首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Segmented 3-D data of the spine form the basis for various modern clinical applications. Among these, multisegmental image fusion, image registration and finite element modeling for biomechanical analysis are promising innovative tools capable of facilitating treatment decisions and optimization of individual therapy in the future. However, the complex anatomy of the spine and the often extensive degenerative deformation presenting in clinical practice, generally limit the application of fully automated segmentation. A newly developed software system is presented that meets the complex requirements for image segmentation of the spine through the use of specially adapted interactive tools that take account of its axial skeletal structure. Furthermore, a standardized protocol is introduced that combines the newly developed interactive tools (rotation transformation, warped dissection plane) and standard segmentation tools to permit rapid and accurate segmentation. To date, the software environment presented herein has been applied with success to the segmentation of cervical, thoracic and lumbar spine.  相似文献   

2.
In this study we investigate the use of splines and the ICP method [Besl, P., McKay, N., 1992. A method for registration of 3d shapes. IEEE Transactions on Pattern Analysis and Machine Intelligence 14, 239-256.] for calculating the transformation parameters for a rigid body undergoing planar motion parallel to the image plane. We demonstrate the efficacy of the method by estimating the finite centre of rotation and angle of rotation from lateral flexion/extension radiographs of the lumbar spine. In an in vitro error study, the method displayed an average error of rotation of 0.44 +/- 0.45 degrees, and an average error in FCR calculation of 7.6 +/- 8.5 mm. The method was shown to be superior to that of Crisco et al. [Two-dimensional rigid-body kinematics using image contour registration. Journal of Biomechanics 28(1), 119-124.] and Brinckmann et al. [Quantification of overload injuries of the thoracolumbar spine in persons exposed to heavy physical exertions or vibration at the workplace: Part i - the shape of vertebrae and intervertebral discs - study of a yound, healthy population and a middle-aged control group. Clinical Biomechanics Supplement 1, S5-S83.] for the tests performed here. In general, we believe the use of splines to represent planar shapes to be superior to using digitised curves or landmarks for several reasons. First, with appropriate software, splines require less effort to define and are a compact representation, with most vertebra outlines using less than 30 control points. Second, splines are inherently sub-pixel representations of curves, even if the control points are limited to pixel resolutions. Third, there is a well-defined method (the ICP algorithm) for registering shapes represented as splines. Finally, like digitised curves, splines are able to represent a large class of shapes with little effort, but reduce potential segmentation errors from two dimensions (parallel and perpendicular to the image gradient) to just one (parallel to the image gradient). We have developed an application for performing all the necessary computations which can be downloaded from http://www.claritysmart.com.  相似文献   

3.
4.
Geometry and respiratory displacement of human ribs   总被引:2,自引:0,他引:2  
The three-dimensional coordinates of points in the ribs of two supine relaxed males, holding their breath at functional residual capacity (FRC) and with their glottis closed at total lung capacity (TLC), were obtained from volumetric X-ray computed tomographical images. The orientation of planes that best fit the data for each rib at each lung volume and the circular arcs that fit the points in the planes of the ribs were determined, and average values of these geometrical parameters for ribs 3-7 are reported. The planes of the ribs at TLC can be described as displaced from the planes at FRC by a rotation about an axis that passes near the spine. The pump handle and bucket handle components of rotation are 11 and 13 degrees, respectively, for rib 3 and both decrease with increasing rib number to 7 and 10 degrees at rib 7. The angles between the axes of rotation and the midplane are approximately 35 degrees for all 5 ribs. The radii of the circular arcs fit to the data at TLC are slightly larger than those at FRC, and this suggests that there is a small component of rotation normal to the plane of the rib.  相似文献   

5.
Scoliosis is a deformity characterized by lateral curvature of the spine and accompanied by axial rotation of the vertebrae; it often causes varying degrees of trunk deformity. Research has indicated that topographic techniques can be used to describe the disorder and monitor its progression. A video image acquisition system has been designed which reduces the time required to quantify topographic details of the trunk and aids in the diagnosis, monitoring and research of scoliosis. This system integrates the capability of large, expensive grey-scale image acquisition equipment into a small, low-cost diagnostic imaging tool using current technologies and design techniques. The video digitizer accepts a standard NTSC monochromatic video signal as input and the unit is connected to a computer via an EEE-488 bus from which the ditigizer is controlled. The digitizer samples the video signal in real time using a high-speed flash converter controlled by an application-specific integrated circuit; the digital samples are stored in memory until the host computer requests that the information be transferred.  相似文献   

6.
The helical axis model can be used to describe translation and rotation of spine segments. The aim of this study was to investigate the cervical helical axis and its center of rotation during fast head movements (side rotation and flexion/extension) and ball catching in patients with non-specific neck pain or pain due to whiplash injury as compared with matched controls. The aim was also to investigate correlations with neck pain intensity. A finite helical axis model with a time-varying window was used. The intersection point of the axis during different movement conditions was calculated. A repeated-measures ANOVA model was used to investigate the cervical helical axis and its rotation center for consecutive levels of 15 degrees during head movement. Irregularities in axis movement were derived using a zero-crossing approach. In addition, head, arm and upper body range of motion and velocity were observed. A general increase of axis irregularity that correlated to pain intensity was observed in the whiplash group. The rotation center was superiorly displaced in the non-specific neck pain group during side rotation, with the same tendency for the whiplash group. During ball catching, an anterior displacement (and a tendency to an inferior displacement) of the center of rotation and slower and more restricted upper body movements implied a changed movement strategy in neck pain patients, possibly as an attempt to stabilize the cervical spine during head movement.  相似文献   

7.
8.
Prior studies have found that primary rotations in the lumbar spine are accompanied by coupled out-of-plane rotations. However, it is not clear whether these accompanying rotations are primarily due to passive (discs, ligaments and facet joints) or active (muscles) spinal anatomy. The aim of this study was to use a finite element (FE) model of the lumbar spine to predict three-dimensional coupled rotations between the lumbar vertebrae, due to passive spinal structures alone. The FE model was subjected to physiologically observed whole lumbar spine rotations about in vivo centres of rotation. Model predictions were validated by comparison of intra-discal pressures and primary rotations with in vivo measurements and these showed close agreement. Predicted coupled rotations matched in vivo measurements for all primary motions except lateral bending. We suggest that coupled rotations accompanying primary motions in the sagittal (flexion/extension) and transverse (axial rotation) planes are primarily due to passive spinal structures. For lateral bending the muscles most likely play a key role in the coupled rotation of the spine.  相似文献   

9.
Although muscles are assumed to be capable of stabilizing the spinal column in vivo, they have only rarely been simulated in vitro. Their effect might be of particular importance in unstable segments. The present study therefore tests the hypothesis that mechanically simulated muscle forces stabilize intact and injured cervical spine specimens. In the first step, six human occipito-cervical spine specimens were loaded intact in a spine tester with pure moments in lateral bending (+/- 1.5 N m), flexion-extension (+/- 1.5 N m) and axial rotation (+/- 0.5 N m). In the second step, identical flexibility tests were carried out during constant traction of three mechanically simulated muscle pairs: splenius capitits (5 N), semispinalis capitis (5 N) and longus colli (15 N). Both steps were repeated after unilateral and bilateral transection of the alar ligaments. The muscle forces strongly stabilized C0-C2 in all loading and injury states. This was most obvious in axial rotation, where a reduction of range of motion (ROM) and neutral zone to <50% (without muscles=100%) was observed. With increasing injury the normalized ROM (intact condition=100%) increased with and without muscles approximately to the same extend. With bilateral injury this increase was 125-132% in lateral bending, 112%-119% in flexion-extension and 103-116% in axial rotation. Mechanically simulated cervical spine muscles strongly stabilized intact and injured cervical spine specimens. Nevertheless, it could be shown that in vitro flexibility tests without muscle force simulation do not necessarily lead to an overestimation of spinal instability if the results are normalized to the intact state.  相似文献   

10.
Multisegmental biomechanical studies on the lumbar spine are steadily increasing in importance. Only in this way can we acquire knowledge about the physiological behaviour of the entire lumbar spine. Furthermore, these studies allow us to analyse in vitro the biomechanics of manipulated lumbar spines after various surgical operations on the spine. A load simulator was developed to investigate multisegmental lumbar spine mobility, and its function was investigated in an initial study on 19 fresh--frozen specimens of human lumbar spine. After x-ray examination and determination of the bone mineral density, the specimens were loaded up to 10 Nm in the automatic electromechanical loading system under flexion/extension, lateral bending and axial rotation. An ultrasound-based motion analysis system was used to measure the displacements of the vertebrae involved.  相似文献   

11.
Moment arms of the human neck muscles in flexion, bending and rotation   总被引:1,自引:0,他引:1  
There is a paucity of data available for the moment arms of the muscles of the human neck. The objective of the present study was to measure the moment arms of the major cervical spine muscles in vitro. Experiments were performed on five fresh-frozen human head-neck specimens using a custom-designed robotic spine testing apparatus. The testing apparatus replicated flexion-extension, lateral bending and axial rotation of each individual intervertebral joint in the cervical spine while all other joints were kept immobile. The tendon excursion method was used to measure the moment arms of 30 muscle sub-regions involving 13 major muscles of the neck about all three axes of rotation of each joint for the neutral position of the cervical spine. Significant differences in the moment arm were observed across sub-regions of individual muscles and across the intervertebral joints spanned by each muscle (p<0.05). Overall, muscle moment arms were larger in flexion-extension and lateral bending than in axial rotation, and most muscles had prominent moment arms in at least 2 out of the 3 joint motions investigated. This study emphasizes the importance of detailed representation of a muscle's architecture in prediction of its torque capacity about the individual joints of the cervical spine. The dataset produced may be useful in developing and validating computational models of the human neck.  相似文献   

12.
A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending with the inferior surface of the C7 vertebral body fully constrained were analysed. The predicted range of motion (ROM) for each motion segment were computed and compared with published experimental data. The model predicted the nonlinear moment-rotation relationship of human cervical spine. Under the same loading magnitude, the model predicted the largest rotation in extension, followed by flexion and axial rotation, and least ROM in lateral bending. The upper cervical spines are more flexible than the lower cervical levels. The motions of the two uppermost motion segments account for half (or even higher) of the whole cervical spine motion under rotational loadings. The differences in the ROMs among the lower cervical spines (C3-C7) were relatively small. The FE predicted segmental motions effectively reflect the behavior of human cervical spine and were in agreement with the experimental data. The C0-C7 FE model offers potentials for biomedical and injury studies.  相似文献   

13.
The study was based on the angiographic examination of 233 patients with prior subarachnoidal hemorrhage. Angiographic study was performed using the Seldinger technique by contrasting both carotid and vertebral arteries. Twenty-three patients in whom arterial aneurysm had been detected by digital subtraction angiography underwent 3D angiography. The authors improved a procedure during which a contrast agent was manually injected into the internal carotid or vertebral artery, by using a 20-ml disposal syringe with controlled maximum developed pressure and flow increase rate up to 2.0 ml/sec for 4-5 sec during rotary scanning and the administration of the radiocontrast medium was stopped when an image appeared on the monitor at 190 degrees (190.0, 200.0) C-arm rotation. This procedure could decrease significantly the volume of the administered contrast agent from 18 to 8 (8.0, 10.0) ml and reduce the time of radiation exposure from 6 to 4 (4.0, 5.0) sec. The improved angiographic modes for the right vertebral and right carotid artery could visualize pathological changes in these arteries and establish a relationship, namely: due to degenerative dystrophic processes of the cervical spine there is a tendency for higher pathological changes in the vertebral arteries with an increased stage of osteochondrosis in the cervical spine (R = 0.95; p = 0.014).  相似文献   

14.
Animals are becoming more and more common as in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examinations human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or polymethylmethacrylate (PMMA) after discectomy. Following our first experience with the use of the new material and its influence on the primary stability after in vitro application we carried out fusions of 20 sheep cervical spines levels with either PMMA or an Ecopore-cage, and performed radiological examinations during the following 2-4 months. In this second part of the study we intended the biomechanical evaluation of the spine segments with reference to the previously determined morphological findings, like subsidence of the implants, significant increase of the kyphosis angle and degree of the bony fusion along with the interpretation of the results. 20 sheep cervical spines segments with either PMMA- or Ecopore-fusion in the levels C2/3 and C4/5 were tested, in comparison to 10 native corresponding sheep cervical spine segments. Non-destructive biomechanical testing was performed, including flexion/extension, lateral bending and axial rotation using a spine testing apparatus. Three-dimensional range of motion (ROM) was evaluated using an ultrasound measurement system. In the native spine segments C2/3 and C4/5 the ROM increased in cranio-caudal direction particulary in flexion/extension, less pronounced in lateral flexion and axial rotation (p < 0.05). The overall ROM of both tested segments was greatest in lateral flexion, reduced to 52% in flexion/extension and to 16% in axial rotation. After 2 months C2/3- and C4/5-segments with PMMA-fusion and C2/3-segments with Ecopore-interposition showed decrease of ROM in lateral flexion in comparison to the native segments, indicating increasing stiffening. However, after 4 months all operated segments, independent from level or implanted material, were stiffer than the comparable native segments. The decrease of the ROM correlated with the radiological-morphological degree of fusion. Our evaluation of the new porous TiO2/glass composite as interbody fusion cage has shown satisfactory radiological results as well as distinct biomechanical stability and fusion of the segments after 4 months in comparison to PMMA. After histological analysis of the bone-biomaterial-interface, further examinations of this biomaterial previous to an application as alternative to other customary cages in humans are necessary.  相似文献   

15.
This study evaluated between-session reliability of opto-electronic motion capture to measure trunk posture and three-dimensional ranges of motion (ROM). Nineteen healthy participants aged 24–74 years underwent spine curvature, pelvic tilt and trunk ROM measurements on two separate occasions. Rigid four-marker clusters were attached to the skin overlying seven spinous processes, plus single markers on pelvis landmarks. Rigid body rotations of spine marker clusters were calculated to determine neutral posture and ROM in flexion, extension, total lateral bending (left-right) and total axial rotation (left-right). Segmental spine ROM values were in line with previous reports using opto-electronic motion capture. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated as measures of between-session reliability and measurement error, respectively. Retroreflective markers showed fair to excellent between-session reliability to measure thoracic kyphosis, lumbar lordosis, and pelvic tilt (ICC = 0.82, 0.63, and 0.54, respectively). Thoracic and lumbar segments showed highest reliabilities in total axial rotation (ICC = 0.78) and flexion-extension (ICC = 0.77–0.79) ROM, respectively. Pelvic segment showed highest ICC values in flexion (ICC = 0.78) and total axial rotation (ICC = 0.81) trials. Furthermore, it was estimated that four or fewer repeated trials would provide good reliability for key ROM outcomes, including lumbar flexion, thoracic and lumbar lateral bending, and thoracic axial rotation. This demonstration of reliability is a necessary precursor to quantifying spine kinematics in clinical studies, including assessing changes due to clinical treatment or disease progression.  相似文献   

16.
The effects of the rib cage on thoracic spine loading are not well studied, but the rib cage may provide stability or share loads with the spine. Intervertebral disc pressure provides insight into spinal loading, but such measurements are lacking in the thoracic spine. Thus, our objective was to examine thoracic intradiscal pressures under applied pure moments, and to determine the effect of the rib cage on these pressures. Human cadaveric thoracic spine specimens were positioned upright in a testing machine, and Dynamic pure moments (0 to ±5 N·m) with a compressive follower load of 400 N were applied in axial rotation, flexion - extension, and lateral bending. Disc pressures were measured at T4-T5 and T8-T9 using needle-mounted pressure transducers, first with the rib cage intact, and again after the rib cage was removed. Changes in pressure vs. moment slopes with rib cage removal were examined. Pressure generally increased with applied moments, and pressure-moment slope increased with rib cage removal at T4-T5 for axial rotation, extension, and lateral bending, and at T8-T9 for axial rotation. The results suggest the intact rib cage carried about 62% and 56% of axial rotation moments about T4-T5 and T8-T9, respectively, as well as 42% of extension moment and 36–43% of lateral bending moment about T4-T5 only. The rib cage likely plays a larger role in supporting moments than compressive loads, and may also play a larger role in the upper thorax than the lower thorax.  相似文献   

17.
The kinematic function of the cervical spine has been examined previously by means of cineradiography or a sequence of lateral X-rays, usually of a flexion-extension range of motion. Interpretation of these studies, however, presents difficulties. One of the major problems is how to extract information from the X-ray images which is not only explicit, quantitative and accurate, but which is also diagnostically useful. Another problem is that as one increases the number of steps of motion between full flexion and full extension to obtain a more detailed examination, one also increases the amount of radiation exposure and the bulk of the data.

Reported here is a technique which uses one lateral-view X-ray for each of five neck positions: full flexion, full extension, and three intermediate positions. From each set of X-rays, various parameters are derived to describe two types of data: kinematic (angles and centers of rotation), and geometric (pattern of curvature). This technique has been shown capable of identifying functional abnormalities in patients with neck pain who have no structural abnormalities detectable by X-ray. Further experience will be useful in better defining various types of functional abnormalities.  相似文献   


18.
Clinical theory suggests that altered alignment of the shoulder girdle has the potential to create or sustain symptomatic mechanical dysfunction in the cervical and thoracic spine. The alignment of the shoulder girdle is described by two clavicle rotations, i.e, elevation and retraction, and by three scapular rotations, i.e., upward rotation, internal rotation, and anterior tilt. Elevation and retraction have until now been assessed only in patients with neck pain. The aim of the study was to determine whether there is a pattern of altered alignment of the shoulder girdle and the cervical and thoracic spine in patients with neck pain. A three-dimensional device measured clavicle and scapular orientation, and cervical and thoracic alignment in patients with insidious onset neck pain (IONP) and whiplash-associated disorder (WAD). An asymptomatic control group was selected for baseline measurements. The symptomatic groups revealed a significantly reduced clavicle retraction and scapular upward rotation as well as decreased cranial angle. A difference was found between the symptomatic groups on the left side, whereas the WAD group revealed an increased scapular anterior tilt and the IONP group a decreased clavicle elevation. These changes may be an important mechanism for maintenance and recurrence or exacerbation of symptoms in patients with neck pain.  相似文献   

19.
This was an in vitro and in vivo study to develop a novel artificial cervical vertebra and intervertebral complex (ACVC) joint in a goat model to provide a new method for treating degenerative disc disease in the cervical spine. The objectives of this study were to test the safety, validity, and effectiveness of ACVC by goat model and to provide preclinical data for a clinical trial in humans in future. We designed the ACVC based on the radiological and anatomical data on goat and human cervical spines, established an animal model by implanting the ACVC into goat cervical spines in vitro prior to in vivo implantation through the anterior approach, and evaluated clinical, radiological, biomechanical parameters after implantation. The X-ray radiological data revealed similarities between goat and human intervertebral angles at the levels of C2-3, C3-4, and C4-5, and between goat and human lordosis angles at the levels of C3-4 and C4-5. In the in vivo implantation, the goats successfully endured the entire experimental procedure and recovered well after the surgery. The radiological results showed that there was no dislocation of the ACVC and that the ACVC successfully restored the intervertebral disc height after the surgery. The biomechanical data showed that there was no significant difference in range of motion (ROM) or neural zone (NZ) between the control group and the ACVC group in flexion-extension and lateral bending before or after the fatigue test. The ROM and NZ of the ACVC group were greater than those of the control group for rotation. In conclusion, the goat provides an excellent animal model for the biomechanical study of the cervical spine. The ACVC is able to provide instant stability after surgery and to preserve normal motion in the cervical spine.  相似文献   

20.
Although the morphology of the tibial plateau in primates has received very little attention in the literature, it does exhibit features of phylogenetic and functional interest. This paper describes the morphology of the tibial plateau (particularly the intercondylar region) in extant and fossil primates, and in three mammalian outgroups: the pen-tailed tree shrew (Ptilocercus), tree shrew (Tupaia), and flying lemur or dermopteran (Cynocephalus). Extant and fossil strepsirrhine primates exhibit an eminence with a single spine, which contrasts with the intercondylar morphology of haplorhine primates. Most extant platyrrhines, all catarrhine primates (including humans), and some fossil haplorhines possess an eminence with two spines (medial and lateral) connected by a ridge of bone that intersects the intercondylar groove. Tarsius and callitrichines possess an eminence with a reduced medial spine that superficially resembles that of strepsirrhine primates. Dermopterans also exhibit a morphology similar to that of strepsirrhines. In Scandentia, the intercondylar morphology of Tupaia is similar to that of rodents, whereas Ptilocercus resembles tarsiers and callitrichines. We hypothesize that proximal tibiae with either a single spine or reduced medial spine morphology facilitate a greater degree of knee rotation about the eminence relative to the double-spine condition, and are likely associated with more frequent adoption of vertical body positions. In contrast, a double-spine eminence limits knee rotation and is probably associated with greater use of horizontal supports. Although the polarity is complicated by the unknown phylogenetic status of likely sister taxa, it seems most probable that the single-spine morphology is a derived feature of strepsirrhines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号