首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 ± 5.8 CFU/m2 for wet sampling and 100.5 ± 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site.  相似文献   

2.
Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 +/- 5.8 CFU/m2 for wet sampling and 100.5 +/- 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site.  相似文献   

3.
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.  相似文献   

4.

Background

The global need for disease detection and control has increased effort to engineer point-of-care (POC) tests that are simple, robust, affordable, and non-instrumented. In many POC tests, sample collection involves swabbing the site (e.g., nose, skin), agitating the swab in a fluid to release the sample, and transferring the fluid to a device for analysis. Poor performance in sample transfer can reduce sensitivity and reproducibility.

Methods

In this study, we compared bacterial release efficiency of seven swab types using manual-agitation methods typical of POC devices. Transfer efficiency was measured using quantitative PCR (qPCR) for Staphylococcus aureus under conditions representing a range of sampling scenarios: 1) spiking low-volume samples onto the swab, 2) submerging the swab in excess-volume samples, and 3) swabbing dried sample from a surface.

Results

Excess-volume samples gave the expected recovery for most swabs (based on tip fluid capacity); a polyurethane swab showed enhanced recovery, suggesting an ability to accumulate organisms during sampling. Dry samples led to recovery of ∼20–30% for all swabs tested, suggesting that swab structure and volume is less important when organisms are applied to the outer swab surface. Low-volume samples led to the widest range of transfer efficiencies between swab types. Rayon swabs (63 µL capacity) performed well for excess-volume samples, but showed poor recovery for low-volume samples. Nylon (100 µL) and polyester swabs (27 µL) showed intermediate recovery for low-volume and excess-volume samples. Polyurethane swabs (16 µL) showed excellent recovery for all sample types. This work demonstrates that swab transfer efficiency can be affected by swab material, structure, and fluid capacity and details of the sample. Results and quantitative analysis methods from this study will assist POC assay developers in selecting appropriate swab types and transfer methods.  相似文献   

5.
AIM: To evaluate US Centers for Disease Control and Prevention recommended swab surface sample collection method for recovery efficiency and limit of detection for powdered Bacillus spores from nonporous surfaces. METHODS AND RESULTS: Stainless steel and painted wallboard surface coupons were seeded with dry aerosolized Bacillus atrophaeus spores and surface concentrations determined. The observed mean rayon swab recovery efficiency from stainless steel was 0.41 with a standard deviation (SD) of +/-0.17 and for painted wallboard was 0.41 with an SD of +/-0.23. Evaluation of a sonication extraction method for the rayon swabs produced a mean extraction efficiency of 0.76 with an SD of +/-0.12. Swab recovery quantitative limits of detection were estimated at 25 colony forming units (CFU) per sample area for both stainless steel and painted wallboard. CONCLUSIONS: The swab sample collection method may be appropriate for small area sampling (10 -25 cm2) with a high agent concentration, but has limited value for large surface areas with a low agent concentration. The results of this study provide information necessary for the interpretation of swab environmental sample collection data, that is, positive swab samples are indicative of high surface concentrations and may imply a potential for exposure, whereas negative swab samples do not assure that organisms are absent from the surfaces sampled and may not assure the absence of the potential for exposure. SIGNIFICANCE AND IMPACT OF THE STUDY: It is critical from a public health perspective that the information obtained is accurate and reproducible. The consequence of an inappropriate public health response founded on information gathered using an ineffective or unreliable sample collection method has the potential for undesired social and economic impact.  相似文献   

6.
The conditions of ultrasonication to recover micro-organisms from material surfaces are not standardized and often not validated. This leads to discrepancies in experimental results which can affect the sterilization dose setting, cycle development and process validation, and can have an impact on sterilization processing economics and product sterile quality. The sample loading pattern, species of micro-organism, materials and configurations of sample containers were examined under defined conditions. All of these were found to be important factors contributing to the efficiency of microbial recovery from material surfaces by ultrasonication. Validation of sonication conditions in routine laboratory operations is therefore important for an accurate estimate of the surface contamination to assure the medical device processing and the product sterile quality.  相似文献   

7.
Aims: Having and executing a well-defined and validated sampling protocol is critical following a purposeful release of a biological agent for response and recovery activities, for clinical and epidemiological analysis and for forensic purposes. The objective of this study was to address the need for validated sampling and analysis methods called out by the General Accounting Office and others to systematically compare the collection efficiency of various swabs and wipes for collection of bacterial endospores from five different surfaces, both porous and nonporous. This study was also designed to test the collection and extraction solutions used for endospore recovery from swabs and wipes. Methods and Results: Eight collection tools, five swabs and three wipes, were used. Three collection/preservation solutions were evaluated: an ink jet aerosol generator was used to apply Bacillus subtilis endospores to five porous and nonporous surfaces. The collection efficiencies of the swabs and wipes were compared using a statistical multiple comparison analysis. Conclusions: The ScottPure® wipe had the highest collection efficiency and phosphate-buffered saline (PBST) with 0·3% Tween was the best collection solution of those tested. Significance and Impact of the Study: Validated sampling for potential biological warfare is of significant importance and this study answered some relevant questions.  相似文献   

8.
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.  相似文献   

9.
Aim: We will validate sample collection methods for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. Methods and Results: We evaluated the sample recovery efficiencies of two collection methods – swabs and wipes – for both nonvirulent and virulent strains of Bacillus anthracis and Yersinia pestis from four types of nonporous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using real‐time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface‐dependent for virulent strains than nonvirulent strains. For the two nonvirulent strains, collection efficiency was similar between all four surfaces, albeit B. anthracis Sterne exhibited higher levels of recovery compared to Y. pestis A1122. In contrast, recovery of B. anthracis Ames spores and Y. pestis CO92 from the hydrophilic glass or stainless steel surfaces was generally more efficient compared to collection from the hydrophobic vinyl and plastic surfaces. Conclusions: Our results suggest that surface hydrophobicity may play a role in the strength of pathogen adhesion. The surface‐dependent collection efficiencies observed with the virulent strains may arise from strain‐specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. Significance and Impact of the Study: These findings contribute to the validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.  相似文献   

10.
The use of non-destructive sampling methods to collect genetic material from wildlife allows researchers to minimize disturbance. Most avian studies employ capturing and handling of young and parents to draw blood for DNA analysis. In some cases adult female birds are difficult to catch, so maternal genotyping has required collection of contour feathers from nests, or destructive sampling of eggs. Many species do not leave contour feathers in the nest, and destructive sampling has been unreliable due to contamination with embryonic DNA. Alternative field sampling techniques for collection of maternal DNA from birds are therefore desirable. Here we demonstrate that avian maternal DNA can be isolated in a non-invasive and non-destructive way from the external surface of eggs. We used cotton swabs to collect maternal DNA from the external shells of herring gull (Larus argentatus) and Caspian tern (Sterna caspia) eggs. DNA was then amplified by the polymerase chain reaction (PCR) for microsatellite genotyping. We verified that the DNA samples were maternal by comparing microsatellite profiles to those obtained from adults and chicks from the same nests. In 100% of Caspian tern (n=16) and herring gull families (n=12), the egg swabs that amplified matched the maternal microsatellite genotype. In a screening of many nests of both species, we successfully amplified microsatellite markers from 101/115 (88%) egg swabs. Swabs from eggs with blood stains on the shell were more likely to amplify successfully than those from clean eggs. The advantages of this new method include increased parentage assignment/exclusion power, and increased availability of maternal DNA for genotyping of species that do not deposit contour feathers in nests.  相似文献   

11.
To gain information on laboratory hygiene in contained-use laboratories, a method was developed to study the presence of microorganisms on laboratory equipment. Focusing detection on genetically modified organisms (GMOs) containing the universal M13 primer binding sites enabled the detection of a broad range of GMOs using a single PCR. Swabbing surfaces in three different contained-use laboratories led to detection of M13-containing PCR products in 26 out of 34 swabs. Most sequences (up to five per sample) were detected in swabs from the centrifuge and sink, followed by swabs taken from the bin and incubator (up to four sequences per sample). The obtained sequences varied in length from 171 nucleotides (nt) to 878 nt. In most cases, sequences were only partially similar to sequences published in GenBank. The lengths of the regions with high similarity varied from 94 nt to 795 nt, and these similarities ranged from 81% to 100%. Similarities with more than one sequence were commonly found, complicating the identification of detected sequences. Nonetheless, 84% of the detected sequences were actually handled in the laboratory at the time of sampling. This demonstrates that the method may be used as a quality control tool to assess the efficacy of decontamination and cleaning of commonly used surfaces, such as laboratory benches, freezer doors, and centrifuge rotors, without prior knowledge of the identity or characteristics of the GMOs.  相似文献   

12.
The environmental DNA (eDNA) method is the practice of collecting environmental samples and analyzing them for the presence of a genetic marker specific to a target species. Little is known about the sensitivity of the eDNA method. Sensitivity is the probability that the target marker will be detected if it is present in the water body. Methods and tools are needed to assess the sensitivity of sampling protocols, design eDNA surveys, and interpret survey results. In this study, the sensitivity of the eDNA method is modeled as a function of ambient target marker concentration. The model accounts for five steps of sample collection and analysis, including: 1) collection of a filtered water sample from the source; 2) extraction of DNA from the filter and isolation in a purified elution; 3) removal of aliquots from the elution for use in the polymerase chain reaction (PCR) assay; 4) PCR; and 5) genetic sequencing. The model is applicable to any target species. For demonstration purposes, the model is parameterized for bighead carp (Hypophthalmichthys nobilis) and silver carp (H. molitrix) assuming sampling protocols used in the Chicago Area Waterway System (CAWS). Simulation results show that eDNA surveys have a high false negative rate at low concentrations of the genetic marker. This is attributed to processing of water samples and division of the extraction elution in preparation for the PCR assay. Increases in field survey sensitivity can be achieved by increasing sample volume, sample number, and PCR replicates. Increasing sample volume yields the greatest increase in sensitivity. It is recommended that investigators estimate and communicate the sensitivity of eDNA surveys to help facilitate interpretation of eDNA survey results. In the absence of such information, it is difficult to evaluate the results of surveys in which no water samples test positive for the target marker. It is also recommended that invasive species managers articulate concentration-based sensitivity objectives for eDNA surveys. In the absence of such information, it is difficult to design appropriate sampling protocols. The model provides insights into how sampling protocols can be designed or modified to achieve these sensitivity objectives.  相似文献   

13.
Noninvasive sampling methods for studying intestinal microbiomes are widely applied in studies of endangered species and in those conducting temporal monitoring during manipulative experiments. Although existing studies show that noninvasive sampling methods among different taxa vary in their accuracy, no studies have yet been published comparing nonlethal sampling methods in adult amphibians. In this study, we compare microbiomes from two noninvasive sample types (faeces and cloacal swabs) to that of the large intestine in adult cane toads, Rhinella marina. We use 16S rRNA gene sequencing to investigate how microbial communities change along the digestive tract and which nonlethal sampling method better represents large intestinal microbiota. We found that cane toads' intestinal microbiota was dominated by Bacteroidetes, Proteobacteria and Firmicutes and, interestingly, we also saw a high proportion of Fusobacteria, which has previously been associated with marine species and changes in frog immunity. The large and small intestine of cane toads had a similar microbial composition, but the large intestine showed higher diversity. Our results indicate that cloacal swabs were more similar to large intestine samples than were faecal samples, and small intestine samples were significantly different from both nonlethal sample types. Our study provides valuable information for future investigations of the cane toad gut microbiome and validates the use of cloacal swabs as a nonlethal method to study changes in the large intestine microbiome. These data provide insights for future studies requiring nonlethal sampling of amphibian gut microbiota.  相似文献   

14.
Gut microbial communities play critical roles in the biological functions of their host, such as mediating nutrient absorption, digesting food components the host cannot, and offering protection against enteric pathogens. Extensive research on gut microbial communities has been conducted on mammals, including humans and rodents, but much less work has been done in birds. Furthermore, much of the research on host–microbe interactions make use of faecal samples and rectal/cloacal swabs as a proxy for intestinal samples, which can be difficult to obtain directly. However, little is known about the overlap between the microbial communities of the gut, faeces and swabs, which limits interpretability of results based on faecal samples and swabs. To address this gap in knowledge, we compared the microbiome from five sample types – proventriculus, small intestine, large intestine, cloacal swabs and faeces – across individual Zebra Finches Taeniopygia guttata housed in constant conditions with a standardized diet. We compared diversity and community composition through 16S rRNA gene sequencing. Our results show that microbial communities from both cloacal swabs and faeces were distinct from proventriculus and small intestinal samples, but generally indistinguishable from large intestinal samples, indicating that these non-lethal samples may be useful proxies for large intestinal bacterial communities. Gaining insight into non-invasive sampling techniques for passerines has implications for studies of gut microbial diversity and abundance in wild bird populations. Furthermore, reliable non-lethal sampling is necessary for experiments where repeated sampling is required.  相似文献   

15.
Buccal cells are increasingly used as a source of quality DNA to improve participation rates in molecular studies. Here, three buccal cell collection protocols were compared to determine factors affecting the yield of cells, total DNA per sample, and DNA yield per cell. In addition, kinetic quantitative polymerase chain reaction (PCR) (TaqMan?) was used to quantify human DNA available for PCR. The method of collection used influenced the overall DNA yield per sample. The collection buffer used influenced the number of cells but not the overall DNA yield per sample. Repeated freezing and thawing did not affect overall DNA yield per sample, DNA yield per cell, or the total number of cells collected. Mouthwashes had the highest DNA yield per sample (20.8 μg) compared with cytobrush samples (1.9 μg from three cytobrushes) and tongue depressors (0.8 μg from three tongue depressors). However, mouthwash samples may contain significant non-human DNA and other contaminants that could interfere with some molecular studies. Spectrometry grossly overestimated the total DNA recovered from mouthwash samples compared with fluorometry or quantitative PCR.  相似文献   

16.
Buccal cells are increasingly used as a source of quality DNA to improve participation rates in molecular studies. Here, three buccal cell collection protocols were compared to determine factors affecting the yield of cells, total DNA per sample, and DNA yield per cell. In addition, kinetic quantitative polymerase chain reaction (PCR) (TaqMan™) was used to quantify human DNA available for PCR. The method of collection used influenced the overall DNA yield per sample. The collection buffer used influenced the number of cells but not the overall DNA yield per sample. Repeated freezing and thawing did not affect overall DNA yield per sample, DNA yield per cell, or the total number of cells collected. Mouthwashes had the highest DNA yield per sample (20.8 µg) compared with cytobrush samples (1.9 µg from three cytobrushes) and tongue depressors (0.8 µg from three tongue depressors). However, mouthwash samples may contain significant non-human DNA and other contaminants that could interfere with some molecular studies. Spectrometry grossly overestimated the total DNA recovered from mouthwash samples compared with fluorometry or quantitative PCR.  相似文献   

17.
Genomics tools (gene- and protein-expression studies) can be used to find possible target genes involved in a quantifiable trait or disease state. However in many instances, cells and tissues directly involved in the trait's expression, for example, brain tissue, are not amenable for gene expression analysis. Whole blood cells share a molecular make-up for cellular communication and gene regulation systems with many other cell types, for example, neuronal cells, and have the advantage of being very accessible for gene profiling. We investigated the feasibility of nationwide blood sample collection for lymphocyte RNA isolation and real-time PCR analysis to quantify genomic responses. We tested several designs for blood collection and storage: blood sampling in PAXgene blood collection tubes and storage at -20 degrees C, blood sampling in heparin tubes and decanting the samples (with or without in-vitro stimulus) into either PAXgene blood collection tubes and storage at -20 degrees C, or polypropylene tubes followed by snap-freezing and storage at -80 degrees C. The latter procedure is the best cost-wise when only small amounts of total RNA are needed for downstream applications. Lymphocyte gene expression studies are most likely hampered by the quality of isolated RNA rather than the sampling method. We show that large-scale nationwide sample collections did not alter RNA quality or gene expression levels when compared to sampling and processing in a more controlled way. To this end, we present an optimized protocol for easy and standardized isolation of high quality RNA using the PAXgene isolation kit. Based on these results, we suggest that whole blood genomic data can be used as a genomic probe in experimental and clinical research.  相似文献   

18.
Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.  相似文献   

19.
Quantitative Taq nuclease assays (TNAs) (TaqMan PCR), nested PCR in combination with denaturing gradient gel electrophoresis (DGGE), and epifluorescence microscopy were used to analyze the autotrophic picoplankton (APP) of Lake Constance. Microscopic analysis revealed dominance of phycoerythrin (PE)-rich Synechococcus spp. in the pelagic zone of this lake. Cells passing a 3- micro m-pore-size filter were collected during the growth period of the years 1999 and 2000. The diversity of PE-rich Synechococcus spp. was examined using DGGE to analyze GC-clamped amplicons of a noncoding section of the 16S-23S intergenic spacer in the ribosomal operon. In both years, genotypes represented by three closely related PE-rich Synechococcus strains of our culture collection dominated the population, while other isolates were traced sporadically or were not detected in their original habitat by this method. For TNAs, primer-probe combinations for two taxonomic levels were used, one to quantify genomes of all known Synechococcus-type cyanobacteria in the APP of Lake Constance and one to enumerate genomes of a single ecotype represented by the PE-rich isolate Synechococcus sp. strain BO 8807. During the growth period, genome numbers of known Synechococcus spp. varied by 2 orders of magnitude (2.9 x 10(3) to 3.1 x 10(5) genomes per ml). The ecotype Synechococcus sp. strain BO 8807 was detected in every sample at concentrations between 1.6 x 10(1) and 1.3 x 10(4) genomes per ml, contributing 0.02 to 5.7% of the quantified cyanobacterial picoplankton. Although the quantitative approach taken in this study has disclosed several shortcomings in the sampling and detection methods, this study demonstrated for the first time the extensive internal dynamics that lie beneath the seemingly arbitrary variations of a population of microbial photoautotrophs in the pelagic habitat.  相似文献   

20.
Despite advances in the specificity and sensitivity of molecular biological technologies, the efficient recovery of DNA from low-biomass samples remains extremely challenging. Optimal methods to purify biomolecules from such environments should (1) achieve the greatest total yield and (2) reflect the true microbial diversity of the sample. These attributes were assessed from five DNA purification regimes: a standard-manual procedure, MoBio Ultraclean and Promega Wizard kits, and an automated Axcyte AutoLyser method with and without bead-beating agitation. A homogenous mixture of known concentrations of nine distinct bacterial lineages isolated from low-biomass environments was prepared and suitable aliquots of subsamples were processed in parallel. DNA products from each of these methods were then subjected to polymerase chain reaction (PCR), quantitative PCR and 16S rRNA clone-library analysis. The Axcyte AutoLyser outperformed all other purification regimes examined. This automated method consistently both yielded the highest concentration of PCR-amplifiable DNA, and reported species composition most consistent with the starting solution.

PRACTICAL APPLICATIONS


This communication carefully examines the effectiveness of common DNA purification regimes as well as an automated method. Comparative analyses convincingly demonstrate that the different methods not only result in different recovery of genomic DNA, but more importantly, different estimations of microbial diversity in the sample. This report will hopefully inspire investigators from various industries (pharmaceutical, ecological, medical, semiconductor, etc.) who find themselves in the initial phases of large-scale studies to devote a significant effort into optimizing sample extraction protocols to achieve the most accurate information.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号