首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A highly sensitive homogeneous electrogenerated chemiluminescence (ECL) immunoassay for the determination of anti-digoxin antibody and digoxin hapten was developed employing Ru(bpy)(2)(dcbpy)NHS (bpy = 2,2'-bipyridyl; dcbpy = 2,2'-bipyridine-4,4'-dicarboxylic acid; NHS = N-hydroxysuccinimide ester) as an electrochemiluminescent label and bovine serum albumin (BSA) as a carrier protein. A digoxin hapten was indirectly heavily labelled with Ru(bpy)(2)(dcbpy)NHS through BSA to form Ru(bpy)(2)(dcbpy)NHS-BSA-digoxin conjugate. The ECL intensity of the immunocomplex of the conjugate with anti-digoxin antibody markedly decreased when the immunoreaction between Ru(bpy)(2)(dcbpy)NHS-BSA-digoxin conjugate and anti-digoxin antibody took place. Two formats, direct homogeneous immunoassay for anti-digoxin antibody and competitive immunoassay for digoxin, were developed to determine anti-digoxin antibody and digoxin, respectively. The anti-digoxin antibody concentration in the range 7.6 x 10(-8)-7.6 x 10(-6) g/mL was determined by direct homogeneous format. Digoxin hapten was determined throughout the range 4.0 x 10(-10)-1.0 x 10(-7) g/mL with a detection limit of 1.0 x 10(-10) g/mL by competitive format. The relative standard derivation for 6.0 x 10(-9) g/mL was 4.3%. The method has been applied to assaying digoxin in control human serum.  相似文献   

2.
A highly sensitive enzyme immunoassay of anti-insulin antibodies in guinea pig serum is described. Guinea pig anti-insulin serum was diluted to various extents with nonspecific guinea pig serum and incubated with insulin. After incubation, free insulin was separated from insulin-anti-insulin antibody complex by treatment with dextran-charcoal. Anti-insulin antibodies in the complex were dissociated from insulin by incubation with 0.23 M HCl and inactivated. The amount of dissociated insulin was measured by sandwich enzyme immunoassay using anti-insulin IgG-coated polystyrene balls and affinity-purified anti-insulin Fab'-horseradish peroxidase conjugate. The detection limit of anti-insulin antibodies in guinea pig serum was 6.7 pg/assay or 150 ng/liter of serum. The present enzyme immunoassay was 10,000-fold more sensitive than the previously described enzyme immunoassay, in which insulin-coated polystyrene balls were incubated with diluted guinea pig anti-insulin serum and subsequently with rabbit (anti-guinea pig IgG) Fab'-horseradish peroxidase conjugate.  相似文献   

3.
Measurement of the rate of glucose diffusion from EUDGRAGIT RL and HEMA-MMA microcapsules coupled with a Thiele modulus/Biot number analysis of the glucose utilization rate suggests that pancreatic islets and CHO (Chinese hamster ovary) cells (at moderate to high cell densities) should not be adversely affected by the diffusion restrictions associated with these capsule membranes. The mass transfer coefficients for glucose at 20 degrees C were of the same order of magnitude for both capsules, based on release measurements: approximately 5 x 10(-6) cm/s for EUDRAGIT RL and approximately 2 x 10(-6) for HEMA-MMA. Inulin release from EUDRAGIT RL was slower than for glucose (mass transfer coefficient 14 +/- 4 x 10(-8) cm/s). The Thiele moduli were much less than 1, either for a single islet at the center of a capsule or CHO cells uniformly distributed throughout a capsule at 10(-6) cells/ mL, so that diffusion restrictions within the cells in EUDRAGIT RL or 800 mum HEMA-MMA capsules should be negligible. The ratio of external to internal diffusion resistance (Biot number) was less than 1, so that at most, only a small diffusion effect on glucose utilization should be expected (i.e., the overall effectiveness factors were greater than 0.8). These calculations were consistent with experimental observation of encapsulated islet behavior but not fully with CHO cell behavior. Permeability restricted cell viability and growth is potentially a major limitation of encapsulated cells; further analysis is warranted.  相似文献   

4.
The authors describe a homogeneous, sensitive, and rapid bead-based sandwich immunoassay with a broad analytical range for quantifying insulin in human plasma. The assay was performed as a 2-step reaction by incubating the sample with a mixture of biotinylated anti-insulin antibody and beads covalently coated with anti-insulin antibody for 1 h. This was followed by incubation with beads covalently coated with streptavidin for 30 min. After the incubation steps, light generated from a chemiluminescent reaction within the beads was quantitated. The assay was run in 384-well plates with a sample volume of 5 microL. The analytical range extended from 1 to 10,000 pM. Intra-assay precision (% coefficient of variation) ranged from 1.9% to 3.8% for various insulin concentrations. Interassay precision ranged from 4.6% to 7.3%. Assay detection limit was 0.3 pM. There was no interference from moderate hemolysis (with hemoglobin up to 375 mg/dL), bilirubin (up to at least 50 mg/dL), triglyceride (up to at least 1000 mg/dL), biotin (up to at least 7.7 ng/mL), or ascorbic acid (up to 100 mg/dL). However, gross hemolysis did affect the assay. Comparable results were obtained for plasma (ethylenediamine tetra-acetic acid, citrate, and heparin treated) and serum. The correlation with enzyme-linked immunosorbent assay (ELISA) was good (y = 1.25x + 1.19, R(2) = 0.98). This method is convenient and represents an alternative to ELISA.  相似文献   

5.
A novel amplified electrochemical immunoassay based on ferrocene (Fc)-functionalized ZnO nanorods (NRs) was developed in the present work. The detection antibody ((d)Ab) and Fc were immobilized onto the surface of ZnO NRs, denoted as {(d)Ab-ZnO-Fc} bioconjugates. The amount of (d)Ab and Fc in the bioconjugates was investigated using the copper reduction/bicinchoninic acid reaction (BCA protein assay) and inductive coupled plasma-atomic emission spectroscopy (ICP-AES), respectively. Greatly amplified signal was achieved in the sandwich-type immunoassay when (d)Ab and Fc linked to ZnO NRs at a proper ratio. Using Escherichia coli (E. coli) as a model antigen, the designed immunoassay showed an excellent analytical performance, and exhibited a wide dynamic response range of E. coli concentration from 10(2) to 10(6)cfu/mL with a detection limit of 50 cfu/mL (S/N=3). By introducing a pre-enrichment step, the detection of 5 cfu/10 mL E. coli in hospital sewage water was realized. This proposed signal amplification strategy was promising and could be easily extended to monitor other biorecognition events.  相似文献   

6.
A capillary electrophoresis with electrochemical detection (CE-ED) method was developed for the simultaneous determination of four major flavonoid markers (synephrine, naringin, hesperidin and naringenin) in Frucus aurantii of different geographical origin. Operated in a wall-jet configuration, a 300 microm diameter carbon disc electrode was used as the working electrode, which exhibits a good response at +0.85 V (versus saturated calomel electrode) for the analytes. Under the optimum conditions, the analytes were baseline separated within 20 min in a 80 mmol/L borax buffer (pH 8.45). The intra-day relative standard deviations (R.S.D.) and inter-day R.S.D.s were based on the analysis of the standard solution on the same day and on the following 6 consecutive days. The intra-day R.S.D.s ranged from 0.8% (naringin) to 3.6% (hesperidin). The inter-day R.S.D.s ranged from 1.2% (hesperidin) to 4.6% (naringenin). Calibration curves were linear in ranges between 0.05 and 1000 microg/mL for the markers. Limits of detection ranged from a low of 1 x 10(-8)g/mL (hesperidin) to a high of 5 x 10(-7)g/mL (naringin). The method was successfully used in the analysis of F. aurantii of different geographical origin with relatively simple extraction procedures, and the assay results were satisfactory.  相似文献   

7.
Sensitive electrochemical immunosensor for the detection of protein biomarker tumor necrosis factor α (TNF-α) was reported that uses ferrocene carboxylic acid (Fc) functionalized self-assembled peptide nanowire (Fc-PNW) as sensor platform and glucose oxidase (GOx) modified gold nanorod (GNR) as label. Greatly enhanced sensitivity is achieved based on a dual signal amplification strategy: first, the synthesized Fc-PNW used as the sensor platform increased the loading of primary anti-TNF-α antibody (Ab(1)) onto electrode surface due to its large surface area. At the same time, the Fc moiety on the nanowire is used as a mediator for GOx to catalyze the glucose reaction. Second, multiple GOx and secondary anti-TNF-α antibody (Ab(2)) molecules are bounded onto each GNR to increase the sensitivity of the immunosensor. After the preparation of the immunosensor based on the traditional sandwich protocol, the response of the immunosensor towards glucose was used as a signal to differentiate various concentrations of TNF-α. The resulting immunosensor has high sensitivity, wide linear range (0.005-10ng/mL) and good selectivity. This immunosensor preparation strategy is a promising platform for clinical screening of protein biomarkers.  相似文献   

8.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

9.
A flow-based immunoassay system utilizing secondary-antibody coated microbeads and Cy5-secondary antibody for signal production was successfully developed to quantitate target bacteria with a kinetic exclusion assay (KinExA 3000 Instrument). It directly measured the concentration of unliganded antibody separated from the equilibrated mixture of antibody and bacteria through a 0.2 microm polyethersulfone membrane, enabling it to quantify the concentration of bacteria. The novel method demonstrated the qualities of rapidness, sensitivity, high accuracy and reproducibility, and ease to perform. Detection of Pseudomonas aeruginosa and Staphylococcus aureus was accomplished with low detection limits of 4.10 x 10(6) and 5.20 x l0(4)cells/mL, respectively, with an assay time of less than 15 min. The working ranges for quantification were 4.10 x l0(6) to 1.64 x l0(10)cells/mL for P. aeruginosa, and 5.20 x l0(4) to 1.04 x l0(9)cells/mL for S. aureus. It yielded an assay with at least 10-fold greater sensitivity than ELISA and could correctly assess the concentration of predominant bacterium spiked in the mixture of P. aeruginosa and S. aureus. With this reliable platform, the average amount of antibody bound by one cell in the maximum capability could be further provided: (1.6-2.5) x l0(5) antibodies for one P. aeruginosa cell and (2.2-2.7) x l0(8) antibodies for one S. aureus cell. The KinExA system is flexible to determine different kinds of bacteria conveniently by using anti-mouse IgG as the same immobilizing agent. However, a higher specificity of the antibodies to the target bacteria will be required for the use of this system with higher detection sensitivity.  相似文献   

10.
Muller D  Jones PM  Persaud SJ 《FEBS letters》2006,580(30):6977-6980
Insulin and glucose inhibited apoptosis in the MIN6 insulin-secreting cell line. The protective effect of 25 mM glucose was prevented by an anti-insulin antibody and this antibody-induced increase in apoptosis was reversed by the presence of excess insulin. Glucose stimulated MIN6 cell proliferation and this was inhibited by blockade of insulin secretion, by an anti-insulin antibody and by phosphatidylinositol-3 kinase (PI-3K) inhibition. Furthermore, MIN6 cell proliferation was stimulated by depolarising concentrations of KCl and by insulin itself. These data indicate that insulin secreted by β-cells in response to elevated glucose exerts autocrine effects to protect against apoptosis and stimulate proliferation, and suggest that the insulin signalling cascade, through the PI-3K pathway, may be an effective means of maintaining β-cell mass in diabetes.  相似文献   

11.
A dual microcolumn immunoassay (DMIA) was developed and applied to determination of insulin in biological samples. The DMIA utilized a protein G capillary column (150 μm I.D.) with covalently attached anti-insulin to selectively capture and concentrate insulins in a sample. Insulins retained in the capillary immunoaffinity column were desorbed and injected onto a reversed-phase capillary column (150 μm I.D.) for further separation from interferences such as cross-reactive antigens and non-specifically adsorbed sample components. Bovine, porcine and rat insulin all cross-reacted with the antibody and could be determined simultaneously. Using a UV absorbance detector, the dual microcolumn system had a detection limit of 10 fmol or 20 pM for 500-μl sample volumes. The DMIA system was used to measure glucose-stimulated insulin secretion from single rat islets of Langerhans. Because of the separation in the second dimension, both rat I and rat II insulin could be independently determined. The system was also evaluated for determination of insulin in serum. Using microcolumns instead of conventional HPLC columns resulted in several advantages including use of less chromatographic material and improved mass detection limit.  相似文献   

12.
A rapid one-step flow/stop-flow injection amperometric immunoassay for alpha-fetoprotein (AFP) using a novel home-produced electrochemical sensor was proposed. The sensor was prepared using layer-by-layer adsorption of positively charged poly(allylamine) (PAA) and negatively charged hydroxymethyl ferrocene on a screen-printed electrode (SPE). The electrochemistry of the immobilized ferrocene moieties showed a surface-controlled electrode process. Based on an electrochemical enzyme-linked immunoassay with the immobilized ferrocene moieties as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP)-labeled anti-AFP antibody, a calibration curve with two linear ranges from 5 to 20 and 20 to 150 ng ml-1 and a detection limit of 2 ng ml-1 for AFP determination was obtained under the optimized conditions of 0.891 ml min-1 flow rate, 20 microl injection volume and +25 mV applied potential. The sensor showed good repeatability and reproducibility and retained more than 95% of its original signal after 15 days of storage. The proposed method eliminated the need for washing and addition of any substrate or mediator. The complete assay could be handled in less than 25 min with a one-step injection of a 40 microl sample solution. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.  相似文献   

13.
Insulin-treated diabetics develop a heterogeneous antibody response to the protein hormone. To understand the repertoire of this diverse immune response, we developed monoclonal antibodies (Mab) that recognize idiotypic determinants on anti-insulin antibodies. Two Mab that recognize distinct idiotopes on anti-insulin antibodies were studied in detail. These idiotopes were present on IgG, but not IgM, anti-insulin antibodies from the proband and from four of 11 insulin-treated diabetics. The determinants recognized were distinct from conventional allotype (Gm) markers and were found in both Type I and Type II diabetics. The partial inhibition of anti-idiotope binding by beef insulin suggests that idiotopes related to the binding site for beef insulin may be recognized. When the presence of idiotope-positive molecules was determined sequentially during insulin therapy, in one patient, idiotope expression was found to be cyclical. In contrast, the total amount of anti-insulin antibody was constant, whereas idiotope expression varied. These data suggest that common V region determinants are employed in the anti-insulin response, and their variable expression may reflect dynamic regulation during chronic insulin therapy.  相似文献   

14.
Sodium vanadate activates "in vitro" insulin receptor autophosphorylation and protein tyrosine kinase in a dose-dependent manner. Insulin receptor protein tyrosine kinase is directly activated also by the anti-insulin receptor beta subunit monoclonal antibody 18-44. We previously demonstrated that the anti-insulin receptor monoclonal antibody MA-10 decreases insulin-stimulated receptor protein tyrosine kinase activity "in vitro", without inhibiting insulin receptor binding. In this report we show that insulin receptor protein tyrosine kinase, activated by sodium vanadate or by monoclonal antibody 18-44, is inhibited by MA-10 antibody. These data suggest that insulin receptor protein tyrosine kinase activity can be either activated and inhibited through mechanisms different from insulin binding.  相似文献   

15.
A simple and sensitive flow-injection electrogenerated chemiluminescence (ECL) method for the determination of fluoroquinolones was developed. The method is based on the sensitizing effect of fluoroquinolones on the weak ECL signal of electrochemical oxidation of luminol on the surface of the platinum flake electrode in the medium of 0.1 mol/L Na2CO3-NaHCO3. At the optimum experimental conditions, the relative ECL intensity increased linearly with increasing fluoroquinolones concentration, in the ranges 1.0 x 10(-8)-2.0 x 10(-4) g/mL for norfloxacin, 5.0 x 10(-9)-6.0 x 10(-6) g/mL for oxfloxacin, 2.0 x 10(-8)-1.4 x 10(-5) g/mL for ciprofloxacin, 1.0 x 10(-8)-1.4 x 10(-5) g/mL for pefloxacin, and 1.0 x 10(-9)-1.0 x 10(-5) g/mL for enoxacin, with detection limits of 4.0 x 10(-9) g/mL, 2.0 x 10(-9) g/mL, 1.0 x 10(-8) g/mL, 8.0 x 10(-9) g/mL, and 8.0 x 10(-10) g/mL, respectively. The relative standard deviations were all less than 2.5% for the determination of 2.0 x 10(-6) g/mL fluoroquinolones (n = 11). The method was used to determine these medicines in pharmaceutical samples with satisfactory results.  相似文献   

16.
An enzyme immunoassay of anti-insulin IgG in guinea pig serum was improved in sensitivity by reducing the non-specific binding of normal guinea pig IgG and enhancing the specific binding of anti-insulin IgG. Silicone rubber pieces or polystyrene balls were coated with normal rabbit IgG, followed by coupling of insulin using glutaraldehyde. The insulin-normal rabbit IgG-coated silicone rubber pieces or polystyrene balls were incubated with normal rabbit IgG and then with diluted guinea pig anti-insulin serum in the presence of normal rabbit IgG at a lower temperature (20 degrees C). Finally, the solid phases were incubated with rabbit (anti-guinea pig IgG) Fab'-horseradish peroxidase conjugate to measure the amount of guinea pig IgG bound. The detection limit of anti-insulin IgG in guinea pig serum was improved 10 to 100-fold compared to that of enzyme immunoassay performed by incubating insulin-bovine serum albumin-coated solid phases with diluted guinea pig anti-insulin serum at 37 degrees C and then with rabbit (anti-guinea pig IgG) Fab' conjugated to beta-D-galactosidase from Escherichia coli, according to a previous report (Kato, K., et al. (1978) J. Biochem. 84, 93-102).  相似文献   

17.
Du D  Ju H  Zhang X  Chen J  Cai J  Chen H 《Biochemistry》2005,44(34):11539-11545
A strategy to detect P-glycoprotein (P-gp) on cell membrane and quantify the cell number using electrochemical immunoassay was developed by effective surface immunoreactions and immobilization of cells on a highly hydrophilic interface, which was constructed by adsorption of colloidal gold nanoparticles on a methoxysilyl-terminated (Mos) butyrylchitosan modified glassy carbon electrode (Au-CS/GCE). Atomic force microscopy studies proved that the nanoparticles adsorbed on Mos-butyrylchitosan were efficient in preventing the cell leakage and retaining the activity of immobilized living K562/ADM leukemic cells. The incubation with P-gp monoclonal antibody and then the secondary alkaline phosphatase (AP) conjugated antibody introduced AP onto the K562/ADM cell immobilized on Au-CS/GCE. The bound AP led to an amperometric response of 1-naphthyl phosphate. Under optimal conditions the response was proportional to the logarithm of cell concentration in the range from 5.0 x 10(4) to 1.0 x 10(7) cells mL(-)(1) with a detection limit of 1.0 x 10(4) cells mL(-)(1). The results were comparable to flow cytometric analysis of P-gp expression. This proposed method was practical, convenient, and significant in the clinic and cytobiology.  相似文献   

18.
In this paper, a novel electrochemical immunosensor for the determination of casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes (P-L-Arg/MWCNTs) composite film was proposed. The P-L-Arg/MWCNTs composite film was used to modify glassy carbon electrode (GCE) to fabricate P-L-Arg/MWCNTs/GCE through electropolymerization of L-Arginine on MWCNTs/GCE. Gold nanoparticles were adsorbed on the modified electrode to immobilize the casein antibody and to construct the immunosensor. The stepwise assembly process of the immunosensor was characterized by cyclic voltammetry and differential pulse voltammetry. Results demonstrated that the peak currents of [Fe(CN)(6)](3-/4-) redox pair decreased due to the formation of antibody-antigen complex on the modified electrode. The optimization of the adsorption time of gold nanoparticles, the pH of supporting electrolyte and the incubation time were investigated in details. Under optimal conditions, the peak currents obtained by DPV decreased linearly with the increasing casein concentrations in the range from 1 × 10(-7) to 1 × 10(-5) g mL(-1) with a linear coefficiency of 0.993. This electrochemical immunoassay has a low detection limit of 5 × 10(-8) g mL(-1) and was successfully applied to the determination of casein in cheese samples.  相似文献   

19.
A series of 8-(ferrocenylalkyl)theophylline conjugates were synthesized for evaluation in a homogeneous, competitive electrochemical immunoassay for theophylline with amperometric detection of the ferrocene label at +320 mV. The electrical signal was amplified via redox cycling with the glucose oxidase/glucose system. The resulting catalytic current was strongly inhibited upon binding of the conjugates to anti-theophylline antibodies such that a large excess of theophylline was required to achieve complete reversal leading to an assay with poor sensitivity in the clinical range. A study of the nonspecific interaction of the antibodies with various ferrocene derivatives indicated that this was reduced when a charged functional group was present on the metallocene ring. Consequently, a conjugate was synthesized with a quaternary ammonium group which when incorporated into the assay resulted in improved sensitivity.  相似文献   

20.
A novel, sensitive electrochemical immunoassay has been developed based on the precipitation of silver on colloidal gold labels which, after silver metal dissolution in an acidic solution, was indirectly determined by anodic stripping voltammetry (ASV) at a glassy-carbon electrode. The method was evaluated for a noncompetitive heterogeneous immunoassay of an immunoglobulin G (IgG) as a model. The influence of relevant experimental variables, including the reaction time of antigen with antibody, the dilution ratio of the colloidal gold-labeled antibody and the parameters of the anodic stripping operation, upon the peak current was examined and optimized. The anodic stripping peak current depended linearly on the IgG concentration over the range of 1.66 ng ml(-1) to 27.25 microg ml(-1) in a logarithmic plot. A detection limit as low as 1 ng ml(-1) (i.e., 6 x 10(-12) M) human IgG was achieved, which is competitive with colorimetric enzyme linked immuno-sorbent assay (ELISA) or with immunoassays based on fluorescent europium chelate labels. The high performance of the method is attributed to the sensitive ASV determination of silver (I) at a glassy-carbon electrode (detection limit of 5 x 10(-9) M) and to the catalytic precipitation of a large number of silver on the colloidal gold-labeled antibody.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号