首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 661 毫秒
1.
An opto-electrochemical sensor for copper (II) ion was developed. The sensor consists of a planar conductive indium-tin-oxide (ITO) glass support, which was coated by a polymeric copper (II) sensitive membrane. The sensing membrane is made of plasticized polyurethane matrix containing Zincon colorimetric reagent immobilized as ion pair with tetraoctylammonium ion. The instrumentation used commonly for wave-guide sensor development was extended with a potentiostat that made possible the control of the electric potential of the conductive surface. In this way the transport rate of ionic species through the membrane-sample interface could be influenced. In the presence of copper (II) ions the color of the membrane turned from red to blue, which was monitored optically. By applying positive potential to the conductive surface the direction of the ion diffusion at the membrane/sample interface was changed. As a result the sensing layer was regenerated within 2 minutes and was ready for further measurement. The sensor measured Cu(2+) ion in a concentration range of 1-200 microM.  相似文献   

2.
Laser microdissection is an invaluable tool in medical research that facilitates collecting specific cell populations for molecular analysis. Diversity of research targets (e.g., cancerous and precancerous lesions in clinical and animal research, cell pellets, rodent embryos, etc.) and varied scientific objectives, however, present challenges toward establishing standard laser microdissection protocols. Sample preparation is crucial for quality RNA, DNA and protein retrieval, where it often determines the feasibility of a laser microdissection project. The majority of microdissection studies in clinical and animal model research are conducted on frozen tissues containing native nucleic acids, unmodified by fixation. However, the variable morphological quality of frozen sections from tissues containing fat, collagen or delicate cell structures can limit or prevent successful harvest of the desired cell population via laser dissection. The CryoJane Tape-Transfer System®, a commercial device that improves cryosectioning outcomes on glass slides has been reported superior for slide preparation and isolation of high quality osteocyte RNA (frozen bone) during laser dissection. Considering the reported advantages of CryoJane for laser dissection on glass slides, we asked whether the system could also work with the plastic membrane slides used by UV laser based microdissection instruments, as these are better suited for collection of larger target areas. In an attempt to optimize laser microdissection slide preparation for tissues of different RNA stability and cryosectioning difficulty, we evaluated the CryoJane system for use with both glass (laser capture microdissection) and membrane (laser cutting microdissection) slides. We have established a sample preparation protocol for glass and membrane slides including manual coating of membrane slides with CryoJane solutions, cryosectioning, slide staining and dissection procedure, lysis and RNA extraction that facilitated efficient dissection and high quality RNA retrieval from CryoJane preparations. CryoJane technology therefore has the potential to facilitate standardization of laser microdissection slide preparation from frozen tissues.  相似文献   

3.
Membrane potentials of mouse parathyroid cells were measured by means of the intracellular microelectrode method. The membrane potential in external Krebs solution containing 2.5 mM of Ca++ was -23.6 +/- 0.4 mV (mean +/- standard error of mean). The low concentration of Ca++ (1.0 mM) caused hyperpolarization of the membrane potential to -61.7 +/- 0.8 mV. The membrane potential was proportional to the logarithm of the concentration of K ion in the solution of low Ca ion. The concentration of external Na+, C1- and HPO4-- had no effect on the membrane potential. The sigmoidal transition of membrane potentials was induced by the change of Ca ion concentration in the range from 2.5 to 1.0 mM. The change of the membrane potentials in low Ca ion is originated from increase in potassium permeability of the cell membrane. The similar sigmoidal changes of the membrane potentials were observed in the solution containing 4 to 3 mM of Sr ion. The Mg and Ba ion showed smaller effect on the membrane potential. The Goldman equation was extended to divalent ions. Appling the extended membrane potential equation, ratios of the permeability coefficients were obtained as follows: PK/PCa = 0.067 for 2.5 mM Ca++, 0.33 for 1.0 mM Ca++; PK/PSr = 0.08 for 4 mM Sr++ and 0.4 for 3 mM Sr++; PK/PMg = 0.5; PK/PBa = 0.67 for all range of concentration. The Hill constants of Sr ion and Ca ion were 20; the relationship between Sr ion and Ca ion was competitive. The Hill constants of Mg and Ba ion were 1 each. The Hill constant of Ca ion was depend of the temperature; nmax = 20 at 36 degrees C, n = 9 at 27 degrees C, n = 2 at 22 degrees C. The enthalpy of Ca-binding reaction was obtained from the Van't Hoff plot as 0.58 kcal. The activation energies of the K+ permeability increase were obtained from the Arrhenius plots as 3.3 kcal and 4 kcal. The difference, 0.7 kcal, corresponds to the enthalpy change of this reaction, of which value is close to that of the Ca-binding reaction.  相似文献   

4.
Laser capture microdissection (LCM) is used to isolate a concentrated population of individual cells or precise anatomical regions of tissue from tissue sections on a microscope slide. When combined with immunohistochemistry, LCM can be used to isolate individual cells types based on a specific protein marker. Here, the LCM technique is described for collecting a specific population of dopamine neurons directly labeled with tyrosine hydroxylase immunohistochemistry and for isolation of the dopamine neuron containing region of the ventral tegmental area using indirect tyrosine hydroxylase immunohistochemistry on a section adjacent to those used for LCM. An infrared (IR) capture laser is used to both dissect individual neurons as well as the ventral tegmental area off glass slides and onto an LCM cap for analysis. Complete dehydration of the tissue with 100% ethanol and xylene is critical. The combination of the IR capture laser and the ultraviolet (UV) cutting laser is used to isolate individual dopamine neurons or the ventral tegmental area when using PEN membrane slides. A PEN membrane slide has significant advantages over a glass slide as it offers better consistency in capturing and collecting cells, is faster collecting large pieces of tissue, is less reliant on dehydration and results in complete removal of the tissue from the slide. Although removal of large areas of tissue from a glass slide is feasible, it is considerably more time consuming and frequently leaves some residual tissue behind. Data shown here demonstrate that RNA of sufficient quantity and quality can be obtained using these procedures for quantitative PCR measurements. Although RNA and DNA are the most commonly isolated molecules from tissue and cells collected with LCM, isolation and measurement of microRNA, protein and epigenetic changes in DNA can also benefit from the enhanced anatomical and cellular resolution obtained using LCM.  相似文献   

5.
Laser axotomy followed by time-lapse microscopy is a sensitive assay for axon regeneration phenotypes in C. elegans1. The main difficulty of this assay is the perceived cost ($25-100K) and technical expertise required for implementing a laser ablation system2,3. However, solid-state pulse lasers of modest costs (<$10K) can provide robust performance for laser ablation in transparent preparations where target axons are "close" to the tissue surface. Construction and alignment of a system can be accomplished in a day. The optical path provided by light from the focused condenser to the ablation laser provides a convenient alignment guide. An intermediate module with all optics removed can be dedicated to the ablation laser and assures that no optical elements need be moved during a laser ablation session. A dichroic in the intermediate module allows simultaneous imaging and laser ablation. Centering the laser beam to the outgoing beam from the focused microscope condenser lens guides the initial alignment of the system. A variety of lenses are used to condition and expand the laser beam to fill the back aperture of the chosen objective lens. Final alignment and testing is performed with a front surface mirrored glass slide target. Laser power is adjusted to give a minimum size ablation spot (<1um). The ablation spot is centered with fine adjustments of the last kinematically mounted mirror to cross hairs fixed in the imaging window. Laser power for axotomy will be approximately 10X higher than needed for the minimum ablation spot on the target slide (this may vary with the target you use). Worms can be immobilized for laser axotomy and time-lapse imaging by mounting on agarose pads (or in microfluidic chambers4). Agarose pads are easily made with 10% agarose in balanced saline melted in a microwave. A drop of molten agarose is placed on a glass slide and flattened with another glass slide into a pad approximately 200 um thick (a single layer of time tape on adjacent slides is used as a spacer). A "Sharpie" cap is used to cut out a uniformed diameter circular pad of 13mm. Anesthetic (1ul Muscimol 20mM) and Microspheres (Chris Fang-Yen personal communication) (1ul 2.65% Polystyrene 0.1 um in water) are added to the center of the pad followed by 3-5 worms oriented so they are lying on their left sides. A glass coverslip is applied and then Vaseline is used to seal the coverslip and prevent evaporation of the sample.  相似文献   

6.
A potentiometric biosensor has been designed on the basis of glass pH-electrode with a sensing device of the microcellular polyelectrolytic coating containing urease. The polymeric walls of the coating are readily permeable for low-molecular weight compounds, including urea, but are impermeable for macromolecules. The main characteristics of the biosensor in various experimental solutions containing urea, low-molecular-weight salt, and buffer have been obtained. The sensor has been shown to be stable for at least three weeks. The standard curves of the sensor are linear in the range of urea concentrations from 0.2 to 20 mM.  相似文献   

7.
A monosodium glutamate (MSG) biosensor made by co-immobilized L-glutamate oxidase (L-GLOD) and L-glutamate dehydrogenase (L-GLDH) as the bio-component based on substrate recycling for highly sensitive MSG or L-glutamate determination, has been developed. Regeneration of MSG by substrate recycling provided an amplification of the sensor response. Higher signal amplification was found in the presence of ammonium ion. The sensor was standardized to determine MSG in the range of 0.02-3.0 mg/L. Linearity was obtained from 0.02 to 1.2 mg/L in presence of ammonium ion (10 mM) and NADPH (reduced nicotinamide adenine dinucleotide phosphate) (2 mM), but in absence of L-GLDH, the detection limit of MSG is confined to 0.1 mg/L. The apparent Km for MSG with L-GLOD-L-GLDH coupled reaction was 0.4451 mM but 1.9222 mM when only L-GLOD was immobilized. Cross linking with glutaraldehyde in the presence of bovine serum albumin (BSA) as a spacer molecule has been used for the method of immobilization. The response time of the sensor was 2 min. The optimum pH and temperature of the biosensor has been determined as 7+/-2 and 25+/-2 degrees C, respectively. The enzyme immobilized on the membrane was used for over 50 measurements. The standard error of the sample measurement was 4-5%. The activity of the enzyme-immobilized membrane was tested over a period of 60 days.  相似文献   

8.
An enzymatic membrane for application in the processes of decomposition and removal of urea from aqueous solutions was prepared: jack bean urease was immobilized on an aminated polysulphone membrane by adsorption. The inhibition of the system by boric acid was studied using procedures based on the MICHAELIS-MENTEN integrated equation (non-linear regression, and the linear transformations of WALKER and SCHMIDT, JENNINGS and NIEMANN, and BOOMAN and NIEMANN). The reaction was carried out in a 100 mM phosphate buffer of pH 7.0, containing 2 mM EDTA, obtained by neutralization of orthophosphoric acid with NaOH, at an initial urea concentration of 10 mM, and a temperature of 25 °C. The reaction was initiated by the addition of the enzyme to the urea solution, and was monitored by removing samples of the reaction mixture for NH3 determinations by the phenol-hypochlorite method until the urea was exhausted. The results were compared with those obtained earlier under the same reaction conditions for free urease and urease covalently immobilized on chitosan. The inhibition was found to be competitive, similar to that of the free enzyme and urease immobilized on chitosan, with inhibition constants Ki equal to 0.36, 0.19 and 0.60 mM. The results show that adsorption of the enzyme on a polysulphone membrane changed the enzyme to a lesser degree than covalent immobilization of the enzyme on a chitosan membrane.  相似文献   

9.
Present study highlights the importance of RF sputtered NiO thin film deposited on platinum coated glass substrate (NiO/Pt/Ti/glass) as a potential matrix for the realization of highly sensitive and selective uric acid biosensor. Uricase has been immobilized successfully onto the surface of NiO matrix by physical adsorption technique. The prepared bioelectrode (uricase/NiO/Pt/Ti/glass) is utilized for sensing uric acid using the cyclic voltammetry and UV visible spectroscopy techniques. The bioelectrode is found to exhibit highly efficient sensing response characteristics with high sensitivity of 1278.48 μA/mM; good linearity of 0.05-1.0 mM, and very low Michaelis-Menten constant (k(m)) of 0.17 mM indicating high affinity of uricase towards the analyte. The enhanced response is due to the development of NiO matrix with good electron transport property and nanoporous morphology for effective loading of enzyme with preferred orientation.  相似文献   

10.
A novel urea biosensor based on immobilised recombinant urease as sensitive element and ion sensitive field effect transistor as transducer was developed. Recombinant urease from E. coli with an increased Km was photoimmobilised in PVA/SbQ (poly(vinyl alcohol) containing styrylpyridinium) membrane and has demonstrated quite good performance as biosensitive element. Enzymatic field effect transistors based on such a bioselective element were studied in model buffer solutions. This biosensor demonstrated an extended dynamic range up to 80 mM, a quite good reproducibility (standard deviation of the sensor responses was approximately 2.5%, n= 20 for urea concentration 10 mM) and a high stability. Such characteristics fit with the analytical requirements needed for urea control in plasma and liquids used during renal dialysis.  相似文献   

11.
The reflection coefficient (sigma) and permeability (P) of urea and ethylene glycol were determined by fitting the equations of Kedem and Katchalsky (1958) to the change in light scattering produced by adding a permeable solute to a red cell suspension. The measurements incorporated three important modifications: (a) the injection artifact was eliminated by using echinocyte cells; (b) the use of an additional adjustable parameter (Km), the effective dissociation constant at the inner side of the membrane; (c) the light scattering is not directly proportional to cell volume (as is usually assumed) because refractive index and scattering properties of the cell depend on the intracellular permeable solute concentration. This necessitates calibrating for known changes in refractive index (by the addition of dextran) and cell volume (by varying the NaCl concentration). The best fit was for sigma = 0.95, Po = 8.3 X 10(-4) cm/s, and Km = 100 mM for urea and sigma = 1.0, Po = 3.9 X 10(-4) cm/s, and Km = 30 mM for ethylene glycol. The effects of the inhibitors copper, phloretin, p- chloromercuriphenylsulfonate, and 5,5'-dithiobis (2-nitro) benzoic acid on the urea, ethylene glycol, and water permeability were determined. The results suggest that there are three separate, independent transport systems: one for water, one for urea and related compounds, and one for ethylene glycol and glycerol.  相似文献   

12.
A new electrochemical enzymatic sensor based on the ion selective field effect transistors (ISFETs) and photocurable membrane was developed for the determination of urea. For the immobilization of urease on the gate surface of the ISFET a simple method, involving the use of liquid photocurable compositions on the basis of vinylpirollidone, oligouretanemetacrylate and oligocarbonatemetacrylate, was applied. The linearange of the response of the developed electrochemical sensor lies in the range 0.05-20 mM. The latter corresponds to the claims of the medical practice. The overall time of the analysis is 5-10 min. The effects of the buffer concentration and its pH as well as temperature and presence of ammonia ions in the measuring medium on the amplitude of the sensor response were estimated. The duration of sensor work is as shortest 40 days. The proposed sensor on the basis of the ISFET is promising for the express analysis of the level urea in blood, while the developed method of membrane preparation with entrapped enzyme can be combined with the integral technology of producing of the biosensors semiconductor transducers.  相似文献   

13.
An urea biosensor based on urease-BSA (bovine serum albumin) membrane immobilised on the surface of an ion-sensitive field effect transistor (ISFET) has been studied in a mix buffer solution composed of potassium phosphate, Tris, citric acid and sodium tetraborate. In this mix buffer, the biosensor showed a dynamic larger than the one observed in a phosphate or Tris buffer. Investigation of the individual effect of each component of the buffer solution on the biosensor response has shown that tetraborate anion acts as a strong competitive inhibitor for the hydrolysis reaction of urea catalysed by urease. The biosensor response was investigated in a phosphate buffer with different concentrations of tetraborate anion. The results showed that the apparent constant of Michaelis-Menten, K(m(app)), increases from 4.3 to 79.3 mM, for experiments realised without and with 0.5 mM sodium tetraborate, respectively. The mean value, determined graphically, for the inhibition constant, K(i), was 29 microM. The graphical representation of biosensor calibration curves in semilogarithmic co-ordinates showed that the linear range of the biosensor can be extended up to three orders of magnitude, allowing an urea detection in a concentration range 0-100 mM.  相似文献   

14.
A new matrix for enzyme immobilization of urease was obtained by incorporating rhodium nanoparticles (5% on activated charcoal) and chemical bonding of chitosan with different concentration (0.15%; 0.3%; 0.5%; 1.0%; 1.5%) in previously chemically modified AN copolymer membrane. The basic characteristics of the chitosan modified membranes were investigated. The SEM analyses were shown essential morphology change in the different modified membranes. Both the amount of bound protein and relative activity of immobilized enzyme were measured. A higher activity (about 77.44%) was measured for urease bound to AN copolymer membrane coated with 1.0% chitosan and containing rhodium nanoparticles. The basic characteristics (pH(opt), T(opt), thermal, storage and operation stability) of immobilized enzyme on this optimized modified membrane were also determined. The prepared enzyme membrane was used for the construction of amperometric biosensor for urea detection. Its basic amperometric characteristics were investigated. A calibration plot was obtained for urea concentration ranging from 1.6 to 23 mM. A linear interval was detected along the calibration curve from 1.6 to 8.2mM. The sensitivity of the constructed biosensor was calculated to be 3.1927 μAmM(-1)cm(-2). The correlation coefficient for this concentration range was 0.998. The detection limit with regard to urea was calculated to be 0.5mM at a signal-to-noise ratio of 3. The biosensor was employed for 10 days while the maximum response to urea retained 86.8%.  相似文献   

15.
M R Lifsics  R C Williams 《Biochemistry》1984,23(13):2866-2875
The 68 000-dalton protein from bovine neurofilaments was purified by a combination of chromatography on DEAE-cellulose and on hydroxylapatite in buffers containing 8 M urea. Although the separation of this protein from the other proteins of the neurofilament appeared to be hampered by a mixed association of the several components, a nearly homogeneous product was obtained for study. Sedimentation equilibrium experiments in buffers containing 8 M urea showed the molecule to be a monomer with a molecular weight of 70 600 +/- 2000. Circular dichroic spectra taken under the same conditions gave no evidence of residual alpha-helix. Molecular sieve chromatography in 8 M urea on controlled-pore glass showed that the molecule eluted at an unexpectedly small volume. The small elution volume did not depend significantly on protein concentration and is unlikely to be the result of intermolecular association. Rather, the monomer probably has a conformation more rigid or extended than a classical random coil. When dialyzed into 0.01 M tris(hydroxymethyl)aminomethane/1 mM ethylene glycol bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid/0.1 mM dithioerythritol, pH 8.5, the protein does not assemble into filaments. Sedimentation velocity reveals that under these conditions it consists mainly of a 4.8S molecular species, containing few large particles; sedimentation equilibrium shows that it is composed of oligomers, the smallest present in significant concentration having a molecular weight approximately that of a trimer. Circular dichroism measurements lead to the interpretation that the molecule has refolded in this buffer into a structure that has approximately 55% alpha-helix. Assembly into filamentous particles resembling neurofilaments occurs when the protein is dialyzed against 0.1 M 2-(N-morpholino)ethane-sulfonic acid/0.1% beta-mercaptoethanol/1 mM ethylene glycol bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid/0.17 M NaCl, pH 6.5. We suggest that the oligomeric species present in 0.01 M tris(hydroxymethyl)aminomethane may frequently be present in solubilized preparations of intermediate filaments and may represent an intermediate in the assembly process.  相似文献   

16.
The mechanism of ion transport in the epithelium of rabbit cornea was studied by determining the intracellular ion activity of Cl-, Na+ and K+ under various conditions. Ionic activities were measured by means of microelectrodes containing liquid ion-exchangers selective for Cl-, Na+ or K+. The Cl- activity in basal cells of the epithelium in Na+ containing bathing solutions amounts to 28 +/- 2 mM (n = 11). This value is 1.9-times greater than expected on the basis of passive distribution across the tear side membrane. This finding suggests the existence of a Cl- accumulating process. Replacement of Na+ in the aqueous bathing solution by choline or tetraethylammonium results in a reversible decrease in Cl- activity to 22 +/- 1 mM (n = 11, P less than 0.025). The ratio of observed and predicted Cl- activity decreased significantly from 1.9 to 1.4 (P less than 0.05). The decrease in Cl- activity due to Na+ replacement was rather slow. In contrast, after readmittance of Na+ to the aqueous bathing solution, Cl- activity rose to a stable level within 30 min. These results indicate involvement of Na+ in Cl- accumulation into the basal cells of the epithelium. The K+ and Na+ activities of the basal cells of rabbit corneal epithelium in control bathing solutions were 75 +/- 4 mM (n = 13) and 24 +/- 3 mM (n = 12), respectively. The results can be summarized in the following model for Cl- transport across corneal epithelium. Cl- is accumulated in the basal cells across the aqueous side membrane, energized by a favourable Na+ gradient. Cl- will subsequently leak out across the tear side membranes. Na+ is extruded again across the aqueous side membrane of the epithelium by the (Na+ + K+)-ATPase.  相似文献   

17.
Several amines were shown to inhibit growth stimulation in quiescent confluent and sparse cultures of Swiss 3T3 and 3T6 cells by changing for a fresh medium containing 10-20% serum. Proliferation was inhibited by dansylcadaverine (0.1 mM), chloroquine (0.05 mM), 5-methoxytryptamine (0.1 mM), cystamine (0.1 mM), dimethylurea (100 mM), methylurea (100 mM), and in some experiments--by urea (100 mM). The inhibitory activity was not associated with a direct influence of amines on DNA synthesis or thymidine phosphorylation. The findings suggest that amines may influence the process of clustering of growth factor-receptor complexes, or the fusion of plasma membrane and intracellular vesicles containing some components required for cell proliferation.  相似文献   

18.
Voltage-gated ion channels are key players in cellular excitability. Recent studies suggest that their behavior can depend strongly on the membrane lipid composition and physical state. In vivo studies of membrane/channel and channel/channel interactions are challenging as membrane properties are actively regulated in living cells, and are difficult to control in experimental settings. We developed a method to reconstitute functional voltage-gated ion channels into cell-sized Giant Unilamellar Vesicles (GUVs) in which membrane composition, tension and geometry can be controlled. First, a voltage-gated potassium channel, KvAP, was purified, fluorescently labeled and reconstituted into small proteoliposomes. Small proteoliposomes were then converted into GUVs via electroformation. GUVs could be formed using different lipid compositions and buffers containing low (5 mM) or near-physiological (100 mM) salt concentrations. Protein incorporation into GUVs was characterized with quantitative confocal microscopy, and the protein density of GUVs was comparable to the small proteoliposomes from which they were formed. Furthermore, patch-clamp measurements confirmed that the reconstituted channels retained potassium selectivity and voltage-gated activation. GUVs containing functional voltage-gated ion channels will allow the study of channel activity, distribution and diffusion while controlling membrane state, and should prove a powerful tool for understanding how the membrane modulates cellular excitability.  相似文献   

19.
A urea biosensor was developed using the urease entrapped in polyvinyl alcohol (PVA) and polyacrylamide (PAA) composite polymer membrane. The membrane was prepared on the cheesecloth support by gamma-irradiation induced free radical polymerization. The performance of the biosensor was monitored using a flow-through cell, where the membrane was kept in conjugation with the ammonia selective electrode and urea was added as substrate in phosphate buffer medium. The ammonia produced as a result of enzymatic reaction was monitored potentiometrically. The potential of the system was amplified using an electronic circuit incorporating operational amplifiers. Automated data acquisition was carried by connecting the output to a 12-bit analog to digital converter card. The sensor working range was 1–1000 mM urea with a response time of 120 s. The enzyme membranes could be reused 8 times with more than 90% accuracy. The biosensor was tested for blood urea nitrogen (BUN) estimation in clinical serum samples. The biosensor showed good correlation with commercial Infinity™ BUN reagent method using a clinical chemistry autoanalyzer. The membranes could be preserved in phosphate buffer containing dithiothreitol, β-mercaptoethanol and glycerol for a period of two months without significant loss of enzyme activity.  相似文献   

20.
A novel type of bioelectronic region ion sensitive field effect transistor (RISFET) nanosensor was constructed and demonstrated on two different sensor chips that could measure glucose with good linearity in the range of 0–0.6 mM and 0–0.3 mM with a limit of detection of 0.1 and 0.04 mM, respectively. The sensor is based on the principle of focusing charged reaction products with an electrical field in a region between the sensing electrodes. For glucose measurements, negatively charged gluconate ions were gathered between the sensing electrodes. The signal current response was measured using a low-noise pico ammeter (pA). Two different sizes of the RISFET sensor chips were constructed using conventional electron beam lithography. The measurements are done in partial volumes mainly restricted by the working distance between the sensing electrodes (790 and 2500 nm, respectively) and the influence of electrical fields that are concentrating the ions. The sensitivity was 28 pA/mM (2500 nm) and 830 pA/mM (790 nm), respectively. That is an increase in field strength by five times between the sensing electrodes increased the sensitivity by 30 times. The volumes expressed in this way are in low or sub femtoliter range. Preliminary studies revealed that with suitable modification and control of parameters such as the electric control signals and the chip electrode dimensions this sensor could also be used as a nanobiosensor by applying single enzyme molecule trapping. Hypotheses are given for impedance factors of the RISFET conducting channel.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号