in male and female retrocerebral complexes are most likely quantitative rather than sex specific.  相似文献   

18.
Peptidome analysis has received increasing attention in recent years. Cancer diagnosis by serum peptidome has also been reported by peptides' profiling for discovery of peptide biomarkers. Tissue, which may have a higher biomarker concentration than blood, has not been investigated extensively by means of peptidome analysis. Here, a method for the peptidome analysis of mouse liver was developed by the combination of size exclusion chromatography (SEC) prefractionation with nano-liquid chromatography-tamdem mass spectrometry (nanoLC-MS/MS) analysis. The extracted peptides from mouse liver were separated according to their molecular weight using a size exclusion column. MALDI-TOF MS was used to characterize the molecular weight distribution of the peptides in fractions eluted from the SEC column. The low molecular weight (LMW) (MW < 3000 Da) peptides in the collected fractions were directly analyzed by LC-MS/MS which resulted in the identification of 1181 unique peptides (from 371 proteins). The high molecular weight (HMW) (MW > 3000 Da) peptides in the early two fractions from the SEC column were first digested with trypsin, and the resulted digests were then analyzed by LC-MS/MS, which led to the identification of 123 and 127 progenitor proteins of the HMW peptides in fractions 1 and 2, respectively. Analysis of the peptides' cleavage sites showed that the peptides are cleaved in regulation, which may reflect the protease activity and distribution in body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery.  相似文献   

19.
A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based kinase assay using a peptide substrate tagged with a biotinyl group has been developed. The peptide moiety was designed to serve as an efficient substrate for calcium/calmodulin-dependent protein kinase II, based on the in vivo phosphorylation site of phosrestin I, a Drosophila homolog of arrestin. In the assay, the quantitative relationship was determined from the ratio of the peak areas between the two peaks respectively representing the unphosphorylated and the phosphorylated substrate. Attempts to assay phosphorylated peptides directly from the reaction mixture, gave inaccurate results because of the high noise level caused by the presence of salts and detergents. In contrast, after purifying the substrate peptides with the biotin affinity tag using streptavidin-coated magnetic beads, peak areas accurately represented the ratio between the unphosphorylated and phosphorylated peptide. By changing the substrate peptide to a peptide sequence that serves as a kinase substrate, it is expected that an efficient non-radioactive protein kinase assay using MALDI-TOF MS can be developed for any type of protein kinase. We call this technique "Affinity-Tagged Phosphorylation Assay by MALDI-TOF MS (ATPA-MALDI)." ATPA-MALDI should serve as a quick and efficient non-radioactive protein kinase assay by MALDI-TOF MS.  相似文献   

20.
Garaguso I  Borlak J 《Proteomics》2008,8(13):2583-2595
The analytical performance of MALDI-MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI-MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5-dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI-MS and MS/MS with high quality spectra acquisition. The between-spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower-attomole range for peptides, and we improved the performance of MALDI-MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in-gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in-gel digests from lung tissue lysate proteins separated by 2-DE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号