首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method for the extraction of microcystins RR and LR in cyanobacteria was developed using a cyano cartridge. Lyophilized cells (100 mg) were extracted with 5% (v/v) acetic acid. The extract was centrifuged and then the supernatant was applied to a CN cartridge. The cartridge that contained microcystins was rinsed with 5 ml of water and 5 ml of 0.5 M acetic acid, followed by 5 ml of 5% acetonitrile in water. Microcystins were finally eluted from the CN cartridge with 70% acetonitrile in water and were determined by HPLC. Better recoveries and chromatograms were observed than with ODS cartridges.  相似文献   

2.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantification of donepezil, a centrally and selectively acting acetyleholinesterase inhibitor, in human plasma. After sample alkalinization with 0.5 ml of NaOH (0.1 M), the test compound was extracted from I ml of plasma using isopropanol-hexane (3:97, v/v). The organic phase was back-extracted with 75 microl of HCl (0.1 M) and 50 microl of the acid solution was injected into a C18 STR ODS-II analytical column (5 microm, 150x4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.02 M, pH 4.6), perchloric acid (6 M) and acetonitrile (59.5:0.5:40, v/v) and was delivered at a flow-rate of 1.0 ml/min at 40 degrees C. The peak was detected using a UV detector set at 315 nm, and the total time for a chromatographic separation was approximately 8 min. The method was validated for the concentration range 3-90 ng/ml. Mean recoveries were 89-98%. Intra- and inter-day relative standard deviations were less than 7.3 and 7.6%, respectively, at the concentrations ranging from 3 to 90 ng/ml. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

3.
A simple, rapid and sensitive method for determination of rivastigmine in plasma samples was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography with mass spectrometry (GC-MS). The optimum conditions for the SPME procedure were: headspace extraction on a 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber; 0.5 ml of plasma modified with 1.0 ml of sodium hydroxide-sodium carbonate solution (0.7 M:0.5M); extraction temperature of 100 degrees C, with stirring at 2000 rpm for 30 min. The calibration curve showed linearity in the range from 0.2 to 80 ng/ml with regression coefficient corresponding to 0.9965 and coefficient of the variation of the points of the calibration curve lower than 10%. The quantification limit for rivastigmine in plasma was 0.2 ng/ml. The method was applied to determination of rivastigmine in canine plasma samples from animals after a single oral administration.  相似文献   

4.
A sensitive and specific method for the determination of 17alpha-hydroxyprogesterone caproate (17-OHPC) in human plasma using high-performance liquid chromatography and mass spectrometry has been developed and validated. Plasma samples were processed by a solid phase extraction (SPE) procedure using Oasis HLB extraction cartridge prior to chromatography. Medroxyprogesterone acetate (MPA) was used as the internal standard. Chromatography was performed using Waters C18 Symmetry analytical column, 3.5 microm, 2.1 mm x 10 mm, using a gradient elusion with a mobile phase consisting of acetonitrile [A] and 5% acetonitrile in water [B], with 0.1% formic acid being added to both [A] and [B], at a flow rate 0.2 ml/min. The retention times of 17-OHPC and MPA were 8.1 and 5.0 min, respectively, with a total run time of 15 min. Analysis was performed on Thermo Electron Finnigan TSQ Quantum Ultra mass spectrometer in a selected reaction-monitoring (SRM), positive mode using electron spray ionization (ESI) as an interface. Positive ions were measured using extracted ion chromatogram mode. The extracted ions following SRM transitions monitored were m/z 429.2-->313.13 and 429.2-->271.1, for 17-OHPC and m/z 385.1-->276 for MPA. The extraction recoveries at concentrations of 5, 10 and 50 ng/ml were 97.1, 92.6 and 88.7%, respectively. The assay was linear over the range 0.5-50 ng/ml for 17-OHPC. The analysis of standard samples for 17-OHPC 0.5, 1, 2.5, 5, 10, 25 and 50 ng/ml demonstrated a relative standard deviation of 16.7, 12.4, 13.7, 1.4, 5.2, 3.7 and 5.3%, respectively (n=6). This method is simple, adaptable to routine application, and allows easy and accurate measurement of 17-OHPC in human plasma.  相似文献   

5.
A sensitive and relatively rapid reversed-phase HPLC method was applied to the enantiomeric separation of tramadol and its two main metabolites, O-desmethyltramadol (M1) and N-desmethyltramadol (M2) in plasma samples. Chromatography was performed on an AGP column containing alpha1-acid glycoprotein as chiral selector with a mobile phase of 30 mM diammonium hydrogen phosphate buffer-acetonitrile-triethylamine (98.9:1:0.1, v/v), adjusted to pH 7 by phosphoric acid, and a flow rate of 0.5 ml/min. The fluorescence of analytes was detected at excitation and emission wavelengths of 200 and 301 nm, respectively. The sample preparation was a simple extraction with ethyl acetate using fluconazol as internal standard (IS). The enantiomers of all analytes and IS peaks eluted within 32 min, without any endogenous interference. The calibration curves were linear (r(2) > 0.993) in the concentration range of 2-200, 2.5-100 and 2.5-75 ng/ml for tramadol, M1, and M2 enantiomers, respectively. The within- and between-day variation determined by the measurement of quality control samples at four tested concentrations, showed acceptable values. The lower limit of quantitation was 2 ng/ml for tramadol enantiomers and 2.5 ng/ml for M1 or M2 enantiomers. Mean recoveries of enantiomers from plasma samples were > 81% for all analytes. The procedure was applied to assess the pharmacokinetics of the enantiomers of tramadol and its two main metabolites following oral administration of single 100-mg doses to healthy volunteers.  相似文献   

6.
We have developed a solid phase extraction procedure for the detection of organic acids by GC-MS using a strong anion exchange column (Sep-Pak Vac RC, Accell Plus QMA cartridge). Extraction efficiencies of 25 organic acids were established by analyzing standards in water based solutions. High extraction efficiencies (90 to 100%) were found for many of the compounds studied. We estimated the limit of detection for 48 organic acids and glycine conjugates. They were below 5 nmole with the exception of malonic and oxalic acids and mevalonic acid lactone. This method provides the advantage of higher recoveries for a wide range of compounds of interest and therefore can be a potential alternative to liquid-liquid extraction for organic acid screening. It is especially sensitive for the detection of some polar compounds, such as 3-OH-glutaric and N-acetylaspartic acids.  相似文献   

7.
A sensitive and selective LC-MS-MS method for the determination of DPC 423 (I), an antithrombotic agent, is described. This method used a solid-phase extraction from 0.1 ml plasma with an Isolute C(2) cartridge. HPLC separation was carried out on a YMC ODS-AQ C(18) column (50x2 mm) at a flow-rate of 300 microliter/min with an analysis time of 5 min. Compounds were eluted using a mobile phase of H(2)O/CH(3)CN/HCOOH: 66:34:0.1 (v/v/v), pH 4.0. A structural analogue of I was used as the internal standard to account for variations in recovery and instrument response. Mass spectrometric detection was carried out with a PE Sciex API III(+) triple quadrupole mass spectrometer equipped with a Turbo IonSpray source as the LC-MS interface. Good intra-day and inter-day assay precision (<10% CV) and accuracy (<10% difference) were observed over a concentration range of 0.005-2.5 microM in plasma. The extraction recoveries were approximately 90% and the method was found to be linear for the assay (r(2)>0.999). The method has been successfully applied to discovery and preclinical pharmacokinetic studies, including a dose range-finding study and toxicokinetic exposure studies in rat and dog.  相似文献   

8.
A system of an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatograph-mass spectrometer (GC–MS) was developed for the simultaneous analysis of seven barbiturates in human serum. A sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading 1.5 ml of a diluted serum sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into the GC–MS. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.1 to 10 μg ml−1 for all barbiturates extracted. The proposed method was applied to 27 clinical serum samples from three patients who were administrated secobarbital.  相似文献   

9.
A system for an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatography–mass spectrometry (GC–MS) system was developed for the simultaneous analysis of seven barbiturates in human urine. Sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading a 1.5 ml volume of a urine sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into a GC–MS system. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.02 to 10 μg/ml for all barbiturates extracted. The proposed method was applied to several clinical cases. The total analysis time for 20 samples was approximately 14 h.  相似文献   

10.
Chloramphenicol (CAP) is subjected to monitoring in food products, with a minimum required performance level set at 0.3 ng/g. CAP was isolated from chicken meat and seafood by very simple solvent extraction procedure. For honey, a fast SPE procedure was applied. CAP-D5 was used as internal standard. HPLC separation was done on RP18 123 mm x 3 mm column in acetonitrile-ammonium formate 10 mM, pH 3.0 (40:60) at flow rate of 0.3 ml/min. A TSQ Quantum instrument with ESI source has been used in negative ionization mode. A MRM procedure has been applied and following transitions were monitored: m/z 321 > 152 (quantifier), 321 > 194, 321 > 257(qualifiers), 326 > 157 (IS). CAP peak was eluted at around 5 min; the total run time was 7 min. LOD was around 0.1 ng/g meat or 0.05 ng/g honey. Matrix effects were studied for all materials used, involving injection of blank extracts with post-column infusion of CAP, as well as checking the influence of the co-injected blank extracts on the signal intensity of CAP. No influence of matrix on the results of CAP determination were observed. The method allows analyzing up to 30 duplicate samples per day, including all calibration standards. Additionally, the method for determination of CAP glucuronide (CAP-G) was established, using urine from rats that were given this drug as a source of the metabolite. Full validation of the metabolite was not possible, due to the unavailability of reference standard.  相似文献   

11.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)–electrospray ionization mass spectrometry (HPLC–ESI–MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.×150 mm) for HPLC separation and ESI–MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile–10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10–20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users’ urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

12.
The efficiency of poliovirus elution from fiber glass cartridge filters (K27), epoxy-fiber glass-asbestos filters (M780), and pleated cartridge filters was assessed by using 3% beef extract (pH 9.0) or 0.1 M glycine (pH 11.5). Poliovirus type I, strain LSc, was seeded into 20- to 25-gallon (ca. 75.6- to 95.6-liter) samples of treated sewage effluent and concentrated by using a filter adsorption-elution technique. Virus elution was accomplished by using either two 600-ml portions of 3% beef extract (pH 9.0), or two 1-liter portions of 0.1 M glycine (pH 11.5). In all experiments, beef extract elution followed by organic flocculation was found to be superior, yielding a mean recovery efficiency of 85%, with recoveries ranging from 68 to 100%. Elution with 0.1 M glycine (pH 11.5) followed by inorganic flocculation resulted in a mean recovery efficiency of 36%. The variable range of recoveries with beef extract could not be significantly improved by varying the type of beef extract or by extending the elution time to 30 min. Second-step reconcentration of 1-liter seeded sewage effluent and renovated wastewater samples indicated that organic flocculation was a more efficient method for virus recovery than inorganic flocculation. Beef extract concentrations of less than 3% were found to be efficient in the recovery of poliovirus from renovated wastewater.  相似文献   

13.
The efficiency of poliovirus elution from fiber glass cartridge filters (K27), epoxy-fiber glass-asbestos filters (M780), and pleated cartridge filters was assessed by using 3% beef extract (pH 9.0) or 0.1 M glycine (pH 11.5). Poliovirus type I, strain LSc, was seeded into 20- to 25-gallon (ca. 75.6- to 95.6-liter) samples of treated sewage effluent and concentrated by using a filter adsorption-elution technique. Virus elution was accomplished by using either two 600-ml portions of 3% beef extract (pH 9.0), or two 1-liter portions of 0.1 M glycine (pH 11.5). In all experiments, beef extract elution followed by organic flocculation was found to be superior, yielding a mean recovery efficiency of 85%, with recoveries ranging from 68 to 100%. Elution with 0.1 M glycine (pH 11.5) followed by inorganic flocculation resulted in a mean recovery efficiency of 36%. The variable range of recoveries with beef extract could not be significantly improved by varying the type of beef extract or by extending the elution time to 30 min. Second-step reconcentration of 1-liter seeded sewage effluent and renovated wastewater samples indicated that organic flocculation was a more efficient method for virus recovery than inorganic flocculation. Beef extract concentrations of less than 3% were found to be efficient in the recovery of poliovirus from renovated wastewater.  相似文献   

14.
Solid-phase microextraction (SPME) is a unique extraction and sampling technique, and it has been used for separation of volatile organics from water or other simple matrices. In this study, we have used SPME to separate dinitroaniline herbicides from complicated matrices of human urine and blood in order to broaden its application to biomedical analysis. The SPME conditions were optimized for water, urine and blood samples, in terms of pH, salt additives, extraction temperature, and fiber exposure time. Urine or water (1.0 ml) spiked with herbicides and 0.28 g of anhydrous sodium sulfate was preheated at 70°C for 10 min, and a polydimethylsiloxane-coated fiber for SPME was exposed to the headspace at 70°C for another 30 min; while spiked blood (0.5 ml) diluted with water (0.5 ml) was treated at 90°C in the same way. The herbicides were extractable under these conditions, and could be determined by gas chromatography–electron capture detector (GC–ECD). The recoveries of the herbicides, measured at the concentrations of 0.50 and 1.0 ng/ml urine or water, or 6.0 and 20 ng/0.5 ml blood, ranged from 35 to 64% for different herbicides from water or urine, and from 3.2 to 7.2% from blood. The headspace SPME yielded clean extracts of dinitroaniline herbicides from urine, blood or water, which could be directly analyzed by GC–ECD without further purification. The peak areas of the extracted herbicides were proportional to their concentrations in the range 0.1–10 ng/ml in water or urine, or 1–60 ng/0.5 ml in blood. The lowest detectable concentration of the herbicides lay in 0.1 ng/ml water or urine, or in 0.5 ng/0.5 ml blood. The intra- and inter-day coefficients of variation were within 14% for most of the analytes. Although the recoveries of the herbicides were rather low, the linearity of calibration curve and the precision were good. The developed method is more sensitive and much simpler in sample preparation than previously reported ones. With the established SPME method, a dosed herbicide was successfully separated and determined in rats' blood.  相似文献   

15.
A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.  相似文献   

16.
A solid-phase extraction method using Drug Test-1 column containing chemically modified silica as a solid support for sample clean up and reversed phase ion-paired high-pressure liquid chromatography method have been developed for the simultaneous determination of nicotine and its metabolite cotinine from the urine samples. Mobile phase was consisted of acetate buffer (containing 0.03 M sodium acetate and 0.1 M acetic acid) pH 3.1 and acetonitrile (78:22% (v/v)) containing 0.02 M sodium octanosulfonate as an ion pair agent. pH of the mobile phase was adjusted to 3.6 with triethylamine for better resolution and to prevent peak tailing. The linearity was obtained in the range of 0.5-10 microg/ml concentrations of nicotine and cotinine standards. The correlation coefficients were 0.998 for cotinine and 0.999 for nicotine. The recoveries were obtained in the range of 79-97% with average value of 85% for nicotine and in the range of 82-98% with average value of 88% for cotinine. The limit of detection was 2 ng/ml for cotinine and 5 ng/ml for nicotine with 2 ml urine for extraction, calculated by taking signal to noise ratio 10:3. The intra-day co-efficient of variation (CV) were <4 and 7% and inter-day CV were <9 and 7% for nicotine and cotinine, respectively. The method was applied to the urine samples of tobacco harvesters, who suffer from green tobacco sickness (GTS) to check the absorption of nicotine through dermal route during the various processes of tobacco cultivation due to its good reproducibility and sensitivity.  相似文献   

17.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

18.
Salicylic acid (0.5 mM) is used as a trapping reagent of hydroxyl radical, and the formed 2,3- and 2,5-dihydroxybenzoic acids were collected via an on-line microdialysis device from the blood vessels. This study revealed the use of a sensitive liquid chromatographic system with electrochemical detection for the determination of 2,3- and 2,5-dihydroxybenzoic acids. Mobile phase consisted of 0.1 M monochloroacetic acid, 10 mM EDTA, 0.5 mM sodium octylsulfate, 20% acetonitrile and 5% tetrahydrofuran in 1 l (pH 3.0 adjusted with 1 M NaOH), and the flow-rate of 0.05 ml/min were found to be optimum. Isocratic separation of these adducts on a microbore column (reversed-phase C18, 150×1 mm I.D., 5 μm) was achieved within 10 min. The optimal applied potential of dihydroxybenzoic acids was set at 750 mV based on a hydrodynamic study. This method has the detection limits of 1.3 pmol/ml (or 0.2 ng/ml) for 2,3- and 2,5-dihydroxybenzoic acids in Ringer solution (at signal-to-noise ratio=3).  相似文献   

19.
A sensitive method has been developed for the determination of the vasoactive compounds cinnarizine and flunarizine in plasma, urine and milk samples from man and animals. The procedure involves the extraction of the drugs and their internal standard from the biological samples at alkaline pH, back-extraction into sulphuric acid and re-extraction into the organic phase (heptane—isoamyl alcohol).The analyses were carried out by gas chromatography using a nitrogen-selective thermionic specific detector. The detection limit was 0.5 ng/ml of biological fluid and extraction recoveries were sufficiently high (87–94%).The method was applied to plasma samples from bioavailability studies of both cinnarizine and flunarizine in healthy volunteers, and to plasma, urine and milk samples from flunarizine-treated dogs.  相似文献   

20.
The combination of two sensitive, selective and reproducible reversed phase liquid chromatographic (RP-HPLC) methods was developed for the determination of artesunate (AS), its active metabolite dihydroartemisinin (DHA) and mefloquine (MQ) in human plasma. Solid phase extraction (SPE) of the plasma samples was carried out on Supelclean LC-18 extraction cartridges. Chromatographic separation of AS, DHA and the internal standard, artemisinin (QHS) was obtained on a Hypersil C4 column with mobile phase consisting of acetonitrile-0.05 M acetic acid adjusted to pH 5.2 with 1.0M NaOH (42:58, v/v) at the flow rate of 1.50 ml/min. The analytes were detected using an electrochemical detector operating in the reductive mode. Chromatography of MQ and the internal standard, chlorpromazine hydrochloride (CPM) was carried out on an Inertsil C8-3 column using methanol-acetonitrile-0.05 M potassium dihydrogen phosphate adjusted to pH 3.9 with 0.5% orthophosphoric acid (50:8:42, v/v/v) at a flow rate of 1.00 ml/min with ultraviolet detection at 284 nm. The mean recoveries of AS and DHA over a concentration range of 30-750 ng/0.5 ml plasma and MQ over a concentration of 75-1500 ng/0.5 ml plasma were above 80% and the accuracy ranged from 91.1 to 103.5%. The within-day coefficients of variation were 1.0-1.4% for AS, 0.4-3.4% for DHA and 0.7-1.5% for MQ. The day-to-day coefficients of variation were 1.3-7.6%, 1.8-7.8% and 2.0-3.4%, respectively. Both the lower limit of quantifications for AS and DHA were at 10 ng/0.5 ml and the lower limit of quantification for MQ was at 25 ng/0.5 ml. The limit of detections were 4 ng/0.5 ml for AS and DHA and 15 ng/0.5 ml for MQ. The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号