首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A magnetic solid phase enzyme-linked immunosorbent assay (MELISA) for quantification of IgG antibodies to somatic and metabolic antigens of Paracoccidioides brasiliensis was developed. Activation of magnetic polyacrylamide agarose beads with concanavalin A was superior to glutaraldehyde activation, and test sensitivity was higher for somatic than for metabolic antigens. Comparative MELISA, counterimmunoelectrophoresis and erythroimmunoassay tests with sera from 33 proven cases of paracoccidioidomycosis, 14 cases of histoplasmosis and 20 normal human sera showed the MELISA could distinguish antibody levels in paracoccidioidomycosis from those in normal sera; however two sera from histoplasmosis cases cross-reacted in the MELISA. MELISA is a rapid test (5-6 h) and the results suggest it has considerable potential value for assay of anti-P. brasiliensis antibodies.  相似文献   

2.
To establish a sensitive and specific antibody assay, potent antigenic proteins encoded by human herpesvirus 8 (HHV8) were studied. Fifteen recombinant HHV8-encoded proteins were produced as glutathione S-transferase fusion proteins. The sera from AIDS-associated Kaposi's sarcoma (KS) patients reacted with four proteins encoded by open reading frames (ORFs) K8.1, 59, 65, and 73 in a Western blot assay. An enzyme-linked immunosorbent assay (ELISA) using these four proteins as antigens (mixed-antigen ELISA) revealed that all 26 sera derived from KS patients (24 with and 2 without human immunodeficiency virus infection) became positive for anti-HHV8 antibodies. The presence of HHV8 was demonstrated in 14 (1. 4%) of 1,004 sera from the Japanese general population and 10 (1.9%) of 527 sera from patients without HHV8-associated diseases. The presence of immunoglobulin G (IgG) and IgM antibodies against HHV8 examined further by the mixed-antigen ELISA and Western blotting revealed IgG antibody in all ELISA-positive sera, while IgM antibody against ORF K8.1 was absent. These data suggest that the ORF 73 and 65 proteins are potent antigens for a sensitive serological assay.  相似文献   

3.
Wang X  Ren L  Tu Q  Wang J  Zhang Y  Li M  Liu R  Wang J 《Biosensors & bioelectronics》2011,26(7):3353-3360
Rabies, canine distemper, and canine parvovirus are common contagious viral diseases of dogs and many other carnivores, and pose a severe threat to the population dynamics of wild carnivores, as well as endangering carnivore conservation. However, clinical diagnosis of these diseases, especially canine distemper and canine parvovirus, is difficult because of the broad spectrum of symptoms that may be confused with other respiratory and enteric diseases of dogs. The most frequently used and proven techniques for diagnosing viral diseases include the conventional enzyme-linked immunosorbent assay (ELISA), rapid fluorescent focus inhibition test (RFFIT), mouse neutralisation test (MNT), and fluorescent antibody virus neutralization (FAVN) test. However, these methods still have some inherent limitations. In this study, a magnetic protein microbead-aided indirect fluoroimmunoassay was developed to detect canine virus specific antibodies, human rabies immunoglobulin, CDV McAbs, and CPV McAbs. In this assay, an avidin-biotin system was employed to combine magnetic microbeads and virus antigens (rabies virus, canine distemper virus, and canine parvovirus). Quantification of the targeted virus antibodies was analyzed through indirect fluoroimmunoassay using the specific antigen-antibody reaction, as well as their corresponding FITC-labeled detection antibodies (mouse anti-human IgG/FITC conjugate or rabbit anti-dog IgG/FITC conjugate). The results indicated that the fluorescence intensity increased when a higher concentration of the targeted analyte was used, but the control had almost no fluorescence, much like the conventional ELISA. For human rabies immunoglobulin, CDV McAbs, and CPV McAbs, the minimum detectable concentrations were 0.2 IU/mL, 0.3 ng/mL, and 0.5 ng/mL, respectively. All of these results indicate that this assay can be employed to determine the presence of canine virus specific antibodies. In addition, the method devised here can be utilized as a general protocol in other bacterial and viral marker analysis.  相似文献   

4.
Summary An IgG monoclonal antibody against recombinant human granulocyte-macrophage colony-stimulating factor (GM-CSF), designated HGMI, was produced by fusion of immune mouse splenocytes with HAT-sensitive murine myeloma cells. A sandwich enzyme-linked immunosorbent assay (ELISA) for measurement of human GM-CSF was developed using this HGMI and a polyclonal antibody against GM-CSF raised in a rabbit. GM-CSF in culture supernatants of phytohemagglutinin (PHA)- or concanavalin A (Con A)-stimulated peripheral blood mononuclear cells (PBMC) were measured by this ELISA system and the conventional CFU-GM colony formation method. The data indicated that the ELISA was highly efficient and sensitive for the detection of as little as 50 pg/ml recombinant GM-CSF. The CFU-GM colony assay may be influenced by other cytokines which can enhance or suppress colony formation, and ELISA for GM-CSF is more useful for kinetic studies of precise levels of production from PBMC.  相似文献   

5.
This paper describes the isolation and characterization of a monoclonal antibody to bovine liver glutamate dehydrogenase (GDH). Monoclonal antibody is mouse immunoglobulin subclass IgG2a and reacts strongly with the antigen in an enzyme-linked immunosorbent assay (ELISA). Its specificity was determined by an antigen binding assay and by Western blotting. Potential uses and possible applications are discussed.  相似文献   

6.
A double ligand enzyme-linked immunosorbent assay (ELISA) has been developed to detect antibodies against brain tissue antigens in the sera of patients with neurological diseases. The sera were tested on human white matter homogenate. The technique consists of successive incubations with the human serum to be tested, rabbit immunoglobulin G (IgG) to human immunoglobulins (Ig), alkaline phosphate-labeled protein A and alkaline phosphatase substrate. This procedure has the advantage of increased sensitivity compared to the classical ELISA. Application of this procedure to the sera of patients with neurological diseases showed that the unspecific binding is very low and the results are reliable. Moreover the test allows the detection of antibodies to chemically different antigenic structures that can occur in a variety of neurological diseases.  相似文献   

7.
A group of 251 children aged 2-3 years given live attenuated mumps virus vaccine PAVIVAC of Czechoslovak production were tested for antiparotitis antibody levels in pre- and postvaccination sera by neutralization test (NT), enzyme-linked immunosorbent assay (ELISA) and sensitive hemagglutination inhibition test, enhanced by heterologous antibody to human immunoglobulin G (E-HIT). The prevaccination findings were as follows: positive ELISA IgG titres, neutralization antibodies and hemagglutination inhibition antibodies were present in, respectively, 35%, 25.9% and 27.9% of the sera. Postvaccination seroconversions were evaluated in 159 susceptible vaccinees whose prevaccination sera had been negative by all three tests. The lowest seroconversion was detected by NT (74.2%), seroconversions by ELISA and E-HIT were appreciably higher (82.4% and 86.8%, respectively). The seven children showing a seroconversion by E-HIT but not by ELISA had a 4 fold increase of anti-mumps ELISA IgG antibodies as well, but the rise of antibody titres was at a level falling in the range below the positivity criterion for ELISA. The statistically evaluated detection rate for antibodies was significantly higher (significance test "t") by ELISA as compared with neutralization test. However, antibody levels (geometric mean titres) were 8-10 times lower in postvaccination sera than in convalescent sera of 30 children with mumps in all three tests.  相似文献   

8.
Conventional methods, such as gastric biopsy, enzyme-linked immunosorbent assay (ELISA), culture, require a long time for the determination of Helicobacter pylori infections. This study reports an amperometric immunoreactor for rapid and sensitive quantification of human serum immunoglobulin G (IgG) antibodies to H. pylori. Antibodies in the serum sample are allowed to react immunologically with the purified H. pylori antigens that are immobilized on a rotating disk. The bound antibodies are quantified by horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to human IgG. HRP in the presence of hydrogen peroxide catalyzes the oxidation of hydroquinone to p-benzoquinone. The electrochemical reduction back to hydroquinone is detected on a glassy carbon electrode surface at -0.15 V. The electrochemical detection can be done within 1 min, and the analysis time does not exceed 30 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.6 and 1.9 U ml-1, respectively. The amperometric immunoreactors showed higher sensitivity and lower time consumed than did the standard spectrophotometric detection ELISA method. It can also be used for rapid analysis in conventional and field conditions in biological, physiological, and analytical practices.  相似文献   

9.
We describe an indirect enzyme-linked immunosorbent assay (ELISA) that utilizes anticanine immunoglobulin for the measurement of rabies-specific antibody in the sera of the major domestic and wildlife reservoirs of rabies in North America. Sufficient cross-reactivity was found to exist between anticanine IgG and serum antibody from all carnivores tested, including dogs, cats, foxes (Vulpes vulpes), skunks (Mephitis sp.) and raccoons (Procyon lotor). With sera of most species, good correlation was observed between results obtained with the ELISA and with the fluorescence inhibition microtest (FIMT). Some wildlife specimens, particularly of skunk and raccoon origin, were cytotoxic in the FIMT, resulting in possible false-positive reactions. In view of this, and since the ELISA is rapid, economical and reproducible (coefficient of variation less than 13%), we consider it to be a favorable alternative to the fluorescence inhibition test for assay of wildlife sera.  相似文献   

10.
Choline acetyltransferase (ChAT) from porcine brain was purified by immunoaffinity chromatography, and the highly purified enzyme was subsequently used for immunization of mice and rabbits. After fusion of mouse spleen cells, 32 cultures producing monoclonal antibodies directed against ChAT were detected by an enzyme-linked immunosorbent assay (ELISA) with immunoaffinity-purified ChAT. Of these original 32, the most active 11 cultures were cloned and used for ascites production. The 11 clones generated monoclonal antibodies of the immunoglobulin (Ig) M class (three), the IgG1 subclass (seven), and the IgG2b subclass (one). The isoelectric points of the antibodies of the IgG class were different in each case. The monoclonal antibodies exhibited different binding characteristics in the above ELISA and on western blots. Two monoclonal antibodies demonstrated excellent immunohistological results with neurons of rat brain and spinal cord. One of them reacted well immunohistochemically with neurons of human brain and also recognized partially purified human placenta ChAT in the ELISA.  相似文献   

11.
We report the assessment and validation of an NS1 epitope-blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to West Nile virus (WNV) in macaques. Sera from naturally infected Macaca nemestrina were tested by ELISA and plaque reduction neutralization test (PRNT). Results were correlated with hemagglutination inhibition (HAI) data. Our results demonstrate that the blocking ELISA rapidly and specifically detects WNV infection in M. nemestrina. In addition, the diagnostic value of 7 commercially available immunoassays (PanBio immunoglobulin [Ig] M ELISA, PanBio IgG ELISA, PanBio immunofluorescence assay (IFA), InBios IgG ELISA, InBios IgM ELISA, Focus Diagnostics IgG ELISA, and Focus Diagnostics IgM ELISA) in M. nemestrina was evaluated and compared with that of the epitope-blocking ELISA. The PanBio IgG ELISA was found to effectively diagnose WNV exposure in M. nemestrina. Further, PanBio IFA slides are fast and reliable screening tools for diagnosing flaviviral exposure in M. nemestrina.  相似文献   

12.
An enzyme-linked immunosorbent assay (ELISA) using antigenic beta-galactosidase-Dirofilaria immitis recombinant fusion protein (FP) obtained by the recombinant DNA technique provided a useful diagnostic tool for human dirofilariasis. D. immitis-infected human sera reacted strongly with FP that was immobilized with anti-beta-galactosidase monoclonal antibody on microplates. However, the FP did not react with sera from patients with other filariasis. In detection of anti-D. immitis IgG antibody. ELISA using FP was highly sensitive and specific compared to that using crude somatic antigen.  相似文献   

13.
The aim of the present work was to make amperometric immunosensors based on the principle of enzyme-linked immunosorbent assay (ELISA). For this purpose, screen-printed electrodes (SPEs) were fabricated using various carbon inks (commercially available inks Gwent, Acheson, Eltecks and two homemade inks PSG & PVCG) to determine the best ink in realizing immunosensors. Amperometric immunosensors made by different carbon inks were compared with standard ELISA in terms of total assay time, amount of biological materials used and sensitivity of detection. A model system containing rabbit anti-mouse immunoglobulin G (RαMIgG) as the capturing antibody, mouse IgG (MIgG) as antigen and alkaline phosphatase conjugated RαMIgG as revealing antibody was used. In these studies, 1-naphthyl phosphate was used as substrate. The experiments done include electrochemical characterization of electrodes, optimization of dilutions of antibodies, immobilization of antibody on the electrode were carried out. The minimum detection limit for the best results of MIgG determination were obtained on screen-printed electrode made by Gwent carbon ink and PSG carbon ink, with a detection limit of 1.0 and 2.0 ng/ml respectively. The time required for detection of mouse IgG was 40 min for SPEs. By using the conventional spectrophotometric method (ELISA method), the minimum detection limit for the MIgG (antigen) detection was 50 ng/ml and the time required for analysis was found to be 140 min.  相似文献   

14.
Qiu C  Kumar S  Guo J  Yu L  Guo W  Shi S  Russo JJ  Ju J 《Analytical biochemistry》2012,427(2):193-201
Knowledge of the anti-drug antibody (ADA) status is necessary in early research studies. Because specific assay materials are sparse and time is pressing, a generic assay format with drug tolerance for detection of ADAs in serum samples from mice exposed to immunoglobulin G (IgG) or antigen-binding fragments (Fabs) is highly desirable. This article describes a generic immune complex assay in the sandwich enzyme-linked immunosorbent assay (ELISA) format based on (i) transformation of free ADAs to immune complexes by preincubation with excess drug, (ii) the use of a murine anti-human Fab constant domain Fab as capture reagent, (iii) detection of the immune complexes by a peroxidase-labeled rabbit anti-murine Fc antibody, and (iv) ADA-positive control conjugates consisting of human Fab and murine IgG. Results of the experiments suggest that the generic immune complex assay for mouse serum samples was at least equivalent to specific ADA immune assays and even superior regarding drug tolerance. The generic immune complex assay confers versatility as it detects ADAs in complex with full-length IgG as well as with Fabs independent of the target specificity in mouse serum samples. These features help to save the sparse amounts of specific antibodies available in early research and development and speed up drug candidate selection.  相似文献   

15.
Autoantibodies to tissue kallikrein (EC 3.4.21.35) were discovered in normal human, rat, mouse, and guinea pig sera. Three independent methods--binding of iodolabeled antigen, enzyme-linked immunosorbent assay (ELISA), and immunoblotting--were used to demonstrate these kallikrein autoantibodies. Autoantibodies from rat and human sera were purified, using rat and human tissue kallikrein-affinity chromatography, respectively. Purified rat kallikrein autoantibody bound 50% of 125I-labeled rat urinary kallikrein upon incubation of antibody at 2.5 X 10(-10) M. The subtypes of rat and human kallikrein autoantibodies were determined by an ELISA, using antisera to immunoglobulin subclasses. In both species, autoantibody was predominantly IgG (approximately 80%) and some IgM (approximately 20%). Purified autoantibodies from rat and human sera were separated on sodium deodecyl sulfate-polyacrylamide gels, and their subunits were identified by Western blot analyses, using anti-rat and anti-human IgG antibodies, respectively. When primary cultures of mouse spleen cells were incubated for 1 to 5 days with lipopolysaccharide (1 to 5 micrograms/ml), the anti-kallikrein antibodies in the media increased up to seven-fold. We have demonstrated circulating autoantibodies that recognize and bind both autologous and heterologous kallikrein; however, their significance to the function of the tissue kallikrein-kinin system in normal and disease states remains to be explored.  相似文献   

16.
A monoclonal mouse anti-human IgG was used to develop an enzyme-linked immunosorbent assay (ELISA) for the measurement of Dermatophagoides pteronyssinus (DP)-specific IgG in human sera. This monoclonal antibody (HG2-25) binds to all subclasses of IgG but not to IgA, IgM, or IgE. For the assay, the DP antigen is coated firmly on polystyrene beads through physical adsorption and any leakable antigen is washed off. The assay gives satisfactory reproducibility and parallelism of the dilution curves. Using 0.1% human serum albumin as a substitute for the DP-specific IgG preabsorbed diluent gave extremely low backgrounds and high sensitivity. Horseradish peroxidase-labeled HG2-25 prepared with the optimum degree of conjugation and free of polymerized conjugates gave responses fairly proportional to the doses. This ELISA gives a satisfactory recovery and is not affected by nonspecific IgG levels in human sera.  相似文献   

17.
Sera collected from a Japanese population over 4 years at yearly intervals were examined for antibodies to Toxoplasma gondii by enzyme-linked immunosorbent assay (ELISA). Distributions of immunoglobulin (Ig) G antibody levels for 6 age groups consistently showed two antibody groups with constant mean ELISA values. Quantitative analysis of annual changes in IgG antibody levels for 1,366 pairs indicated increase of ≥0.1 in 28 samples and decrease of ≥0.1 in 58 samples, with the remaining 1,280 samples showing changes of <0.1. Mean ELISA values of samples with increase and decrease were 0.479 and 0.833, respectively, and the difference of 0.354 was similar to 0.412, that was the sum total of mean annual changes in samples with increase (0.228) and decrease (0.184). Increase of ≥0.1 from the initial IgG antibody level of <0.1, which was considered as a serological evidence for newly acquired infection, was observed in 3 samples, but no increase was demonstrated in IgM antibody level. The changing pattern of IgG and IgM antibody levels in people during the initial and chronic phases of asymptomatic infections is discussed.  相似文献   

18.
A specific and rapid enzyme-linked immunosorbent assay (ELISA) has been applied for the detection of immunoglobulins to Staphylococcus epidermidis cell surface polysaccharides in human serum. Positive IgG, IgM and IgA titres of more than 1:6400, 1:1600 and 1:400 were observed with this assay against passive protective human serum. However, IgG, IgM and IgA titres of less than 1:400, 1:100 and 1:50 were shown in non-protective serum. When the cross-reactivity of passive protective human serum to homologous and heterologous cell surface polysaccharides was examined by inhibition test with ELISA, remarkable inhibition was shown with homologous cell surface polysaccharide, whereas no inhibition was observed with heterologous substances. According to these results, the quantitation of human serum antibody by the ELISA method against Staph. epidemidis cell surface polysaccharide was found to be significant for the demonstration of passive protective activities against Staph. epidermidis.  相似文献   

19.
A specific and rapid enzyme-linked immunosorbent assay (ELISA) has been applied for the detection of immunoglobulins to Staphylococcus epidermidis cell surface polysaccharides in human serum. Positive IgG, IgM and IgA titres of more than 1: 6400, 1: 1600 and 1: 400 were observed with this assay against passive protective human serum. However, IgG, IgM and IgA titres of less than 1: 400, 1: 100 and 1: 50 were shown in non-protective serum. When the cross-reactivity of passive protective human serum to homologous and heterologous cell surface polysaccharides was examined by inhibition test with ELISA, remarkable inhibition was shown with homologous cell surface polysaccharide, whereas no inhibition was observed with heterologous substances. According to these results, the quantitation of human serum antibody by the ELISA method against Staph. epidermidis cell surface polysaccharide was found to be significant for the demonstration of passive protective activities against Staph. epidermidis.  相似文献   

20.
We report here on the development of a sensitive and convenient enzyme-linked immunosorbent assay (ELISA) for feline IgG by using commercially available reagents and optimizing their concentrations. The reagents employed include goat anti-cat IgG antibody and alkaline phosphatase-conjugated goat anti-cat IgG antibody. The assay described is sensitive, reproducible, and highly specific for feline IgG. The assay was applied for the measurement of feline IgG synthesized and secreted in vitro by peripheral blood mononuclear cells cultured with or without a polyclonal B-cell activator. The amounts of secreted IgG in the supernatants measured by an ELISA correlated well with the numbers of IgG-secreting cells which were induced upon stimulation with pokeweed mitogen and determined by a reverse hemolytic plaque assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号