首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Electrocardiograms by standard limb lead, augumented unipolar limb lead and AB (Apex-Base) lead were recorded from 24 unanesthetized adult cats from a SPF closed colony. The unanesthetized cats were held in the sternal position or in the right lateral recumbent position by means of a net. The mean electrical axes of P, QRS and T waves were calculated on the basis of values of I, II and III leads. The ECG patterns and mean electrical axes were compared between the sternal position and the right lateral recumbent position. The results are summarized as follows. The mean values of RR duration, P wave duration, QRS complex duration, T wave duration, PQ interval and QT interval were 0.432, 0.033, 0.027, 0.101, 0.076 and 0.183 seconds, respectively. The values of duration, interval and amplitude were not prominently influenced by the change in posture. The ECG shape had a definite configuration on each lead except that leads I and a VL showed unstable patterns. Notches and R' waves appeared in every lead in many cases. There was a positive linear correlation between RR and QT duration: r = 0.798 in the sternal position and r = 0.525 in the right lateral recumbent position. The angle of QRS mean electrical axis on the horizontal plane was 66.90 degrees +/- 26.05 (SD) in the sternal position and 41.84 degrees +/- 75.23 (SD) in the right lateral recumbent position. The P and T mean electrical axes showed small variations.  相似文献   

3.
正常家鸽的宽频带心电图时域值和功率谱   总被引:2,自引:0,他引:2  
Ai HB  Zhang XY  Zhu JP  Qiu J  Wang YH 《生理学报》2003,55(5):607-611
实验用南京新博公司生产的NHE-1000型宽频带心电信息检测分析仪,研究了正常家鸽宽频带心电图(WFB-ECG)的时域值和QRS波群的功率谱。主要结果如下:(1)Ⅱ、Ⅲ、aVF导联,QRS波群均为主波向下,形成rS或 rSr’型,无Q波,与人类相应导联的心电图波形相反;S波的升支均有一较大的切迹(无一例外),Ⅱ导联切迹幅度为 0.413±0.133mV,宽度为9.733±1.291ms;Ⅱ、Ⅲ、aVF导联T波直立,方向均与主波相反门(1例除外)。aVR导联,QRS波群主波向上,形成Rs型,T波倒置,与主波方向相反(无一例外),也与人类aVR导联的波形相反。(2)P波时程与P-R段之比值为0.8,而人的为1.0-1.6,小鼠的为0.4。(3)Ⅱ导联QRS波群的功率谱特点:以低频信号(低于80 HZ)为主,而高频频段的相对能量比小鼠的低,比人的高,其中高频频段100-1000 Hz的相对能量为(10.181±7.443)%,80-300HZ为(15.418±10.579)%。(4)QRS波群的额面心电轴为-118°±10°(-96°~-136°);(5)心电向量环的位置与人类的相反,位于-90°~-180°相限。这些现象的产生原因可能是由于家鸽心室 Purkinje纤维末梢延伸到心外膜下心肌,导致心外膜下心肌先除极化,心内膜下心肌后除极化而产生的。  相似文献   

4.
Wide frequency band ECG and vectorcardiogram in anesthetized pigeon and mouse were studied from the standpoint of comparison. The key results were as follows: in pigeon, the direction of the main QRS was inverted in leads II, III and aVF, and upright in lead aVR, which was contrary to that in mouse. The T wave was upright in leads II, III and aVF, but inverted in lead aVR in pigeon, which was the same as that in mouse. In pigeon, there was a large notch on the upstroke of the S wave in lead II without exception, but there was no such notch in the corresponding lead in mouse. The QRS vector loop in the frontal plane lay between -90 and -180 degrees in pigeon, while that of mouse lay between 0 and 90 degrees. The relative power of high frequency range (80-1000 Hz) of the QRS in lead II was approximately 15% in pigeon, but 55% in mouse. The direction of the main QRS was contrary in pigeon and mouse because the subepicardial muscles were depolarized before the subendocardial muscles in pigeon, but the latter were depolarized before the former in mouse. The direction of the T waves was the same in both pigeon and mouse because subepicardial muscles were all repolarized before subendocardial muscles.  相似文献   

5.
Since functional overload in pregnancy frequently induces the appearance of symptoms that could arouse suspicion of myocardiopathy, it is important to analyse and characterize all electrocardiographic modifications during a healthy subject's pregnancy. Variations of the mean electrical axis (A) of P, QRS and T waves were evaluated in 52 healthy volunteers, 17-37 years, during pregnancy. The A values were measured, in the frontal plane, at the end of both I and III quarter of pregnancy, using a method of scalar determination. The As in I and III quarters was compared with those observed in the post-partum (at 5th day) and statistical evaluations were performed (Student t-test for paired observations). In the I quarter the mean A was 40 +/- 3 degrees for P, 40 +/- 16 degrees for QRS and 32.5 +/- 9 degrees for T wave, whereas in the III quarter the mean A changed to 37 +/- 2 degrees for P, 34 +/- 18 degrees for QRS and 31 +/- 9 degrees for T. During pregnancy, all mean As significantly diverted to the left side, AP about 3 degrees, AQRS about 6 degrees and AT about 1.5 degrees. These results were also confirmed by analysis of A frequency distribution histograms. In the post-partum (5th day) the A resumed basal values (I quarter's values). These results show: i) the physiological range of AP, AQRS and AT, during pregnancy; ii) left deviation of all three As at the end of III quarter. It is possible to conclude that variation over this range, particularly for QRS, could give evidence of the onset of cardiopathy.  相似文献   

6.
1. ECGs were recorded using five bipolar leads from the body surface of porgy Pagrus major and tilapia Oreochromis niloticus in fresh or sea-water, or held on a dry towel. 2. The maximum QRS amplitude was detected in lead V in both species being 54 +/- 25 microV in porgy and 241 +/- 78 microV in tilapia, respectively, when the fish were held on the dry towel. 3. Clear ECG waves could not be obtained from porgy in sea-water because of the porgy's small cardiac potential and leakage of the potential. However, clear ECG waves could be obtained in sea-water from the body surface of tilapia, with the average QRS amplitude being 35 +/- 8 microV. 4. The mean electrical P and QRS axes in tilapia were directed toward almost the same direction (frontal downward), whereas both P and QRS axes in most carp were in opposite directions. In porgy, the relationship between the P and QRS axes could not be identified due to the smaller amplitude of the P wave.  相似文献   

7.
The electrocardiogram of Macaca fascicularis   总被引:1,自引:0,他引:1  
Electrocardiograms from 16 male cynomolgus monkeys (Macaca fascicularis) were studied. Standard and augmented limb leads (I, II, III, aVR, aVL, aVF) were obtained with the animals restrained in a sitting position. Normal electrocardiographic parameters were determined, including PR and QT intervals; P, QRS, and T wave axes; P and QRS wave widths. Voltages in all standard and augmented limb leads were lower than previously reported for similar size monkeys.  相似文献   

8.
The widely used industrial solvent ethylene glycol monomethyl ether (EGME) is teratogenic to rats and mice, inducing a variety of heart and major vessel abnormalities. In the present study, electrocardiography was used to evaluate heart function in day 20 rat (Sprague-Dawley) fetuses from mothers treated on gestation days 7-13 (sperm = day 1) with 0, 25, or 50 mg/kg EGME by gavage in 10 ml/kg water. The increased incidence of fetuses with cardiovascular malformations (primarily right ductus arteriosus and ventricular septal defect) and abnormal electrocardiograms (EKG) was dose dependent. The most prevalent EKG abnormality was a prolonged QRS wave. Mean QRS intervals were not significantly increased by EGME exposure, but there were significantly more litters in the 50-mg/kg EGME group that had one or more fetuses with QRS complexes of 40 msec or longer. The enhanced duration and the appearance of the aberrant QRS's suggested the presence of an intraventricular conduction delay in these fetuses. Heart rate and other EKG characteristics such as the P wave or P-R and Q-T intervals were not significantly affected by exposure to EGME. There did not appear to be an association between abnormal EKG's and fetal heart dysmorphology.  相似文献   

9.
After unilateral uterine artery ligation in midpregnancy twelve guinea-pig does were anesthetized at 63 days of gestation. The ST waveform of the fetal electrocardiogram and the short term heart rate variability were studied during normoxia and in response to acute hypoxia in growth retarded fetuses (n = 12, mean +/- SEM, 58.5 +/- 3.9 g) and their normal sized littermates (n = 12, 94.3 +/- 3.5 g). Hypoxia was induced by letting the doe breathe a low-oxygen gas mixture. After 10 min of hypoxia fetal blood was sampled by decapitation and blood gases, acid-base status and catecholamine concentrations were analyzed. The does responded to decrease in inspired oxygen concentration with changes in oxygen tension (13.8 +/- 0.8 to 4.3 +/- 0.2 kPa) and oxygen saturation (99.9 +/- 0.1% to 70.5 +/- 1.8%). Fetal blood gases and plasma catecholamine concentrations did not differ between the groups. In the growth retarded group standard bicarbonate was significantly lower compared to controls. The T/QRS ratio (the quotient between T wave height and QRS peak to peak amplitude) was normal and similar in both groups prior to the hypoxic period. In response to hypoxia T/QRS ratio increased in the normal sized group and T/QRS was correlated to carbon dioxide tension, oxygen saturation, pH, lactate, standard bicarbonate concentration, standard base excess and plasma noradrenaline concentration, respectively. The growth retarded fetuses presented a completely different pattern where 7 out of 12 fetuses showed a biphasic ST waveform during hypoxia with depression and downward sloping of the ST segment and negative T wave.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8+/-11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1+/-3.4 years). The duration of diabetes was 13.9+/-7.8 years. The parameters were registered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3+/-2.7 beats.min(-1)), shortening of both QRS (79.9+/-1.6 ms) and QT (349.0+/-5.9 ms) and increased QT dispersion (115+/-36 ms) were observed in DM 1 when compared with the controls (75.0+/-2.1 beats. min.(-1), QRS 89.9+/-2.7 ms, QT 374.0+/-4.4 ms, QTd 34.0+/-12.0 ms, p<0.01). The QTc was 415.2+/-4.1 ms in DM 1 and 401.4+/-6.6 ms in controls (NS). Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases.  相似文献   

11.
Selected serum enzymes, cholesterol, triglycerides, glucose, uric acid, protein, albumin, bilirubin, BUN, hematology, and electrocardiograms (EKG) were obtained from adult male cynomolgus (Macaca fascicularis) and adult male stumptailed (Macaca arctoides) macaques. Serum alkaline phosphatase, uric acid, albumin, bilirubin, mean corpuscular hemoglobin (MCH), mean corpuscular volume (MCV) and monocytes were significantly lower in the cynomogus monkeys. This relationship was reversed for serum levels of triglycerides, phosphorus, red blood cell counts and lymphocytes. EKG analysis revealed significantly increased PR interval and QRS wave duration in the cynomolgus species. However, there were no differences in heart rate. Right axis deviation was common in both species.  相似文献   

12.
Toxic lead exposure in the urban rock dove   总被引:1,自引:0,他引:1  
Thirteen adult urban rock doves (Columba livia), 12 captured alive and one found dead, were studied from the Baltimore zoo. The mean concentration of lead in the blood for the 12 live birds was 184.5 +/- 531.2 (range 10.5-1,870 micrograms/dl). Three of the 13 birds with high measured blood and tissue lead concentrations were found at necropsy with lead shot pellets in their gizzards. Correlations were not found between concentrations of lead in the blood and body weight or hematocrit. Conversely, high correlations were noted between concentrations of lead in the blood and measured liver and kidney concentrations (r = 0.946, P less than 0.01; r = 0.993, P less than 0.01, respectively). Numbers of intranuclear acid-fast inclusions per 10 consecutive fields (100x oil immersion lens) correlated well with measured kidney lead concentrations (r = 0.990, P less than 0.001).  相似文献   

13.
Electrocardiographic evidence for cocaine cardiotoxicity in cat   总被引:2,自引:0,他引:2  
Recent case studies suggest that cocaine overdose may produce life-threatening cardiac arrhythmias. We therefore investigated its effects on the electrocardiogram (leads II and V1) and arterial blood pressure in cats anesthetized with pentobarbital. Cocaine was administered by intravenous infusion over a 2-min interval at 1 mg/kg in 10 cats. In 5 out of 10 cats an additional infusion of 3 mg/kg cocaine was also administered after hemodynamic and electrocardiographic parameters had returned to control values (i.e., within 10 min). During and following infusion of 1 mg/kg cocaine, no significant change in heart rate or systolic or diastolic blood pressure were found, however the QRS duration increased by 38% (from 46 +/- 5 to 64 +/- 12 ms) (p less than 0.01). Evidence for bundle branch block and (or) premature ventricular beats was observed in 9 out of 10 cats after 1 mg/kg cocaine. Infusion of a further 3 mg/kg cocaine in five cats significantly lowered diastolic blood pressure (from 98 +/- 18 to 64 +/- 28 mmHg; 1 mmHg = 133.3 Pa) (p less than 0.01), and further prolonged QRS to 79 +/- 14 ms, a 75% increase from the mean control value (p less than 0.01). In addition, 1st and 2nd degree atrioventricular block, ventricular extrasystoles, and ectopic rhythms (AV junctional or idioventricular) were observed in four out of five cats given 3 mg/kg cocaine. Mean plasma concentrations of cocaine were 1.37 +/- 0.39 micrograms/mL (4.28 +/- 1.22 microM) (n = 5) at the end of a 1 mg/kg infusion and 2.93 +/- 0.43 micrograms/mL (9.16 +/- 1.34 microM) after a 3 mg/kg infusion (n = 3).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
A kinetic assay has been developed to measure the strength of natural T7 promoters. By determining the rate of appearance of initiation products in the presence of constant concentrations of T7 RNA polymerase, an incomplete mixture of ribonucleoside triphosphates, and increasing promoter concentrations, a maximum rate of product formation (Vmax) and a promoter concentration giving half of the maximal activity ([P]Vmax/2) can be determined for any cloned T7 promoter. On supercoiled plasmids, it was found that the [P]Vmax/2 measured for the six promoters phi 1.1B, phi 1.3, phi 3.8, phi 6.5, phi 10, and phi 13 ranged from 3.4 +/- 1.1 to 12.0 +/- 2.4 nM while the Vmax values showed no significant trends. On plasmids that had been linearized by cleavage at a single site with a restriction endonuclease, the cloned T7 promoters assayed fell into two broad classes that appear to be characterized by the T7 class II and III promoters. Generally, the class II promoters required higher promoter concentrations to produce half of the maximum rates of initiation ([P]Vmax/2 values) than the class III promoters. The [P]Vmax/2 values for the class II promoters ranged from 20 +/- 2.7 to 23 +/- 3.6 nM, while the [P]Vmax/2 values for the class III promoters phi 10 and phi 13 were 13 +/- 1.6 nM and 7.8 +/- 1.4 nM. The one exception is the class III promoter phi 6.5 whose [P] Vmax/2 (17 +/- 5 nM) falls between the [P]Vmax/2 values of the class II promoters and the strong class III promoters. The Vmax values measured on linear templates are variable, but it appears that phi 10 is more active than the other five promoters.  相似文献   

15.
The erythrocyte surface sialic acid levels of 200 apparently healthy indigenous Nigerian poultry species (pigeons, guinea fowls, ducks and chickens, n = 50 for each species) presented for slaughter at a poultry abattoir in Zaria, Nigeria was determined. Other parameters determined were packed cell volume (PCV) and plasma total protein (TP) concentration. The mean erythrocyte surface sialic acid concentration of pigeons, guinea fowls, ducks and chickens were 7.88 +/- 2.51, 14.6 +/- 2.51, 17.6 +/- 2.51 and 14.2 +/- 2.51 mg mg(-1) respectively. There was a statistically significant difference between the mean erythrocyte surface sialic acid concentration of all the species of poultry sampled (P < 0.05). The high erythrocyte surface sialic acid concentration in the indigenous Nigerian poultry species could be responsible for their resistance to infectious diseases, whose aetiologic agents produce neuraminidases. The mean PCV of the pigeons, guinea fowls, ducks and chickens were 46.22 +/- 6.91, 38.24 +/- 6.91, 36.50 +/- 6.91 and 36.46 +/- 6.91% respectively. The difference between the mean PCV values of pigeons on the one hand and guinea fowls, ducks and chickens on the other was statistically significant (P < 0.05). A negative correlation (r = -0.36, P < 0.05) between mean erythrocyte surface sialic acid concentrations and PCV was observed, i.e. the birds with the highest mean PCV values had the lowest levels of erythrocyte surface sialic acid. There was no correlation between TP concentration and either erythrocyte surface sialic acid concentration or PCV values. It is suggested, based on this study, that erythrocyte sialic acid types in these species should be determined, as the results may be vital in selective breeding.  相似文献   

16.
Trametes versicolor and Pleurotus sajur-caju mycelia immobilized in Ca-alginate beads were used for the removal of mercuric ions from aqueous solutions. The sorption of Hg(II) ions by alginate beads and both immobilized live and heat-killed fungal mycelia of T. versicolor and P. sajur-caju was studied in the concentration range of 0.150-3.00 mmol dm(-3). The biosorption of Hg(II) increased as the initial concentration of Hg(II) ions increased in the medium. Maximum biosorption capacities for plain alginate beads were 0.144+/-0.005 mmol Hg(II)/g; for immobilized live and heat-killed fungal mycelia of T. versicolor were 0.171+/-0.007 mmol Hg(II)/g and 0.383+/-0.012 mmol Hg(II)/g respectively; whereas for live and heat-killed P. sajur-caju, the values were 0.450+/-0.014 mmol Hg(II)/g and 0.660+/-0.019 mmol Hg(II)/g respectively. Biosorption equilibrium was established in about 1 h and the equilibrium adsorption was well described by Langmuir and Freundlich adsorption isotherms. Between 15 and 45 degrees C the biosorption capacity was not affected and maximum adsorption was observed between pH 4.0 and 6.0. The alginate-fungus beads could be regenerated using 10 mmol dm(-3) HCl solution, with up to 97% recovery. The biosorbents were reused in five biosorption-desorption cycles without a significant loss in biosorption capacity. Heat-killed T. versicolor and P. sajur-caju removed 73% and 81% of the Hg(II) ions, respectively, from synthetic wastewater samples.  相似文献   

17.

Background

Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS).

Methods

RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II.

Results

All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3.

Conclusion

These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.  相似文献   

18.
Atrial fibrillation (AF) is a frequent arrhythmia in patients undergoing hemodialysis (HD). P wave duration (PWdu) and P wave dispersion (PWdi) have been shown to be predictors of emerging AF in different clinical conditions. We sought to study the impact of HD on PWdu, PWdi, and P wave amplitude in a cohort of patients undergoing HD. Seventeen patients (8 men, 31+/-10 years) were studied. Echocardiography parameters, the sum of the amplitude of P waves in all 12 ECG leads (SP), mean PWdu, and PWdi, along with a host of other parameters (body weight, heart rate, electrolytes and hemoglobin/hematochrit) were measured 1/2h, before and after, HD. SP increased (11.8+/-3.9 vs 15.3+/-4.0 mm, p = 0.004), mean PWdu remained stable (82.7+/-11.1 vs 81.6+/-10.5 ms, p = 0.606), PWdi decreased (51.7+/-19.1 vs 41.7+/-19.1 ms, p = 0.03), and left atrial dimension decreased (37.96+/-3.90 vs 30.62+/-3.38 mm, p = 0.0001), after HD. The change in PWdi correlated with fluid removed by HD (r = -0.55, p = 0.022). Re-measurements of P-wave parameters in a random group of 11 of the 17 patients revealed augmented SP (p = 0.01), and stable mean PWdu (p = 0.36), and PWdi (p = 0.31), after HD. Fluid removed by HD leads to an increase in SP, a stable mean PWdu, and decrease (or stability on re-measurement in a subgroup of patients) in PWdi. Stability of PWdu may be due to the effects of augmentation of the P-wave amplitude and the reduction of the left atrial volume, cancelling each other. Variability of PWdi may stem from the occasional impossibility to measure PWdu (or measure it correctly) in minute P-waves in certain ECG leads, which in turn profoundly affects the PWdi.  相似文献   

19.
One hundred sixty-seven plasma samples of free-living birds of prey from Berlin and Brandenburg State (Germany) were tested for antibodies against avian adenovirus (FAV, group I) using agar gel precipitation test. Antibodies to FAV were detected in seven (4%) of 167 total samples. The positive samples originated only from common buzzards (Buteo buteo; seven [12%] of 59). This serologic survey provides evidence of natural exposure of free-living common buzzards from eastern Germany to adenoviruses.  相似文献   

20.
The electric heart activity can be localised from body surface mapping data with computer algorithms. At higher heart rates the T and P waves merge. Thus, the offset can not be subtracted in the TP segment. We investigated 28 healthy volunteers with signal averaged 31-lead magnetocardiography. The offset of the baseline was determined in the TP-segment and in the PR-segment, respectively. The electrical heart activity was localised in the initial 30 ms of the QRS complex (Q), at the QRS maximum (R), and at the T wave maximum (T). The volume currents were considered by using a boundary element model with the compartments lungs and torso. The 3D positions of the dipoles, the dipole orientations, and the dipole strengths were calculated using the data preprocessed with two different offset correction intervals. The offsets of the TP and PR segments significantly differed one from another. The average deviations of the dipole localisation were within a few centimetres (Q: 20 +/- 31 mm, R: 6 +/- 13 mm, T: 14 +/- 30 mm). However, in a small number of subjects (Q: n = 5, R: n = 2, T: n = 5) we observed a deviation of more than 30 mm. These deviations were not linearly correlated to the differences in the baseline offsets. High resolution recordings continuously detect heart activity in the PR segment. The correction of the baseline in the PR segment instead of the TP segment may introduce artefacts in the source localisation and therefore should be avoided.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号