首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
多重PCR技术在病原检测中的应用   总被引:14,自引:0,他引:14  
多重PCR能够同时扩增不同片段,具有普通PCR方法不可比拟的优势。简要论述了多重PCR在细菌病原体的检测、病毒病原体的检测、支原体和衣原体及寄生虫的检测、微生物耐药性检测等方面的应用,分析了多重PCR的影响因素及条件优化,并进一步综述了多重PCR的应用前景。  相似文献   

2.

Background

The CombiMatrix ElectraSense® microarray is a highly multiplex, complementary metal oxide semiconductor with 12,544 electrodes that are individually addressable. This platform is commercially available as a custom DNA microarray; and, in this configuration, it has also been used to tether antibodies (Abs) specifically on electrodes using complementary DNA sequences conjugated to the Abs.

Methodology/Principal Findings

An empirical method is described for developing and optimizing immunoassays on the CombiMatrix ElectraSense® microarray based upon targeted deposition of polypyrrole (Ppy) and capture Ab. This process was automated using instrumentation that can selectively apply a potential or current to individual electrodes and also measure current generated at the electrodes by an enzyme-enhanced electrochemical (ECD) reaction. By designating groups of electrodes on the array for different Ppy deposition conditions, we determined that the sensitivity and specificity of a sandwich immunoassay for staphylococcal enterotoxin B (SEB) is influenced by the application of different voltages or currents and the application time. The sandwich immunoassay used a capture Ab adsorbed to the Ppy and a reporter Ab labeled for fluorescence detection or ECD, and results from these methods of detection were different.

Conclusions/Significance

Using Ppy deposition conditions for optimum results, the lower limit of detection for SEB using the ECD assay was between 0.003 and 0.01 pg/ml, which represents an order of magnitude improvement over a conventional enzyme-linked immunosorbant assay. In the absence of understanding the variables and complexities that affect assay performance, this highly multiplexed electrode array provided a rapid, high throughput, and empirical approach for developing a sensitive immunoassay.  相似文献   

3.
Detection of Microbial Pathogens in Shellfish with Multiplex PCR   总被引:16,自引:0,他引:16  
Multiplex PCR amplification of uidA, cth, invA, ctx, and tl genes was developed enabling simultaneous detection in shellfish of Escherichia coli, an indicator of fecal contamination and microbial pathogens, Salmonella typhimurium, Vibrio vulnificus, V. cholerae, and V. parahaemolyticus, respectively. Each of the five pairs of oligonucleotide primers was found to support PCR amplifications of only its targeted gene. The optimized multiplex PCR reaction utilized a PCR reaction buffer containing 2.5 mM MgCl2 and primer annealing temperature of 55°C. Oyster tissue homogenate seeded with these microbial pathogens was subjected to DNA purification by the Chelex™ 100 (BioRad) method. The sensitivity of detection for each of the microbial pathogens was ≤101–102 cells following a “double” multiplex PCR amplification approach. Amplified target genes in a multiplex PCR reaction were subjected to a colorimetric GeneComb™ (BioRad) DNA-DNA hybridization assay. This assay was rapid and showed sensitivity of detection comparable to the agarose gel electrophoresis method. The colorimetric GeneComb™ assay avoids use of hazardous materials inherent in conventional gel electrophoresis and radioactive-based hybridization methods. Multiplex PCR amplification, followed by colorimetric GeneComb™ DNA-DNA hybridization, has been shown to be an effective, sensitive, and rapid method to detect microbial pathogens in shellfish. Received: 17 November 1997 / Accepted: 17 February 1998  相似文献   

4.
食源性致病菌多重分子生物学检测技术研究进展   总被引:1,自引:1,他引:1  
快速、可靠的食源性致病菌高通量检测方法对于确保食品安全具有重要意义,近年基于DNA水平的多重分子生物学检测技术迅速发展,针对各种不同的食源性致病菌建立了多种多重分子检测技术,包括多重PCR、多重实时荧光PCR以及基因芯片等。对这些多重分子检测技术的最新研究进展作一综述,并且建议在今后该技术的研究中,仍需要在食品中多种致病菌同时选择性增菌培养、亚致死损伤修复以及检测内标的构建等方面取得突破,从而能够更好地实现食源性致病菌的高通量检测。  相似文献   

5.

Background

Pneumonia is a common disease that is a leading cause of mortality worldwide and frequently requires hospital admission. A large number of infectious agents may be involved and as a result of the potential severity of the infection, a clear and quick diagnostic is mandatory in order to take the appropriate decision for the health of the patient. However, a real gap exists between the multiplicity of information required by the practitioner and the diagnostic tools available.

Methods

After the selection of the multiple gene targets (bacterial viral and resistance gene) to be detected by the HIFI Resp product, the PCR conditions for each target have been defined individually and then in the multiplex PCR format.The multiplex detection assay is performed and specific hybridization events appear on the bottom of the chip. The software (AXOware) automatically process the data and interpreted the results into an efficient and clear medical report that can be directly used by clinicians.

Results

Within the 23 targets that are implemented on the microarray, 14 are actually specifically detectable by HIFI Resp technology (mp, UL30, npA, sa442, algD, mip, mecA, NDM, IMP, VIM, OXA-23, OXA-48, β-globin and G3PDH). Six bacterial targets (mecC, fucK, KPC, nuc, cpsA and lytA) and three viral target (npB, neur and UL83) have not yet been identified or not in a totally reproducible way. These later are under improvement process. The technology developed allows the detection and characterization of multiple pathogen potentially present in a respiratory sample.

Conclusion

The HIFI Resp product based on a sample-to-result syndromic approach, with a minimum user intervention during the procedure on a cost efficient automated platform and a short time of analysis is a promising device.  相似文献   

6.
7.
食源性致病菌多重PCR快速检测方法建立与应用   总被引:2,自引:0,他引:2  
利用PCR技术,建立多组多重食源性致病菌PCR快速检测方法。设计受试菌特异性引物,反应体系中加入多对引物和多种DNA模板,采用正交试验优化PCR反应条件,进行特异性引物的PCR扩增。建立了多组多重食源性致病菌PCR快速检测方法,方法中所检测受试菌株和模拟样品均出现特异性扩增条带,结果与实际相符。所建立多组多重PCR快速检测体系符合设计要求,可以应用于食源性突发公共卫生事件的应急检测和日常样品检测工作。  相似文献   

8.
A multiplex PCR-based method was designed for the simultaneous detection of the main pathogens involved in warm-water streptococcosis in fish (Streptococcus iniae, Streptococcus difficilis, Streptococcus parauberis, and Lactococcus garvieae). Each of the four pairs of oligonucleotide primers exclusively amplified the targeted gene of the specific microorganism. The sensitivity of the multiplex PCR using purified DNA was 25 pg for S. iniae, 12.5 pg for S. difficilis, 50 pg for S. parauberis, and 30 pg for L. garvieae. The multiplex PCR assay was useful for the specific detection of the four species of bacteria not only in pure culture but also in inoculated fish tissue homogenates and naturally infected fish. Therefore, this method could be a useful alternative to the culture-based method for the routine diagnosis of warm-water streptococcal infections in fish.  相似文献   

9.
目的:建立HBV基因分型高通量液相芯片检测技术,并探讨其应用价值.方法:对GenBank中收录的明确分型的HBV基因序列进行分析,选择preS2-S区设计引物和A、B、C和D型特异性探针.与荧光编码微球偶联的特异型探针与一条引物生物素标记的PCR产物直接杂交反应,然后结合亲和素标记的藻红蛋白,用流式检测仪(Bio-Plex 200)检测荧光信号.检测182份阳性乙肝患者血清DNA,其中35份样品检测结果与测序法比较.用B、C型质粒DNA倍比稀释及混合样品检测灵敏度来评估该方法.结果:建立了HBV基因分型的快速高通量液相芯片检测方法.182份患者血清检测结果为:B型占24.2% (44/182),C型占71.4%(130/182),D型为6.6 %(12/182),BC混合型4.4%(8/182).其中35份样本与测序法比较,除3份混合型测序法未检出外,其它32例结果均相同本方法的灵敏度检测下线为1×103 copies/mL.结论:应用悬液芯片技术进行乙肝病毒的基因分型分析,具有较好的特异性和较高的灵敏度,并有简便、灵活和高通量等优势.该检测系统不仅在科研中有广泛的前景,也有望成为临床推广的多重分子诊断和基因分型的新方法.  相似文献   

10.
Size selection via filtration offers an antigen-independent approach for the enrichment of rare cell populations in blood of cancer patients. We evaluated the performance of a novel approach for multiplex rare cell detection in blood samples from metastatic breast (n = 19) and lung cancer patients (n = 21), and healthy controls (n = 30) using an automated microfluidic filtration and multiplex immunoassay strategy. Captured cells were enumerated after sequential staining for specific markers to identify circulating tumor cells (CTCs), circulating mesenchymal cells (CMCs), putative circulating stem cells (CSCs), and circulating endothelial cells (CECs). Preclinical validation experiments using cancer cells spiked into healthy blood demonstrated high recovery rate (mean = 85%) and reproducibility of the assay. In clinical studies, CTCs and CMCs were detected in 35% and 58% of cancer patients, respectively, and were largely absent from healthy controls (3%, p = 0.001). Mean levels of CTCs were significantly higher in breast than in lung cancer patients (p = 0.03). Fifty-three percent (53%) of cancer patients harbored putative CSCs, while none were detectable in healthy controls (p<0.0001). In contrast, CECs were observed in both cancer and control groups. Direct comparison of CellSearch® vs. our microfluidic filter method revealed moderate correlation (R2 = 0.46, kappa = 0.47). Serial blood analysis in breast cancer patients demonstrated the feasibility of monitoring circulating rare cell populations over time. Simultaneous assessment of CTCs, CMCs, CSCs and CECs may provide new tools to study mechanisms of disease progression and treatment response/resistance.  相似文献   

11.
Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac), watermelon silver mottle virus (WSMoV), and melon yellow spot virus (MYSV) screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5–10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.  相似文献   

12.
多重PCR检测无公害畜禽肉和水产品中4种致病菌   总被引:16,自引:0,他引:16  
建立无公害畜禽肉和水产品中肠出血性大肠杆菌(EHEC)、沙门氏菌、副溶血性弧菌(VP)和单核细胞增生性李斯特氏菌(LM)的多重PCR检测方法,为这些致病菌的快速诊断提供实验依据。选择分别针对EHEC溶血素基因hlyAB、副溶血性弧菌属保守序列toxR基因、沙门氏菌侵袭基因invA和LM的iap基因特异的4对引物,先分别进行单重PCR扩增,再同时加入4对引物进行多重PCR扩增,扩增产物经测序验证。建立的多重PCR方法可简便、快速、灵敏地实现对EHEC、LM、沙门氏菌和VP的同时检测,在畜禽肉和水产品中的检测灵敏度达到10^3cfu/mL。  相似文献   

13.
14.
Colorimetric aptasensors using unmodified gold nanoparticles (AuNPs) have attracted much attention because of their low cost, simplicity, and practicality, and they have been developed for various targets in the past several years. However, previous research has focused on developing single-target assays. Here, we report the development of a homogeneous multiplex aptasensor by using more than one class of aptamers to stabilize AuNPs. Using sulfadimethoxine (SDM), kanamycin (KAN) and adenosine (ADE) as example targets, a KAN aptamer (750 nM), an SDM aptamer (250 nM) and an ADE aptamer (500 nM) were mixed at a 1∶1∶1 volume ratio and adsorbed directly onto the surface of unmodified AuNPs by electrostatic interaction. Upon the addition of any of the three targets, the conformation of the corresponding aptamer changed from a random coil structure to a rigid folded structure, which could not adsorb and stabilize AuNPs. The AuNPs aggregated in a specific reaction buffer (20 mM Tris-HCl containing 20 mM NaCl and 5 mM KCl), which led to a color change from red to purple/blue. These results demonstrate that the multiplex colorimetric aptasensor detected three targets simultaneously while maintaining the same sensitivity as a single-target aptasensor for each individual target. The multiplex aptasensor could be extended to other aptamers for various molecular detection events. Due to its simple design, easy operation, fast response, cost effectiveness and lack of need for sophisticated instrumentation, the proposed strategy provides a powerful tool to examine large numbers of samples to screen for a small number of potentially positive samples containing more than one analyte, which can be further validated using sophisticated instruments.  相似文献   

15.
16.
Immunopathogenesis studies employing West Nile virus (WNV) mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA) are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI) and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA) for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI) serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.  相似文献   

17.
病原体的存在,尤其是食品中的病原体,给人类健康带来了威胁。DNA芯片技术是一种非常有效的病原体检测工具,具有众多传统检测方法所不具备的优势,受到广泛关注。我们简要论述了DNA芯片在细菌病原体、寄生虫、病毒病原体、微生物耐药性等的检测中的应用,并进一步综述了DNA芯片技术在食品检测中存在的问题、解决方法及发展方向。  相似文献   

18.

Background

Chagas disease is due to the parasite Trypanosoma cruzi, a protist disseminated by a Triatome vector. This disease is endemic to Latin America and considered by WHO as one of the 17 world’s neglected diseases. In Europe and in North America, imported cases are also detected, due to migration of population outside of the endemic region. Diagnosis of T. cruzi infection is usually made indirectly by the detection of specific antibodies to T. cruzi antigens. Following initial diagnostic evaluation or screening test (qualifying or discarding blood donation), a confirmation test is performed for samples initially reactive. The test presented in this study aims at the confirmation/refutation of the infectious status of human blood samples and will permit taking appropriate clinical measures.

Methodology/Principal Findings

We designed a novel array of twelve antigens and printed these antigens onto 96-well plates. We tested 248 positive samples T. cruzi, 94 unscreened blood donors’ samples from non-endemic area, 49 seronegative blood donors, 7 false-positive and 3 doubtful samples. The observed reactivities were analyzed to propose a decision-tree algorithm that correctly classifies all the samples, with the potential to discriminate false-positive results and sticky samples. We observed that antibodies levels (Sum of all antigens) was significantly higher for PCR positive than for PCR negative samples in all studied groups with Multi-cruzi.

Conclusion/Significance

The results described in this study indicate that the Multi-cruzi improves the serological confirmation of Chagas disease. Moreover the “sum of all antigens” detected by Multi-cruzi could reflect parasitemia level in patients–like PCR signals does—and could serve as an indicator of parasite clearance in longitudinal follow-ups. Validation of this assay is still required on an independent large collection of well characterized samples including typical false-reactive samples such as Leishmaniasis.  相似文献   

19.
Efficient and reliable diagnostic tools for the routine indexing and certification of clean propagating material are essential for the management of pospiviroid diseases in horticultural crops. This study describes the development of a true multiplexed diagnostic method for the detection and identification of all nine currently recognized pospiviroid species in one assay using Luminex bead-based suspension array technology. In addition, a new data-driven, statistical method is presented for establishing thresholds for positivity for individual assays within multiplexed arrays. When applied to the multiplexed array data generated in this study, the new method was shown to have better control of false positives and false negative results than two other commonly used approaches for setting thresholds. The 11-plex Luminex MagPlex-TAG pospiviroid array described here has a unique hierarchical assay design, incorporating a near-universal assay in addition to nine species-specific assays, and a co-amplified plant internal control assay for quality assurance purposes. All assays of the multiplexed array were shown to be 100% specific, sensitive and reproducible. The multiplexed array described herein is robust, easy to use, displays unambiguous results and has strong potential for use in routine pospiviroid indexing to improve disease management strategies.  相似文献   

20.
Screening large numbers of target regions in multiple DNA samples for sequence variation is an important application of next-generation sequencing but an efficient method to enrich the samples in parallel has yet to be reported. We describe an advanced method that combines DNA samples using indexes or barcodes prior to target enrichment to facilitate this type of experiment. Sequencing libraries for multiple individual DNA samples, each incorporating a unique 6-bp index, are combined in equal quantities, enriched using a single in-solution target enrichment assay and sequenced in a single reaction. Sequence reads are parsed based on the index, allowing sequence analysis of individual samples. We show that the use of indexed samples does not impact on the efficiency of the enrichment reaction. For three- and nine-indexed HapMap DNA samples, the method was found to be highly accurate for SNP identification. Even with sequence coverage as low as 8x, 99% of sequence SNP calls were concordant with known genotypes. Within a single experiment, this method can sequence the exonic regions of hundreds of genes in tens of samples for sequence and structural variation using as little as 1 μg of input DNA per sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号