首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A heme protein hemoglobin (Hb) was reacted with preexfoliated layered alpha-zirconium phosphate (alpha-ZrP) platelets. An X-ray diffraction (XRD) pattern of small range showed that the exfoliated alpha-ZrP platelets reassembled after the addition of Hb molecules, with the protein intercalated between the layers. UV-Vis and Fourier transform infrared (FTIR) spectra analysis displayed that no significant denaturation occurred to the intercalated protein. The bioactivity of Hb was also investigated by testing the electrochemical properties of the Hb/alpha-ZrP composite. Results showed that the intercalation of Hb into the layered material not only improved the thermal stability of Hb but also enhanced the direct electron transfer ability between protein molecules and electrode. The protein still showed bioactivity after treatment at a temperature as high as 85 degrees C. A pair of well-defined redox peaks at approximately -0.37 and -0.32V was observed on the cyclic voltammograms (CVs) of the Hb/alpha-ZrP composite modified electrode, and the electrode reactions showed a surface-controlled process with a single proton transfer. The resultant biosensor constructed by the Hb/alpha-ZrP composite displayed an excellent response to the reduction of hydrogen peroxide (H(2)O(2)) with good reproducibility.  相似文献   

2.
The electrochemistry of L-cysteine (CySH) in neutral aqueous media was investigated using carbon ionic liquid electrode (CILE). Comparative experiments were carried out using glassy carbon electrodes. At CILE, highly reproducible and well-defined cyclic voltammograms were obtained for l-cysteine with a peak potential of 0.49V vs Ag/AgCl, showing that CILE manifests a good electrocatalytic activity toward oxidation of l-cysteine. A linear dynamic range of 2-210microM with an experimental detection limit of 2microM was obtained. The method was successfully applied to the determination of l-cysteine in a sample of soya milk. Cysteine oxidation at CILE does not result in deactivation of the electrode surface. Mechanistic studies showed that, at CILE, the overall CySH oxidation is controlled by the oxidation of the CyS(-) electroactive species.  相似文献   

3.
The direct electrical communication between hemoglobin (Hb) and GCE surface was achieved based on the immobilization of Hb in a cationic gemini surfactant film and characterized by electrochemical techniques. The cyclic voltammograms showed that direct electron transfer between Hb and electrode surface was obviously promoted and then a novel unmediated nitric oxide (NO) biosensor was constructed in view of this protein-based electrode. This modified electrode showed an enzyme-like activity towards the reduction of NO and its amperometric response to NO was well-behaved with a rapid response time and displaying Michaelis-Menten kinetics with a calculated Km(app) value of 84.37 micromol L(-1). The detection limit was estimated to be 2.00 x 10(-8)mol L(-1). This biosensor was behaving as expected that it had a good stability and reproducibility, a higher sensitivity and selectivity and should has a potential application in monitoring NO released from biologic samples.  相似文献   

4.
Dai Z  Bai H  Hong M  Zhu Y  Bao J  Shen J 《Biosensors & bioelectronics》2008,23(12):1869-1873
A novel nitrite biosensor based on the direct electron transfer of hemoglobin (Hb) immobilized on CdS hollow nanospheres (HS-CdS) modified glassy carbon electrode was constructed. The direct electron transfer of Hb showed a pair of redox peaks with a formal potential of -286 mV (vs. SCE) in 0.1M pH 7.0 phosphate buffer solution. It was a surface-controlled electrode process involving a single proton transfer coupled with a reversible one-electron transfer for each heme group of Hb. HS-CdS had a large specific surface area and good biocompatibility and had a better electrochemical response than that of solid spherical CdS. The immobilized Hb on HS-CdS displayed an excellent response to NO(2)(-) with one irreversible electrode process for NO reduction. Under optimal conditions, the biosensor could be used for the determination of NO(2)(-) with a linear range from 0.3 to 182 microM and a detection limit of 0.08 microM at 3 sigma based on the irreversible reduction of NO. HS-CdS provided a good matrix for protein immobilization and had a promising application in constructing sensors.  相似文献   

5.
Direct electrochemical and electrocatalytic behaviors of hemoglobin (Hb) immobilized on carbon paste electrode (CPE) by a silica sol-gel film derived from tetraethylorthosilicate (TEOS) were investigated for the first time. Hb/sol-gel film modified electrodes showed a pair of well-defined and nearly reversible cyclic voltammetric peaks for Hb Fe(III)/Fe(II) redox couple at about -0.312 V (versus Ag/AgCl) in a pH 7.0 phosphate buffer. The formal potential of Hb heme Fe(III)/Fe(II) couple varied linearly with the increase of pH in the range of 5.0-10.0 with a slope of 49.44 mV pH(-1), which suggests that a proton transfer is accompanied with each electron transfer (ET) in the electrochemical reaction. The immobilized Hb displayed the features of peroxidase and gave excellent electrocatalytic performance to the reduction of O2, NO2(-) and H2O2. The calculated apparent Michaelis-Menten constant was 8.98 x 10(-4)M, which indicated that there was a large catalytic activity of Hb immobilized on CPE by sol-gel film toward H2O2. In comparison with other electrodes, the chemically modified electrodes, used in this direct electrochemical study of Hb, are easy to be fabricated and rather inexpensive. Consequently, the Hb/sol-gel film modified electrode provides a convenient approach to perform electrochemical research on this kind of proteins. It also has potential use in the fabrication of the third generation biosensors and bioreactors.  相似文献   

6.
Direct electrochemistry and thermal stability of hemoglobin (Hb) immobilized on a nanometer-sized zirconium dioxide (ZrO2) modified pyrolytic graphite (PG) electrode were studied. The immobilized Hb displayed a couple of stable and well-defined redox peaks with an electron transfer rate constant of (7.90 +/- 0.93)s(-1) and a formal potential of -0.361 V (-0.12 V versus NHE) in 0.1M pH 7.0 PBS. Both nanometer-sized ZrO2 and dimethyl sulfoxide (DMSO) could accelerate the electron transfer between Hb and the electrode. Spectroscopy analysis of the Hb/ZrO2/DMSO film showed that the immobilized Hb could retain its natural structure. This modified electrode showed a high thermal stability up to 74 degrees C and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging from 1.5 to 30.2 microM with a detection limit of 0.14 microM at 3sigma. The apparent Michaelis-Menten constant KMapp for H2O2 sensor was estimated to be (0.31 +/- 0.02) mM, showing a high affinity.  相似文献   

7.
Hemoglobin (Hb) was successfully immobilized in dimethyldioctadecyl ammonium bromide (DOAB) film at pyrolytic graphite (PG) electrode. Electrochemical experiments revealed that Hb in DOAB film exhibited a pair of well-defined, quasi-reversible cyclic voltammetric peaks at about -0.160 V versus saturated calomel electrode (SCE) in pH 5.0 buffer, characteristic of the heme Fe(III)/Fe(II) redox couple of Hb. The electron transfer (eT) rate between Hb and the PG electrode was 0.10 s(-1). Positions of the Soret absorbance band indicated that the Hb retained its secondary structure and was similar to its native state. Furthermore, the Hb in DOAB film acted as a biological catalyst towards the reduction of nitric oxide (NO). The voltammetric response of NO at the Hb-DOAB modified electrode could be used to determine the concentration of NO in solution.  相似文献   

8.
In this study, poly(varepsilon-caprolactone) (PCL) was synthesized using the varepsilon-caprolactone (CL) monomer ring-opening polymerization. We demonstrated that the hemoglobin (Hb) entrapped in PCL film could retain its original conformation by FT-IR spectra. A pair of well-defined redox peaks with a formal potential (E0') of about -0.38V (vs. SCE) in a pH 7.0 phosphate buffer solution was obtained at the Hb-PCL film modified GC electrode. The dependence of [Formula: see text] on the pH of the buffer solution indicated that the conversion of heme Fe(III)/Fe(II) was a reaction of one electron coupled to one proton. The apparent heterogeneous electron transfer rate constants (ks) of Hb confined to PCL was valuated as (18.7+/-0.8)s(-1) according to Laviron's equation. The surface concentration (Gamma*) of the electroactive Hb in the PCL film was estimated to be (7.27+/-0.57)x10(-11)molcm(-2). The Hb-PCL film modified electrode was shown to be an excellent amperometric sensor for the detection of hydrogen peroxide. The linear range is from 2 to 30microM with a detection limit of 6.07x10(-6)M. The sensor was effectively testified by the determination of the hydrogen peroxide in eyedrops as real samples.  相似文献   

9.
A highly sensitive and selective amperometric hydrogen peroxide (H(2)O(2)) biosensor based on immobilization of hemoglobin (Hb) at multiwalled carbon nanotubes-zinc oxide (MWCNT/ZnO) composite modified glassy carbon electrode (GCE) is reported. ZnO microsponges were electrochemically grown on MWCNT surface by the simple, cost-effective, green, electrochemical method at room temperature. The MWCNT/ZnO/Hb composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E°') of -0.336V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.26s(-1). The developed biosensor showed a very fast response (>2s) toward H(2)O(2) with good sensitivity, wide linear range, and low detection limit of 0.02μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of MWCNT, and good biocompatibility of ZnO. The fabrication method of this biosensor is simple and effective for determination of H(2)O(2) in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery.  相似文献   

10.
In this work, a novel sensing scaffold, consisting Au nanoparticle (GNP)-dotted TiO(2) nanotubes (TNTs) as the rigid material and the hydrophobic ionic liquid (HIL), 1-decyl-3-methylimidazolium tetrafluoroborate, as the entrapping agent, was applied to facilitate the electron transfer of horseradish peroxidase (HRP) on a glassy carbon electrode. GNPs were immobilised on the TNTs in our work using a one-step reduction of HAuCl(4)·3H(2)O by sodium borohydride in the presence of sodium citrate as a stabilising reagent. The morphology and composition of the as-synthesised composite materials were characterised by transmission electron microscopy, scanning electron microscopy, X-ray diffraction and Fourier-transform infrared spectroscopy. Cyclic voltammetry of HRP at the modified electrode presented a pair of reproducible, quasi-reversible redox peaks with a peak-to-peak separation of 69 mV, indicating electron transfer between HRP and composite electrode. The GNP-TNT|HIL|HRP electrode was then applied to the detection of H(2)O(2) in a pH 7.0 phosphate buffer using chronoamperometry. The biosensor exhibited a linear response in the 15-750 μM range, and a limit of detection of 2.2 μM. The biosensor also exhibited stability with 90% of the detection signal retained over a two-week duration.  相似文献   

11.
A stable suspension of carbon nanotube (CNT) can be obtained by dispersing the CNT in the solution of the surfactant cetyltrimethylammonium bromide. CNT has promotion effects on the direct electron transfer of hemoglobin (Hb), which was immobilized onto the surface of CNT. The direct electron transfer rate of Hb was greatly enhanced after it was immobilized onto the surface of CNT. Cyclic voltammetric results showed a pair of well-defined redox peaks, which corresponded to the direct electron transfer of Hb, with the formal potential (E0) at about −0.343 V (vs. saturated calomel electrode) in the phosphate buffer solution (pH 6.8). The electrochemical parameters such as apparent heterogeneous electron transfer rate constant (ks) and the value of formal potential (E0) were estimated. The dependence of E0 on solution pH indicated that the direct electron transfer reaction of Hb is a one-electron transfer coupled with a one-proton transfer reaction process. The experimental results also demonstrated that the immobilized Hb retained its bioelectrocatalytic activity to the reduction of H2O2. The electrocatalytic current was proportional to the concentration of H2O2 at least up to 20 mM.  相似文献   

12.
Flowerlike, spherical, and walnutlike NiO microspheres were respectively mixed with ionic liquid (IL) to form three stable composite films, which were used to immobilize hemoglobin (Hb) on carbon paste electrodes. Spectroscopic and electrochemical examinations revealed that the three NiO/IL composites were biocompatible matrix for immobilizing Hb, which showed good stability and bioactivity. However, electrochemical studies demonstrated that flowerlike NiO microspheres were far more effective than the other two in adsorbing Hb and facilitating the electron transfer between Hb and underlying electrode, which resulted from its unique flower architecture and large surface area. With advantages of flowerlike NiO and ionic liquid, a pair of stable and well-defined quasi-reversible redox peaks of Hb were obtained with a formal potential of -0.275 V (vs. Ag/AgCl) in pH 7.0 buffer. Meantime, flowerlike NiO modified electrode showed better electrocatalytic activity toward hydrogen peroxide reduction with a high sensitivity (15.7μAmM(-1)), low detection limit (0.68 μM) and small apparent Michaelis-Menten constant K(M) (0.18 mM). Flowerlike NiO could be a promising matrix for the fabrication of direct electrochemical biosensors in biomedical analysis.  相似文献   

13.
Dai Z  Xiao Y  Yu X  Mai Z  Zhao X  Zou X 《Biosensors & bioelectronics》2009,24(6):1629-1634
The direct electron transfer of myoglobin (Mb) was realized by immobilizing Mb onto ionic liquid (1-butyl-3-methyl imidazolium tetrafluoraborate, [bmim][BF(4)])-clay composite film modified glassy carbon electrode. A pair of well-defined redox peaks of Mb with a formal potential (E(o)') of -0.297 V (vs. Ag/AgCl) was observed in 0.1M phosphate buffer solution (pH 6.0). The ionic liquid-clay composite film showed good biocompatibility and an obvious promotion capability for the direct electron transfer between Mb and electrode. The electron transfer rate constant (k(s)) of Mb was calculated to be (3.58+/-0.12)s(-1). UV-vis spectrum suggested that Mb retained its native conformation in the ionic liquid-clay system. Basal plane spacing of clay obtained by X-ray diffraction (XRD) indicated that there was an intercalation-exfoliation-restacking process, in ionic liquid and clay during the drying process of the modification, and the ionic liquid played the key role for promotion of the direct electron transfer between Mb and the ionic liquid-clay composite film modified electrode. The biocatalytic activity of Mb in the composite film was exemplified by the reduction of hydrogen peroxide. Under the optimal conditions, the reduction peak currents of Mb increased linearly with the concentration of H(2)O(2) in the range of 3.90 x 10(-6) to 2.59 x 10(-4)M, with a detection limit of 7.33 x 10(-7)M. The kinetic parameter I(max) and the apparent Michaelis constant (K(m)) for the electrocatalytic reactions were 3.87 x 10(-8)A and 17.6 microM, respectively. The proposed method would be valuable for the construction of a new third-generation H(2)O(2) sensor.  相似文献   

14.
Shan D  Han E  Xue H  Cosnier S 《Biomacromolecules》2007,8(10):3041-3046
A highly stable biological film was formed on the functional glassy carbon electrode (GCE) via step-by-step self-assembly of chitosan (CHT), laponite, and hemoglobin (Hb). Cyclic voltammetry (CV) of the Hb/laponite/CHT/GCE showed a pair of stable and quasi-reversible peaks for the Hb-Fe(III)/Fe(II) redox couple at about -0.035 V versus a saturated calomel electrode in pH 6.0 phosphate buffer at a scan rate of 0.1 V s(-1). The electrochemical reaction of Hb entrapped on the laponite/CHT self-assembled film exhibited a surface-controlled electrode process. The formal potential of the Hb-heme-Fe(III)/Fe(II) couple varied linearly with the increase of pH over the range of 3.0-8.0 with a slope of -63 mV pH(-1), which implied that an electron transfer was accompanied by single-proton transfer in the electrochemical reaction. The position of the Soret absorption band of this self-assembled Hb/laponite/CHT film suggested that the entrapped Hb kept its secondary structure similar to its native state. The self-assembled film showed excellent long-term stability, the CV peak potentials kept in the same positions, and the cathodic peak currents retained 90% of their values after 60 days. The film was used as a biological catalyst to catalyze the reduction of hydrogen peroxide. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging widely from 6.2 x 10(-6) to 2.55 x 10(-3) M with a detection limit of 6.2 x 10(-6) M at 3 sigma.  相似文献   

15.
Cyclic voltammetry at potential range − 1.1 to 0.5 V from aqueous buffer solution (pH 7) containing CoCl2 produced a well defined cobalt oxide (CoOx) nanoparticles deposited on the surface of glassy carbon electrode. The morphology of the modified surface and cobalt oxide formation was examined with SEM and cyclic voltammetry techniques. Hemoglobin (Hb) was successfully immobilized in cobalt-oxide nanoparticles modified glassy carbon electrode. Immobilization of hemoglobin onto cobalt oxide nanoparticles have been investigated by cyclic voltammetry and UV–visible spectroscopy. The entrapped protein can take direct electron transfer in cobalt-oxide film. A pair of well defined, quasi-reversible cyclic voltammetric peaks at about − 0.08 V vs. SCE (pH 7), characteristic of heme redox couple (Fe(III)/Fe(II)) of hemoglobin, and the response showed surface controlled electrode process. The dependence of formal potential (E0′) on the solution pH (56 mV pH− 1) indicated that the direct electron transfer reaction of hemoglobin was a one-electron transfer coupled with a one proton transfer reaction process. The average surface coverage of Hb immobilized on the cobalt oxide nanoparticles was about 5.2536 × 10− 11 mol cm− 2, indicating high loading ability of nanoparticles for hemoglobin entrapment. The heterogeneous electron transfer rate constant (ks) was 1.43 s− 1, indicating great of facilitation of the electron transfer between Hb and electrodeposited cobalt oxide nanoparticles. Modified electrode exhibits a remarkable electrocatalytic activity for the reduction of hydrogen peroxide and oxygen. The Michaels–Menten constant Km of 0.38 mM, indicating that the Hb immobilized onto cobalt oxide film retained its peroxidases activity. The biosensor exhibited a fast amperometric response < 5 s, a linear response over a wide concentration range 5 μM to 700 μM and a low detection limit 0.5 μM. According to the direct electron transfer property and enhanced activity of Hb in cobalt oxide film, a third generation reagentless biosensor without using any electron transfer mediator or specific reagent can be constructed for determination of hydrogen peroxide in anaerobic solutions.  相似文献   

16.
The direct electrochemistry of lactate dehydrogenase (LDH) immobilized in silica sol-gel film on gold electrode was investigated, and an obvious cathodic peak at about -200 mV (versus SCE) was found for the first time. The LDH-modified electrode showed a surface controlled irreversible electrode process involving a one electron transfer reaction with the charge-transfer coefficient (alpha) of 0.79 and the apparent heterogeneous electron transfer rate constant (K(s)) of 3.2 s(-1). The activated voltammetric response and decreased charge-transfer resistance of Ru(NH(3))(6)(2+/3+) on the LDH-modified electrode provided further evidence. The surface morphologies of silica sol-gel and the LDH embedded in silica sol-gel film were characterized by SEM. A potential application of the LDH-modified electrode as a biosensor for determination of lactic acid was also investigated. The calibration range of lactic acid was from 2.0 x 10(-6) to 3.0 x 10(-5) mol L(-1) and the detection limit was 8.0 x 10(-7) mol L(-1) at a signal-to-noise ratio of 3. Finally, the effect of environmental pollutant resorcinol on the direct electrochemical behavior of LDH was studied. The experimental results of voltammetry indicated that the conformation of LDH molecule was altered by the interaction between LDH and resorcinol. The modified electrode can be applied as a biomarker to study the pollution effect in the environment.  相似文献   

17.
We synthesized a kind of gold nanoparticle protected by a synthetic lipid (didodecyldimethylammonium bromide, DDAB). With the help of these gold nanoparticles, hemoglobin can exhibit a direct electron transfer (DET) reaction. The formal potential locates at -169 mV vs. Ag/AgCl. Spectral data indicated the hemoglobin on the electrode was not denatured. The lipid-protected gold nanoparticles were very stable (for at least 8 months). Their average diameter is 6.42 nm. It is the first time to use monolayer-protected nanoparticles to realize the direct electrochemistry of protein.  相似文献   

18.
Lu X  Hu J  Yao X  Wang Z  Li J 《Biomacromolecules》2006,7(3):975-980
A novel polymer/room-temperature ionic liquid (RTIL) composite material based on chitosan (Chi) and 1-butyl-3-methyl-imidazolium tetrafluoroborate (BMIM.BF(4)) was explored. The composite system can be readily used as an immobilization matrix to entrap proteins and enzymes. Hemoglobin (Hb) was chosen as a model protein to investigate the composite system. A pair of well-defined quasireversible redox peaks of hemoglobin were obtained at the Chi-BMIM.BF(4)-Hb composite-film-modified glassy carbon (GC) electrode by direct electron transfer between the protein and the GC electrode. Dramatically enhanced biocatalytic activity was exemplified at the Chi-BMIM.BF(4)-Hb/GC electrode by the reduction of oxygen and trichloroacetic acid. Thermogravimetric analysis (TGA) suggests that the Chi-BMIM.BF(4)-Hb composite has higher thermal stability than Chi-Hb itself. The Chi-BMIM.BF(4)-Hb film was also characterized by UV-visible spectra, indicating excellent stability in solution and good biocompatibility for protein. The unique composite material based on polymer and ionic liquid can find wide potential applications in direct electrochemistry, biosensors, and biocatalysis.  相似文献   

19.
Ferricyanide ions were immobilized on a platinum electrode surface by means of an electrochemically grown polypyrrole film. The entrapped Fe(CN)6(3-)/Fe(CN)6(4-) redox system displayed a high heterogeneous electron transfer rate. The resulting modified electrode was efficient for the ferricyanide-mediated NADH oxidation catalyzed by a diaphorase. The bioelectrochemical interface was applied to the design of a reagentless amperometric D-lactate biosensor. A weakly polarized two polypyrrole-containing Fe(CN)6(3-) modified electrode system was involved without any reference. An enzymatic solution containing D-lactate dehydrogenase, diaphorase and NAD-dextran was further confined on the sensing electrode using a semi-permeable membrane. The sensitivity and the response time of the reagentless biosensor were similar to those of the analogous sensor working with soluble mediator and cofactor, i.e. 25 microA mM(-1) cm(-2) and 120 s, respectively. The other analytical performances were less satisfactorily: the detection limit was 5 x 10 mmol L(-1) and the linearity range was comprised between 0.1 and 0.5 mmol L(-1).  相似文献   

20.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号