A sensitive and rapid method was developed and validated for the quantitative analysis of the novel anticancer agent SZ-685C in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in negative ion mode in order to support the following pre-clinical and clinical studies. SZ-685C and the internal standard (IS, emodin) were extracted from rat plasma by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. Chromatographic separation was performed on an Elite Hypersil BDS C18 column (100 mm × 2.1 mm i.d., 3 μm). Elution was carried out using methanol/acetonitrile/2mM ammonium formate (pH 4) (80:15:5 (v/v/v)) at a flow-rate of 0.3 mL/min with a run time of 2.5 min. This assay was linear over a concentration range of 50-10,000 ng/mL with a lower limit of quantification of 50 ng/mL. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 100, 1000 and 7500 ng/mL. These results indicate that the method was efficient with a short run time and acceptable accuracy, precision and sensitivity. This method was successfully applied to explore pharmacokinetics of SZ-685C in rats after oral and intravenous administration of this agent. The absolute bioavailability is about 54.8-66.8% and the t(1/2) is 5.7-9.2h, these results provide basic information for further comprehensive pre-clinical research.  相似文献   

2.
The purpose of this study was to develop and validate a high-performance liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for analysis of the deacetyl mycoepoxydiene in rat plasma. The analyte and internal standard (I.S.), benorilate, were extracted from rat plasma by precipitation protein and separated on a C(18) column using acetonitrile-0.5% formic acid as mobile phase. Detection was performed using a turbo-spray ionization source and mass spectrometric positive multi-reaction-monitoring-mode (+MRM) at an ion voltage of +4800 V. The assay was linear over the concentration range 5-5000 ng/mL with the lowest limit of quantification (LLOQ) of 5 ng/mL. The method also afforded satisfactory results in terms of the sensitivity, specificity, precision (intra- and inter-day, RSD<5.8%), accuracy, recovery as well as the stability of the analyte under various conditions. The method was successfully applied to a preclinical pharmacokinetic study in rats after a single intravenous administration of deacetyl mycoepoxydiene 10 mg/kg.  相似文献   

3.
A sensitive and rapid ELISA for quantitation of seed globulins is described. This method employs conjugation of pigeon pea (Cajanus cajan) globulin antibodies and the enzyme peroxidase together with dextran. Using this conjugate, proteins as low as 0.1 ng were detected. Dextran conjugate has a ten-fold greater efficiency of quantitating pigeon pea globulins than the commercial goat anti-rabbit IgG conjugate, and is three-fold more efficient than pigeon pea globulin IgG peroxidase conjugate. The method can be conveniently adapted for quantitation of other proteins also.  相似文献   

4.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

5.
A rapid and simple method for quantitation of metformin (MET) in human plasma by HPLC-MS/MS was developed and validated. The sample preparation consists of plasma deproteinization using acetonitrile. The mobile phase consisted of water-acetonitrile and formic acid (55/45/0.048, v/v/%) and the run time was 3 min. A pursuit C(18) (100 mm x 2.0 mm i.d., 3 microm) column connected to a guard column MS-pursuit (0.20 mm x 0.20 mm i.d., 5 microm) was used. The range of the calibration curve was from 20 to 5000 ng/mL, the limit of quantitation being 20 ng/mL. The detection was performed on a mass spectrometer (ESI+), using metoprolol as internal standard. The calibration curves have r(2) values of 0.995 (CV=0.24%, n=10). The accuracy and precision were between 90.74 and 106.7% and coefficients of variations (CV) of 1.10 and 4.35%, respectively. The method was applied to determine the pharmacokinetic parameters: C(max) (1667.25 ng/mL) and T(max) (3.89 h).  相似文献   

6.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA.  相似文献   

7.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

8.
A rapid, accurate and highly sensitive method was developed for the determination of isosorbide dinitrate in human plasma. Concentrations in the lower nanogram and subnanogram range are determined by a one-step extraction of 2 ml plasma, containing 4 ng/ml nitroglycerine as internal standard, with 5.5 ml n-pentane. The extract is subjected to gas—liquid chromatography—electron capture detection analysis. The lower limit of quantitation is 200 pg/ml, but concentrations as low as 50 pg/ml are still detectable. The method allows the quantitative determination of isosorbide dinitrate plasma levels in man following a 5 mg sublingual administration up to four hours after application.  相似文献   

9.
T E Bridges  V Marino 《Life sciences》1987,41(26):2815-2822
A simple, rapid and sensitive method, using isocratic reversed-phase HPLC, is described for the concomitant identification and quantitation of low levels of the various neurohypophysial peptides in biological tissues and fluids. The method requires little or no sample preparation and utilises UV peak detection at 215 nm with a serial signal amplification system to achieve a usable maximum sensitivity of less than 200 fmol of peptide.  相似文献   

10.
Niemann-Pick type C1 (NPC1) disease is a rare, progressively fatal neurodegenerative disease for which there are no FDA-approved therapies. A major barrier to developing new therapies for this disorder has been the lack of a sensitive and noninvasive diagnostic test. Recently, we demonstrated that two cholesterol oxidation products, specifically cholestane-3β,5α,6β-triol (3β,5α,6β-triol) and 7-ketocholesterol (7-KC), were markedly increased in the plasma of human NPC1 subjects, suggesting a role for these oxysterols in diagnosis of NPC1 disease and evaluation of therapeutics in clinical trials. In the present study, we describe the development of a sensitive and specific LC-MS/MS method for quantifying 3β,5α,6β-triol and 7-KC human plasma after derivatization with N,N-dimethylglycine. We show that dimethylglycine derivatization successfully enhanced the ionization and fragmentation of 3β,5α,6β-triol and 7-KC for mass spectrometric detection of the oxysterol species in human plasma. The oxysterol dimethylglycinates were resolved with high sensitivity and selectivity, and enabled accurate quantification of 3β,5α,6β-triol and 7-KC concentrations in human plasma. The LC-MS/MS assay was able to discriminate with high sensitivity and specificity between control and NPC1 subjects, and offers for the first time a noninvasive, rapid, and highly sensitive method for diagnosis of NPC1 disease.  相似文献   

11.
A rapid chemiluminescent method for quantitation of human DNA.   总被引:15,自引:0,他引:15       下载免费PDF全文
A sensitive and simple method for the quantitation of human DNA is described. This method is based on probe hybridization to a human alpha satellite locus, D17Z1. The biotinylated probe is hybridized to sample DNA immobilized on nylon membrane. The subsequent binding of streptavidin-horseradish peroxidase to the bound probe allows for chemiluminescent detection using a luminol-based reagent and X-ray film. Less than 150 pg of human DNA can easily be detected with a 15 minute exposure. The entire procedure can be performed in 1.5 hours. Microgram quantities of nonhuman DNA have been tested and the results indicate very high specificity for human DNA. The data on film can be scanned into a computer and a commercially available program can be used to create a standard curve where DNA quantity is plotted against the mean density of each slot blot signal. The methods described can also be applied to the very sensitive determination of quantity and quality (size) of DNA on Southern blots. The high sensitivity of this quantitation method requires the consumption of only a fraction of sample for analysis. Determination of DNA quantity is necessary for RFLP and many PCR-based tests where optimal results are obtained only with a relatively narrow range of DNA quantities. The specificity of this quantitation method for human DNA will be useful for the analysis of samples that may also contain bacterial or other non-human DNA, for example forensic evidence samples, ancient DNA samples, or clinical samples.  相似文献   

12.
A selective and highly sensitive isocratic high performance liquid chromatographic (HPLC) method is described for simultaneous determination of lactone and carboxylate species of topotecan, in plasma. The method utilizes a protein precipitation step with cold methanol (-20 degrees C) for sample preparation followed by separation on a Novapack C(18) column using ammonium acetate buffer, acetonitrile and triethylamine (84:16:1.5, v/v) containing tetrabutyl ammonium hydrogen sulfate (TBAHS) (2 mM) with a pH of 5 as the mobile phase. The eluted peaks were detected by a fluorescence detector was set at an excitation wavelength of 380 nm and an emission wavelength of 527 nm. The method was validated in the range of lactone and carboxylate forms of topotecan concentrations from 0.05 to 75 ng/ml. Intra- and inter-day precision expressed by the relative standard deviation was less than 8.50% and inaccuracy did not exceed 10% for lactone and carboxylate forms of topotecan. The limit of quantitation was 0.05 ng/ml using 0.50 ml plasma. Stability studies in plasma and plasma extract indicated that topotecan is stable for at least 2 weeks at -70 degrees C.  相似文献   

13.
A simple and rapid method was developed for the extraction of proteins from both pathogenic and nonpathogenic bacteria. The method involves the treatment of cells with acetone followed by sodium dodecyl sulfate extraction of cellular proteins. Polyacrylamide gel electrophoresis revealed that the protein composition of extracts made by this method was comparable to that of extracts made by established methods, namely, sonication and agitation with beads. This technique has been successfully applied to the extraction of proteins from a wide variety of bacteria, including pathogens.  相似文献   

14.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of rivastigmine in human plasma. Rivastigmine was extracted from human plasma by using solid-phase extraction technique. Zolpidem was used as the internal standard. A Betabasic-8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 251.20-->206.10, 86.20 for rivastigmine and m/z 308.10-->235.10 for zolpidem. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatographic conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.2-20.0 ng/ml with a correlation coefficient > or =0.9988. The intra-run and inter-run precision and accuracy were within 10.0%. The overall recoveries for rivastigmine and zolpidem were 86.28% and 87.57%, respectively. The total run time was 2.0 min. The developed method was applied for the determination of the pharmacokinetic parameters of rivastigmine following a single oral administration of a 3 mg rivastigmine capsule in 20 healthy male volunteers.  相似文献   

15.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of celecoxib in human plasma. The analysis was carried out on a monolithic silica column using UV detection at 254 nm. The assay enables the measurement of celecoxib for therapeutic drug monitoring with a minimum quantification limit of 10 ng ml(-1). The method involves simple, one-step extraction procedure, and analytical recovery was 100.5 +/- 1.3%. The calibration curve was linear over the concentration range of 10-800 ng ml(-1). The coefficients of variation for inter-day and intra-day assay were found to be less than 8%. We also demonstrate the applicability of this method for pharmacokinetic studies in humans.  相似文献   

16.
Letosteine has been found to be effective in treating patients with chronic bronchopneumopathies in clinical practice. To provide robust support for its pharmacokinetic and clinical studies, a rapid and sensitive method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the analysis of letosteine in plasma samples. After protein precipitation, the plasma samples were separated on a reversed-phase C(18) column in less than 1.5 min. The LC-MS/MS system was performed in the positive ion multiple-reaction-monitoring (MRM) mode to produce intensive product ions of m/z 280.1→160.0 for letosteine and m/z 248.1→121.1 for the internal standard, tinidazole. The method was found to have excellent linearity (r ≥ 0.9974), precision (RSD ≤ 5.83%), extraction recovery (71.8-73.0%) and stability (RE, -8.45% to 9.03%) over a concentration range of 0.1140-152.0 μgL(-1). Compared to the previous published radioactive method, LC-MS/MS method showed many advantages including shorter analysis time, simpler preparation procedure, increased sensitivity as well as lower safety risks. In addition, this method was successfully applied to study the pharmacokinetics of letosteine following a single and multiple dose oral administration in Chinese healthy volunteers.  相似文献   

17.
Mackintosh JA  Veal DA  Karuso P 《Proteomics》2005,5(18):4673-4677
The development of a sensitive fluorescence-based assay for the quantitative determination of protein concentration is described. The assay is based on the natural product epicocconone, which produces a large increase in fluorescence quantum yield upon binding to detergent-coated proteins in solution. There is a concomitant shift in the emission maximum from 520 to 605 nm after binding, which results in low background signal allowing a linear dynamic range of 40 ng/mL to 200 microg/mL for most proteins. There is little protein-to-protein variation except for iron-containing proteins and the assay can be used so that it is tolerant of chemicals commonly used in 2-D sample buffers. The assay is more sensitive than standard absorption assays such as the Bradford and Lowry assays, and has a greater dynamic range and sensitivity than other fluorescent assays.  相似文献   

18.
A simple and rapid method was developed for the extraction of proteins from both pathogenic and nonpathogenic bacteria. The method involves the treatment of cells with acetone followed by sodium dodecyl sulfate extraction of cellular proteins. Polyacrylamide gel electrophoresis revealed that the protein composition of extracts made by this method was comparable to that of extracts made by established methods, namely, sonication and agitation with beads. This technique has been successfully applied to the extraction of proteins from a wide variety of bacteria, including pathogens.  相似文献   

19.
A simple, rapid, specific and sensitive high-performance liquid chromatography method has been developed for quantitation of 5-fluorouracil (5-FU) in human plasma. The method involves deproteinization of a small sample volume of plasma (150 μl) followed by HPLC on a cation-exchange resin column, Aminex HPX-87H (300×7.8 mm I.D.), preceded by a similar guard cartridge with UV detection at 265 nm. This method allows a good separation of 5-FU with a retention time of 24 min and a detection limit at 25 ng/ml. The calibration curve was linear from 25 to 2000 ng/ml. The coefficient of variation was ≤4.4% for within-day reproducibility and ≤9.5% for day-to-day reproducibility.  相似文献   

20.
Helicid is a traditional Chinese medicine used to treat headache and insomnia with definite effects. To facilitate pharmacokinetic studies of helicid in man, a sensitive and specific LC-MS/MS method for the quantitative detection of helicid in human plasma was developed and validated. The method involved the addition of bergeninum as the internal standard (IS), protein precipitation, HPLC separation, and quantification by MS/MS system using negative electrospray ionization in the multiple reaction monitoring mode (MRM). The precursor→product ion transitions were monitored at m/z 282.8→120.9 for helicid and m/z 326.9→192.2 for the IS, respectively. The lower limit of quantification (LLOQ) was 0.2 μg/L. The calibration curves for helicid was linear over a concentration range of 0.2-20 μg/L. The intra- and inter-batch analyses of QC samples at 0.4, 2, 20 μg/L indicated good precision (%R.S.D. between 2.69 and 5.47%) and accuracy (between 96.15 and 105.05%). The helicid was stable in human plasma stored at room temperature for at least 24h, 4°C for at least 24h, -20°C for at least 1 month, and for routine three freeze-thaw cycles. This accurate and specific assay provides a useful method for evaluating the pharmacokinetic profile of helicid in humans.  相似文献   