首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
The objective of a long-term stability experiment is to confirm analyte stability in a given biological matrix, encompassing the duration of time from sample collection to sample analysis for a clinical or preclinical study. While long-term analyte stability has been identified as a key component of bioanalytical method validation, current regulatory guidance provides no specific recommendations regarding the design and analysis of such experiments. This paper reviews and evaluates various experimental designs, data analysis methods, and acceptance criteria for the assessment of long-term analyte stability. Statistical equivalence tests based on linear regression techniques are advocated. Both a nested errors and bivariate mixed model regression approach are suitable for application to long-term stability assessment, and control the risk of falsely concluding stability.  相似文献   

2.
Elevation of plasma homocysteine concentration is recognized as an independent predictor of cardiovascular disease risk. Therefore, quantification of homocysteine and related sulphur amino acids cysteine and methionine from plasma samples is routinely performed in clinical laboratories. Due to the highly hydrophilic character of these amino acids, previously reported LC-MS methods often suffered from very short chromatographic retention resulting in inadequate separation from matrix background and possible co-eluents. In the present method, aqueous normal phase (ANP) chromatography was introduced to improve chromatographic separation for liquid chromatography-electrospray ionization tandem mass spectrometry. Selective qualification of analytes and internal standards was achieved by qualifier ion monitoring. Using this enhanced selectivity, spurious co-eluents were identified and separated from the analyte signal by optimization of chromatographic conditions. Method validation proved high precision and accuracy (intra-assay reproducibility 1.2-4.3% CV, inter-assay reproducibility 3.4-6.1% CV, accuracy 91.3-105.9%). Total cycle time of 7 min and low costs per sample allow high-throughput application in clinical diagnostics and research trials.  相似文献   

3.
A method for the simultaneous analysis of asymmetric dimethylarginine, symmetric dimethylarginine, monomethylarginine and arginine in human plasma and urine, with short analysis time and isotopic internal standardisation for each analyte is described. The method requires neither sample derivatisation nor the need for chromatographic separation of analytes. The method described shows good precision and accuracy and is suited for both research purposes and implementation in the busy, routine clinical laboratory. In addition the synthesis and utilisation of isotopically labelled symmetric dimethylarginine and monomethylarginine is described for the first time, avoiding the use of surrogates such as homoarginine for internal standardisation.  相似文献   

4.
A novel skin tissue extraction method coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous pyrrole-2,3,5-tricarboxylic acid (PTCA), a eumelanin specific biomarker, in human skin punch biopsies. The analyte is extracted from the matrix (2 mm skin punch biopsies) using a simple oxidative degradation procedure. The extract supernatants are evaporated, reconstituted in mobile phase solvent, and injected into the LC/MS/MS system without further derivatization. The chromatographic separation is achieved on a reverse phase high performance liquid chromatography (HPLC) column. The accuracy and precision of the method was determined over the concentration range of 1-1000 ng/mL PTCA from human skin extracts in three validation batch runs. Inter-assay precision (%CV) and accuracy (%R.E.) of the quality control samples were 相似文献   

5.
BackgroundIncreased formation of reactive oxygen species may be caused by the ion release of the metal alloys used in prosthetic dental restorations due to the corrosion process. As products of lipid peroxidation, isoprostanes can be used as a marker for oxidative stress in the body. There are two significant advantages of using isoprostanes as an oxidative stress marker - presence in all fluids in the body and low reactivity. Saliva provides noninvasive, painless, and cost-effective sample collection and can be used as an alternative testing medium of blood and urine.MethodsThis study presents the development and validation of a sample LC-MS/MS method to quantify 8-isoprostaglandin F2-a in human saliva using salt-out assisted liquid-liquid extraction (SALLE).ResultsThe selected sample preparation procedure optimized chromatographic separation and mass detection provided high recovery and sensitivity of the analysis. The calibration curve was obtained in the predefined range 25-329 ng/L with R2 larger than 0.995. Normalized matrix varied between 89.7 % and 113.5%. The method showed sufficient accuracy and precision - accuracy in the range 89.7 %-113.9 %, and precision between 2.3% and 5.4%.ConclusionsThe proposed method is validated according to current EMA/FDA industrial guidance for bioanalysis and offers an appropriate level of sensitivity and sufficient accuracy and precision.  相似文献   

6.
Isotope ratio determination in boron analysis   总被引:1,自引:0,他引:1  
Traditionally, boron (B) isotope ratios have been determined using thermal ionization mass spectrometry (TIMS) and, to some extent, secondary ion mass spectrometry (SIMS). Both TIMS and SIMS use a high-resolution mass analyzer, but differ in analyte ionization methods. TIMS uses electrons from a hot filament, whereas SIMS employs an energetic primary ion beam of Ga+, Cs+, or O- for analyte ionization. TIMS can be used in negative or positive ion modes with high sensitivity and precision of B isotope ratio determination. However, isobaric interferences may be a problem, if the sample is not well purified and/or memory of the previous sample is not removed. Time-consuming sample preparation, analyte (B) purification, and sample determination processes limit the applications of TIMS for routine analyses. SIMS can determine B and its isotope ratio in intact solid samples without destroying them, but has poorer resolution and sensitivity than TIMS, and is difficult to standardize for biological samples. Development of plasma-source mass spectrometry (MS) enabled the determination of B concentration and isotope ratio without requiring sample purification. Commonly used plasma-source MS uses an Ar inductively coupled plasma (ICP) as an ionization device interfaced to a low-resolution quadrupole mass analyzer. The quadrupole ICP-MS is less precise than TIMS and SIMS, but is a popular method for B isotope ratio determination because of its speed and convenience. B determination by ICP-MS suffers no spectroscopic interferences. However, sample matrices, memory effects, and some instrument parameters may affect the accuracy and precision of B isotope ratio determination if adequate precautions are not taken. New generations of plasma-source MS instruments using high-resolution mass analyzers provide better sensitivity and precision than the currently used quadrupole ICP-MS. Because of the convenience and high sample throughput, the high-resolution ICP-MS is expected to be the method of choice for B isotope ratio determination. The current state of instrumental capabilities is adequate for B isotope determination. However, precision and accuracy are primarily limited by sample preparation, introduction, and analytical methodology, including 1. Analyte loss and isotope fractionation during sample preparation. 2. The precision of B isotope determination in small samples, especially those containing low concentrations. 3. Difficult matrices. 4. Memory effects. Sample preparation by alkali fusion allows rapid and complete decomposition of hard-to-digest samples, but high-salt environments of the fused materials require extensive sample purification for B ratio determination. The alternative wet-ashing sample decomposition with HF also results in B loss and isotopic fractionation owing to the high volatility of BF3. Open-vessel dry- or wet-ashing methods usually do not work well for animal samples, and are also prone to B loss and contamination. Closed-vessel microwave digestion overcomes these problems, but the digests of biological materials have high C contents, which cause spectral interference on 11B and affect 11B/10B ratios. Exchange separation/preconcentration of B using exchange (cation or anion exchange, B-specific resin, e.g., Amberlite IRA-743) tend to cause B isotope fractionation, and C eluting from these resin columns may interfere with B isotope ratio determination. Memory effects of B that occur during sample determination may cause serious errors in B isotope ratio determination, especially when samples varying in B concentrations and/or isotope composition are analyzed together. Although the utilization of high-resolution plasma-source MS will undoubtedly improve analytical precision, it is the sample preparation, sample introduction, and analytical methodology that represent the primary limitation to accurate and precise B isotope ratio determination.  相似文献   

7.
Solid-phase extraction, utilizing a 96-well plate format, was used to isolate an alpha-1a receptor antagonist and internal standard from human plasma. Following the isolation procedure, the analyte and internal standard were separated and detected using reversed-phase HPLC coupled with atmospheric pressure chemical ionization (APCI) mass spectrometry operated in the positive ion multiple reaction monitoring (MRM) mode. Based upon the peak area ratio (analyte: internal standard) the analyte was quantified over a concentration range of 0.02-2 ng/ml. Assay validation results including parameters such as precision and accuracy are presented. The validated method was subsequently used to support human pharmacokinetic studies.  相似文献   

8.
Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC–MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the ‘non-specific loss’ of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC–MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the ‘non-specific binding’ of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. β-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of β-cyclodextrin to untreated urine samples does not recover the ‘lost’ analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200–20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from ?3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid–liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at ≤?60 °C and for at least 3 months when stored at ≤?60 °C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples.  相似文献   

9.
A selective and sensitive method for analysis of perfluorooctanoic acid (PFOA) in human serum and plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. A simple, automated sample preparation procedure, involving extraction of the target analyte with acetonitrile on protein precipitation media in a 96-well plate format was developed, allowing efficient handling of large numbers of samples. The proposed method uses the calibration standards prepared in a surrogate matrix (rabbit serum or plasma) and (13)C-labeled PFOA as the internal standard to account for matrix effects, instrument drift, and extraction efficiency. Human serum and plasma could not be used for matrix matching of calibration standards as endogenous levels of PFOA observed in the control human serum and plasma significantly exceeded the targeted lower limit of quantitation (LLOQ) of the method. Precision and accuracy of the method were demonstrated by analysis of rabbit serum and plasma control samples fortified at 0.5, 5, and 40 ng/mL PFOA and human serum and plasma fortified at 1.0, 5.0, 40 ng/mL PFOA. The LLOQ of 0.5 ng/mL PFOA was experimentally demonstrated for rabbit and human serum and plasma. Within-day precision and accuracy, short-term stability, freeze-thaw stability, equivalence of response between PFOA and APFO (the ammonium salt of PFOA), and dilution of concentrated samples were also investigated. The results of the validation experiments comply with the precision and accuracy limits defined by the FDA guidance document: "Guidance for Industry, Bioanalytical Method Validation", May 2001.  相似文献   

10.
Laquinimod is an immunomodulator that is currently in clinical trials. For pharmacokinetic and toxicokinetic studies in animals and humans a sensitive and accurate bioanalytical method was required. In this paper a bioanalytical method for the determination of laquinimod by liquid chromatography is described. After a protein precipitation step the plasma sample was injected onto a coupled-column HPLC system. After further purification from macromolecules on a short restricted access material C(18) column the analyte was transferred to a reversed-phase C(18) analytical column and separated from interfering substances. The analyte was detected by UV detection. The method was validated with respect to linearity, selectivity, precision, accuracy, limit of quantitation, limit of detection, recovery and stability. The limit of quantitation was 0.75 micromol/L, the intermediate precision was 1.8-3.6% (C.V.) and the accuracy was 97.7-114.7%. In conclusion, the method was found to perform well and is suitable for use in pharmacokinetic and toxicokinetic studies.  相似文献   

11.
A high-performance liquid chromatography (LC-MS) method has been developed and validated for the determination of dexamethasone in dried blood spot (DBS) samples. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30μl blood spots on specimen collection cards. An 8mm disc was cut from the DBS sample and extracted using a combination of methanol: water (70:30, v/v) containing the internal standard, triamcinolone acetonide. Extracts were centrifuged and chromatographic separation was achieved using a Zorbax Eclipse Plus C18 column using gradient elution with a mobile phase of acetonitrile and water with formic acid at a flow rate of 0.2ml/min. LC-MS detection was conducted with single ion monitoring using target ions at m/z 393.1 for dexamethasone and 435.1 for the internal standard. The developed method was linear within the tested calibration range of 15-800ng/ml. The overall extraction recovery of dexamethasone from DBS samples was 99.3% (94.3-105.7%). The accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all concentrations. Factors with potential to affect drug quantification measurements such as blood haematocrit, the volume of blood applied onto the collection card and spotting device were investigated. Although a haematocrit related effect was apparent, the assay accuracy and precision values remained within the 15% variability limit with fluctuations in haematocrit of ±5%. Variations in the volume of blood spotted did not appear to affect the performance of the developed assay. Similar observations were made regarding the spotting device used. The methodology has been applied to determine levels of dexamethasone in DBS samples collected from premature neonates. The measured concentrations were successfully evaluated using a simple 1-compartment pharmacokinetic model. Requiring only a microvolume (30μl) blood sample for analysis, the developed assay is particularly suited to pharmacokinetic studies involving paediatric populations.  相似文献   

12.
The metabolism of endogenous estrogens is complicated and certain metabolic patterns may reflect an individual risk of estrogen-dependent diseases such as breast cancer. Since the 1960s we have been constantly involved in developing estrogen profiling methods, in the beginning using gas chromatography and later gas chromatography–mass spectrometry (GC–MS) in the selected ion monitoring mode (SIM) and finally utilizing isotope dilution (ID–GC–MS–SIM). The addition of the dietary phytoestrogens to the profile rendered the method even more complicated. The present work presents the final estrogen profile method for 15 endogenous estrogens, four lignans, seven isoflavonoids and coumestrol in one small urine sample (1/150th of a 24 h human urine sample, minimum 2.5–5 ml) with complete validation including investigations as to the precision, sensitivity, accuracy and specificity. The method does not include the minimal amounts of unconjugated estrogens in urine. It may also be used for animal (e.g. rat and mouse) urine using a minimum of 2 ml of usually pooled sample. Despite its complexity it was found to fulfill the reliability criteria, resulting in highly specific and accurate results.  相似文献   

13.
In order to study the effect of a diet on metabolites found in body fluids such as plasma, we have developed and validated a UPLC/MS method. While methods using NMR have been well established to analyse different biological tissues, recent studies have described robust untargeted UPLC-MS methods for plasma analysis. One major concern when profiling plasma is the presence of an important quantity of proteins which have to be precipitated without any loss of metabolites prior to LC/MS analysis. The utilization of untargeted approaches in nutritional metabolomics still suffers from the lack of identification of specific biomarkers. We therefore suggest an alternative method still using a global approach but focusing at the same time on metabolites previously described in human plasma in order to detect biomarkers of metabolic dysregulations. Thus, to fulfil our objectives, analytical parameters were tested (i) the anticoagulant type for sample collection, (ii) the protein precipitation method and (iii) UPLC/MS analytical conditions. Three protein precipitation methods and two anticoagulants were tested and compared. The method utilizing blood collection on heparin and methanol precipitation was chosen for giving the most reproducible results while keeping the complexity of the sample. Finally, a validation was proposed to evaluate the stability of this analytical method applied to a large batch of samples for nutritional metabolomic studies.  相似文献   

14.
Correct test selection: a test must have the potential to alter patient management and have the specificity and sensitivity appropriate to the pretest probability of disease. Correct dynamic test procedure: dynamic tests may assist diagnosis and protocols must be readily available. Correct patient preparation: fasting, or other patient preparation, may reduce variability. Clear communication, to both patients and staff, of any such requirements is essential. Correct sample collection: the tube type (for blood) or container (for urine) must be appropriate for the analyte; there must be sufficient volume, avoidance of venous stasis, contaminants and haemolysis; and adequate labelling. Correct sample handling: the time and temperature before and after separation, and the centrifugation and separation procedures, must be suitable for the analyte. Accept/reject criteria must be defined. Methods require thorough evaluation of patient-related pre-analytical factors, and quantification of the effects of time, temperature, haemolysis, anticoagulant type and minimum allowable volume on sample suitability.  相似文献   

15.
Classification methods used in microarray studies for gene expression are diverse in the way they deal with the underlying complexity of the data, as well as in the technique used to build the classification model. The MAQC II study on cancer classification problems has found that performance was affected by factors such as the classification algorithm, cross validation method, number of genes, and gene selection method. In this paper, we study the hypothesis that the disease under study significantly determines which method is optimal, and that additionally sample size, class imbalance, type of medical question (diagnostic, prognostic or treatment response), and microarray platform are potentially influential. A systematic literature review was used to extract the information from 48 published articles on non-cancer microarray classification studies. The impact of the various factors on the reported classification accuracy was analyzed through random-intercept logistic regression. The type of medical question and method of cross validation dominated the explained variation in accuracy among studies, followed by disease category and microarray platform. In total, 42% of the between study variation was explained by all the study specific and problem specific factors that we studied together.  相似文献   

16.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

17.
Cross signal contributions between an analyte and its internal standard (IS) are very common due to impurities in reference standards and/or isotopic interferences. Despite the general awareness of this issue, how exactly they affect quantitation in LC-MS based bioanalysis has not been systematically evaluated. In this research, such evaluations were performed first by simulations and then by experiments using a typical bioanalytical method for tiagabine over the concentration range of 1-1000 ng/mL in human EDTA K(3) plasma. The results demonstrate that when an analyte contributes to IS signal, linearity and accuracy can be affected with low IS concentration. Thus, minimum IS concentrations have been obtained for different combinations of concentration range, percentage of cross contribution, and weighting factor. Moreover, while impurity in analyte reference standard is a factor in cross signal contribution, significant systematic errors could exist in the results of unknown samples even though the results of calibration standards and quality controls are acceptable. How these systematic errors would affect stability evaluation, method transfer, and cross validation has also been discussed and measures to reduce their impact are proposed. On the other hand, the signal contribution from an IS to the analyte causes shifting of a calibration curve, i.e. increase of intercept, and theoretically, the accuracy is not affected. The simulation results are well supported by experimental results. For example, good inter-run (between-run) accuracy (bias: -2.70 to 5.35%) and precision (CV: 2.07-10.50%) were obtained when runs were extracted with an IS solution containing 1-fold of the lower limit of quantitation.  相似文献   

18.
A UPLC-MS/MS assay was developed and validated for simultaneous quantification of acetylcholine (ACh), histamine (HA), tele-methylhistamine (t-mHA), and tele-methylimidazolacetic acid (t-MIAA) in rat cerebrospinal fluid (CSF). The biological stability of ACh in rat CSF was investigated. Following fit-for-purpose validation, the method was applied to monitor the drug-induced changes in ACh, HA, t-mHA, and t-MIAA in rat CSF following administration of donepezil or prucalopride. The quantitative method utilizes hydrophilic interaction chromatography (HILIC) Core-Shell HPLC column technology and a UPLC system to achieve separation with detection by positive ESI LC-MS/MS. This UPLC-MS/MS method does not require extraction or derivatization, utilizes a stable isotopically labeled internal standard (IS) for each analyte, and allows for rapid throughput with a 4 min run time. Without an acetylcholinesterase (AChE) inhibitor present, ACh was found to have 1.9±0.4 min in vitro half life in rat CSF. Stability studies and processing modification, including the use of AChE inhibitor eserine, extended this half life to more than 60 min. The UPLC-MS/MS method, including stabilization procedure, was validated over a linear concentration range of 0.025-5 ng/mL for ACh and 0.05-10 ng/mL for HA, t-mHA, and t-MIAA. The intra-run precision and accuracy for all analytes were 1.9-12.3% CV and -10.2 to 9.4% RE, respectively, while inter-run precision and accuracy were 4.0-16.0% CV and -5.3 to 13.4% RE, respectively. By using this developed and validated method, donepezil caused increases in ACh levels at 0.5, 1, 2, and 4h post dose as compared to the corresponding vehicle group, while prucalopride produced approximately 1.6- and 3.1-fold increases in the concentrations of ACh and t-mHA at 1h post dose, respectively, compared to the vehicle control. Overall, this methodology enables investigations into the use of CSF ACh and HA as biomarkers in the study of these neurotransmitter systems and related drug discovery efforts.  相似文献   

19.
Bestatin is a low molecular weight aminopeptidase inhibitor originally isolated from culture filtrates of Streptomyces olivoreticuli. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of bestatin in rat plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 50 microL plasma samples by solid phase extraction (SPE). Reverse-phase HPLC separation was accomplished on a Lichrospher C18 column (4.6 mm x 50 mm, 5 microm) with a mobile phase composed of methanol-water-formic acid (70:30:0.5, v/v/v) at a flow rate of 0.8 mL/min. The method had a chromatographic total run time of 3 min. A Varian 1200L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 309.2-->120.0 (bestatin) and 313.4-->138.0 (granisetron) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 5 ng/mL, with good linearity (r2 >or= 0.999) over the linear range of 5-2000 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of bestatin in rats.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号