首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Since discovery and first use in the mid-1970s, evanescent wave fluorescence biosensors have developed into a diverse range of instruments, each designed to meet a particular detection need. In this review, we provide a brief synopsis of what evanescent wave fluorescence biosensors are, how they work, and how they are used. In addition, we have summarized the important patents that have impacted the evolution from laboratory curiosities to fully automated commercial products. Finally, we address the critical issues that evanescent wave fluorescence biosensors will face in the coming years.  相似文献   

2.
Meso-tetra(4-carboxyphenyl)porphine (CTPP(4)) binds reversibly to immobilized glucose oxidase (GOD), resulting in an absorbance peak for the CTPP(4)-GOD complex at 427nm. The absorbance intensity of the 427nm peak is reduced upon exposure to glucose, which causes the dissociation of CTPP(4) from GOD. The change in absorbance at 427nm shows linear dependence on glucose concentration from 20 to 200mg/dL (1.1-11.1mM).  相似文献   

3.
Many bacteria produce and secrete proteases during host invasion and pathogenesis. Vibrio harveyi, an opportunistic pathogen of shrimp, is known to use a two-component quorum sensing (QS) mechanism for coordination of gene expression including protease secretion at high population densities. We examined the role of V. harveyi's QS signaling molecules, N-(3-hydroxybutanoyl)-l-homoserine lactone (AI-1) and the boron derivative of autoinducer-2 (BAI-2) in extracellular protease production. A fusion protein, M3CLPY (Rajamani et al., 2007), consisting of a large protease sensitive BAI-2 mutant receptor LuxP (~ 38 kDa) flanked by two protease insensitive cyan and yellow variants of GFP (~ 28 kDa each) was utilized as a substrate to detect secreted protease activity. The M3CLPY fusion, with the addition of wild-type V. harveyi (BB120) cell-free culture filtrate showed a time-dependent loss in fluorescence resonance energy transfer (FRET) associated with the cleavage of the LuxP linker protein and hence separation of the two flurophores. This cleavage of LuxP linker protein leading to decreased FRET efficiency was further confirmed by immunoblotting using anti-GFP antibody. The addition of cell-free filtrates from strains defective in one or both of the two-component QS pathways: luxN (defective in AI-1), luxS (defective in BAI-2), and luxN/luxS (defective in both AI-1/BAI-2) showed differential levels of protease production. The observed protease activities were most pronounced in wild-type, followed by the AI-1 defective mutant (BB170) and the least for luxS mutant (MM30) and luxN/luxS double mutant (MM32) strains. Incidentally, the lowest protease producing strains MM30 and MM32 were both defective in BAI-2 production. This observation was validated by addition of synthetic BAI-2 to MM30 and MM32 strains to restore protease production. Our results indicate that BAI-2 signaling in the two-component QS pathway plays the key role in regulating extracellular protease production in V. harveyi.  相似文献   

4.
Summary The electrophoretic and immunological techniques typically used to detect potentially useful biopharmaceutical proteins are sensitive with detection limits in the nanogram range. However, quantitation of a recombinant protein can be cumbersome and involve large numbers of samples throughout process optimization schemes. Although electrophoretic methods (i.e., SDS-PAGE and Western blots) now avail themselves to quantitation by densitometry, these techniques are time consuming because of the lack of appropriate automated systems. Biological activity assays, when available, often require relatively pure material and are not suitable for analyzing and quantitating impure or semi-purified samples, typical of the fermentation milieu. The optimization of several rDNA-derived protein systems from both prokaryotic and eukaryotic hosts has been completed using PCFIA, a rapid, sensitive system with high throughput. The development of Particle Concentration Fluorescence Immunoassay (CFIA) procedures for several of these rDNA-derived proteins of interest as potential biopharmaceuticals (e.g., -1-antitrypsin, tPA, soluble CD4, and a malaria vaccine candidate) are discussed.  相似文献   

5.
Previous studies have measured the distance between cells and the substratum at sites of adhesion via the emission of a fluorescent dye and waveguide methods. Here, we demonstrate a novel approach to measure the position of fluorescent dyes above a waveguide surface in the 10–200 nm distance range throughout an entire area, yielding a 2D dye distance map or a 3D contour plot. The dye is located in a multilayered Langmuir Blodgett (LB) film or in the plasma membrane of a cell. Waveguide evanescent field fluorescence (WEFF) images obtained using two different waveguide modes are employed allowing, with a simple mathematical approach, the calculation of dye distance maps. Ultra‐thin steps made using LB technology, adhesion distances and the bending of the plasma membrane between focal adhesions of osteoblastic cells are shown as examples. The errors are discussed.

False color representation of a dye distance map with four osteoblasts. The inset represents an overexposed WEFF image of the same field of view.  相似文献   


6.
The use of total internal reflection illumination in fluorescence microscopy (TIRFM) is reviewed with emphasis on application to fluorescent macromolecules that specifically and reversibly bind to planar model membranes supported on glass or quartz substrates. Several methods for characterizing macromolecular motion and organization are discussed: the measurement of equilibrium binding curves to obtain values for equilibrium binding constants; the measurement of fluorescence photobleaching recovery curves to obtain values of kinetic rate constants and surface diffusion coefficients; and the measurement of fluorescence intensities as a function of the evanescent field polarization to characterize orientational order. Applications to cell-substrate contact regions are summarized and future directions of TIRFM are outlined. Correspondence to: N. L. Thompson  相似文献   

7.
A capillary-based optical biosensor has been developed to detect calpastatin, an indicator of meat tenderness. Longissimus muscle samples (n = 11) were extracted from beef carcasses at 0 and 48 h post-mortem. These samples were assayed for calpastatin by traditional laboratory methods and with a newly developed capillary tube biosensor as well as for Warner–Bratzler shear force (WBSF) and crude protein and the responses were compared. Additionally, the response from the capillary-based biosensor was compared to a previously developed optical fiber biosensor. When the 0 and 48 h sampling periods were combined, the capillary tube biosensor was moderately accurate in predicting calpastatin activity (R2 = 0.6058). There was less variation in the 0 h capillary tube biosensor compared to the 0 h pre-column (P = 0.006) and post-column optical fiber biosensors (P = 0.047), therefore the capillary tube biosensor is a more precise system of measurement. This research further advances the development of a calpastatin biosensor and makes online assessment one step closer to reality.  相似文献   

8.
Nanotechnology is a powerful tool for use in diagnostic applications. For these purposes a variety of functional nanoparticles containing fluorescent labels, gold and quantum dots at their cores have been produced, with the aim of enhanced sensitivity and multiplexing capabilities. This work will review progress in the application of polymeric nanoparticles in optical diagnostics, both for in vitro and in vivo detection, together with a discussion of their biodistribution and biocompatibility.  相似文献   

9.
Siderophores are bio‐organic ligands secreted by microbes to chelate and assimilate iron to meet their metabolic requirements. Siderophores and their analogs have tremendous therapeutic and analytical potential including the use as Fe (III) biosensors; however, only few practical applications have been realized. The aim of this study was the optical and biophysical characterization of the siderophore azotobactin (Az) secreted by the nitrogen‐fixing bacteria Azotobacter vinelandii. The peptide exhibited fluorescence in the visible range. Quantum yield and lifetime in excited state were measured to ascertain the sensitivity of the molecule as a fluorescent marker in biochemical assays. Its high affinity toward iron in the ferric state was demonstrated through fluorescence emission quenching studies. The accuracy of azotobactin as biosensing tool was determined by analyzing the levels of iron in biological fluids, particularly in human serum. Furthermore, it was demonstrated that it can be encapsulated in sol–gel matrices without significant loss of its fluorescence signal, thus enabling it suitable for adaptation to optical biosensor for Fe (III).  相似文献   

10.
A fluorescence sandwich immunoassay using high-affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum neurotoxin serotype A (BoNT/A) using a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. Detection to 31 pM with a total incubation time of 3 h was demonstrated. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the reactions were carried out in microcentrifuge tubes with an incubation time of 1 h. The beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell equipped with a fiber optic system for fluorescence measurements. In PBS buffer, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.  相似文献   

11.
In this article, we present the design principles and application of a motif composed of a stem-loop probe (SP) hybridized to a fluorescently labeled universal reporter (UR) for sensing unlabeled nucleic acids. At room temperature, SP-UR is in the hairpin-closed form in which the fluorophore of UR is in proximity to the G bases of the hairpin, where consequently the fluorescent emission is quenched significantly. On hybridization with target, SP-UR is trapped in the hairpin-opened configuration in which the fluorophore and the G quenchers are apart. This turns off quenching, increases emission intensity, and signals the presence of target. Compared with the common approach that employs an oligonucleotide probe with a covalently linked fluorophore, the use of a fluorescently labeled universal reporter strand hybridized to an unlabeled stem-loop probe provides a more efficient approach to the fabrication of nucleic acid sensors and microarrays potentially useful for real-time analysis.  相似文献   

12.
Herein we report on a proof of principle for the reproducible quantification of Vascular Endothelial Growth Factor (VEGF) in human plasma by fluorescence sandwich immunoassays using disposable polydimethylsiloxane (PDMS) microfluidic chips. The system requires 100 times less sample than typical clinical blood tests, while its current quantification limit is established at 4 pM. The in-built calibration method of spiking the plasma with known concentrations of commercially available antigen avoids common sources of error and improves the reliability of the test results. The demonstrated technique is important for immunoassay applications in fundamental scientific research and “point-of-care” (POC) biomedical diagnostics. In particular, the system is immediately applicable to microfluidic quantification of VEGF in human plasma in cancer studies.  相似文献   

13.
DNA amplification using Polymerase Chain Reaction (PCR) in a small volume is used in Lab-on-a-chip systems involving DNA manipulation. For few microliters of volume of liquid, it becomes difficult to measure and monitor the thermal profile accurately and reproducibly, which is an essential requirement for successful amplification. Conventional temperature sensors are either not biocompatible or too large and hence positioned away from the liquid leading to calibration errors. In this work we present a fluorescence based detection technique that is completely biocompatible and measures directly the liquid temperature. PCR is demonstrated in a 3 muL silicon-glass microfabricated device using non-contact induction heating whose temperature is controlled using fluorescence feedback from SYBR green I dye molecules intercalated within sensor DNA. The performance is compared with temperature feedback using a thermocouple sensor. Melting curve followed by gel electrophoresis is used to confirm product specificity after the PCR cycles.  相似文献   

14.
A novel glucose-sensing molecule was created based on galactose/glucose-binding protein (GGBP). GGBP mutants at Asp14, a residue interacting with the 4th hydroxyl group of the sugar molecule, were constructed by mutagenesis to improve the ligand specificity of GGBP. The autofluorescence-based analysis of the binding abilities of these engineered GGBPs showed that the GGBP mutants Asp14Asn and Asp14Glu bound only to glucose in a concentration-dependent manner, without being affected by the presence of galactose. The Phe16Ala mutation, which leads to an increase in the K (d) value toward glucose, was then introduced into these two glucose-specific mutant GGBPs. One of the constructed GGBP double-mutants, Asp14Glu/Phe16Ala, had a glucose specificity with a K(d) value of 3.9 mM, which makes it suitable for use in the measurement of the physiological glucose concentration. Our results demonstrate that it is possible to construct a GGBP which specifically recognizes glucose and has a higher K(d) value and use it as a molecular recognition element of blood glucose monitoring systems by combining two different mutations based on the 3D structure of GGBP.  相似文献   

15.
Detection and quantitation of biomolecules is one of the most commonly performed measurements in biomedical research and clinical diagnostics. There is high demand for convenient, rapid and sensitive biomolecule detection methodologies. In this review we discuss a family of sensors that have been developed in our laboratory that share a common simple biophysical mechanism of action and that are capable of rapid detection of a diverse range of biological targets. The sensors generate fluorescence signal in the presence of the target molecule through target-induced association of short fluorochrome-labeled complementary oligonucleotides that are attached to target recognition elements of the sensors (antibodies, aptamers, etc.) via nanometer scale flexible linkers. This sensor design can be used for detecting proteins, antibodies, nucleic acids and whole cells. The assays using these sensors require only adding a sample to the sensor mix followed by simple fluorescence intensity readout. The simplicity, the speed of detection and the potential for miniaturization are the main assets of these sensors.  相似文献   

16.
In this study, we investigated measurements of the intrinsic fluorescence of yeast hexokinase as an assay for glucose and immobilization of the enzyme in a silica sol-gel matrix as a potential in vivo glucose sensor for use in patients with diabetes. The intrinsic fluorescence of hexokinase in solution (excitation=295 nm, emission=330 nm) decreased by 23% at a saturating glucose concentration of 1 mM (Kd=0.3 mM), but serum abolished the glucose-related fluorescence response. When entrapped in tetramethylorthosilicate-derived sol gel, hexokinase retained activity, with a 25% maximal glucose-related decrease in intrinsic fluorescence, and the saturation point was increased to 50 mM glucose (Kd=12.5 mM). The glucose response range was increased further (to 120 mM, Kd=57 mM) by a covering membrane of poly(2-hydroxyethyl) methacrylate. Unlike free enzyme, the fluorescence responses to glucose with sol-gel immobilized hexokinase, with or without covering membrane, were similar for buffer and serum. We conclude that fluorescence monitoring of sol-gel entrapped yeast hexokinase is a suitable system for development as an in vivo glucose biosensor.  相似文献   

17.
The sodium/iodide symporter (NIS) is primarily responsible for iodide accumulation in the thyroid gland for the synthesis of thyroid hormones; however, it can also transport other lyotropic anions in the thyroid gland and nonthyroid tissues. Some NIS substrates have important physiological or clinical roles, and others are environmental contaminants with health-related consequences. The aim of this study was to assess the utility of a yellow fluorescent protein variant, YFP–H148Q/I152L, as a biosensor to monitor the cellular uptake of NIS substrates, including thiocyanate (SCN), nitrate (), chlorate (), perchlorate (), and perrhenate (). The fluorescence of purified YFP–H148Q/I152L was suppressed by anions with an order of potency of > = I = SCN = > ? Cl. Anions also suppressed the fluorescence of YFP–H148Q/I152L expressed in FRTL-5, a thyroid cell line with high NIS expression. Quantitation of intracellular concentrations revealed differences among anions in the affinity and maximal velocity of NIS-mediated uptake as well as in the rate constant for passive efflux. These results suggest that YFP–H148Q/I152L can serve as an intracellular biosensor of NIS-transported anions and may be useful to study the physiology of endogenous anions as well as the health-related consequences of environmental anions.  相似文献   

18.
The bisubstrate fluorescent probe ARC-583 (Adc-Ahx-(d-Arg)6-d-Lys(5-TAMRA)-NH2) and its application for the characterization of both ATP- and protein/peptide substrate-competitive inhibitors of protein kinases PKA (cyclic AMP-dependent protein kinase) and ROCK (rho kinase) in fluorescence polarization-based assay are described. High affinity of the probe (KD = 0.48 nM toward PKA) enables its application for the characterization of inhibitors with nanomolar and micromolar potency and determination of the active concentration of the kinase in individual experiments as well as in the high-throughput screening format. The probe can be used for the assessment of protein-protein interactions (e.g., between regulatory and catalytic subunits of PKA) and as a cyclic AMP biosensor.  相似文献   

19.
In this study, we continuously monitored, second-by-second, concentration changes of two different carbohydrates (maltose and panose) by using monoclonal antibodies in an optical immunosensor based on total internal reflection fluorescence. Earlier studies have demonstrated that these antibodies increase their intrinsic tryptophan fluorescence upon binding of carbohydrate antigens. Using the four immobilized monoclonal antibodies with low affinities (K(d)>10(-6)M), fast kinetics (k(off)>1s(-1)), and high reversibility gave opportunities for developing a continuous immunosensor without any need for regeneration. Since intrinsic fluorescence was used, no extrinsic labeling was necessary. Sensitivity was in the range of 1-5 microM for panose, and 10-15 microM for maltose and the loss of intensity was as low as 3.5% per hour during measurements. Calculations of DeltaH degrees and DeltaS degrees from the temperature dependence of K(d) indicated an enthalpic driven antigen-antibody binding event that is diminished upon antibody immobilization. We feel certain that weakly interacting antibodies can be used in future applications for continuous monitoring where there is a need to achieve instantaneous information on the concentration of an analyte.  相似文献   

20.
In this paper, the conceptual basis and experimental design of total internal reflection with fluorescence correlation spectroscopy (TIR-FCS) is described. The few applications to date of TIR-FCS to supported membranes are discussed, in addition to a variety of applications not directly involving supported membranes. Methods related, but not technically equivalent, to TIR-FCS are also summarized. Future directions for TIR-FCS are outlined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号