1.
Microarrays are a powerful tool for comparison and understanding of gene expression levels in healthy and diseased states. The method relies upon the assumption that signals from microarray features are a reflection of relative gene expression levels of the cell types under investigation. It has previously been reported that the classical fluorescent dyes used for microarray technology, Cy3 and Cy5, are not ideal due to the decreased stability and fluorescence intensity of the Cy5 dye relative to the Cy3, such that dye bias is an accepted phenomena necessitating dye swap experimental protocols and analysis of differential dye affects. The incentive to find new fluorophores is based on alleviating the problem of dye bias through synonymous performance between counterpart dyes. Alexa Fluor 555 and Alexa Fluor 647 are increasingly promoted as replacements for CyDye in microarray experiments. Performance relates to the molecular and steric similarities, which will vary for each new pair of dyes as well as the spectral integrity for the specific application required. Comparative analysis of the performance of these two competitive dye pairs in practical microarray applications is warranted towards this end. The findings of our study showed that both dye pairs were comparable but that conventional CyDye resulted in significantly higher signal intensities (P < 0.05) and signal minus background levels (P < 0.05) with no significant difference in background values (P > 0.05). This translated to greater levels of differential gene expression with CyDye than with the Alexa Fluor counterparts. However, CyDye fluorophores and in particular Cy5, were found to be less photostable over time and following repeated scans in microarray experiments. These results suggest that precautions against potential dye affects will continue to be necessary and that no one dye pair negates this need.  相似文献   

2.
Evaluation of the gene-specific dye bias in cDNA microarray experiments   总被引:2,自引:0,他引:2  
MOTIVATION: In cDNA microarray experiments all samples are labeled with either Cy3 or Cy5. Systematic and gene-specific dye bias effects have been observed in dual-color experiments. In contrast to systematic effects which can be corrected by a normalization method, the gene-specific dye bias is not completely suppressed and may alter the conclusions about the differentially expressed genes. METHODS: The gene-specific dye bias is taken into account using an analysis of variance model. We propose an index, named label bias index, to measure the gene-specific dye bias. It requires at least two self-self hybridization cDNA microarrays. RESULTS: After lowess normalization we have found that the gene-specific dye bias is the major source of experimental variability between replicates. The ratio (R/G) may exceed 2. As a consequence false positive genes may be found in direct comparison without dye-swap. The stability of this artifact and its consequences on gene variance and on direct or indirect comparisons are addressed. AVAILABILITY: http://www.inapg.inra.fr/ens_rech/mathinfo/recherche/mathematique  相似文献   

3.
DNA microarray analyses commonly use two spectrally distinct fluorescent labels to simultaneously compare different mRNA pools. Signal correlation bias currently limits accepted resolution to twofold changes in gene expression. This bias was investigated by (i) examining fluorescence and absorption spectra and changes in relative fluorescence of DNAs labeled with the Cy3, Cy5, Alexa Fluor 555, and Alexa Fluor 647 dyes and by (ii) using homotypic hybridization assays to compare the Cy dye pair with the Alexa Fluor dye pair. Cy3 or Cy5 dye-labeled DNA exhibited reduced fluorescence and absorption anomalies that were eliminated by nuclease treatment, consistent with fluorescence quenching that arises from dye-dye or dye-DNA-dye interactions. Alexa Fluor 555 and Alexa Fluor 647 dye-labeled DNA exhibited little or no such anomalies. In microarray hybridization, the Alexa Fluor dye pair provided higher signal correlation coefficients (R2) than did the Cy dye pair; at the 95% prediction level, a 1.3-fold change in gene expression was significant using the Alexa Fluor dye pair. Lowered signal correlation of the Cy dye pair was associated with high variance in Cy5 dye signals. These results indicate that fluorescence quenching may be a source of signal bias associated with the Cy dye pair.  相似文献   

4.
5.
Statistical design of reverse dye microarrays   总被引:7,自引:0,他引:7  
MOTIVATION: In cDNA microarray experiments all samples are labelled with either Cy3 dye or Cy5 dye. Certain genes exhibit dye bias-a tendency to bind more efficiently to one of the dyes. The common reference design avoids the problem of dye bias by running all arrays 'forward', so that the samples being compared are always labelled with the same dye. But comparison of samples labelled with different dyes is sometimes of interest. In these situations, it is necessary to run some arrays 'reverse'-with the dye labelling reversed-in order to correct for the dye bias. The design of these experiments will impact one's ability to identify genes that are differentially expressed in different tissues or conditions. We address the design issue of how many specimens are needed, how many forward and reverse labelled arrays to perform, and how to optimally assign Cy3 and Cy5 labels to the specimens. RESULTS: We consider three types of experiments for which some reverse labelling is needed: paired samples, samples from two predefined groups, and reference design data when comparison with the reference is of interest. We present simple probability models for the data, derive optimal estimators for relative gene expression, and compare the efficiency of the estimators for a range of designs. In each case, we present the optimal design and sample size formulas. We show that reverse labelling of individual arrays is generally not required.  相似文献   

6.
7.

Background  

Environmental ozone can rapidly degrade cyanine 5 (Cy5), a fluorescent dye commonly used in microarray gene expression studies. Cyanine 3 (Cy3) is much less affected by atmospheric ozone. Degradation of the Cy5 signal relative to the Cy3 signal in 2-color microarrays will adversely reduce the Cy5/Cy3 ratio resulting in unreliable microarray data.  相似文献   

8.
MOTIVATION: In two-color microarray experiments, well-known differences exist in the labeling and hybridization efficiency of Cy3 and Cy5 dyes. Previous reports have revealed that these differences can vary on a gene-by-gene basis, an effect termed gene-specific dye bias. If uncorrected, this bias can influence the determination of differentially expressed genes. RESULTS: We show that the magnitude of the bias scales multiplicatively with signal intensity and is dependent on which nucleotide has been conjugated to the fluorescent dye. A method is proposed to account for gene-specific dye bias within a maximum-likelihood error modeling framework. Using two different labeling schemes, we show that correcting for gene-specific dye bias results in the superior identification of differentially expressed genes within this framework. Improvement is also possible in related ANOVA approaches. AVAILABILITY: A software implementation of this procedure is freely available at http://cellcircuits.org/VERA  相似文献   

9.
Microarray scanner calibration curves: characteristics and implications   总被引:1,自引:0,他引:1  

Background

Microarray-based measurement of mRNA abundance assumes a linear relationship between the fluorescence intensity and the dye concentration. In reality, however, the calibration curve can be nonlinear.

Results

By scanning a microarray scanner calibration slide containing known concentrations of fluorescent dyes under 18 PMT gains, we were able to evaluate the differences in calibration characteristics of Cy5 and Cy3. First, the calibration curve for the same dye under the same PMT gain is nonlinear at both the high and low intensity ends. Second, the degree of nonlinearity of the calibration curve depends on the PMT gain. Third, the two PMTs (for Cy5 and Cy3) behave differently even under the same gain. Fourth, the background intensity for the Cy3 channel is higher than that for the Cy5 channel. The impact of such characteristics on the accuracy and reproducibility of measured mRNA abundance and the calculated ratios was demonstrated. Combined with simulation results, we provided explanations to the existence of ratio underestimation, intensity-dependence of ratio bias, and anti-correlation of ratios in dye-swap replicates. We further demonstrated that although Lowess normalization effectively eliminates the intensity-dependence of ratio bias, the systematic deviation from true ratios largely remained. A method of calculating ratios based on concentrations estimated from the calibration curves was proposed for correcting ratio bias.

Conclusion

It is preferable to scan microarray slides at fixed, optimal gain settings under which the linearity between concentration and intensity is maximized. Although normalization methods improve reproducibility of microarray measurements, they appear less effective in improving accuracy.
  相似文献   

10.
cDNA microarray spot variability arises from many sources, and different systems have varying requirements for achieving the desired level of precision. We determined relative contributions to variance and investigated sequence discrimination using a multiple-array experimental design, with arrays subdivided to determine position and pin effect. Related fragments of 67 resistance gene homologs (RGHs) isolated from Theobroma cacao L. and grouped by sequence similarity were spotted onto arrays, using two of the same RGHs in the fluorescent dye channels (Cy3, Cy5) of the hybridization solution in a "dye-flip" design. A comprehensive statistical model accounted for variability well, giving a coefficient of variation (CV) based on experimental error of 2.12%. Although we were able to separate 85% of RGH group means clearly, some groups more similar to the target were indistinguishable due to nonspecific hybridization. Genetic factors together contributed 72.2% of the total variation, while position and pin effects and their interactions contributed 9.8%. Replication effect was statistically significant. Otherwise, no tests for position effects were significant. The results of the analysis indicate that our Genetic Microsystems 417 arrayer and Affymetrix 428 scanner are performing with sufficient precision, and we produced useful information for planning efficient future experiments.  相似文献   

11.
12.
Dye-specific bias effects, commonly observed in the two-color microarray platform, are normally corrected using the dye swap design. This design, however, is relatively expensive and labor-intensive. We propose a self-self hybridization design as an alternative to the dye swap design. In this design, the treated and control samples are labeled with Cy5 and Cy3 (or Cy3 and Cy5), respectively, without dye swap, along with a set of self-self hybridizations on the control sample. We compare this design with the dye swap design through investigation of mouse primary hepatocytes treated with three peroxisome proliferator-activated receptor-alpha (PPARalpha) agonists at three dose levels. Using Agilent's Whole Mouse Genome microarray, differentially expressed genes (DEG) were determined for both the self-self hybridization and dye swap designs. The DEG concordance between the two designs was over 80% across each dose treatment and chemical. Furthermore, 90% of DEG-associated biological pathways were in common between the designs, indicating that biological interpretations would be consistent. The reduced labor and expense for the self-self hybridization design make it an efficient substitute for the dye swap design. For example, in larger toxicogenomic studies, only about half the chips are required for the self-self hybridization design compared to that needed in the dye swap design.  相似文献   

13.
Amine-reactive N-hydroxysuccinimidyl esters of Alexa Fluor fluorescent dyes with principal absorption maxima at about 555 nm, 633 nm, 647 nm, 660 nm, 680 nm, 700 nm, and 750 nm were conjugated to antibodies and other selected proteins. These conjugates were compared with spectrally similar protein conjugates of the Cy3, Cy5, Cy5.5, Cy7, DY-630, DY-635, DY-680, and Atto 565 dyes. As N-hydroxysuccinimidyl ester dyes, the Alexa Fluor 555 dye was similar to the Cy3 dye, and the Alexa Fluor 647 dye was similar to the Cy5 dye with respect to absorption maxima, emission maxima, Stokes shifts, and extinction coefficients. However, both Alexa Fluor dyes were significantly more resistant to photobleaching than were their Cy dye counterparts. Absorption spectra of protein conjugates prepared from these dyes showed prominent blue-shifted shoulder peaks for conjugates of the Cy dyes but only minor shoulder peaks for conjugates of the Alexa Fluor dyes. The anomalous peaks, previously observed for protein conjugates of the Cy5 dye, are presumably due to the formation of dye aggregates. Absorption of light by the dye aggregates does not result in fluorescence, thereby diminishing the fluorescence of the conjugates. The Alexa Fluor 555 and the Alexa Fluor 647 dyes in protein conjugates exhibited significantly less of this self-quenching, and therefore the protein conjugates of Alexa Fluor dyes were significantly more fluorescent than those of the Cy dyes, especially at high degrees of labeling. The results from our flow cytometry, immunocytochemistry, and immunohistochemistry experiments demonstrate that protein-conjugated, long-wavelength Alexa Fluor dyes have advantages compared to the Cy dyes and other long-wavelength dyes in typical fluorescence-based cell labeling applications.  相似文献   

14.
Krogh M  Liu Y  Waldemarson S  Valastro B  James P 《Proteomics》2007,7(23):4235-4244
Differential in-gel electrophoresis (DIGE) experiments allow three protein samples to be run per gel. The three samples are labeled with the spectrally resolvable fluorescent dyes, Cy2, Cy3, and Cy5, respectively. Here, we show that protein-specific dye effects exist, and we present a linear mixed model for analysis of DIGE data which takes dye effects into account. A Java implementation of the model, called DIGEanalyzer, is freely available at http://bioinfo.thep.lu.se/digeanalyzer.html. Three DIGE experiments from our laboratory, with 173, 64, and 24 gels, respectively, were used to quantify and verify the dye effects. DeCyder 5.0 and 6.5 were used for spot detection and matching. The fractions of proteins with a statistically significant (0.001 level) dye effect were 19, 34, and 23%, respectively. The fractions of proteins with a dye effect above 1.4-fold change were 1, 4, and 6%, respectively. The median magnitude of the dye effect was 1.07-fold change for Cy5 versus Cy3 and 1.16-fold change for Cy3 versus Cy2. The maximal dye effect was a seven-fold change. The dye effects of spots corresponding to the same protein tend to be similar within each of the three experiments, and to a smaller degree across experiments.  相似文献   

15.
High-density arrays of DNA bound to solid substrates offer a powerful approach to identifying changes in gene expression in response to toxicants. While DNA arrays have been used to explore qualitative changes in gene regulation, less attention has focused on the quantitative aspects of this technology. Arrays containing expressed sequence tags for xenobiotic metabolizing enzymes, proteins associated with glutathione regulation, DNA repair enzymes, heat shock proteins, and housekeeping genes were used to examine gene expression in response to beta-naphthoflavone (beta-NF). Upregulation of cytochrome P4501a1 (Cyp1a1) and 1a2 in mouse liver was maximal 8 h after beta-NF administration. Significant upregulation of Cyp1a2 was noted at beta-NF doses as low as 0.62 and 1.2 mg/kg when gene expression was measured by microarray or Northern blotting, respectively. Maximal Cyp1a2 induction is 5-fold by Northern analysis and 10-fold by microarray. Induction of Cyp1a1 was 15- and 20-fold by Northern and microarray analysis, respectively. The coefficient of variation for spot to spot and slide to slide comparisons was <15%; this variability was smaller than interanimal variability (18-60%). Comparison of mRNA expression in control animals indicated that there are differences in labeling/detection associated with Cy3/Cy5 dyes; accordingly, experiments must include methods for establishing baseline signals for all genes. We conclude that the dynamic range and sensitivity of DNA microarrays on glass slides is comparable to Northern blotting analysis and that variability of the data introduced during spotting and hybridization is less than the interanimal variability.  相似文献   

16.
Agbavwe C  Somoza MM 《PloS one》2011,6(7):e22177
Cy3 and Cy5 are among the most commonly used oligonucleotide labeling molecules. Studies of nucleic acid structure and dynamics use these dyes, and they are ubiquitous in microarray experiments. They are sensitive to their environment and have higher quantum yield when bound to DNA. The fluorescent intensity of terminal cyanine dyes is also known to be significantly dependent on the base sequence of the oligonucleotide. We have developed a very precise and high-throughput method to evaluate the sequence dependence of oligonucleotide labeling dyes using microarrays and have applied the method to Cy3 and Cy5. We used light-directed in-situ synthesis of terminally-labeled microarrays to determine the fluorescence intensity of each dye on all 1024 possible 5'-labeled 5-mers. Their intensity is sensitive to all five bases. Their fluorescence is higher with 5' guanines, and adenines in subsequent positions. Cytosine suppresses fluorescence. Intensity falls by half over the range of all 5-mers for Cy3, and two-thirds for Cy5. Labeling with 5'-biotin-streptavidin-Cy3/-Cy5 gives a completely different sequence dependence and greatly reduces fluorescence compared with direct terminal labeling.  相似文献   

17.

Background  

The antibody microarray technique is a newly emerging proteomics tool for differential protein expression analyses that uses fluorescent dyes Cy 3 and Cy 5. Environmental factors, such as light exposure, can affect the signal intensity of fluorescent dyes on microarray slides thus, it is logical to scan microarray slides immediately after the final wash and drying processes. However, no research data are available concerning time-dependent changes of fluorescent signals on antibody microarray slides to this date. In the present study, microarray slides were preserved at -20°C after regular microarray experiments and were rescanned at day 10, 20 and 30 to evaluate change in signal intensity.  相似文献   

18.
一种标记cDNA芯片探针的新方法   总被引:3,自引:0,他引:3  
探讨mRNA长片段反转录PCR技术(RT-LDPCR)在cDNA芯片微量探针标记和信号放大中的应用.首先提取BEP2D细胞的总RNA,然后用两种不同的方法进行标记,一种为RT-LDPCR,用荧光素Cy3-dCTP进行标记;另一种为传统的RNA反转录,用荧光素Cy5-dCTP进行标记.将两种方法标记好的探针等量混合后与含有440个点(44个基因)的cDNA芯片同时杂交,发现二者具有很高的一致性(0.5<Cy3/Cy5>2.0).由于RNA反转录法为cDNA芯片探针标记的传统方法,从而验证了RT-LDPCR用于cDNA芯片探针标记的可行性.RT-LDPCR具有对样品总RNA的需要量少和可对样品中信号进行放大的优点,特别适合于对材料来源受到限制的RNA进行标记.  相似文献   

19.
Workman C  Jensen LJ  Jarmer H  Berka R  Gautier L  Nielser HB  Saxild HH  Nielsen C  Brunak S  Knudsen S 《Genome biology》2002,3(9):research0048.1-research004816

Background  

Microarray data are subject to multiple sources of variation, of which biological sources are of interest whereas most others are only confounding. Recent work has identified systematic sources of variation that are intensity-dependent and non-linear in nature. Systematic sources of variation are not limited to the differing properties of the cyanine dyes Cy5 and Cy3 as observed in cDNA arrays, but are the general case for both oligonucleotide microarray (Affymetrix GeneChips) and cDNA microarray data. Current normalization techniques are most often linear and therefore not capable of fully correcting for these effects.  相似文献   

20.
Previous studies have shown that a functionalized viral nanoparticle can be used as a fluorescent signal-generating element and enhance detection sensitivity for immunoassays and low density microarrays. In this study, we further tested this ability in commercial DNA microarrays, including Affymetrix high density resequencing microarray. Optimum conditions for NeutrAvidin and dye coupling to a double-cysteine mutant of cowpea mosaic virus (CPMV) were found to be comparable to the commonly used streptavidin-phycoerythrin (SAPE) for high density resequencing microarray. A 3-fold signal enhancement in comparison to Cy5-dCTP controls was obtained when using nanoparticles on control scorecard expression microarrays. Hybridization results from commercially available 8000 rat expression arrays indicate an increment of 14% on the detected features when the virus complex was used as the staining reagent in comparison to Cy5-dCTP controls. The current work shows the utility of the CPMV-dye nanoparticles as a detection reagent in well-established detection platforms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏