首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
The flow of blood in the presence of a magnetic field gives rise to induced voltages in the major arteries of the central circulatory system. Under certain simplifying conditions, such as the assumption that the length of major arteries (e.g., the aorta) is infinite and that the vessel walls are not electrically conductive, the distribution of induced voltages and currents within these blood vessels can be calculated with reasonable precision. However, the propagation of magnetically induced voltages and currents from the aorta into neighboring tissue structures such as the sinuatrial node of the heart has not been previously determined by any experimental or theoretical technique. In the analysis presented in this paper, a solution of the complete Navier-Stokes equation was obtained by the finite element technique for blood flow through the ascending and descending aortic vessels in the presence of a uniform static magnetic field. Spatial distributions of the magnetically induced voltage and current were obtained for the aortic vessel and surrounding tissues under the assumption that the wall of the aorta is electrically conductive. Results are presented for the calculated values of magnetically induced voltages and current densities in the aorta and surrounding tissue structures, including the sinuatrial node, and for their field-strength dependence. In addition, an analysis is presented of magnetohydrodynamic interactions that lead to a small reduction of blood volume flow at high field levels above approximately 10 tesla (T). Quantitative results are presented on the offsetting effects of oppositely directed blood flows in the ascending and descending aortic segments, and a quantitative estimate is made of the effects of assuming an infinite vs. a finite length of the aortic vessel in calculating the magnetically induced voltage and current density distribution in tissue. © 1996 Wiley-Liss, Inc.  相似文献   

4.
The effect of magnetic field (MF) exposure on microcirculation and microvasculature is not clear or widely explored. In the limited body of data that exists, there are contradictions as to the effects of MFs on blood perfusion and pressure. Approximately half of the cited studies indicate a vasodilatory effect of MFs; the remaining half indicate that MFs could trigger either vasodilation or vasoconstriction depending on initial vessel tone. Few studies indicate that MFs cause a decrease in perfusion or no effect. There is a further lack of investigation into the cellular effects of MFs on microcirculation and microvasculature. The role of nitric oxide (NO) in mediating microcirculatory MF effects has been minimally explored and results are mixed, with four studies supporting an increase in NO activity, one supporting a biphasic effect, and five indicating no effect. MF effects on angiogenesis are also reported: seven studies supporting an increase and two a decrease. Possible reasons for these contradictions are explored. This review also considers the effects of magnetic resonance imaging (MRI) and anesthetics on microcirculation. Recommendations for future work include studies aimed at the cellular/mechanistic level, studies involving perfusion measurements both during and post-exposure, studies testing the effect of MFs on anesthetics, and investigation into the microcirculatory effects of MRI.  相似文献   

5.
The objective study was to estimate the rheological properties and physiological compatibility of the blood pump by simulating the internal flow field of the blood pump. In this study we use computational fluid dynamics method to simulate and analyse two models of axial blood pumps with a three-blade diffuser and a six-blade diffuser, named pump I and pump II, respectively, and to compare the flow patterns of these two kinds of blood pumps while both of them satisfy the conditions of the normal human blood differential pressure and blood flow. Results indicate that (i) the high shear force occurs between the diffuser and the rotor in which the crucial place leads to haemolysis and (ii) under the condition of 100 mmHg pressure head and 5 l/min flow rate, the difference between the two kinds of blood pumps, as far as the haemolytic performance is concerned, is notable. The haemolysis index of the two pumps is 0.32% and 0.2%. In conclusion, the performance of the blood pump is influenced by the diffusers' blade number. Pump II performed better than pump I, which can be the basic model for blood pump option.  相似文献   

6.
The field of single-cell omics is rapidly progressing. Although DNA and RNA sequencing-based methods have dominated the field to date, global proteome profiling has also entered the main stage. Single-cell proteomics was facilitated by advancements in different aspects of mass spectrometry (MS)-based proteomics, such as instrument design, sample preparation, chromatography and ion mobility. Single-cell proteomics by mass spectrometry (scp-MS) has moved beyond being a mere technical development, and is now able to deliver actual biological application and has been successfully applied to characterize different cell states. Here, we review some key developments of scp-MS, provide a background to the field, discuss the various available methods and foresee possible future directions.  相似文献   

7.
Recent developments in the field of iron-sulfur proteins   总被引:18,自引:0,他引:18  
H Beinert 《FASEB journal》1990,4(8):2483-2491
This review considers recent information, in the following order, on complex proteins containing Fe-S clusters together with other prosthetic groups, on hydrogenases, unexpected functions of Fe-S clusters, novel cluster types, protein structures furnishing the cluster ligands, evolutionary aspects, and spectroscopic methods and theoretical approaches used or developed in the study of Fe-S proteins.  相似文献   

8.
Hojo H  Nakahara Y 《Biopolymers》2007,88(2):308-324
Glycosylation is a common post-translational modification of proteins. Although its significance in biological system is well recognized, approaches to analyze carbohydrate function are limited. This is because of difficulty in obtaining homogeneous glycoproteins from natural sources. Due to the progress of the carbohydrate and peptide chemistry, syntheses of various homogeneous glycopeptides and glycoproteins, which are suitable for biological studies, have been achieved by chemical means. In this review, we briefly summarize recent advances in the field of glycopeptide synthesis after 1999.  相似文献   

9.
Recent developments in the hammerhead ribozyme field.   总被引:9,自引:0,他引:9       下载免费PDF全文
Developments in the hammerhead ribozyme field during the last two years are reviewed here. New results on the specificity of this ribozyme, the mechanism of its action and on the question of metal ion involvement in the cleavage reaction are discussed. To demonstrate the potential of ribozyme technology examples of the application of this ribozyme for the inhibition of gene expression in cell culture, in animals, as well as in plant models are presented. Particular emphasis is given to critical steps in the approach, including RNA site selection, delivery, vector development and cassette construction.  相似文献   

10.
11.
A Kolin  J S Imai  J R Steele  M W Lenz 《Life sciences》1974,14(7):1291-1307
This paper describes the construction details and circuitry of a system for electromagnetic determination of blood flow by means of intravascular flow sensors passed through angiographic catheters introuced by percutaneous technique. The extracorporeal magnet coil is fed by a sinusodial current and the sinusodial induced flow signal is detected by a phase-sensitive amplifier. The main novel feature of this amplifier is a combination of phase-sensitive detection with a boxcar integrator which results in an exceptionally high signal-to-noise ratio. A two channel system is also described which permits simultaneous monitoring of a signal in phase quadrature with respect to the magnetic field and, hence, to the flow signal. This system makes it also possible to monitor variations in artery diameter which is measured through a transformer e.m.f. induced in a loop of the sensor whose area is modified by the artery diameter in a fashion securing approximate linear relationship between the artery diameter and the loop output. The loop output voltage is also used to ascertain the instrument calibration in case of an arbitrary orientation and distance from the magnet coil of the intravascular sensor.The intravascular sensor is a loop of insulated fine elastic wire which forms an oval frame which collapses as it is introduced through an intravascular catheter and expands maximally as it emerges into an artery which harbors the catheter end portion. Two diametrically opposed electrodes placed across the loop, pick up the flow signal induced in the blood stream by an extracorporeal air-core magnet coil whose magnetic axis is as nearly as possible perpendicular to the area of the sensor and to the artery axis.The paper reviews artifacts and the capabilities as well as the limitations of the method in its present form and suggests a solution for the main weakness--the inability to provide a reliable zero-based line without recourse to arrest of blood flow.  相似文献   

12.
In anesthetized mongrel dogs we measured the blood flow in the left phrenic artery (Qdi), using an electromagnetic flow probe, before and during supramaximal phrenic nerve stimulation (pacing). This was done at constant respiratory rate (24/min) but at three different stimulation frequencies at a duty cycle of 0.4 (20, 50, and 100 Hz) and at three different duty cycles at a stimulation frequency of 50 Hz (duty cycle = 0.2, 0.4, and 0.8). Qdi was unchanged during diaphragm contraction until transdiaphragmatic pressure (Pdi) was greater than approximately 11 cmH2O, whereafter it began to decrease, reaching zero at Pdi approximately 20 cmH2O. Thus, when Pdi was greater than 21 cmH2O, all flow occurred during relaxation. Qdi averaged over the entire respiratory cycle (Qt) was less at duty cycle = 0.8 than under the other conditions. This was because of decreasing length of relaxation phase rather than a difference of relaxation phase flow (Qr), which was maximal during all conditions of phrenic stimulation. During pacing-induced fatigue, Qt actually rose slightly as Pdi fell. This was due to an increase in contraction phase flow while Qr remained constant. The relationship between Qt and tension-time index was not unique but varied according to the different combinations of duty cycle and stimulus frequency.  相似文献   

13.
14.
15.
Reviews of Physiology, Biochemistry and Pharmacology -  相似文献   

16.
To test the hypothesis that fetal lambs are able to maintain oxygen delivery to myocardial, brain and adrenal tissues during reduction in uterine blood flow to 25% of control, we performed experiments on five ewes and their fetuses. A snare occluder was placed around the maternal common hypogastric artery and catheters were placed for measurement of blood pressures, flows, blood gas tensions, pH and oxygen content. After a five day recovery period, control measurements were made. The snare occluder was then closed until the artery was fully occluded. The arterial occlusion caused uteroplacental blood flow to fall to 32 +/- 4% and maternal placental blood flow to fall to 25 +/- 3% of control values. This level of asphyxia was maintained for 19 +/- 3 minutes, when maternal and fetal blood flows were measured again. In response to occlusion, fetal ascending aortic PO2 fell from 21 +/- 2 (SEM) to 13 +/- 2 mmHg (P less than or equal to 0.01), oxygen content from 4.3 +/- 0.3 to 1.4 +/- 0.2 mM (P less than or equal to 0.01) and pH from 7.37 +/- 0.01 to 7.21 +/- 0.05 (P less than or equal to 0.01). PCO2 rose from 48 +/- 1 to 62 +/- 3 mmHg (P less than or equal to 0.01). Fetal arterial blood pressure increased from 51 +/- 3 to 61 +/- 3 mmHg (P less than or equal to 0.001) and heart rate decreased from 172 +/- 10 to 104 +/- 4 beats.min-1 (P less than or equal to 0.01). The heart, brain and adrenals showed vasodilation in response to the asphyxic stimulus.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
18.
Cerebral blood flow in the fetal guinea-pig   总被引:1,自引:0,他引:1  
To measure brain blood flow in the fetal guinea-pig, radioactive microspheres were injected in the lateral saphenous vein whilst a reference sample of blood was withdrawn from the right axillary artery. Measurements were made near term of pregnancy, on the 60th-66th day, during anaesthesia with pentobarbitone and diazepam. Fetal blood pressure was 4.25 +/- 0.12 kPa and fetal heart rate was 250 +/- 7 beats per min. The arterial oxygen content varied between 1.9-5.1 mmol 1(-1). Blood flow to the whole brain (mean 1.13 +/- 0.14 ml min-1 g-1) was significantly correlated to the reciprocal of arterial oxygen content (r = 0.84). Four regions of the brain were examined: the cerebral hemispheres, the cerebellum, the thalamus and midbrain, and the pons and medulla. In each region blood flow was inversely related to arterial oxygen content (r = 0.80-0.83) but the rate of perfusion of the brain stem was greater than that of the cerebral hemispheres or cerebellum.  相似文献   

19.
Instantaneous blood flow in the human aorta   总被引:1,自引:0,他引:1  
  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号