首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到13条相似文献,搜索用时 15 毫秒
1.
A convenient and precise chiral method was developed and validated for measuring indoxacarb enantiomers in cucumber and tomato using liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) with a reversed‐phase Chiralpak AD‐RH column. The target analytes were extracted by acetonitrile and then purified by solid phase extraction (SPE) using NH2/Carb combined‐cartridge. Parameters including the matrix effect, linearity, precision, accuracy, and stability were used. Then the proposed method was successfully applied to investigate the possible enantioselective degradation of rac‐indoxacarb in cucumber and tomato under open conditions. The results indicated that the degradation of indoxacarb enantiomers followed first‐order kinetics in cucumber and tomato. The half‐lives of (+)‐S‐indoxacarb in cucumber and tomato were 3.0 and 5.9 days, respectively; while the (–)‐R‐indoxacarb were 7.3 and 12.2 days, respectively. The data of the half‐lives showed that (+)‐S‐indoxacarb was preferentially degraded in cucumber and tomato. Moreover, indoxacarb degraded faster in cucumber than in tomato. Chirality 25:350–354:, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

2.
The behavior and mechanisms of the enantioselective degradation of beta‐cypermethrin were studied in soil. The four isomers were degraded at different rates, and the enantiomer fractions of alpha‐cypermethrin and theta‐cypermethrin exceeded 0.5. Moreover, 3‐phenoxybenzoic acid, phenol, and protocatechuic acid were detected; based on the presence of these metabolites, we predicted the degradation pathway and identified the functional genes that are related to this degradation process. We established quantitative relationships between the data on degradation kinetics and functional genes; we found that the quantitative relationships between different enantiomers differed even under the same conditions, and the genes pobA and pytH played key roles in limiting the degradation rate. Data obtained using path analysis revealed that the same gene had different direct and indirect effects on the degradation of different isomers. A mechanism was successfully proposed to explain the selective degradation of chiral compounds based on the perspective of functional genes. Chirality 27:929–935, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

3.
Citalopram (CITA) is available as a racemic mixture and as a pure enantiomer. Its antidepressive action is related to the (+)-(S)-CITA and to the metabolite (+)-(S)-demethylcitalopram (DCITA). In the present investigation, a method for the analysis of CITA and DCITA enantiomers in human and rat plasma was developed and applied to the study of pharmacokinetics. Plasma samples (1 ml) were extracted at pH 9.0 with toluene:isoamyl alcohol (9:1, v/v). The CITA and DCITA enantiomers were analyzed by LC-MS/MS on a Chiralcel OD-R column. Recovery was higher than 70% for both enantiomers. The quantification limit was 0.1 ng/ml, and linearity was observed up to 500 ng/ml plasma for each CITA and DCITA enantiomer. The method was applied to the study of the kinetic disposition of CITA administered in a single oral dose of 20 mg to a healthy volunteer and in a single dose of 20 mg/kg (by gavage) to Wistar rats (n = 6 for each time). The results showed a higher proportion of the (-)-(R)-CITA in human and rat plasma, with S/R AUC ratios for CITA of 0.28 and 0.44, respectively. S/R AUC ratios of DCITA were 0.48 for rats and 1.04 for the healthy volunteer.  相似文献   

4.
In this study we investigated the enantioselective degradation of (2RS,3RS)‐paclobutrazol in peach and mandarin fruits under field conditions after foliar treatment at 500 mg active ingredient/L using a Lux Cellulose‐1 chiral column on a reverse‐phase liquid chromatography–tandem mass spectrometry system. Degradations of paclobutrazol in both fruits followed first‐order kinetics, with half‐lives of about 9 days. Initial deposits were 1.63 mg/kg on peach and 1.99 mg/kg on mandarin; terminal concentrations were lower than 0.05 mg/kg, which was acceptable in most cases. As anticipated, paclobutrazol levels in peels of mature mandarin were about 6.3 times higher than in pulp, indicating the potential risk of peel consumption. We also observed that paclobutrazol degradation in mature mandarin was relatively slow, indicating it might not be efficient enough to hold mandarin fruits on trees for lowering paclobutrazol concentrations. Significant enantioselectivity was observed: the (2R,3R)‐enantiomer was preferentially degraded in mandarin (whole fruit, peels, and pulp) but enriched in peach. Because of its more rapid degradation in mandarin and the lower levels observed in pulp compared with peels, potential endocrine‐related side effects due to the (2R,3R)‐enantiomer pose less of a risk in mandarin than in peach. Chirality 26:400–404, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

5.
Fluoxetine is used clinically as a racemic mixture of (+)‐(S) and (–)‐(R) enantiomers for the treatment of depression. CYP2D6 catalyzes the metabolism of both fluoxetine enantiomers. We aimed to evaluate whether exposure to gasoline results in CYP2D inhibition. Male Wistar rats exposed to filtered air (n = 36; control group) or to 600 ppm of gasoline (n = 36) in a nose‐only inhalation exposure chamber for 6 weeks (6 h/day, 5 days/week) received a single oral 10‐mg/kg dose of racemic fluoxetine. Fluoxetine enantiomers in plasma samples were analyzed by a validated analytical method using LC‐MS/MS. The separation of fluoxetine enantiomers was performed in a Chirobiotic V column using as the mobile phase a mixture of ethanol:ammonium acetate 15 mM. Higher plasma concentrations of the (+)‐(S)‐fluoxetine enantiomer were found in the control group (enantiomeric ratio AUC(+)‐(S)/(–)‐(R) = 1.68). In animals exposed to gasoline, we observed an increase in AUC0‐∞ for both enantiomers, with a sharper increase seen for the (–)‐(R)‐fluoxetine enantiomer (enantiomeric ratio AUC(+)‐(S)/(–)‐(R) = 1.07), resulting in a loss of enantioselectivity. Exposure to gasoline was found to result in the loss of enantioselectivity of fluoxetine, with the predominant reduction occurring in the clearance of the (–)‐(R)‐fluoxetine enantiomer (55% vs. 30%). Chirality 25:206–210, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

6.
A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (-)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic-lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation.  相似文献   

7.
Mexiletine (MEX), hydroxymethylmexiletine (HMM) and p-hydroxymexiletine (PHM) were analyzed in rat plasma by LC-MS/MS. The plasma samples were prepared by liquid-liquid extraction using methyl-tert-butyl ether as extracting solvent. MEX, HMM, and PHM enantiomers were resolved on a Chiralpak(R) AD column. Validation of the method showed a relative standard deviation (precision) and relative errors (accuracy) of less than 15% for all analytes studied. Quantification limits were 0.5 ng ml(-1) for the MEX and 0.2 ng ml(-1) for the HMM and PHM enantiomers. The validated method was successfully applied to quantify the enantiomers of MEX and its metabolites in plasma samples of rats (n = 6) treated with a single oral dose of racemic MEX.  相似文献   

8.
Chiral pesticide enantiomers often show different bioactivity and toxicity; however, this property is usually ignored when evaluating their environmental and public health risks. Hexaconazole is a chiral fungicide used on a variety of crops for the control of many fungal diseases. This use provides opportunities for the pollution of food and soil. In this study, a sensitive and convenient chiral liquid chromatography coupled with tandem mass spectrometry (LC‐MS/MS) method was developed and validated for measuring hexaconazole enantiomers in tomato, cucumber, and soil. Separation was by a reversed‐phase Chiralcel OD‐RH column, under isocratic conditions using a mixture of acetonitrile‐2 mM ammonium acetate in water (60/40, v/v) as the mobile phase at a flow rate of 0.4 mL/min. Parameters including the matrix effect, linearity, precision, accuracy and stability were undertaken. Then the proposed method was successfully applied to investigate the possible enantioselective degradation of rac‐hexaconazole in plants (tomato and cucumber) and soil under field conditions. The degradation of the two enantiomers of hexaconazole proved to be enantioselective and dependent on the media: The (+)‐enantiomer showed a faster degradation in plants, while the (?)‐enantiomer dissipated faster than the (+)‐form in field soil, resulting in relative enrichment of the opposite enantiomer. The results of this work demonstrate that both the environmental media and environmental conditions influenced the direction and rate of enantioselective degradation of hexaconazole. Chirality 25:160–169, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

9.
Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the β1‐antagonism and the stereoisomer (S,R) is highly selective for the α1 adrenoceptor and is responsible for most of the α‐blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert‐butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC‐MS/MS on a Chirobiotic® V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)‐labetalol and (S,R)‐labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC(R,R)/AUC(S,S) ratio of 0.5. Chirality, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

10.
This article describes the enantioselective analysis of cyclophosphamide (CPA) in human plasma using LC-MS/MS. CPA enantiomers were extracted from plasma using a mixture of ethyl acetate and chloroform (75:25, v/v). The enantiomers were separated on a Chiralcel(R) OD-R column, with the mobile phase consisting of a mixture of acetonitrile and water (75:25, v/v) plus 0.2% formic acid. The protonated ions and their respective product ions were monitored using two functions, 261 > 141 for CPA enantiomers and 189 > 104 for the internal standard (antipyrine). Recovery rates were higher than 95% and the quantification limit was 2.5-ng/ml plasma for both enantiomers. The coefficients of variation and the relative errors obtained for the validation of intra- and interassay precision and accuracy were less than 10%. The method was applied for the investigation of the enantioselective pharmacokinetics of CPA in a lupus nephritis patient treated with 1 g CPA infused over 2 h and in a breast cancer patient treated with 0.9 g infused over 1 h. No stereoselectivity in the pharmacokinetic parameters was observed for either patient. Clearance values of 2.63 and 2.93 l/h and of 3.36 and 3.61 l/h for (-)-(S) and (+)-(R)-CPA were obtained for the breast cancer and lupus nephritis patient, respectively.  相似文献   

11.
Metoprolol is available for clinical use as a racemic mixture. The S‐(?)‐metoprolol enantiomer is the one expressing higher activity in the blockade of the β1‐adrenergic receptor. The α‐hydroxymetoprolol metabolite also has activity in the blockade of the β1‐adrenergic receptor. The present study describes the development and validation of a stereoselective method for sequential analysis of metoprolol and of α‐hydroxymetoprolol in plasma using high‐performance liquid chromatography with tandem mass spectrometry (LC‐MS/MS). 1‐ml aliquots of plasma were extracted with dichloromethane : diisopropyl ether (1:1, v/v). Metoprolol enantiomers and α‐hydroxymetoprolol isomers were separated on a Chiralpak AD column (Daicel Chemical Industries, New York, NY, USA) and quantitated by LC‐MS/MS. The limit of quantitation obtained was 0.2 ng of each metoprolol enantiomer/ml plasma and 0.1 ng/ml of each α‐hydroxymetoprolol isomer/ml plasma. The method was applied to the study of kinetic disposition of metoprolol in plasma samples collected up to 24 h after the administration of a single oral dose of 100‐mg metoprolol tartrate to a hypertensive parturient with a gestational age of 42 weeks. The clinical study showed that the metoprolol pharmakokinetics is enantioselective, with the observation of higher area under the curve (AUC)0?∞ values for S‐(?)‐metoprolol (AUCS‐(?)/AUCR‐(+) = 1.81) and the favoring of the formation of the new chiral center 1′R of α‐hydroxymetoprolol (AUC0?∞1′R/1′S = 2.78). Chirality, 25:1–7, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

12.
Tramadol (T) is available as a racemic mixture of (+)‐trans‐T and (−)‐trans‐T. The main metabolic pathways are O‐demethylation and N‐demethylation, producing trans‐O‐desmethyltramadol ( M1 ) and trans‐N‐desmethyltramadol ( M2 ) enantiomers, respectively. The analgesic effect of T is related to the opioid activity of (+)‐trans‐T and (+)‐ M1 and to the monoaminergic action of (+/−)‐trans‐T. This is the first study using tandem mass spectrometry as a detection system for the simultaneous analysis of trans‐T, M1 , and M2 enantiomers. The analytes were resolved on a Chiralpak® AD column using hexane:ethanol (95.5:4.5, v/v) plus 0.1% diethylamine as the mobile phase. The quantitation limits were 0.5 ng/ml for trans‐T and M1 and 0.1 ng/ml for M2 . The method developed and validated here was applied to a pharmacokinetic study in rats. Male Wistar rats (n = 6 at each time point) received a single oral dose of 20 mg/kg racemic trans‐T. Blood samples were collected up to 12 h after drug administration. The kinetic disposition of trans‐T and M2 was enantioselective (AUC(+)/(−) ratio = 4.16 and 6.36, respectively). The direction and extent of enantioselectivity in the pharmacokinetics of trans‐T and M2 in rats were comparable to data previously reported for healthy volunteers, suggesting that rats are a suitable model for enantioselective studies of trans‐T pharmacokinetics. Chirality, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

13.
The investigation presented here describes a protocol designed to perform high-throughput metabolic profiling analysis on human blood plasma by ultra-performance liquid chromatography/mass spectrometry (UPLC/MS). To address whether a previous extraction protocol for gas chromatography (GC)/MS-based metabolic profiling of plasma could be used for UPLC/MS-based analysis, the original protocol was compared with similar methods for extraction of low-molecular-weight compounds from plasma via protein precipitation. Differences between extraction methods could be observed, but the previously published extraction method was considered the best. UPLC columns with three different stationary phases (C8, C18, and phenyl) were used in identical experimental runs consisting of a total of 60 injections of extracted male and female plasma samples. The C8 column was determined to be the best for metabolic profiling analysis on plasma. The acquired UPLC/MS data of extracted male and female plasma samples was subjected to principal component analysis (PCA) and orthogonal projections to latent structures discriminant analysis (OPLS-DA). Furthermore, a strategy for compound identification was applied here, demonstrating the strength of high-mass-accuracy time-of-flight (TOF)/MS analysis in metabolic profiling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号