首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
This paper describes a sensor for label-free, fully electrical detection of DNA hybridization based on capacitive changes in the electrode-electrolyte interface. The sensor measures capacitive changes in real time according to a charging-discharging principle that is limited by the hysteresis window. In addition, a novel autonomous searching technique, which exclusively monitors desorption-free hybridized electrodes among electrode arrays, enhances the performance of the sensor compared with conventional capacitive measurement. The sensor system achieves a detection range of 80 dB. The integrated circuit sensor is fabricated with a 0.35 μm CMOS process. The proposed sensor offers rapid, robust and inexpensive measurement of capacitance with highly integrated detection circuitry. It also facilitates quantitative evaluations of molecular densities on a chip with distinctive impedance variations by monitoring desorption-free hybridized electrodes. Our electrical biosensor has great potential for use with bio analytical tools and point-of-care diagnosis.  相似文献   

2.
The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinylferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method for the immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer, PVF, and the gold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential, the thickness of the polymeric film, the amount of the immobilized enzyme, pH, the amount of the deposited Au, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated.  相似文献   

3.
Construction, electrochemically biosensing and discrimination of recombinant pEThIL-2 plasmid, with 5839 bp size, on the basis of interleukine-2 (IL-2) DNA insert are described. Plasmid pEThIL-2 was constructed by PCR amplification of IL-2 encoding DNA and subcloning into pET21a(+) vector using BamHI and SacI sites. The recombinant pEThIL-2 plasmid was detected with a label-free DNA hybridization biosensor using a non-inosine substituted probe. The proposed sensor was made up by immobilization of a 20-mer antisense single strand oligonucleotide (chIL-2) related to the human interleukine-2 gene on the pencil graphite electrode (PGE) as a probe and then the sensing of recombinant pEThIL-2 plasmid was conducted by anodic differential pulse voltammetry (ADPV) based on guanine oxidation signal. Selectivity of the detection was assessed with pET21a(+) non-complementary plasmid, with 5443 bp size, lacking IL-2 encoding DNA. Different factors such as electrode activation conditions and washing strategy were tested in order to eliminate the nonspecific adsorption of pET21a(+). We have found that the PGE activation for 300 s produces a condition in which desorption of nonspecifically adsorbed plasmids from the electrode surface can be achieved by 300 s washing of the electrode in 20 mM Tris–HCl buffer solution (pH 7.0) containing 20 mM NaCl. Diagnostic performance of the biosensor is described and the detection limit is found to be 10.31 pg/μL.  相似文献   

4.
An electrochemical biosensor is described consisting of a thin-layer gold film electrode prepared by cathodic sputtering using a poly(vinyl chloride) sheet as substrate, with voltammetric behaviour comparable to that of conventional polycrystalline gold electrodes, coated with the hydrolysed copolymer hydroxyethyl methacrylate-co-methyl methacrylate onto which glucose oxidase was immobilized. The mechanical properties of the plastic foil substrate permit easy construction of circular-shaped electrodes which were employed as working electrodes for batch injection analysis. The electrochemical biosensor fabrication is inexpensive and can be used as disposable enzyme sensor for the detection of hydrogen peroxide. The biosensor was tested for the determination of glucose in serum and a good correlation was obtained with the measurement using the electrochemical and the spectrophotometric methods.  相似文献   

5.
Ectopic pregnancy (EP) and normal intrauterine pregnancy (IUP) serum proteomes were quantitatively compared to systematically identify candidate biomarkers. A 3-D biomarker discovery strategy consisting of abundant protein immunodepletion, SDS gels, LC-MS/MS, and label-free quantitation of MS signal intensities identified 70 candidate biomarkers with differences between groups greater than 2.5-fold. Further statistical analyses of peptide quantities were used to select the most promising 12 biomarkers for further study, which included known EP biomarkers, novel EP biomarkers (ADAM12 and ISM2), and five specific isoforms of the pregnancy specific beta-1-glycoprotein family. Technical replicates showed good reproducibility and protein intensities from the label-free discovery analysis compared favorably with reported abundance levels of several known reference serum proteins over at least 3 orders of magnitude. Similarly, relative abundances of candidate biomarkers from the label-free discovery analysis were consistent with relative abundances from pilot validation assays performed for five of the 12 most promising biomarkers using label-free multiple reaction monitoring of both the patient serum pools used for discovery and the individual samples that constituted these pools. These results demonstrate robust, reproducible, in-depth 3-D serum proteome discovery, and subsequent pilot-scale validation studies can be achieved readily using label-free quantitation strategies.  相似文献   

6.
Cortisol is a member of the glucocorticoid hormone family and a key metabolic regulator. Increased intracellular cortisol levels have been implicated in type 2 diabetes, obesity, and metabolic syndrome. Cortisol is an important bio-marker of stress and its detection is also important in sports medicine. However, rapid methods for sensitive detection of cortisol are limited. Functionalized gold nanowires were used to enhance the sensitivity and selectivity of cortisol detection. Gold nanowires are used to improve the electron transfer between the electrodes. Moreover, the large surface to volume ratio, small diffusion time and high electrical conductivity and their aligned nature will enhance the sensitivity and detection limit of the biosensor several fold. The biosensor was fabricated using, aligned gold (Au) nanowires to behave as the working electrode, platinum deposited on a silicon chip to function as the counter electrode, and silver/silver chloride as reference electrode. The gold nanowires were coupled with cortisol antibodies using covalent linkage chemistry and a fixed amount of 3alpha-hydroxysteroid dehydrogenase was introduced into the reaction cell during each measurement to convert (reduce) ketosteroid into hydroxyl steroid. Furthermore, the micro-fluidic, micro-fluid part of the sensor was fabricated using micro-electro-mechanical system (MEMS) technology to have better control on liquid flow over Au nanowires to minimize the signal to noise ratio. The biosensor was characterized using SEM, AFM and FTIR technique. The response curve of the biosensor was found to be linear in the range of 10-80 microM of cortisol. Moreover, the presence of hydrocortisone is sensitively detected in the range of 5-30 microM. It is concluded that the functionalized gold nanowires with micro-fluidic device using enzyme fragment complementation technology can provide an easy and sensitive assay for cortisol detection in serum and other biological fluids.  相似文献   

7.
The design and development of a screen printed carbon electrode (SPCE) on a polyvinyl chloride substrate as a disposable sensor is described. Six configurations were designed on silk screen frames. The SPCEs were printed with four inks: silver ink as the conducting track, carbon ink as the working and counter electrodes, silver/silver chloride ink as the reference electrode and insulating ink as the insulator layer. Selection of the best configuration was done by comparing slopes from the calibration plots generated by the cyclic voltammograms at 10, 20 and 30 mM K(3)Fe(CN)(6) for each configuration. The electrodes with similar configurations gave similar slopes. The 5th configuration was the best electrode that gave the highest slope. Modifying the best SPCE configuration for use as a biosensor, horseradish peroxidase (HRP) was selected as a biomaterial bound with gold nanoparticles (AuNP) in the matrix of chitosan (HRP/AuNP/CHIT). Biosensors of HRP/SPCE, HRP/CHIT/SPCE and HRP/AuNP/CHIT/SPCE were used in the amperometric detection of H(2)O(2) in a solution of 0.1M citrate buffer, pH 6.5, by applying a potential of -0.4V at the working electrode. All the biosensors showed an immediate response to H(2)O(2). The effect of HRP/AuNP incorporated with CHIT (HRP/AuNP/CHIT/SPCE) yielded the highest performance. The amperometric response of HRP/AuNP/CHIT/SPCE retained over 95% of the initial current of the 1st day up to 30 days of storage at 4 degrees C. The biosensor showed a linear range of 0.01-11.3mM H(2)O(2), with a detection limit of 0.65 microM H(2)O(2) (S/N=3). The low detection limit, long storage life and wide linear range of this biosensor make it advantageous in many applications, including bioreactors and biosensors.  相似文献   

8.
Use of the silver electrode as a sensor for the monitoring of zinc in cell growth medium is described. Zinc at silver electrodes provides specific voltammetric signal, which is affected by solution components. Signals of zinc ions in phosphate buffer solutions with and without cell growth medium were compared. Common DMEM cell culture medium was used for the cultivation of a cell line of v-myb-transformed chicken monoblasts and its variants expressing v-jun and c-jun in a zinc-dependent manner. Electrochemical results showed zinc concentrations in the medium coincide very well with the jun expression. With respect to the low toxicity of silver for eukaryotic cells, silver electrodes represent promising tools for the determination of zinc concentrations in vivo without the potential risk of a cell culture damage.  相似文献   

9.
For the purpose of developing a direct label-free electrochemical detection system, we have systematically investigated the electrochemical signatures of each step in the preparation procedure, from a bare gold electrode to the hybridization of label-free complementary DNA, for the streptavidin-modified electrode. For the purpose of this investigation, we obtained the following pertinent data; cyclic voltammogram measurements, electrochemical impedance spectra and square wave voltammogram measurements, in Fe(CN)6 3−/Fe(CN)6 4− solution (which was utilized as the electron transfer redox mediator). The oligonucleotide molecules on the streptavidin-modified electrodes exhibited intrinsic redox activity in the ferrocyanide-mediated electrochemical measurements. Furthermore, the investigation of electrochemical electron transfer, according to the sequence of oligonucleotide molecules, was also undertaken. This work demonstrates that direct label-free oligonucleotide electrical recognition, based on biofunctional streptavidin-modified gold electrodes, could lead to the development of a new biosensor protocol for the expansion of rapid, cost-effective detection systems.  相似文献   

10.
The determination of bile acid concentration in urine is useful for the screening and diagnosis of various hepatobiliary diseases. Currently, there is no concise method to determine bile acid concentration in urine. This study describes a bile acid biosensor fabricated by electrochemical technique for urinalysis. The micro-planar electrodes employed for the study consisted of a working electrode (platinum), a counter electrode (platinum) and a reference electrode (silver/silver chloride (Ag/AgCl)). The sensor chip was coated with Nafion using a spin-coater in order to both eliminate many interference species in urine and achieve long-term stability of the reference electrode. Nafion coating allowed the sensor chip to prevent the electrode reaction from interference species in urine, because it is charged negative strongly (Nafion contains sulfonic acid group). Three enzymes (bile acid sulfate sulfatase: BSS, beta-hydroxysteroid dehydrogenase: beta-HSD, and NADH oxidase: NHO) were immobilized by glutaraldehyde (GA: cross-linker) onto the sensor chip, because the immobilization of enzymes by GA is simple and commonly carried out. The sensor chip was able to detect bile acid in buffer solution. The optimum enzyme ratio immobilized onto the sensor chip was BSS:beta-HSD:NHO=4:4:20 U/1 chip. There was a relationship between the concentration of bile acid and the response current value. The dynamic range of the sensor chip was 2-100 microM for bile acid. Additionally, bile acid in the urine specimen could be detected using this bile acid biosensor. We present a simple and rapid bile acid biosensor with high sensitivity and high reproducibility.  相似文献   

11.
This paper presents a novel hormone‐based impedimetric biosensor to determine parathyroid hormone (PTH) level in serum for diagnosis and monitoring treatment of hyperparathyroidism, hypoparathyroidism and thyroid cancer. The interaction between PTH and the biosensor was investigated by an electrochemical method. The biosensor was based on the gold electrode modified by 12‐mercapto dodecanoic (12MDDA). Antiparathyroid hormone (anti‐PTH) was covalently immobilized on to poly amidoamine dendrimer (PAMAM) which was bound to a 1‐ethyl‐3‐(3‐dimethylaminopropyl)‐carbodiimide/N‐hydroxysuccinimide (EDC/NHS) couple, self‐assembled monolayer structure from one of the other NH2 sites. The immobilization of anti‐PTH was monitored by electrochemical impedance spectroscopy, cyclic voltammetry and scanning electron microscope techniques. After the optimization studies of immobilization materials such as 12MDDA, EDC–NHS, PAMAM, and glutaraldehyde, the performance of the biosensor was investigated in terms of linearity, sensitivity, repeatability, and reproducibility. PTH was detected within a linear range of 10–60 fg/mL. Finally the described biosensor was used to monitor PTH levels in artificial serum samples. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:815–822, 2015  相似文献   

12.
This paper reports a label-free biosensor for the detection of DNA hybridization. The proposed biosensor measures the surface potential on oligonucleotide modified electrodes using a direct charge accumulation method. The sensor directly and repeatedly measures the charges induced in the working electrode, which correspond to intrinsic negative charges in immobilized molecules. The sensor achieves an improved signal-to-noise ratio (SNR), through the oversampling effect of accumulation for charges and the differential architecture. The sensor also shows stable, robust, and reproducible measurement independent of slight changes in the reference voltage, unlike previous ion-sensitive field effect transistors (ISFETs), providing the benefits of choosing a wide variety of reference electrode materials. The proposed device is integrated with working electrodes, a reference electrode and readout circuits into one package via a 0.35 μm complementary metal-oxide-semiconductor (CMOS) process. The sensor achieves a detectable range of 88.3 dB and a detection limit of 36 μV for surface potential. It is demonstrated that the sensor successfully achieves specific detection of oligonucleotide sequences derived from the H5N1 avian influenza virus. The experiments show a limit of detection of 100 pM and include a single-base mismatch test in 18-mer oligonucleotides.  相似文献   

13.
Using silver nanoparticle to enhance current response of biosensor   总被引:6,自引:0,他引:6  
In this paper, we present a simple procedure to increase the sensitivity of a glucose biosensor. The feasibility of an amperometric glucose biosensor based on immobilization of glucose oxidase (GOx) in silver (Ag) sol was investigated for the first time. GOx was simply mixed with Ag nanoparticles and cross-linked with a polyvinyl butyral (PVB) medium by glutaraldehyde. Then a platinum electrode was coated with the mixed solution. The effects of the amount of the Ag particles used, with respect to the current response for enzyme electrodes, were studied. A set of experimental results indicate that the current response for the enzyme electrode containing hydrophobic Ag sol increased from 0.531 to 31.17 microA in the solution of 10 mmol/L beta-D glucose. The time reaching the steady-state current response reduced from 60 to 20s, three times less than those without Ag particles involved.  相似文献   

14.
An amperometric biosensor for hypoxanthine was constructed by forming a layer of crosslinked xanthine oxidase on a platinum electrode, followed by electropolymerization of a submonolayer film of resorcinol and para-diaminobenzene. The fabricated electrodes were evaluated for speed of response, sensitivity, and reusability. Optimal performance was obtained with enzyme-based electrodes sparsely covered with film which was formed by electropolymerization in less than 6 min. The resulting electrodes exhibited linear response to hypoxanthine in the. range 5-300 muM with a response time of 2 min. Application of the biosensor in monitoring hypoxanthine content of fish extracts yielded results which agreed well with spectrophotometric assays using soluble xanthine oxidase. The biosensor was stable for 60 days when stored at 4 degrees C in phosphate buffer and it could be used continuously for 6 h with over 50 assays.  相似文献   

15.
16.
Impedance spectroscopy (IS) is a powerful technique for analysis of the complex electrical impedance of a large variety of biological systems, because it is sensitive both to surface phenomena and to changes of bulk properties. A simple and convenient method of analysis of cell properties by IS is described. An interdigitated electrodes configuration was used for the measurements; human epithelial cells were grown on the device to investigate the complex dielectric response as a function of frequency, in order to test the suitability of the device for use as a label-free biosensor. To test the ability of the device to detect channels in the cell membrane, the effect of drugs known to affect membrane integrity was also investigated. The frequency response of the admittance (i.e. the reciprocal of the impedance) can be well fitted by a model based on very simple assumptions about the cells coating the device surface and the current flow; from the calculations, membrane-specific capacitance and information about cell adhesion can be inferred. These preliminary efforts have shown that our configuration could lead to a label-free non-invasive technique for biosensing and cellular behavior monitoring which might prove useful in investigation of the basic properties of cells and the effect of drugs by estimation of some fundamental properties and modification of the electrical characteristics of the device.  相似文献   

17.
A novel hepatitis B virus (HBV) DNA biosensor was developed by immobilizing covalently single-stranded HBV DNA fragments to a gold electrode surface via carboxylate ester to link the 3(')-hydroxy end of the DNA with the carboxyl of the thioglycolic acid (TGA) monolayer. A short-stranded HBV DNA fragment (181bp) of known sequence was obtained and amplified by PCR. The surface hybridization of the immobilized single-stranded HBV DNA fragment with its complementary DNA fragment was evidenced by electrochemical methods using [Os(bpy)(2)Cl(2)](+) as a novel electroactive indicator. The formation of double-stranded HBV DNA on the gold electrode resulted in a great increase in the peak currents of [Os(bpy)(2)Cl(2)](+) in comparison with those obtained at a bare or single-stranded HBV DNA-modified electrode. The mismatching experiment indicated that the surface hybridization was specific. The difference between the responses of [Os(bpy)(2)Cl(2)](+) at single-stranded and double-stranded DNA/TGA gold electrodes suggested that the label-free hybridization biosensor could be conveniently used to monitor DNA hybridization with a high sensitivity. X-ray photoelectron spectrometry technique has been employed to characterize the immobilization of single-stranded HBV DNA on a gold surface.  相似文献   

18.
Li G  Liao JM  Hu GQ  Ma NZ  Wu PJ 《Biosensors & bioelectronics》2005,20(10):2140-2144
A carbon nanotube modified biosensor for monitoring total cholesterol in blood was studied. This sensor consists of a carbon working electrode and a reference electrode screen-printed on a polycarbonate substrate. Cholesterol esterase, cholesterol oxidase, peroxidase and potassium ferrocyanide were immobilized on the screen-printed carbon electrodes. Multi-walled carbon nanotubes (MWCN) were added to prompt electron transfer. Experimental results show that the carbon nanotube modified biosensor offers a reliable calibration profile and stable electrochemical properties.  相似文献   

19.
Among the various label-free methods for monitoring biomolecular interactions, capacitive sensors stand out due to their simple instrumentation and compatibility with multiplex formats. However, electrode polarization due to ion gradient formation and noise from solution conductance limited early dielectric spectroscopic measurements to high frequencies only, which in turn limited their sensitivity to biomolecular interactions, as the applied excitation signals were too fast for the charged macromolecules to respond. To minimize electrode polarization effects, capacitive sensors with 20 nm electrode separation were fabricated using silicon dioxide sacrificial layer techniques. The nanoscale separation of the capacitive electrodes in the sensor results in an enhanced overlapping of electrical double layers, and apparently a more ordered “ice-like” water structure. Such effects in turn reduce low frequency contributions from bulk sample resistance and from electrode polarization, and thus markedly enhance sensitivity toward biomolecular interactions. Using these nanogap capacitive sensors, highly sensitive, label-free aptamer-based detection of protein molecules is achieved.  相似文献   

20.
A novel detection system for the determination of glucose in the presence of clinically important interferents, based on the use of dual sensors and flow-injection analysis (FIA), is described. The normalisation methodology involves measurement of the interference signal at a reference sensor; this signal can then be subtracted from the glucose sensor signal (post-run) to give a corrected measurement of the glucose concentration. The detection system consists of a thin layer cell with dual glassy carbon working electrodes. One electrode was surface modified to act asglucose biosensor by immobilisation of glucose oxidase (GOx) (from Aspergillus niger) with 1% glutaraldehyde and bovine serum albumin. The second electrode (glucose oxidase omitted) was utilised to measure the interference signal responding only to electroactive species present in the injected sample. A computer controlled multichannel potentiostat was used for potential application and current monitoring duties. The sensor responses were saved in ASCII format to facilitate post-run analysis in Microsoft Excel. Cyclic voltammetry (CV) was utilised to investigate the manner in which the interference signal contributed to the total signal obtained at the biosensor in the presence of glucose. The kinetic parameters Imax and the apparent Michaelis-Menten constant, K′m, were calculated for the sensor operating under flow-injection conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号