首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We previously discovered that squalene monohydroperoxide (SQ-OOH) was produced on human forehead skin and suggested that skin squalene (SQ) may be the principal target lipid for oxidative stress (e.g., sunlight exposure). Because of its six double bonds, SQ peroxidation can yield various positional hydroperoxide isomers. However, the structural characterization of skin SQ-OOH isomers has never been reported. Here, we prepared pure SQ-OOH isomers and developed an analytical method for SQ-OOH isomers using a quadrupole/linear ion-trap mass spectrometer (QTRAP) MS/MS system. Collision-induced dissociation produced specific fragment ions for each SQ-OOH isomer, which permitted discrimination between SQ-OOH isomers by multiple reaction monitoring (MRM). When lipid extract from human forehead skin was subjected to LC-MS/MS with MRM, individual SQ-OOH isomers could be separated and detected with a sensitivity of 0.05 ng/injection. The total concentration of SQ-OOH isomers in forehead skin was approximately 956 microg/g skin lipids, but it increased up to 2,760 microg/g skin lipids after 3 h of sunlight exposure. The LC-MS/MS method was useful for investigating the peroxidation mechanisms of SQ as well as SQ-OOH-mediated skin disorders.  相似文献   

2.
An amino group of phosphatidylethanolamine (PE) is considered as a target for nonenzymatic glycation, and the potential involvement of lipid glycation in the pathogenesis of diabetic complications has generated interest. However, unlike an early glycation product of PE (Amadori-PE), the occurrence and roles of advanced glycation end products of PE (AGE-PE) in vivo have been unclear. Here, we developed an LC-MS/MS method for the analysis of AGE-PE [carboxymethyl-PE (CM-PE) and carboxyethyl-PE (CE-PE)]. Collision-induced dissociation of CM-PE and CE-PE produced characteristic ions, permitting neutral loss scanning (NLS) and multiple reaction monitoring (MRM) of AGE-PE. By NLS analysis, a series of AGE-PE molecular species was detected in human erythrocytes and blood plasma. In LC-MS/MS analysis, MRM enabled the separation and determination of the predominant AGE-PE species. Between healthy subjects and diabetic patients, no significant differences were observed in AGE-PE concentrations in erythrocytes and plasma, whereas Amadori-PE concentrations were higher in diabetic patients. These results provide direct evidence for the presence of AGE-PE in human blood, and indicated that, compared with Amadori-PE, AGE-PE is less likely to be accumulated in diabetic blood. The presently developed LC-MS/MS method appears to be a powerful tool for understanding in vivo lipid glycation and its pathophysiological consequence.  相似文献   

3.
Succinoglycan monomers (M1, M2, and M3) are octasaccharides with acetyl, pyruvyl, and/or succinyl groups as substituents derived from Sinorhizobium meliloti 1021. The dissociation patterns of the octasaccharides caused by low-energy collision-activated dissociation (CAD) were investigated using triple quadrupole tandem mass spectrometry (MS) equipped with an electrospray ionization (ESI) source with increasing collision energy (CE) in negative ion mode. None of the succinoglycan monomers were fragmented at a CE of −25 eV. When the CE was applied to −50 or −70 eV, the loss of the terminal Gal residue and/or the succinyl group of the monomers was observed in the product ion scan mode. Interestingly, the acetyl and the pyruvyl groups in the succinoglycan monomers were not lost even when a CE of −70 eV was applied, indicating that the substituents are more stable than the succinyl group in the octasaccharides.  相似文献   

4.
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc.  相似文献   

5.
A confirmatory and quantitative HPLC-tandem mass spectrometry (MS-MS) method for human chorionic gonadotropin hormone (hCG) at concentrations as low as 5 IU/l following immunoaffinity extraction of the glycoprotein from urine was developed. The extraction method involved retention of urinary hCG in the immunoaffinity column via specific antigen-antibody interaction. A variety of eluents were then used to quantitatively elute hCG from the immunoaffinity column. Qualitative and quantitative analysis of hCG were undertaken using MS-MS by identifying the amino acid sequence of the marker peptide betaT5 obtained from hCG by tryptic digestion and the peak areas of three product ions b(6)(+), b(9)(+) and y(11)(+), respectively.  相似文献   

6.
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the simultaneous analysis of hydrocodone (HYC) and its metabolite hydromorphone (HYM) in human plasma. A robotic liquid handler and a 96-channel liquid handling workstation were used to aliquot samples, to add internal standard (I.S.), and to extract analytes of interest. A 96-well mixed-mode solid-phase cartridge plate was used to extract the analytes and I.S. The chromatographic separation was on a silica column (50 x 3 mm, 5-microm) with a mobile phase consisting of acetonitrile, water and trifluoroacetic acid (TFA) (92:8:0.01, v/v). The run time for each injection was 2.5 min with the retention times of approximately 2.1 and 2.2 min for HYC and HYM, respectively. The tandem mass spectrometric detection was by monitoring singly charged precursor-->product ion transition 300-->199 (m/z) for HYC, and 28-->185 (m/z) for HYM. The validated calibration curve range was 0.100-100 ng/ml, based on a plasma volume of 0.3 ml. The correlation coefficients were greater than or equal to 0.9996 for both HYC and HYM. The low limit of quantitation (LLOQ) was 0.100 ng/ml for both HYC and HYM with signal-to-noise ratio (S/N) of 50 and 10. respectively. The deuterated analytes, used as internal standards, were monitored at mass transitions 303-->199 (m/z) for HYC-d3 and 289-->185 (m/z) for HYM-d3. The inter-day (n= 17) precision of the quality control (QC) samples were < or = 3.5% RSD (relative standard deviation) for HYC and < or = 4.7% RSD for HYM, respectively. The inter-day accuracy of the QC samples were < or = 2.1% RE (relative error) for HYC and < or = 1.8% RE for HYM. The intra-day (n=6) precision and accuracy of the QC samples were < or = 2.6% RSD and < or = 3.0% RE for HYC, and < or = 4.7% RSD and < or = 2.4% RE for HYM. There was no significant deviation from the nominal values after a 5-fold dilution of high concentration QC samples by blank matrix. The QC samples were stable when kept at room temperature for 24-h or experienced three freeze-thaw cycles. The extraction recoveries were 86% for HYC and 78% for HYM. No detectable carryover was observed when a blank sample was injected immediately after a 2500 ng/ml sample that was 25-fold more concentrated than the upper limit of quantitation (ULOQ).  相似文献   

7.
An electrospray mass spectrometric method for the quantification of the depolarizing neuromuscular blocking agent succinylcholine (SUX) is described. An extraction method compatible with direct infusion inlet was developed and leads to an analysis cycle time of 7--8 min instead of 25 min that would be required for HPLC inlet. SUX was extracted from human plasma on C1 solid-phase cartridges and was analyzed using positive ion electrospray tandem mass spectrometry (ESI-MS/MS). SUX plasma concentrations were determined by a stable isotope dilution assay using hexadeuterosuccinylcholine diiodide (SUXd6) as the internal standard. The calibration curve was prepared using the ratio of intensities of the major product ions in the collision-induced dissociation spectrum for known concentration ratios of SUX and SUXd6 in plasma. Calibration curves for the quantification were linear from 25 to 4000 ng/ml. For intraday precision, CV were < or =6% and accuracy ranged from 98 to 103%. For the interday precision, CV were < or =10% and accuracy ranged from 90 to 102%. This method is specific, sensitive, reproducible, and practical in a clinical setting.  相似文献   

8.
An assay employing automated solid-phase extraction (SPE) followed by high-performance liquid chromatography with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS) was developed and validated for the quantification of rosuvastatin (Crestor) in human plasma. Rosuvastatin is a hydroxy-methyl glutaryl coenzyme A reductase inhibitor currently under development by AstraZeneca. The standard curve range in human plasma was 0.1-30 ng/ml with a lower limit of quantification (LLOQ) verified at 0.1 ng/ml. Inaccuracy was less than 8% and imprecision less than +/-15% at all concentration levels. There was no interference from endogenous substances. The analyte was stable in human plasma following three freeze/thaw cycles and for up to 6 months following storage at both -20 and -70 degrees C. The assay was successfully applied to the analysis of rosuvastatin in human plasma samples derived from clinical trials, allowing the pharmacokinetics of the compound to be determined.  相似文献   

9.
The dynamics of the anaerobic conversion of formate in a microbial mixed culture taken from an anaerobic fluidized bed reactor was studied using a new stirred micro reactor equipped with a membrane mass spectrometer. The microreactor with a toroidally shaped bottom and pitched blade turbine and a cylindrical flow guide was thermostated and additionally equipped with a pH electrode and pH control. During fed-batch experiments using formate, the dissolved gases (methane, hydrogen, and carbon dioxide), as well as the acid consumption rates for pH control were monitored continuously. Initially and at the end of each experiment, organic acids were analyzed using ion chromatography (IC). It was found that about 50% of the formate was converted to methane via hydrogen and carbon dioxide, 40% gave methane either directly or via acetate. This was calculated from experiments using H(13)CO(3) (-) pulses and measurement of (12)CH(4) and (13)CH(4) production rates. About 10% of the formate was converted to lactate, acetate, and propionate, thereby increasing the measured CO(2)/CH(4) production ratio. The nondissociated formic acid was shown to be rate determining. From the relatively high K(s) value of 2.5 mmol m(-3), it was concluded that formate cannot play an important role in electron transfer. During dynamic feeding of formate, hydrogen concentration always increased to a maximum before decreasing again. This peak was found to be very discriminative during modeling. From the various models set up, only those with two-stage degradation and double Monod kinetics, both for CO(2) and hydrogen, were able to describe the experimental data adequately. Additional discrimination was possible with the IC measurement of organic acids. (c) 1995 John Wiley & Sons, Inc.  相似文献   

10.
A sensitive and specific LC–MS–MS assay has been developed and validated for barnidipine (1-benzyl-3-pyrrolidinyl)methyl-2,6-dimethyl-4(m-nitrophenyl)-1,4-dihydropyridine-3,5-dicarboxylate). The assay involves a simple and rapid solid-phase extraction procedure. Sample analysis was on a Spherisorb S3ODS2 100 mm×2 mm I.D. column, with a Finnigan TSQ 7000 mass spectrometer, using an electrospray interface and selective reaction monitoring (SRM). The intra- and inter-day precision and accuracy, determined as the coefficient of variation and relative error, respectively, were 11.8% or less. The limit of quantitation was 0.03 ng/ml, and the calibration was linear between 0.03 and 3.0 ng/ml. The method has been used successfully for the measurement of over two thousand human plasma samples from pharmacokinetic clinical trials.  相似文献   

11.
Proteomics can be thought of as an attempt to understand the information encoded in genomic sequences from the perspective of proteins; i.e. the structure, function and regulation of biological processes at the protein level. In practice it stands in stark contrast to the hypothesis-driven serial approach practiced in the last century that was so successful for protein chemists and is built on the basic understanding of protein physicochemical properties developed during that era. Proteomics attempts to study biological processes comprehensively or globally by systematic parallel analysis of proteins expressed in a cell. While there are many analytical techniques in use and under development in proteomics, mass spectrometry is currently one of the field's most important discovery-based tools. This article will review some of the current approaches for qualitative and quantitative uses of tandem mass spectrometry in the field of proteomics specifically avoiding a discussion of the use of gel electrophoresis prior to mass spectrometry. Electronic Publication  相似文献   

12.
In this study, we present a preprocessing method for quadrupole time-of-flight (Q-TOF) tandem mass spectra to increase the accuracy of database searching for peptide (protein) identification. Based on the natural isotopic information inherent in tandem mass spectra, we construct a decision tree after feature selection to classify the noise and ion peaks in tandem spectra. Furthermore, we recognize overlapping peaks to find the monoisotopic masses of ions for the following identification process. The experimental results show that this preprocessing method increases the search speed and the reliability of peptide identification.  相似文献   

13.
Mulberry 1-deoxynojirimycin (DNJ) is a potent alpha-glucosidase inhibitor. Although it is useful for the treatment of diabetes, the human absorption and metabolism of DNJ have never been characterized. We developed a method using hydrophilic interaction chromatography coupled with ion trap tandem mass spectrometry, and found that orally administered DNJ was absorbed into the blood and then excreted into the urine.  相似文献   

14.
An HPLC-MS/MS assay for the determination of an HIV integrase inhibitor, 5-(1,1-dioxido-1,2-thiazinan-2-yl)-N-(4-fluorobenzyl)-8-hydroxy-1,6-naphthyridine-7-carboxamide (I) in human plasma has been developed and validated. Compound I and a stable isotope labeled internal standard (II) were isolated from 0.5 mL plasma samples by solid phase extraction using an Ansys SPEC C-8 96-well plate. Extracts were separated on a Hypersil BDS C-18 HPLC column (3.0 mmx50 mm, 3 microm) with a mobile phase consisting of 25 mM ammonium formate pH 3.0:acetonitrile (60:40) vol%/vol% pumped at 0.5 mL/min. A Sciex API 365 mass spectrometer equipped with an atmospheric pressure chemical ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 431-->109 (I) and m/z 437-->115 (II) used for quantitation. The assay was validated over the concentration range of 10-5000 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was 69%. The intra-day accuracy of the assay was within 4% of nominal and intra-day precision was better than 4% C.V. Following a 200 mg dose of the compound administered to human subjects, concentrations of I ranged from 21.1 to 1500 ng/mL in plasma samples collected up to 12 h after dosing. Inter-day accuracy and precision results for quality control samples run over a 3-month period alongside clinical samples showed mean accuracies of within 6% of nominal and precision better than 3.5% C.V.  相似文献   

15.
An LC-MS/MS method was developed to quantitate the potential antitumor agent halofuginone in plasma. The assay uses 0.2 ml of plasma; chlorohalofuginone internal standard; acetonitrile for protein precipitation; a Phenomenex SYNERGI 4 micro Polar RP 80A (4 microm, 100 mm x 2 mm) column; an isocratic mobile phase of methanol:water:formic acid (80:20:0.02, v/v/v); and positive-ion electrospray ionization with selective reaction monitoring detection. Halofuginone eluted at approximately 2.4 min, internal standard eluted at approximately 2.9 min, and no endogenous materials interfered with their measurement. The assay was accurate, precise, and linear between 0.1 and 100 ng/ml. Halofuginone could be quantitated in dog plasma for at least 24 h after an i.v. dose of 0.1mg/kg. The assay is being used in ongoing pharmacokinetic studies of halofuginone.  相似文献   

16.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin).  相似文献   

17.
Oligosaccharides from hyaluronic acid and chondroitin 6-sulfate were prepared by digestion with testicular hyaluronidase and separated according to their degree of polymerization by gel-permeation chromatography. These materials were successively analyzed by negative-mode ion-spray mass spectrometry with an atmospheric-pressure ion source. An ion-spray interface was used to produce ions via the ion evaporation process, producing mass spectra containing a series of molecular species carrying multiple charges. Using two adjacent multiply charged molecular ions, the exact molecular weights up to the tetradecasaccharide were calculated with a precision of ±1 dalton. This type of mass spectrometry was also demonstrated to be feasible for the analysis of mixtures of oligosaccharides, including tetra-, hexa-, octa- and decasaccharides, from hyaluronic acid or chondroitin 6-sulfate without separation. Ion-spray mass spectrometry was thus shown to be applicable to the structural analysis of oligosaccharides from glycosaminoglycans.Abbreviations HA hyaluronic acid - Ch6S chondroitin 6-sulfate - GAG glycosaminoglycan - GlcA d-glucuronic acid - GlcNAc 2-acetamido-2-deoxy-d-glucose - GalNAc 2-acetamido-2-deoxy-d-galactose.  相似文献   

18.
A specific and sensitive methodology for the quantitative determination of hydroxysteroids dehydroepiandrosterone and pregnenolone and their main metabolites in human plasma is described. Hydroxysteroids were extracted using methanol and steroids were further separated by reverse-phase high-performance liquid chromatography, allowing for minimization of the possible chromatographic interferences. Eluted fractions were collected, pooled, and analyzed by gas chromatography-mass spectrometry as trimethylsilyl ether derivatives. The quantification was performed with single-ion monitoring of the highly abundant m/z 129 or m/z 358 fragments. The combination of the chromatographic characteristics to the specific fragments ensured the selectivity and specificity of the method. Under these conditions the method was linear (typical R2 is superior to 0.98 for all hydroxysteroids studied) over the concentration range of 2 x 10(-9) to 10(-6)M with good precision and accuracy.  相似文献   

19.
Oxidative damage accumulation in macromolecules has been considered as a cause of cellular damage and pathology. Rarely, the oxidative stress parameters in healthy humans related to the individual age have been reported. The purpose of this study was to examine the redox status in plasma and erythrocytes of healthy individuals and determine correlations between these parameters and the aging process. The following parameters were used: malondialdehyde (MDA), protein carbonyls (PCO), 4-hydroxy-2,3-trans-nonenal (HNE), reduced glutathione (GSH), glutathione disulfide (GSSG) and uric acid (UA) in blood and plasma samples of 194 healthy women and men of ages ranging from 18 to 84 years. The results indicate that the balance of oxidant and antioxidant systems in plasma shifts in favor of accelerated oxidation during ageing. That is demonstrated by increases of MDA, HNE, GSSG and by the slight decrease of erythrocytic GSH with age. As the content of UA is more determined by metabolic and nutritional influences than by the balance between prooxidants and antioxidants there was no significant age-related change observed. For plasma concentrations of HNE the first time age-dependent reference values for healthy humans are presented.  相似文献   

20.
A mass spectrometric analysis of the water-splitting reaction   总被引:2,自引:0,他引:2  
Earlier mass spectrometric measurements, in which oxygen evolution was measured following short saturating light flashes, indicated that with a time resolution of about 30 s no form of bound water and/or an oxidation product exists up to the redox state S3 of the oxygen evolving center (R. Radmer and O. Ollinger, 1986, FEBS Lett 195: 285–289; K.P. Bader, P. Thibault and G.H. Schmid, 1987, Biochim Biophys Acta 893: 564–571). In the present study, isotope exchange experiments with H2 18O were performed under different experimental conditions. We found: a) the isotope exchange pattern is virtually the same at both pH 6.0 and 7.8, although marked structural changes of the PS II donor side are inferred to take place within this pH-range (Renger G., Messinger J. and Wacker U., 1992, Research in Photosynthesis, II: 329–332); b) injection of H2 18O at about 0°C gives rise to mass ratios of the evolved oxygen which markedly deviate from the theoretically expected values of complete isotope scrambling; and c) rapid injection of H2 18O into samples with high population of S1 and S2 and subsequent illumination with three and two flashes, respectively, spaced by a dark time of only 1.5 ms lead to similar 18O-labeling of the evolved oxygen. Based on the published data on the interaction with redox active amines, possible pathways of substrate exchange in the water oxidase are discussed.Abbreviations atom fraction of 18O - PS II Photosystem II - Si redox states of the water oxidase - Yz redox active tyrosine of polypeptide D1  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号