首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bacteriophages and enteroviruses in water were adsorbed to positively charged filters (Virosorb 1MDS [AMF Cuno, Inc., Meriden, Conn.] or Seitz S [Republic Filters, Milldaler, Conn.]). Adsorbed viruses were eluted by treating the filters with 10% beef extract, pH 9. Organic flocculation of the beef extract at pH 3.5 permitted recovery of more than 40% of the enteroviruses tested but less than 15% of the bacteriophages present. A method was developed that uses salts at pH 7 to flocculate beef extract. Two volumes of saturated ammonium sulfate were added to beef extract, and both enteroviruses and bacteriophages were adsorbed to the flocs that formed. Greater than 70% of the enteroviruses and bacteriophages were recovered by centrifuging the sample and suspending the flocs in a small volume of distilled water.  相似文献   

2.
The survival of enteric viruses (poliovirus type 1, Mahoney strain, and indigenous viruses of waste waters) has been studied after adsorption of the viruses (pH 3.5) on glass microfiber filters. After postal transport, the presence of the viruses was checked on the filters being soaked in a 3% beef extract solution (pH 7.5) either frozen or without protection against heat. Viruses were recovered at a rate of 59 to 65%. For qualitative studies, postal shipment of samples adsorbed on fiberglass may allow extension of a control system for enteroviruses in water.  相似文献   

3.
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

4.
Poliovirus concentration from tap water with electropositive adsorbent filters   总被引:10,自引:0,他引:10  
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

5.
The 1-MDS Virosorb filter and the 50S and 30S Zeta-plus filters, all with a net positive charge, were compared with the negatively charged Filterite filter for concentration of naturally occurring coliphages and animal viruses from sewage effluent. When Filterite filters were used, the effluent was adjusted to pH 3.5 and AlCl3 was added before filtration to facilitate virus adsorption. No adjustment was required with the positively charged filters. Sets of each filter type were eluted with 3% beef extract (pH 9.5) or eluted with 0.05 M glycine (pH 11.5). A maximum volume of 19 liters could be passed through 142-mm diameter Filterite filters before clogging, whereas only 11, 11, and 15 liters could be passed through the 1-MDS, 50S, and 30S filters, respectively. For equal volumes passed through the filters, coliphage recoveries were 14, 15, 18, and 37% in primary effluent and 40, 97, 50, and 46% in secondary effluent for the Filterite , 1-MDS, 50S, and 30S filters, respectively. No statistically significant difference was observed in the recovery of animal viruses among the filters from secondary effluent, whereas in the Filterite and 50S filters, higher numbers of viruses from primary effluent were recovered than in the 1-MDS and 30S filters in two of three collections. Glycine was found to be a less-efficient eluent than beef extract in the recovery of naturally occurring viruses.  相似文献   

6.
The 1-MDS Virosorb filter and the 50S and 30S Zeta-plus filters, all with a net positive charge, were compared with the negatively charged Filterite filter for concentration of naturally occurring coliphages and animal viruses from sewage effluent. When Filterite filters were used, the effluent was adjusted to pH 3.5 and AlCl3 was added before filtration to facilitate virus adsorption. No adjustment was required with the positively charged filters. Sets of each filter type were eluted with 3% beef extract (pH 9.5) or eluted with 0.05 M glycine (pH 11.5). A maximum volume of 19 liters could be passed through 142-mm diameter Filterite filters before clogging, whereas only 11, 11, and 15 liters could be passed through the 1-MDS, 50S, and 30S filters, respectively. For equal volumes passed through the filters, coliphage recoveries were 14, 15, 18, and 37% in primary effluent and 40, 97, 50, and 46% in secondary effluent for the Filterite , 1-MDS, 50S, and 30S filters, respectively. No statistically significant difference was observed in the recovery of animal viruses among the filters from secondary effluent, whereas in the Filterite and 50S filters, higher numbers of viruses from primary effluent were recovered than in the 1-MDS and 30S filters in two of three collections. Glycine was found to be a less-efficient eluent than beef extract in the recovery of naturally occurring viruses.  相似文献   

7.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

8.
Four enteric viruses, poliovirus type 1, echovirus type 1, reovirus type 3, and simian adenovirus SV-11, were concentrated from seeded 1.3-liter volumes of raw, finished, and granular activated carbon-treated waters by adsorption to 47-mm-diameter (17 cm2), electropositive ( Virosorb 1MDS ) filters at pH 7.5 or electronegative ( Filterite ) filters at pH 3.5 with and without 5 mM added MgCl2, followed by elution with 0.3% beef extract in 50 mM glycine at pH 9.5. Removal of particulates from raw and finished waters by 0.2-micron prefiltration before virus addition and pH adjustment had little effect on virus concentration efficiencies. Soluble organic compounds reduced virus adsorption efficiencies from both raw and finished waters compared with granular activated carbon-treated water, but the extent of interference varied with virus type and adsorption conditions. For electropositive 1MDS filters, organic interference was similar with all virus types. For Filterite filters, organic interference was evident with poliovirus and echovirus, but could be overcome by adding MgCl2. Reovirus and SV-11 were not adversely affected by organics during adsorption to Filterite filters. Elution of reovirus and adenovirus was inefficient compared with that of poliovirus and echovirus. None of the three adsorption schemes ( 1MDS at pH 7.5 and Filterite with and without 5 mM MgCl2 at pH 3.5) could be judged superior for all viruses and water types tested.  相似文献   

9.
Pig erythrocyte membranes were used as adsorbent material for the concentration of bacteriophage phi x-174, MS-2, and f2 from 5 ml of saline solution. The adsorption was carried out at pH 3.5, and the elution was carried out at pH 7.0. Compared with adsorption on 3% beef extract, bacteriophage adsorption on erythrocyte ghost cells yielded 93 to 100%, and elution was 92 to 100%, whereas beef extract organic flocculation yielded adsorption of 0 to 98.8% and elution of 61 to 86.6%. The same procedure but with poliovirus LSC-1 gave 100% adsorption and 91 to 129% elution.  相似文献   

10.
R Armon  Y Kott    I Neeman 《Applied microbiology》1984,47(6):1337-1340
Pig erythrocyte membranes were used as adsorbent material for the concentration of bacteriophage phi x-174, MS-2, and f2 from 5 ml of saline solution. The adsorption was carried out at pH 3.5, and the elution was carried out at pH 7.0. Compared with adsorption on 3% beef extract, bacteriophage adsorption on erythrocyte ghost cells yielded 93 to 100%, and elution was 92 to 100%, whereas beef extract organic flocculation yielded adsorption of 0 to 98.8% and elution of 61 to 86.6%. The same procedure but with poliovirus LSC-1 gave 100% adsorption and 91 to 129% elution.  相似文献   

11.
Electronegative microporous filters composed of epoxyfiberglass (Filterite) were treated with cationic polymers to enhance their virus-adsorbing properties. This novel and inexpensive approach to microporous filter modification entails soaking filters in an aqueous solution of a cationic polymer such as polyethyleneimine (PEI) for 2 h at room temperature and then allowing the filters to air dry overnight on absorbent paper towels. PEI-treated filters were evaluated for coliphage (MS2, T2, and phi X174) and enterovirus (poliovirus type 1 and coxsackievirus type B5) adsorption from buffer at pH 3.5 to 9.0 and for indigenous coliphages from unchlorinated secondary effluent at ambient pH. Adsorbed viruses were recovered with 3% beef extract (pH 9). Several other cationic polymers were used to modify epoxyfiberglass filters and were evaluated for their ability to concentrate viruses from water. Zeta potentials of disrupted filter material indicated that electronegative epoxyfiberglass filters were made more electropositive when treated with cationic polymers. In general, epoxyfiberglass filters treated with cationic polymers were found to adsorb a greater percentage of coliphages and enteroviruses than were untreated filters.  相似文献   

12.
Electronegative microporous filters composed of epoxyfiberglass (Filterite) were treated with cationic polymers to enhance their virus-adsorbing properties. This novel and inexpensive approach to microporous filter modification entails soaking filters in an aqueous solution of a cationic polymer such as polyethyleneimine (PEI) for 2 h at room temperature and then allowing the filters to air dry overnight on absorbent paper towels. PEI-treated filters were evaluated for coliphage (MS2, T2, and phi X174) and enterovirus (poliovirus type 1 and coxsackievirus type B5) adsorption from buffer at pH 3.5 to 9.0 and for indigenous coliphages from unchlorinated secondary effluent at ambient pH. Adsorbed viruses were recovered with 3% beef extract (pH 9). Several other cationic polymers were used to modify epoxyfiberglass filters and were evaluated for their ability to concentrate viruses from water. Zeta potentials of disrupted filter material indicated that electronegative epoxyfiberglass filters were made more electropositive when treated with cationic polymers. In general, epoxyfiberglass filters treated with cationic polymers were found to adsorb a greater percentage of coliphages and enteroviruses than were untreated filters.  相似文献   

13.
Microbiological- and food-grade beef extracts, protein hydrolytic, enzymatic and autolytic digestion products, and whole protein materials were examined for their potential effectiveness for eluting adsorbed enteroviruses from membrane filters with observed efficiencies ranging from less than 1 to 69%. Concentration of enteroviruses from solutions of these protein and protein-derived products by organic flocculation ranged in efficiency from 2 to 125%. Both elution and concentration were dependent upon virus type, as well as nature, source, and production lot of the material being tested. Determining the efficiency of virus concentration was complicated by virus aggregation and apparent virus inactivation by low pH. Effectiveness of concentrating viruses by organic flocculation from solutions prepared with the various test materials seemed independent of the amount of precipitate produced during the flocculation procedure. Quality assurance tests were proposed by which solutions prepared from beef extracts, whole protein, and protein-derived materials could be evaluated for use in eluting adsorbed viruses from membrane filters and for concentrating viruses by organic flocculation. Food-grade beef extract seemed equal to microbiological-grade beef extract in terms of both virus elution and concentration. Several of the nonbeef extract materials evaluated were as effective as beef extract for virus concentration, but were less effective for virus elution.  相似文献   

14.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

15.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

16.
By using recently developed cultivation and assay systems, currently available methods for concentrating enteric viruses from drinking water by adsorption to and subsequent elution from microporous filters followed by organic flocculation were evaluated for their ability to recover hepatitis A virus (HAV). Cell culture-adapted HAV (strain HM-175) in seeded tapwater was efficiently adsorbed by both electronegative (Filterite) and electropositive (Virosorb 1MDS) filters at pH and ionic conditions previously used for other enteric viruses. Adsorbed HAV was efficiently eluted from these filters by beef extract eluents at pH 9.5. Eluted HAV was further concentrated efficiently by acid precipitation (organic flocculation) of eluents containing beef extract made from powdered, but not paste, sources. By using optimum adsorption conditions for each type of filter, HAV was concentrated greater than 100-fold from samples of seeded tapwater, with about 50% recovery of the initial infectious virus added to the samples. The ability to recover and quantify HAV in contaminated drinking water with currently available methods should prove useful in further studies to determine the role of drinking water in HAV transmission.  相似文献   

17.
By using recently developed cultivation and assay systems, currently available methods for concentrating enteric viruses from drinking water by adsorption to and subsequent elution from microporous filters followed by organic flocculation were evaluated for their ability to recover hepatitis A virus (HAV). Cell culture-adapted HAV (strain HM-175) in seeded tapwater was efficiently adsorbed by both electronegative (Filterite) and electropositive (Virosorb 1MDS) filters at pH and ionic conditions previously used for other enteric viruses. Adsorbed HAV was efficiently eluted from these filters by beef extract eluents at pH 9.5. Eluted HAV was further concentrated efficiently by acid precipitation (organic flocculation) of eluents containing beef extract made from powdered, but not paste, sources. By using optimum adsorption conditions for each type of filter, HAV was concentrated greater than 100-fold from samples of seeded tapwater, with about 50% recovery of the initial infectious virus added to the samples. The ability to recover and quantify HAV in contaminated drinking water with currently available methods should prove useful in further studies to determine the role of drinking water in HAV transmission.  相似文献   

18.
The efficiency of the adsorption-elution technique using fiber glass filters to concentrate viruses from water was evaluated to detect poliovirus type 1 in drinking, river, and sewage water. At pH 3.5 and with 5 X 10(-4) M aluminium chloride more than 99% were adsorbed at a 0.25-micron filter. Beef extract (3%), pH 9, eluted 85-95% of the adsorbed viruses and organic flocculation at pH 3.5 permitted to reconcentrate the viruses in 1/20 of the elution volume with a 50-72% efficiency. The overall efficiency of the technique for 100 ml to 1000 l of the different types of water using 10(2) to 10(6) PFU was 38 to 58%.  相似文献   

19.
Washing, freon extraction, and cationic polyelectrolyte precipitation were compared for their ability to reduce cytotoxicity associated with virus concentrates derived from beef extract eluates of wastewater sludges. Eluates concentrated by hydroextraction were usually much more toxic than those concentrated by organic flocculation. This difference may be due entirely to nondialyzable material naturally present in the beef extract which did not precipitate during flocculation at pH 3.5. Washing inoculated cell monolayers with saline containing calf serum before the addition of agar overlay media was most effective in reducing cytotoxicity, although it resulted in a greater virus loss, as compared with freon extraction and cationic polyelectrolyte precipitation.  相似文献   

20.
Washing, freon extraction, and cationic polyelectrolyte precipitation were compared for their ability to reduce cytotoxicity associated with virus concentrates derived from beef extract eluates of wastewater sludges. Eluates concentrated by hydroextraction were usually much more toxic than those concentrated by organic flocculation. This difference may be due entirely to nondialyzable material naturally present in the beef extract which did not precipitate during flocculation at pH 3.5. Washing inoculated cell monolayers with saline containing calf serum before the addition of agar overlay media was most effective in reducing cytotoxicity, although it resulted in a greater virus loss, as compared with freon extraction and cationic polyelectrolyte precipitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号