首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A variety of quantitative proteomics methods have been developed, including label-free, metabolic labeling, and isobaric chemical labeling using iTRAQ or TMT. Here, these methods were compared in terms of the depth of proteome coverage, quantification accuracy, precision, and reproducibility using a high-performance hybrid mass spectrometer, LTQ Orbitrap Velos. Our results show that (1) the spectral counting method provides the deepest proteome coverage for identification, but its quantification performance is worse than labeling-based approaches, especially the quantification reproducibility; (2) metabolic labeling and isobaric chemical labeling are capable of accurate, precise, and reproducible quantification and provide deep proteome coverage for quantification; isobaric chemical labeling surpasses metabolic labeling in terms of quantification precision and reproducibility; and (3) iTRAQ and TMT perform similarly in all aspects compared in the current study using a CID-HCD dual scan configuration. On the basis of the unique advantages of each method, we provide guidance for selection of the appropriate method for a quantitative proteomics study.  相似文献   

2.
We describe and review progress towards a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements for microbial systems based upon the use of polypeptide accurate mass tags (AMTs) produced by global protein enzymatic digestions. The two-stage strategy exploits high accuracy mass measurements using Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate polypeptide AMTs for a specific organism, from potential mass tags tentatively identified using tandem mass spectrometry (MS/MS), providing the basis for subsequent measurements without the need for routine MS/MS. A high-resolution capillary liquid chromatography separation combined with high sensitivity, and high-resolution accurate FTICR measurements is shown to be capable of characterizing polypeptide mixtures of more than 10(5) components, sufficient for broad protein identification using AMTs. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, and the capability for stable-isotope labeling methods for precise relative protein abundance measurements. The strategy has been initially evaluated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Additional developments, including the use of multiplexed-MS/MS capabilities and methods for dynamic range expansion of proteome measurements that promise to further extend the quality of proteomics measurements, are also described.  相似文献   

3.
Ideally, shotgun proteomics would facilitate the identification of an entire proteome with 100% protein sequence coverage. In reality, the large dynamic range and complexity of cellular proteomes results in oversampling of abundant proteins, while peptides from low abundance proteins are undersampled or remain undetected. We tested the proteome equalization technology, ProteoMiner, in conjunction with Multidimensional Protein Identification Technology (MudPIT) to determine how the equalization of protein dynamic range could improve shotgun proteomics methods for the analysis of cellular proteomes. Our results suggest low abundance protein identifications were improved by two mechanisms: (1) depletion of high abundance proteins freed ion trap sampling space usually occupied by high abundance peptides and (2) enrichment of low abundance proteins increased the probability of sampling their corresponding more abundant peptides. Both mechanisms also contributed to dramatic increases in the quantity of peptides identified and the quality of MS/MS spectra acquired due to increases in precursor intensity of peptides from low abundance proteins. From our large data set of identified proteins, we categorized the dominant physicochemical factors that facilitate proteome equalization with a hexapeptide library. These results illustrate that equalization of the dynamic range of the cellular proteome is a promising methodology to improve low abundance protein identification confidence, reproducibility, and sequence coverage in shotgun proteomics experiments, opening a new avenue of research for improving proteome coverage.  相似文献   

4.
In order to validate a gel free quantitative proteomics assay for the model methylotrophic bacterium Methylobacterium extorquens AM1, we examined the M. extorquens AM1 proteome under single carbon (methanol) and multicarbon (succinate) growth, conditions that have been studied for decades and for which extensive corroborative data have been compiled. In total, 4447 proteins from a database containing 7556 putative ORFs from M. extorquens AM1 could be identified with two or more peptide sequences, corresponding to a qualitative proteome coverage of 58%. Statistically significant nonzero (log(2) scale) differential abundance ratios of methanol/succinate could be detected for 317 proteins using summed ion intensity measurements and 585 proteins using spectral counting, at a q-value cut-off of 0.01, a measure of false discovery rate. The results were compared to recent microarray studies performed under equivalent chemostat conditions. The M. extorquens AM1 studies demonstrated the feasibility of scaling up the multidimensional capillary HPLC MS/MS approach to a prokaryotic organism with a proteome more than three times the size of microbes we have investigated previously, while maintaining a high degree of proteome coverage and reliable quantitative abundance ratios.  相似文献   

5.
Progress is reviewed towards the development of a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness and throughput of proteomic measurements based upon the use of high performance separations and mass spectrometry. The approach uses high accuracy mass measurements from Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate peptide 'accurate mass tags' (AMTs) produced by global protein enzymatic digestions for a specific organism, tissue or cell type from 'potential mass tags' tentatively identified using conventional tandem mass spectrometry (MS/MS). This provides the basis for subsequent measurements without the need for MS/ MS. High resolution capillary liquid chromatography separations combined with high sensitivity, and high resolution accurate FTICR measurements are shown to be capable of characterizing peptide mixtures of more than 10(5) components. The strategy has been initially demonstrated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, high sensitivity, and the capability for stableisotope labeling methods for precise relative protein abundance measurements.Abbreviations: LC, liquid chromatography; FTICR, Fourier transform ion cyclotron resonance; AMT, accurate mass tag; PMT, potential mass tag; MMA, mass measurement accuracy; MS, mass spectrometry; MS/MS, tandem mass spectrometry; ppm, parts per million.  相似文献   

6.
Various enzyme reactors and online enzyme digestion strategies have been developed in recent years. These reactors greatly enhanced the detection sensitivity and proteome coverage in qualitative proteomics. However, these devices have higher rates of miscleavage in protein digestion. Therefore, we investigated the effect of online enzyme digestion on the quantification accuracy of quantitative proteomics using chemical or metabolic isotope labeling approaches. The incomplete digestion would introduce some unexpected variations in comparative quantification when the samples are digested and then chemically isotope labeled in different aliquots. Even when identical protein aliquots are processed on these devices using post‐digestion chemical isotope labeling and the CVs of the ratios controlled to less than 50% in replicate analyses, about 10% of the quantified proteins have a ratio greater than two‐fold, whereas in theory the ratio is 1:1. Interestingly, the incomplete digestion with enzyme reactor is not a problem when metabolic isotope labeling samples were processed because the proteins are isotopically labeled in vivo prior to their simultaneous digestion within the reactor. Our results also demonstrated that both high quantification accuracy and high proteome coverage can be achieved in comparative proteome quantification using online enzyme digestion even when a limited amount of metabolic isotope labeling samples is used (1683 proteins comparatively quantified from 105 Hela cells).  相似文献   

7.
Label-free methods streamline quantitative proteomics of tissues by alleviating the need for metabolic labeling of proteins with stable isotopes. Here we detail and implement solutions to common problems in label-free data processing geared toward tissue proteomics by one-dimensional gel electrophoresis followed by liquid chromatography tandem mass spectrometry (geLC MS/MS). Our quantification pipeline showed high levels of performance in terms of duplicate reproducibility, linear dynamic range, and number of proteins identified and quantified. When applied to the liver of an adenomatous polyposis coli (APC) knockout mouse, we demonstrated an 8-fold increase in the number of statistically significant changing proteins compared to alternative approaches, including many more previously unidentified hydrophobic proteins. Better proteome coverage and quantification accuracy revealed molecular details of the perturbed energy metabolism.  相似文献   

8.
9.
Liquid chromatography MALDI MS/MS for membrane proteome analysis   总被引:3,自引:0,他引:3  
Membrane proteins play critical roles in many biological functions and are often the molecular targets for drug discovery. However, their analysis presents a special challenge largely due to their highly hydrophobic nature. We present a surfactant-aided shotgun proteomics approach for membrane proteome analysis. In this approach, membrane proteins were solubilized and digested in the presence of SDS followed by newly developed auto-offline liquid chromatography/matrix-assisted laser desorption ionization (LC/MALDI) tandem MS analysis. Because of high tolerance of MALDI to SDS, one-dimensional (1D) LC separation can be combined with MALDI for direct analysis of protein digests containing SDS, without the need for extensive sample cleanup. In addition, the heated droplet interface used in LC/MALDI can work with high flow LC separations, allowing a relatively large amount of protein digest to be used for 1D LC/MALDI which facilitates the detection of low abundance proteins. The proteome identification results obtained by LC/MALDI are compared to the gel electrophoresis/MS method as well as the shotgun proteomics method using 2D LC/electrospray ionization MS. It is demonstrated that, while LC/MALDI provides more extensive proteome coverage compared to the other two methods, these three methods are complementary to each other and a combination of these methods should provide a more comprehensive membrane proteome analysis.  相似文献   

10.
A crucial issue in comparative proteomics is the accurate quantification of differences in protein expression levels. To achieve this, several methods have been developed in which proteins are labeled with stable isotopes either in vivo via metabolic labeling or in vitro by protein derivatization. Although metabolic labeling is the only way to obtain labeling of all proteins, it has thus far only been applied to single- celled organisms and cells in culture. Here we describe quantitative 15N metabolic labeling of the multicellular organisms Caenorhabditis elegans, a nematode, and Drosophila melanogaster, the common fruit fly, achieved by feeding them on 15N-labeled Escherichia coli and yeast, respectively. The relative abundance of individual proteins obtained from different samples can then be determined by mass spectrometry (MS). The applicability of the method is exemplified by the comparison of protein expression levels in two C. elegans strains, one with and one without a germ line. The methodology described provides tools for accurate quantitative proteomic studies in these model organisms.  相似文献   

11.
This study reports the comprehensive comparison of (15)N metabolic labeling and label free proteomic strategies for quantitation, with particular focus on plant proteomics. Our investigation of proteome coverage, dynamic range and quantitative precision for a wide range of mixing ratios and protein loadings aim to aid the investigators in the decision making process during experimental design. One of the main characteristics of the label free strategy is the applicability to all starting material, which is a limitation to the metabolic labeling. However, particularly at mixing ratios up to 10-fold the (15)N metabolic labeling proved to be more precise. Contrary to usual practice based on the results from this study, we suggest that nonequal mixing ratios in metabolic labeling could further increase the proteome coverage for quantitation. On the other hand, the label free strategy, in combination with low protein loading allows the extension of the dynamic range for quantitation and it is more precise at very high ratios, which could be important for certain types of experiments.  相似文献   

12.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) and multiple reaction monitoring mass spectrometry (MRM-MS) proteomics analyses were performed on eccrine sweat of healthy controls, and the results were compared with those from individuals diagnosed with schizophrenia (SZ). This is the first large scale study of the sweat proteome. First, we performed LC-MS/MS on pooled SZ samples and pooled control samples for global proteomics analysis. Results revealed a high abundance of diverse proteins and peptides in eccrine sweat. Most of the proteins identified from sweat samples were found to be different than the most abundant proteins from serum, which indicates that eccrine sweat is not simply a plasma transudate and may thereby be a source of unique disease-associated biomolecules. A second independent set of patient and control sweat samples were analyzed by LC-MS/MS and spectral counting to determine qualitative protein differential abundances between the control and disease groups. Differential abundances of selected proteins, initially determined by spectral counting, were verified by MRM-MS analyses. Seventeen proteins showed a differential abundance of approximately 2-fold or greater between the SZ pooled sample and the control pooled sample. This study demonstrates the utility of LC-MS/MS and MRM-MS as a viable strategy for the discovery and verification of potential sweat protein disease biomarkers.  相似文献   

13.
MS‐based proteomics has emerged as a powerful tool in biological studies. The shotgun proteomics strategy, in which proteolytic peptides are analyzed in data‐dependent mode, enables a detection of the most comprehensive proteome (>10 000 proteins from whole‐cell lysate). The quantitative proteomics uses stable isotopes or label‐free method to measure relative protein abundance. The isotope labeling strategies are more precise and accurate compared to label‐free methods, but labeling procedures are complicated and expensive, and the sample number and types are also limited. Sequential window acquisition of all theoretical mass spectra (SWATH) is a recently developed technique, in which data‐independent acquisition is coupled with peptide spectral library match. In principle SWATH method is able to do label‐free quantification in an MRM‐like manner, which has higher quantification accuracy and precision. Previous data have demonstrated that SWATH can be used to quantify less complex systems, such as spiked‐in peptide mixture or protein complex. Our study first time assessed the quantification performance of SWATH method on proteome scale using a complex mouse‐cell lysate sample. In total 3600 proteins got identified and quantified without sample prefractionation. The SWATH method shows outstanding quantification precision, whereas the quantification accuracy becomes less perfect when protein abundances differ greatly. However, this inaccuracy does not prevent discovering biological correlates, because the measured signal intensities had linear relationship to the sample loading amounts; thus the SWATH method can predict precisely the significance of a protein. Our results prove that SWATH can provide precise label‐free quantification on proteome scale.  相似文献   

14.
Elucidation of in vivo substrate degradomes of a protease is a daunting endeavor because of the large number of proteins in a proteome and often minute and transient amounts of key substrates. Proteomic substrate screens for proteases are currently experiencing impressive progress. Mass spectrometry-based global proteome analysis, interfaced with liquid-chromatography and together with stable isotope labeling strategies, has provided increased coverage and sensitivity for quantitative proteomics. ICAT and iTRAQ labeling have been used to identify a plethora of new matrix metalloproteinase substrates. Emerging techniques focus on the quantitative analysis of proteolytically generated neo amino-termini, which we call terminopes, on a system-wide basis. In vivo SILAC pulse-chase experiments have also enabled the study of individual protein turnover and global proteome dynamics in cells and whole organisms. Together with activity-based probes for the profiling of functional proteases, there is now in place an array of complementary technologies to dissect the 'protease web' and its distortion in pathology.  相似文献   

15.
Mass spectrometry has served as a major tool for the discipline of proteomics to catalogue proteins in an unprecedented scale. With chemical and metabolic techniques for stable isotope labeling developed over the past decade, it is now routinely used as a method for relative quantification to provide valuable information on alteration of protein abundance in a proteome-wide scale. More recently, absolute or stoichiometric quantification of proteome is becoming feasible, in particular, with the development of strategies with isotope-labeled standards composed of concatenated peptides. On the other hand, remarkable progress has been also made in label-free quantification methods based on the number of identified peptides. Here we review these mass spectrometry-based approaches for absolute quantification of proteome and discuss their implications.Key Words: Quantitative proteomics, mass spectrometry, absolute quantification, stable isotope labeling, label-free.  相似文献   

16.
Corynebacterium glutamicum can utilize various monocyclic aromatic carbon sources, including protocatechuate, which is catabolized via the β-ketoadipate pathway. In order to obtain a global survey of occurring physiological adaptations on the proteome level, cytoplasmic and membrane fraction from cells grown on protocatechuate or glucose as sole carbon and energy source were compared. Shotgun proteomics and relative protein quantification with metabolic isotope labeling and spectral counting were employed. Altogether, 139 proteins were found to change their abundance during growth on protocatechuate. A general adaptation of energy metabolism to meet increased energy production by oxidative phosphorylation and a stress response occurred. Adjustments of carbon and amino acid metabolism in the cytoplasmic and membrane proteome were indicative of a starvation response. The different regulation of porins and cell wall biosynthesis proteins suggests a change in its architecture upon assimilation of the aromatic carbon source. Some of the observed changes could be explained by an involvement of the GlxR and McbR regulons.  相似文献   

17.
18.
We describe and demonstrate a global strategy that extends the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements based upon the use of peptide "accurate mass tags" (AMTs) produced by global protein enzymatic digestion. The two-stage strategy exploits Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry to validate peptide AMTs for a specific organism, tissue or cell type from "potential mass tags" identified using conventional tandem mass spectrometry (MS/MS) methods, providing greater confidence in identifications as well as the basis for subsequent measurements without the need for MS/MS, and thus with greater sensitivity and increased throughput. A single high resolution capillary liquid chromatography separation combined with high sensitivity, high resolution and accurate FT-ICR measurements has been shown capable of characterizing peptide mixtures of significantly more than 10(5) components with mass accuracies of < 1 ppm, sufficient for broad protein identification using AMTs. Other attractions of the approach include the broad and relatively unbiased proteome coverage, the capability for exploiting stable isotope labeling methods to realize high precision for relative protein abundance measurements, and the projected potential for study of mammalian proteomes when combined with additional sample fractionation. Using this strategy, in our first application we have been able to identify AMTs for >60% of the potentially expressed proteins in the organism Deinococcus radiodurans.  相似文献   

19.
Yi Yang  Liang Qiao 《Proteomics》2023,23(7-8):2200046
Protein post-translational modifications (PTMs) increase the functional diversity of the cellular proteome. Accurate and high throughput identification and quantification of protein PTMs is a key task in proteomics research. Recent advancements in data-independent acquisition (DIA) mass spectrometry (MS) technology have achieved deep coverage and accurate quantification of proteins and PTMs. This review provides an overview of DIA data processing methods that cover three aspects of PTMs analysis, that is, detection of PTMs, site localization, and characterization of complex modification moieties, such as glycosylation. In addition, a survey of deep learning methods that boost DIA-based PTMs analysis is presented, including in silico spectral library generation, as well as feature scoring and error rate control. The limitations and future directions of DIA methods for PTMs analysis are also discussed. Novel data analysis methods will take advantage of advanced MS instrumentation techniques to empower DIA MS for in-depth and accurate PTMs measurements.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号