首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Incorporation of lipopolysaccharide (LPS) into liposomes dramatically reduces its ability to coagulateLimulusamebocyte lysate (LAL). The coagulation of LAL is commonly used to signal the presence of endotoxinin vitro.This study demonstrates a simple method to release masked endotoxin from liposomal dispersions using moderate amounts of detergent to form mixed micelles containing lipid, detergent, and LPS. Several parameters were found to affect the degree of liposome solubilization and/or the sensitivity of the LAL assay. These included detergent type and concentration, temperature for solubilization, lipid composition, liposome morphology, and time for test incubation. The nonionic detergent polyoxyethylene 10 lauryl ether (C12E10) proved to be unique in its ability to solubilize liposomes and minimally interfere with endotoxin detection. The LAL endotoxin detection limit for samples dispersed in C12E10varied with the phospholipid component; the sensitivity decreased in the order DSPC > DPPC = EPC DMPC. Cholesterol lowered the solubility limit of the liposomes, but did not appear to affect the LAL assay sensitivity once the liposomes were completely solubilized. The presence of negatively charged phospholipids, DSPG and Pops, also lowered the solubility limit. Pops, but not DSPG, at 10 mol% further decreased the LAL endotoxin detection limit. This detergent-solubilization method should be useful in liposomal LPS immunological studies or in other situations where accurate determination of endotoxin concentration is important.  相似文献   

2.
With the help of immunofluorescent diagnostic system (specific immunoglobulins against glycolipid of S. minnesota Re-595) has been shown to permit the detection of endotoxin into eosinophil. Statistically significant differences in the occurrence of endotoxin in eosinophils of patients and healthy persons have been revealed. These data allow us to suppose that eosinophils are superaffined endotoxin-interaction cells of the human blood. Eosinopenia may be taken into account as an indirect marker of systemic LPS O-antigen mediated endotoxinemia.  相似文献   

3.
The purpose of this study was to determine the role of endotoxins in the etiology of coliform mastitis /CM/ in sows under field conditions, by using the Limulus amebocyte lysate /LAL/ test for the detection of endotoxins in the blood of pigs. For this purpose, blood samples from 40 healthy sows and 46 sows with clinical signs of CM were drawn once between 24 and 72 h post partum and tested accordingly. Only one clinically healthy sow 2.5% showed the presence of endotoxins in the serum. In sows clinically affected with one or more symptoms of the CM, the bacterial toxins were detected in 15 cases /32.5%/. The results of these studies support the observation that in only a certain percentage of all CM cases the occurrence of endotoxin in blood can be shown. Sampling time in relation to the occurrence of clinical symptoms and sampling frequency may have had an influence on the detectability of circulating endotoxins. Consequently, not all cases with endotoxemia may have been identified. The usefulness of the LAL test for endotoxin detection in the blood of pigs was confirmed.  相似文献   

4.
The rabbit pyrogen test and Limulus amoebocyte lysate (LAL) assay have been used to detect endotoxins in vaccines, but interactions between the endotoxins and proteins or aluminum hydroxide can interfere with the results. Currently, the rabbit pyrogen test is used to detect endotoxin in hepatitis B (HB) vaccines even though the HB surface protein, the active ingredient, is over-expressed in and purified from eukaryotic cells which lack endotoxin. Therefore, we examined the possibility of replacing the animal tests with the more efficient LAL test. To this end, we determined whether the aluminum hydroxide in the HB vaccines affects the rabbit pyrogen test and the LAL assay. HB vaccines and HB protein solutions spiked with lipopolysaccharide (LPS) produced almost the same dose-dependent temperature rise in rabbits, indicating that the aluminum hydroxide in the HB vaccine does not interfere with the pyrogenic response in rabbit. In contrast, a spike recovery study showed that aluminum hydroxide interfered with the LAL clot and kinetic assays; however, the LAL clot assay was effective at detecting endotoxin without loss of LAL activity after serial dilution of the samples. Furthermore, there was good correlation in the LAL clot assay between the amount of LPS added and the amount recovered. However, both turbidimetric and chromogenic kinetic assays displayed no correlation between the LPS amount added and recovered. Our results suggest that the LAL clot assay is sensitive and reliable when samples are properly prepared, and can be used to replace the rabbit pyrogen test for the detection of endotoxin in HB vaccines.  相似文献   

5.
Five different intravenous IgG (i.v. IgG) preparations were assessed for their capacity to modify the pyrogenic response to bacterial lipopolysaccharide (LPS) of rabbits under the conditions of a pharmacopoeal test. Four of the five preparations were found to mitigate the reaction rendering the result "non-pyrogenic" with an LPS dose proved pyrogenic when administered in saline or in albumin. Bacterial LPS was found readily detectable by a simple Limulus amoebocyte lysate (LAL) gelation test. Four of six brands of i.v. IgG were found reactive in the test under conditions adjusted to detect the FDA limit. The reaction obtained upon addition of standard LPS to the negative preparations supported the validity of the assay. The LAL reactivity of two of the reactive preparations was inhibited by laminarin, a compound known to inhibit Limulus lysate gelation by beta-D-glucan, but not by Polymyxin B. Specific detection of bacterial endotoxins in i.v. IgG solutions requires inhibition of the beta-D-glucan pathway of the Limulus lysate coagulation. Using an appropriate inhibitor, the LAL gelation test is suitable to detect a potential endotoxin contamination in i.v. IgG which might have not been unravelled by the in vivo test for pyrogens.  相似文献   

6.
The pyrogen test and the endotoxin test (the LAL test) have been playing crucial roles in detecting endotoxin in parenteral drugs. The current test methods, however, have disadvantages such as requiring a large number of animals or an inadequacy in evaluation of in vivo endotoxin activity. We attempted to establish a new assay method that can overcome the shortcomings of the current methods. We standardized the in vitro assay method by the use of prostaglandin E2 (PGE2) induction from peripheral blood of rabbits for detecting endotoxin activity. A linear dose-response regression was attained from approximately 0.15 to 5 endotoxin units/ml of Japanese national reference standard endotoxin by the in vitro assay. The assay showed a fine correlation with the pyrogen test but not with the LAL test, when endotoxins from various bacterial sources were tested. The in vitro assay was also shown to have the capability of detecting a synergistic effect of endotoxin and parenteral drugs. The in vitro PGE2 induction test using rabbit blood was, therefore, suggested to be the appropriate test method for guaranteeing the same level of safety of parenteral drugs as the pyrogen test does.  相似文献   

7.
The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract ofLimulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (labon-a-chip) prototype, 62 mm (L)×18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2 mm (W)×44.3 mm (L)×100 μm(D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip chickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 toca. 4.4 μL. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.  相似文献   

8.
34 children with gastrointestinal diseases of infectious, allergic and mixed etiology were examined. The state of normal microflora in the large intestine as indicated by fecal bacterial charts and the level of secretory immunoglobulin A (sIgA) in the contents of the intestine as indicated by the results of radial immunodiffusion were studied. In addition, the content of endotoxin in the children's plasma was determined with the use of the Limulus (LAL) test. The presence of endotoxin in the plasma of children with intestinal dysbiosis was determined in 71.1% of cases. The frequency of the detection of antigenemia was found to be related to the severity of manifestations of dysbiotic changes in the intestine and to the level of sIgA in fecal supernatants. The inclusion of the probiotic preparation Bifidumbacterin forte containing live bifidobacteria adsorbed on activated charcoal into the complex therapy of digestive tract diseases ensured a decrease in the detection rate of endotoxinemia, which correlated with the tendency towards the normalization of defective intestinal microflora.  相似文献   

9.
显色基质鲎试剂法在人血白蛋白热原检测中的应用   总被引:1,自引:0,他引:1  
为了对显色基质法测定人血白蛋白中的内毒素含量方法进行探讨。以内毒素,鲎试剂及显色基质,在一定的条件下反应释放出对硝基苯胺(PNA),溶液呈现黄色,于波长545nm处比色读数,其产色深浅与内毒素浓度呈线性关系,从而定量测定出检品中内毒素含量。结果表明标准曲线的线性相关系数r≥0.98,人血白蛋白经3.3倍稀释后无干扰作用。显色基质法与家兔法比较,有灵敏、快速、能定量、重复性好的特点,可用于人血白蛋白内毒素含量的测定。  相似文献   

10.
Six limulus amebocyte lysate (LAL) preparations obtained from five different suppliers were evaluated for sensitivity, dependability, cost, convenience of use, and correlation with the United States Pharmacopeial (USP) rabbit pyrogen test method. Endotoxins from various gram-negative microorganisms were used for the evaluation. Major differences among the LAL preparations lie in the area of sensitivity. Differences, up to 100-fold, exist in the sensitivity of the various LAL preparations to the same endotoxin. The LAL tests in general were 3 to 300 times more sensitive than was the USP rabbit pyrogen test method. The LAL and the USP rabbit pyrogen test data correlated well when the endotoxin in a relatively pure and undegraded form was examined. However, large discrepancies in correlation were found when partially degraded endotoxins were compared. One LAL preparation responded to both intact and degraded endotoxin, whereas others responded only to intact endotoxin; the latter closely correlated with the febrile response of the rabbit. Therefore, proper selection of an LAL preparation is important for its application in clinical, pharmaceutical, public health, and environmental areas.  相似文献   

11.
Six limulus amebocyte lysate (LAL) preparations obtained from five different suppliers were evaluated for sensitivity, dependability, cost, convenience of use, and correlation with the United States Pharmacopeial (USP) rabbit pyrogen test method. Endotoxins from various gram-negative microorganisms were used for the evaluation. Major differences among the LAL preparations lie in the area of sensitivity. Differences, up to 100-fold, exist in the sensitivity of the various LAL preparations to the same endotoxin. The LAL tests in general were 3 to 300 times more sensitive than was the USP rabbit pyrogen test method. The LAL and the USP rabbit pyrogen test data correlated well when the endotoxin in a relatively pure and undegraded form was examined. However, large discrepancies in correlation were found when partially degraded endotoxins were compared. One LAL preparation responded to both intact and degraded endotoxin, whereas others responded only to intact endotoxin; the latter closely correlated with the febrile response of the rabbit. Therefore, proper selection of an LAL preparation is important for its application in clinical, pharmaceutical, public health, and environmental areas.  相似文献   

12.
Lipopolysaccharide (LPS), also known as endotoxin, triggers a fatal septic shock; therefore, fast and accurate detection of LPS from a complex milieu is of primary importance. Several LPS affinity binders have been reported so far but few of them have proved their efficacy in developing electrochemical sensors capable of selectively detecting LPS from crude biological liquors. In this study, we identified 10 different single-stranded DNA aptamers showing specific affinity to LPS with dissociation constants (K(d)) in the nanomolar range using a NECEEM-based non-SELEX method. Based on the sequence and secondary structure analysis of the LPS binding aptamers, an aptamer exhibiting the highest affinity to LPS (i.e., B2) was selected to construct an impedance biosensor on a gold surface. The developed electrochemical aptasensor showed excellent sensitivity and specificity in the linear detection range from 0.01 to 1 ng/mL of LPS with significantly reduced detection time compared with the traditional Limulus amoebocyte lysate (LAL) assay.  相似文献   

13.
Li C  Ng ML  Zhu Y  Ho B  Ding JL 《Protein engineering》2003,16(8):629-635
Endotoxin, also known as lipopolysaccharide (LPS), is the major mediator of septic shock due to Gram-negative bacterial infection. Chemically synthesized S3 peptide, derived from Sushi3 domain of Factor C, which is the endotoxin-sensitive serine protease of the limulus coagulation cascade, was previously shown to bind and neutralize LPS activity. For large-scale production of this peptide and to mimick other pathogen-recognizing molecules, tandem multimers of the S3 gene were constructed and expressed in Escherichia coli. The recombinant tetramer of S3 (rS3-4mer) was purified by anion exchange and digested into monomers (rS3-1mer). Both the rS3-4mer and rS3-1mer were functionally analyzed for their ability to bind LPS by an ELISA-based method and surface plasmon resonance. The LAL inhibition and TNFalpha-release test showed that rS3-1 mer can neutralize the LPS activity as effectively as the synthetic S3 peptide, while rS3-4mer displays an enhanced inhibitory effect on LPS-induced activities. Both recombinant peptides exhibited low cytotoxicity and no haemolytic activity on human cells. This evidence suggests that the recombinant sushi peptides have potential use for the detection, removal of endotoxin and/or anti-endotoxin strategies.  相似文献   

14.
Lipopolysaccharide (LPS, i.e. endotoxin) present in meningococcal outer-membrane protein and polysaccharide preparations made for vaccine use was quantitated by a silver-stain method following SDS-PAGE. The reactivities of LPS in the preparations were also measured by rabbit pyrogenicity and Limulus amoebocyte lysate (LAL) assay. Although rabbit pyrogenicity and LAL assay are more sensitive than the silver stain method, the latter provided an actual amount of LPS present in the protein or in the polysaccharide. For a meningococcal protein preparation, rabbit pyrogenicity showed about one-tenth, and even less by LAL assay, of the actual amount of LPS. This is because protein-bound LPS in meningococcal protein preparations is about 10-fold less active in causing fever in rabbits, and 20- to 40-fold less active in the gelation of LAL than the same amount of a purified free LPS which is generally used as a reference in quantitating LPS in these two assays. As for the small amount of LPS present in a meningococcal polysaccharide preparation, similar LPS content was obtained when measured by the three methods suggesting that the LPS is not bound to the polysaccharide in contrast to that in the proteins mentioned above. The purified meningococcal LPS was pyrogenic in rabbits at 1 ng/kg.  相似文献   

15.
The measurement of airborne endotoxins is thus far not standardized. Earlier studies reported higher endotoxin yields when Tween 20 was added to the media used for filter extraction and in the Limulus amebocyte lysate (LAL) assay. This study compared four common media and assessed the effects of Tween during extraction and analysis separately. Parallel airborne dust samples from five work environments (n = 250) were used to compare the four media (pyrogen-free water [PFW], PFW-Tween 20, PFW-Tris, and PFW-triethylamine-phosphate [TAP]) and an extraction time of 10 or 60 min. A subset of the extracts in PFW or PFW-Tween (n = 40) were analyzed in parallel LAL assays with PFW or PFW-Tween as the assay medium. The results produced by a shorter extraction time or the presence of Tris were similar to the results for the reference procedure (PFW and 60 min of shaking). The use of PFW-TAP showed overall lower yields and a deviant calibration curve. The presence of Tween in the extraction medium resulted in significantly (P < 0.05) higher endotoxin yields from all dust types, independent of the effect of Tween in the assay. Tween in the LAL assay, however, also strongly inhibited the reactivity of the lipopolysaccharide (LPS) standard, thus shifting the calibration curve to higher values. The inhibition of LPS in test samples was less pronounced and varied between dust sources, resulting in enhanced calculated concentrations. This assay effect could be circumvented by diluting extracts at least 50-fold before the LAL assay. In conclusion, of the media tested, only Tween enhances the efficiency of endotoxin extraction from airborne dust samples in a consistent manner. We recommend extraction in PFW-Tween combined with dilution and LAL analysis in PFW.  相似文献   

16.
人用狂犬病疫苗浓缩前后内毒素含量变化的研究   总被引:1,自引:0,他引:1  
本文采用显色鲎试验法测定人用狂犬病疫苗浓缩前后半成品中内毒素含量。经鲎试验抑制增强实验确定人用狂犬病疫苗半成品对鲎试验法测定内毒素无干扰作用。样品经系列稀释,测定光吸收值(545nm),然后将其对数回归直线与标准品的反应直线比较,结果表明,两者间有平行关系,经对四个生物制品研究所的样品进行测定,结果显示,人用狂犬病疫苗经超滤浓缩后内毒素含量有所增加,但在被检31批样品中,除一所二批浓苗外,其余29批均低于以往测得的最低家兔致热剂量(3.32EU/ml/Kg)。  相似文献   

17.
The involvement of intestinal flora endotoxin (ET) in the regulation of immune homeostasis, namely, the maintenance of the physiological tone of all components of the immune system (so-called systemic endotoxinemia, SEE) is postulated. Excessive endotoxin in the systemic blood flow under conditions of the failure of endotoxin-binding and endotoxin-eliminating systems results in another phenomenon, endotoxin aggression (EA), which is regarded as a common factor of pathogenesis of various human diseases. An important role of endotoxin insufficiency in the development of immunodeficiencies is hypothesized.  相似文献   

18.
This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm × 6 mm × 28 μm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude–time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel–clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.  相似文献   

19.
Pyrogenic substances in influenza HA (IHA) vaccine have been controlled by the pyrogen test or the mouse body weight decreasing toxicity (BWD) test. We examined the possibility of replacing the animal tests with the endotoxin test Commercial IHA vaccines were found to show considerable levels of LAL activity ranging from 0.2 to 160 EU/ml. However, a batch of the vaccine having even 100 EU/ml of LAL activity showed neither pyrogenicity in rabbits nor tumor necrosis factor alpha (TNF-alpha) induction in RAW264.7 cells. The LAL activity of IHA vaccine was abolished by a monoclonal antibody that recognizes LPS-binding epitope of LAL factor C. The activity of IHA vaccine showed different physicochemical properties from those of LAL activity of endotoxin. LAL activity of endotoxin is known to be sensitive to polymyxin B treatment and was found to be resistant to polyoxyethylene 10 cetyl ether (Brij56) treatment. On the contrary, the LAL activity of IRA vaccine was shown to be resistant to polymyxin B but sensitive to Brij56 treatment. The difference in sensitivity of the two LAL activities to polymyxin B and Brij56 might suggest the possibility of their discriminative measurements.  相似文献   

20.
Abstract

LPS (lipopolysaccharides) represent a feared pyrogenic impurity in parenterals and raw materials used for their production. In liposome dispersions detection of LPS via the standard Limulus amoebocyte lysate (LAL) test was proved unreliable in presence of phospholipids (liposomes). Attempts were made either to eliminate or inactivate disturbances of the LAL test by phospholipid(s). Common methods to overcome inhibition of the test, such as dilution of the sample, removal of the inhibiting substance by centrifugation or its inactivation by addition of detergents, were found not successful when LPS was present in liposome membrane-bound form. Another means to remove inhibiting substances is ultrafiltration. Ultrafiltration of aqueous lipid dispersions cannot be performed due to clogging of the filter membrane. Ultrafiltration upon addition of organic solvents turned out to be difficult due to the very limited resistance of celluloseacetate filter membranes against these solvents. Nevertheless a test protocol for detection of lipopolysaccharides in phospholipids and liposomes could be worked out and validated. It comprises dissolution of the phospholipid or liposomesNin pyrogen-free ethanol/water mixtures, ultrafiltration through pyrogen-free Ultrasart D20 units (Sartorius AG, Gottingen), reconstitution of the residue in pyrogen-free water or buffer and LAL testing. This procedure has been shown to allow for quantitative detection of LPS from minute amounts of 0.5 EU/ml up to very high amounts of 1000 EU/ml in liposomes in a reliable and reproducible manner. Recovery of LPS in all cases was fairly high i.e. one to two dilution steps below the theoretical LPS content.  相似文献   