首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到13条相似文献,搜索用时 78 毫秒
1.
Taking advantage of the effects on DNA secondary structure of two DNA-intercalators,ethidium bromide and chloroquine,we used each of them to treat nuclei from both mature erythrocytes and reticulocytes of chicken,as an alternative approach to study the relationships between DNA secondary structure,nuclear proteins and chromatin structure.We presented results of differential extraction of nuclear proteins from nuclei with DNA-intercalators,as well as preliminary characterization of these proteins.A 45kd protein is the major component in fractions extracted by both intercalators from nuclei from either mature erythrocytes or reticulocytes and seems to be a DNA-binding protein.Furthermore,from current concepts of functional aspects of DNA conformation and structural heterogeneity in chromatin and nuclear proteins,we have discussed both the significance of our results as well as technical aspects of this approach.  相似文献   

2.
In this study, we directly imaged subnanometer-scale structures of tubulins by performing frequency modulation atomic force microscopy (FM-AFM) in liquid. Individual α-helices at the surface of a tubulin protofilament were imaged as periodic corrugations with a spacing of 0.53 nm, which corresponds to the common pitch of an α-helix backbone (0.54 nm). The identification of individual α-helices allowed us to determine the orientation of the deposited tubulin protofilament. As a result, C-terminal domains of tubulins were identified as protrusions with a height of 0.4 nm from the surface of the tubulin. The imaging mechanism for the observed subnanometer-scale contrasts is discussed in relation to the possible structures of the C-terminal domains. Because the C-terminal domains are chemically modified to regulate the interactions between tubulins and other biomolecules (e.g., motor proteins and microtubule-associated proteins), detailed structural information on individual C-terminal domains is valuable for understanding such regulation mechanisms. The results obtained in this study demonstrate that FM-AFM is capable of visualizing the structural variation of tubulins with subnanometer resolution. This is an important first step toward using FM-AFM to analyze the functions of tubulins.  相似文献   

3.
4.
Zhao H  Zhang Y  Zhang SB  Jiang C  He QY  Li MQ  Qian RL 《Cell research》1999,9(4):255-260
The structure of the nuclosome core particle of chromatin in chicken erythrocytes has been examined by using AFM.The 146 bp of DNA wrapped twice around the core histone octamer are clearly visualized.Both the ends of entry/exit of linker DNA are also demonstrated.The dimension of the nucleosome core particles is - 1-4 nm in height and - 13-22 nm in width.In addition,superbeads (width of - 48-57 nm,height of - 2-3 nm )are occasionally revealed,two turns of DNA around the core particles are also detected.  相似文献   

5.
The pathological changes of erythrocytes are detected at the nanometer scale, which is important for revealing the onset of diseases and diagnosis. The aim of this study is to examine the ultrastructural changes of erythrocytes in Waldenstr6m macroglobulinemia (WM) at a nanometer scale. Blood samples were collected from two healthy volunteers, two WM patients, and three multiple myeloma (MM) patients when they were first diagnosed. The changes of morphology in the erythrocytes were studied at the nanometer level by high-resolution atomic force microscopy imaging (AFM). Compared with the healthy controls and the MM patients, there were dramatic deformations in the overall shape and surface membrane of the erythrocytes in WM patients. Healthy, pathological WM, and MM erythrocytes could be distinguished by several morphological parameters, includ- ing the width, length, length-to-width ratio, valley, peak, peak-to-valley, and Ra. AFM is able to detect the morpho- logical differences in the red blood cells from WM patients, healthy controls, and MM patients. Therefore, the erythro- cyte morphology is an important parameter for the diagnosis of WM, which can be used to distinguish WM from MM. The changes of ultrastructure in red blood cells may provide a clue to reveal the mechanism of WM.  相似文献   

6.
原子力显微镜(AFM)作为一项重要的表面可视化技术,以其独特的优势(纳米级的空间分辨率、皮牛级力灵敏度、免标记、可在溶液环境下工作)被广泛应用于生物被膜的研究。AFM不仅可以在近生理环境下对生物被膜表面超微形貌进行可视化表征,同时还可以通过纳米压痕对生物被膜的机械特性(弹性和粘性)进行定量测量,利用AFM单细胞和单分子力谱技术可以获得生物被膜形成过程中细胞-基底以及细胞-细胞之间的相互作用力,为生物被膜的实时原位系统研究提供了可行性。本文简述了AFM的基本操作原理,综述了近年来AFM用于生物被膜表面超微结构成像、机械特性测量以及相互作用力研究方面的进展,并对AFM在生物被膜研究中面临的问题和未来的发展方向进行了讨论。  相似文献   

7.
原子力显微技术在酶学研究中的应用   总被引:1,自引:0,他引:1  
酶在生物体的生命活动中占有及其重要的地位,机体功能的和谐统一有赖于酶的作用。原子力显微技术(AFM)作为一门新发展起来的技术,为人们认识酶的结构与功能提供了又一新的窗口。AFM能够在生理条件下对生物样品进行三维成像,在分子水平上实时监测生理生化反应。AFM还能够在皮牛顿精度上测定分子间作用力。目前,AFM已用于单分子酶的化学性质及其作用原理的研究。本简述AFM在酶学中的应用情况。  相似文献   

8.
原子力显微镜单分子力谱研究生物分子间相互作用   总被引:2,自引:0,他引:2  
原子力显微镜单分子力谱是近年来发展起来的能在单分子水平研究生物分子相互作用的新工具。本文综述了单分子力谱的测定原理、方法及其在研究蛋白.蛋白、蛋白-DNA相互作用,蛋白质去折叠和活细胞上配体/受体结合中的应用进展。  相似文献   

9.
Atomic force microscopy (AFM) is the type of scanning probe microscopy that is probably best adapted for imaging biological samples in physiological conditions with submolecular lateral and vertical resolution. In addition, AFM is a method of choice to study the mechanical unfolding of proteins or for cellular force spectroscopy. In spite of 28 years of successful use in biological sciences, AFM is far from enjoying the same popularity as electron and fluorescence microscopy. The advent of high-speed atomic force microscopy (HS-AFM), about 10 years ago, has provided unprecedented insights into the dynamics of membrane proteins and molecular machines from the single-molecule to the cellular level. HS-AFM imaging at nanometer-resolution and sub-second frame rate may open novel research fields depicting dynamic events at the single bio-molecule level. As such, HS-AFM is complementary to other structural and cellular biology techniques, and hopefully will gain acceptance from researchers from various fields. In this review we describe some of the most recent reports of dynamic bio-molecular imaging by HS-AFM, as well as the advent of high-speed force spectroscopy (HS-FS) for single protein unfolding.  相似文献   

10.
We have performed a very extensive investigation of chromatin folding in different buffers over a wide range of ionic conditions similar to those found in eukaryotic cells. Our results show that in the presence of physiological concentrations of monovalent cations and/or low concentrations of divalent cations, small chicken erythrocyte chromatin fragments and chromatin from HeLa cells observed by transmission electron microscopy (TEM) show a compact folding, forming circular bodies of approximately 35 nm in diameter that were found previously in our laboratory in studies performed under very limited conditions. Since TEM images are obtained with dehydrated samples, we have performed atomic force microscopy (AFM) experiments to analyze chromatin structure in the presence of solutions containing different cation concentrations. The highly compact circular structures (in which individual nucleosomes are not visible as separated units) produced by small chromatin fragments in interphase ionic conditions observed by AFM are equivalent to the structures observed by TEM with chromatin samples prepared under the same ionic conditions. We have also carried out experiments of sedimentation and trypsin digestion of chromatin fragments; the results obtained confirm our AFM observations. Our results suggest that the compaction of bulk interphase chromatin in solution at room temperature is considerably higher than that generally considered in current literature. The dense chromatin folding observed in this study is consistent with the requirement of compact chromatin structures as starting elements for the building of metaphase chromosomes, but poses a difficult physical problem for gene expression during interphase.  相似文献   

11.
To find out the mechanism of modulating the deformability of erythrocytes with low intensity He-Ne laser action, we studied the effect of low intensity He-Ne laser on the ultrastructure of human erythrocyte membrane. Erythrocytes were treated with free radicals from a Fenton reaction system before exposing them to low intensity He-Ne laser. The ultrastructure of damaged erythrocyte membrane was examined by atomic force microscopy. The results showed that the erythrocyte membrane became very rough and the molecules on the surface of the membrane congregated into particles of different magnitudes sizes after treating with free radicals. Comparing the degree of congregation of the molecular particles in the non-irradiated group and the He-Ne laser irradiated (9 mW and 18 mW) group, we found the average size of molecular particles in the laser irradiated group was smaller than that in the non-irradiated group, indicating that the low intensity laser had repairing function to the damage of erythrocyte membrane produced by the free radicals.  相似文献   

12.
Seven P2X purinergic receptor subunits have been identified: P2X1–P2X7. The overlapping expression of P2X2, P2X4 and P2X6 subunits has been shown in different cell types, and functional analysis of P2X receptors in Leydig cells suggests that the three subunits might interact. Here, His6-tagged P2X2, HA-tagged P2X4 and FLAG-tagged P2X6 subunits were co-expressed in tsA 201 cells. After sequential co-immunoprecipitation using anti-HA and anti-FLAG beads, all three subunits were present, demonstrating their interaction. Atomic force microscopy (AFM) imaging revealed receptors that were specifically decorated by both an anti-His6 antibody and an anti-HA Fab fragment, indicating the presence of a P2X2/4/6 heterotrimer. To our knowledge, this is the first report of a P2X receptor containing three different subunits.  相似文献   

13.
In this article, a technique for accurate direct measurement of protein‐to‐protein interactions before and after the introduction of a drug candidate is developed using atomic force microscopy (AFM). The method is applied to known immunosuppressant drug candidate Echinacea purpurea derived cynarin. T‐cell/CD28 is on‐chip immobilized and B‐cell/CD80 is immobilized on an AFM tip. The difference in unbinding force between these two proteins before and after the introduction of cynarin is measured. The method is described in detail including determination of the loading rates, maximum probability of bindings, and average unbinding forces. At an AFM loading rate of 1.44 × 104 pN/s, binding events were largely reduced from 61 ± 5% to 47 ± 6% after cynarin introduction. Similarly, maximum probability of bindings reduced from 70% to 35% with a blocking effect of about 35% for a fixed contact time of 0.5 s or greater. Furthermore, average unbinding forces were reduced from 61.4 to 38.9 pN with a blocking effect of ~37% as compared with ~9% by SPR. AFM, which can provide accurate quantitative measures, is shown to be a good method for drug screening. The method could be applied to a wider variety of drug candidates with advances in bio‐chip technology and a more comprehensive AFM database of protein‐to‐protein interactions. Biotechnol. Bioeng. 2012; 109: 2460–2467. © 2012 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号