首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
A mediator-less microbial fuel cell (MFC) was used as a biochemical oxygen demand (BOD) sensor in an amperometric mode for real-time wastewater monitoring. At a hydraulic retention time of 1.05 h, BOD values of up to 100 mg/l were measured based on a linear relationship, while higher BOD values were measured using a lower feeding rate. About 60 min was required to reach a new steady-state current after the MFCs had been fed with different strength artificial wastewaters (Aws). The current generated from the MFCs fed with AW with a BOD of 100 mg/l was compared to determine the repeatability, and the difference was less than 10%. When the MFC was starved, the original current value was regained with a varying recovery time depending on the length of the starvation. During starvation, the MFC generated a background level current, probably due to an endogenous metabolism.  相似文献   

2.
The dynamic behavior of a mediator-less, microbial fuel cell (MFC) was studied as a continuous biochemical oxygen demand (BOD) sensor. The response time and the sensitivity were analyzed through the step-change testing of the fuel concentration. The MFC of 25 ml had the shortest response time of 36± 2 min at the fuel-feeding rate of 0.53 ml min–1 and the resistance of 10 A smaller MFC of 5 ml had a response time of 5± 1 min.  相似文献   

3.
Two different microbial fuel cell (MFC) configurations were investigated for electricity production from ethanol and methanol: a two-chambered, aqueous-cathode MFC; and a single-chamber direct-air cathode MFC. Electricity was generated in the two-chamber system at a maximum power density typical of this system (40+/-2 mW/m2) and a Coulombic efficiency (CE) ranging from 42% to 61% using ethanol. When bacteria were transferred into a single-chamber MFC known to produce higher power densities with different substrates, the maximum power density increased to 488+/-12 mW/m2 (CE = 10%) with ethanol. The voltage generated exhibited saturation kinetics as a function of ethanol concentration in the two-chambered MFC, with a half-saturation constant (Ks) of 4.86 mM. Methanol was also examined as a possible substrate, but it did not result in appreciable electricity generation. Analysis of the anode biofilm and suspension from a two-chamber MFC with ethanol using 16S rDNA-based techniques indicated that bacteria with sequences similar to Proteobacterium Core-1 (33.3% of clone library sequences), Azoarcus sp. (17.4%), and Desulfuromonas sp. M76 (15.9%) were significant members of the anode chamber community. These results indicate that ethanol can be used for sustained electricity generation at room temperature using bacteria on the anode in a MFC.  相似文献   

4.
In this work, it has been studied the production of electricity and the oxidation of the pollutants contained in a synthetic wastewater fed with glucose and peptone of soybean as carbon sources, using a mediator-less microbial fuel cell (MFC). Special attention has been paid to the acclimation stage, in which it was found that with high hydraulic and solid retention times it is possible to obtain a very efficient process with a 90% COD removal and practically total conversion of COD into electricity (considering the typical stoichiometric yield of heterotrophic biomass). The influence of concentration sludge was studied working with three different amounts of suspended solids, from 120 to 14000 mg. The maximum power density increased exponentially with the concentration sludge from 2.1 mW m−2 to 11 mW m−2 at the highest concentration sludge. More over, the percentage of the influent COD used to produce electricity was higher than 100% when the highest sludge concentration was used. This was explained taking into account the endogenous metabolism of micro-organisms presented in the system.  相似文献   

5.
A mediator-less three-stage two-chamber microbial fuel cell (MFC) system was developed and operated continuously for more than 1.5 years to evaluate continuous power generation while treating artificial wastewater containing glucose (10 mM) concurrently. A stable power density of 28 W/m3 was attained with an anode hydraulic retention time of 4.5 h and phosphate buffer as the cathode electrolyte. An overall dissolved organic carbon removal ratio was about 85%, and coulombic efficiency was about 46% in this MFC system. We also analyzed the microbial community structure of anode biofilms in each MFC. Since the environment in each MFC was different due to passing on the products to the next MFC in series, the microbial community structure was different accordingly. The anode biofilm in the first MFC consisted mainly of bacteria belonging to the Gammaproteobacteria, identified as Aeromonas sp., while the Firmicutes dominated the anode biofilms in the second and third MFCs that were mainly fed with acetate. Cyclic voltammetric results supported the presence of a redox compound(s) associated with the anode biofilm matrix, rather than mobile (dissolved) forms, which could be responsible for the electron transfer to the anode. Scanning electron microscopy revealed that the anode biofilms were comprised of morphologically different cells that were firmly attached on the anode surface and interconnected each other with anchor-like filamentous appendages, which might support the results of cyclic voltammetry. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

6.
A two-chambered microbial fuel cell (MFC) with potassium ferricyanide as its electron acceptor was utilized to degrade excess sewage sludge and to generate electricity. Stable electrical power was produced continuously during operation for 250 h. Total chemical oxygen demand (TCOD) of sludge was reduced by 46.4% when an initial TCOD was 10,850 mg/l. The MFC power output did not significantly depend on process parameters such as substrate concentration, cathode catholyte concentration, and anodic pH. However, the MFC produced power was in close correlation with the soluble chemical oxygen demand (SCOD) of sludge. Furthermore, ultrasonic pretreatment of sludge accelerated organic matter dissolution and, hence, TCOD removal rate in the MFC was increased, but power output was insignificantly enhanced. This study demonstrates that this MFC can generate electricity from sewage sludge over a wide range of process parameters.  相似文献   

7.
介绍微生物燃料电池的基本工作原理。根据电子传递方式阳极产电微生物分为无需中间体微生物和需中间体微生物。对阴极进行不同反应所涉及的最终电子受体进行了概述,并展望了微生物燃料电池的应用前景。  相似文献   

8.
Electrochemical impedance spectroscopy (EIS) was used to study the behavior of a microbial fuel cell (MFC) during initial biofilm growth in an acetate-fed, two-chamber MFC system with ferricyanide in the cathode. EIS experiments were performed both on the full cell (between cathode and anode) as well as on individual electrodes. The Nyquist plots of the EIS data were fitted with an equivalent electrical circuit to estimate the contributions of various intrinsic resistances to the overall internal MFC impedance. During initial development of the anode biofilm, the anode polarization resistance was found to decrease by over 70% at open circuit and by over 45% at 27 microA/cm(2), and a simultaneous increase in power density by about 120% was observed. The exchange current density for the bio-electrochemical reaction on the anode was estimated to be in the range of 40-60 nA/cm(2) for an immature biofilm after 5 days of closed circuit operation, which increased to around 182 nA/cm(2) after more than 3 weeks of operation and stable performance in an identical parallel system. The polarization resistance of the anode was 30-40 times higher than that of the ferricyanide cathode for the conditions tested, even with an established biofilm. For a two-chamber MFC system with a Nafion 117 membrane and an inter-electrode spacing of 15 cm, the membrane and electrolyte solution dominate the ohmic resistance and contribute to over 95% of the MFC internal impedance. Detailed EIS analyses provide new insights into the dominant kinetic resistance of the anode bio-electrochemical reaction and its influence on the overall power output of the MFC system, even in the high internal resistance system used in this study. These results suggest that new strategies to address this kinetic constraint of the anode bio-electrochemical reactions are needed to complement the reduction of ohmic resistance in modern designs.  相似文献   

9.
In this study, a two-compartment continuous flow microbial fuel cell (MFC) reactor was used to compare the efficiencies of cathode oxygenation by air and by hydrogen peroxide. The MFC reactor had neither a proton-selective membrane nor an electron transfer mediator. At startup, the cathodic compartment was continuously aerated and the anodic compartment was fed with a glucose solution. An increase of electrical power generation from 0.008 to 7.2 mW m(-2) of anode surface with a steady-state potential of 215-225 mV was observed within a period of 12 days. The performance of the air-oxygenated MFC reactor progressively declined over time because of biofilm proliferation in the cathodic compartment. Oxygenation of the cathodic compartment using 300 mL d(-1) of 0.3% hydrogen peroxide solution resulted in a power density of up to 22 mW m(-2) (68.2 mA m(-2)) of anode surface at a potential of 340-350 mV. The use of H2O2 for oxygenation was found to improve the long-term stability of the MFC reactor.  相似文献   

10.
Development of a solar-powered microbial fuel cell   总被引:1,自引:0,他引:1  
Aims: To understand factors that impact solar‐powered electricity generation by Rhodobacter sphaeroides in a single‐chamber microbial fuel cell (MFC). Methods and Results: The MFC used submerged platinum‐coated carbon paper anodes and cathodes of the same material, in contact with atmospheric oxygen. Power was measured by monitoring voltage drop across an external resistance. Biohydrogen production and in situ hydrogen oxidation were identified as the main mechanisms for electron transfer to the MFC circuit. The nitrogen source affected MFC performance, with glutamate and nitrate‐enhancing power production over ammonium. Conclusions: Power generation depended on the nature of the nitrogen source and on the availability of light. With light, the maximum point power density was 790 mW m?2 (2·9 W m?3). In the dark, power output was less than 0·5 mW m?2 (0·008 W m?3). Also, sustainable electrochemical activity was possible in cultures that did not receive a nitrogen source. Significance and Impact of the Study: We show conditions at which solar energy can serve as an alternative energy source for MFC operation. Power densities obtained with these one‐chamber solar‐driven MFC were comparable with densities reported in nonphotosynthetic MFC and sustainable for longer times than with previous work on two‐chamber systems using photosynthetic bacteria.  相似文献   

11.
Sustainable electricity was generated from glucose in up-flow air-cathode microbial fuel cells (MFCs) with carbon cloth cathode and carbon granular anode. Plastic sieves rather than membrane were used to separate the anode and cathode. Based on 1g/l glucose as substrate, a maximum volumetric power density of 25+/-4 W/m(3) (89 A/m(3)) was obtained for the MFC with a sieve area of 30 cm(2) and 49+/-3 W/m(3) (215 A/m(3)) for the MFC with a sieve area of 60 cm(2). The increased power density with larger sieve area was mainly due to the decrease of internal resistance according to the electrochemistry impedance spectroscopy analysis. Increasing the sieve area from 30 cm(2) to 60 cm(2) resulted in a decrease of overall internal resistance from 41 ohm to 27.5 ohm and a decrease of ohmic resistance from 24.3 ohm to 14 ohm. While increasing operational recirculation ratio (RR) decreased internal resistance and increased power output at low substrate concentration, the effect of RR on cell performance was negligible at higher substrate concentration.  相似文献   

12.
This study reports the fabrication of a new membrane electrode assembly by using stainless steel mesh (SSM) as raw material and its effectiveness as gas diffusion electrode (GDE) for electrochemical oxygen reduction in microbial fuel cell (MFC). Based on feeding glucose (0.5 g L(-1)) substrate to a single-chambered MFC, power generation using SSM-based GDE was increased with the decrease of polytetrafluoroethylene (PTFE) content applied during fabrication, reaching the optimum power density of 951.6 mW m(-2) at 20% PTFE. Repeatable cell voltage of 0.51 V (external resistance of 400 Ω) and maximum power density of 951.6 mW m(-2) produced for the MFC with SSM-based GDE are comparable to that of 0.52 V and 972.6 mW m(-2), respectively obtained for the MFC containing typical carbon cloth (CC)-made GDE. Besides, Coulombic efficiency (CE) is found higher for GDE (SSM or CC) with membrane assembly than without, which results preliminarily from the mitigation of Coulombic loss being associated with oxygen diffusion and substrate crossover. This study demonstrates that with its good electrical conductivity and much lower cost, the SSM-made GDE suggests a promising alternative as efficient and more economically viable material to conventional typical carbon for power production from biomass in MFC.  相似文献   

13.
Biochemical functioning of single chambered microbial fuel cell (MFC) using glass wool as proton exchange membrane (PEM) operated with selectively enriched acidogenic mixed culture was evaluated in terms of bioelectricity production and wastewater treatment. Performance of MFC was studied at two different organic/substrate loading rates (OLR) (2.64 and 3.54 kg COD/m(3)) and operating pH 6 and 7 using non-coated plain graphite electrodes (mediatorless anode; air cathode). Applied OLR in association with operating pH showed marked influence on the power output and substrate degradation efficiency. Higher current density was observed at acidophilic conditions [pH 6; 98.13 mA/m(2) (2.64 kg COD/m(3)-day; 100 Omega) and 111.29 mA/m(2) (3.54 kg COD/m(3)-day; 100 Omega)] rather than neutral conditions [pH 7; 100.52 mA/m(2) (2.64 kg COD/m(3)-day; 100 Omega) and 98.13 mA/m(2) (3.54 kg COD/m(3)-day; 100 Omega)]. On the contrary, effective substrate degradation was observed at neutral pH. MFC performance was evaluated employing polarization curve, impedance analysis, cell potential, Coulombic efficiency and bioprocess monitoring. Sustainable power yield was calculated at stable cell potential.  相似文献   

14.
A microbial fuel cell (MFC) is a relatively new type of fixed film bioreactor for wastewater treatment, and the most effective methods for inoculation are not well understood. Various techniques to enrich electrochemically active bacteria on an electrode were therefore studied using anaerobic sewage sludge in a two-chambered MFC. With a porous carbon paper anode electrode, 8 mW/m2 of power was generated within 50 h with a Coulombic efficiency (CE) of 40%. When an iron oxide-coated electrode was used, the power and the CE reached 30 mW/m2 and 80%, respectively. A methanogen inhibitor (2-bromoethanesulfonate) increased the CE to 70%. Bacteria in sludge were enriched by serial transfer using a ferric iron medium, but when this enrichment was used in a MFC the power was lower (2 mW/m2) than that obtained with the original inoculum. By applying biofilm scraped from the anode of a working MFC to a new anode electrode, the maximum power was increased to 40 mW/m2. When a second anode was introduced into an operating MFC the acclimation time was not reduced and the total power did not increase. These results suggest that these active inoculating techniques could increase the effectiveness of enrichment, and that start up is most successful when the biofilm is harvested from the anode of an existing MFC and applied to the new anode.  相似文献   

15.
Electricity generation integrated with xylose degradation was investigated in a two-chamber mediator-less microbial fuel cell (MFC). Voltage output followed saturation kinetics as a function of xylose concentration for concentration below 9.7 mM, with a predicted maximum of 86 mV (6.3 mW m(-2) or 116 mW m(-3)) and half-saturation constant (K(s)) of 0.29 mM. Xylose concentrations from 0.5 mM to 1.5 mM resulted in coulombic efficiencies and maximum voltage ranging from 41+/-1.6% to 36+/-1.2% and 55+/-2.0 mV to 70+/-3.0 mV respectively. Xylose degradation rate increased with increasing xylose concentration up to 9.7 mM and the predicted maximum degradation rate was 0.13 mM h(-1) and K(s) of 3.0 mM. Stirring by nitrogen in the anode chamber led to 99+/-2.3 mV maximum voltage (8.4+/-0.4 mW m(-2) or 153+/-7.1 mW m(-3)) and 5.9+/-0.3% coulombic efficiency at MFC running time 180 h, which were respectively 17+/-1.2% and 37+/-1.8%, higher than those without stirring. The COD removal under stirring was 22.1+/-0.3%, which was slightly lower than that of 23.7+/-0.4% under no stirring. However, stirring resulted in 59% lower xylose degradation rate. This work demonstrates that xylose can be used in the MFC for electricity production. Comparatively higher electricity generation and coulombic efficiency can be obtained by adjusting initial xylose concentration and applying stirring in the anode chamber.  相似文献   

16.
A study of the dynamic response of a microbial fuel cell (MFC) using membrane electrode assemblies (MEAs) designed for air breathing cathode operation is reported. The MFC used four MEAs simultaneously and has a low internal resistance. An increased concentration of glucose produced a non-linear increase in the maximum current reached. The time to reach the maximum current increased with increasing glucose concentrations of 1-7 mM; varying from approximately 2.4 to 4.2h. The rate at which the current density increased with time was the same for all glucose concentrations up to current densities close to the maximum values. The peak power density varied approximately linearly with glucose concentrations from 2 to 77 mW/m(2) (1-7 mM) with a 1 kΩ resistance. The cell response appeared to be linked to a slow process of fuel transport to the bacteria and their metabolic processes. The dynamic response of the anode was analysed in terms of a substrate mass transport model. The application of different current ranges did not significantly change the dynamic response of either the anode community or the MFC polarization characteristics. Thus, it is likely that the bacterial communities that form under MFC operation contain sufficiently "dominant" electro-active species that are capable of producing high power for MFCs.  相似文献   

17.
Li Z  Yao L  Kong L  Liu H 《Bioresource technology》2008,99(6):1650-1655
To make sure that microbial fuel cells (MFCs) are more convenient to stack, a baffled single-chambered MFC with two groups of electrodes sharing only one anode chamber was designed and the performance was examined. The experiments showed that the prototype MFC generated electrical power (maximum of 133 mW/m(2)) while removing up to 88% of chemical oxygen demand (COD) in 91 h. Volumetric power increased as electrode area per anode compartment volume increased, indicating that the MFC with two groups of electrodes was better than that with one group. Power density as a function of wastewater concentration was modeled according to saturation kinetics, with a maximum power density of P(max)=164 mW/m(2) (fixed 100 Omega resistor) and half-saturation concentration of K(s)=259 mg/l. The hydraulic retention time (HRT) was examined as a factor influencing the power generation. When it was 15.5h, the voltage and the power density reached the maximum 0.413 V and 108 mW/m(2).  相似文献   

18.
Zhu F  Wang W  Zhang X  Tao G 《Bioresource technology》2011,102(15):7324-7328
A novel membrane-less microbial fuel cell (MFC) with down-flow feeding was constructed to generate electricity. Wastewater was fed directly onto the cathode which was horizontally installed in the upper part of the MFC. Oxygen could be utilized readily from the air. The concentration of dissolved oxygen in the influent wastewater had little effect on the power generation. A saturation-type relationship was observed between the initial COD and the power generation. The influent flow rate could affect greatly the power density. Fed by the synthetic glucose wastewater with a COD value of 3500 mg/L at a flow rate of 4.0 mL/min, the developed MFC could produce a maximum power density of 37.4 mW/m2. Its applicability was further evaluated by the treatment of brewery wastewater. The system could be scaled up readily due to its simple configuration, easy operation and relatively high power density.  相似文献   

19.
Electricity generation from microbial fuel cells which treat food processing wastewater was investigated in this study. Anaerobic anode and aerobic cathode chambers were separated by a proton exchange membrane in a two-compartment MFC reactor. Buffer solutions and food industry wastewater were used as electrolytes in the anode and cathode chambers, respectively. The produced voltage and current intensity were measured using a digital multimeter. Effluents from the anode compartment were tested for COD, BOD5, NH3, P, TSS, VSS, SO4 and alkalinity. The maximum current density and power production were measured 527 mA/m2 and 230 mW/m2 in the anode area, respectively, at operation organic loading (OLR) of 0.364 g COD/l.d. At OLR of 0.182 g COD/l.d, maximum voltage and columbic efficiency production were recorded 0.475 V and 21%, respectively. Maximum removal efficiency of COD, BOD5, NH3, P, TSS, VSS, SO4 and alkalinity were 86, 79, 73, 18, 68, 62, 30 and 58%, respectively. The results indicated that catalysts and mediator-less microbial fuel cells (CAML-MFC) can be considered as a better choice for simple and complete energy conversion from the wastewater of such industries and also this could be considered as a new method to offset wastewater treatment plant operating costs.  相似文献   

20.
Single chambered mediatorless microbial fuel cell (MFC; non-catalyzed electrodes) was operated to evaluate the potential of bioelectricity generation from the treatment of composite waste vegetables (EWV) extract under anaerobic microenvironment using mixed consortia as anodic biocatalyst. The system was operated with designed synthetic wastewater (DSW; 0.98 kg COD/m3-day) during adaptation phase and later shifted to EWV and operated at three substrate load conditions (2.08, 1.39 and 0.70 kg COD/m3-day). Experimental data illustrated the feasibility of bioelectricity generation through the utilization of EWV as substrate in MFC. Higher power output (57.38 mW/m2) was observed especially at lower substrate load. The performance of MFC was characterized based on the polarization behavior, cell potentials, cyclic voltammetric analysis and sustainable resistance. MFC operation also documented to stabilize the waste by effective removal of COD (62.86%), carbohydrates (79.84%) and turbidity (55.12%).  相似文献   