 共查询到20条相似文献,搜索用时 62 毫秒
1.
Thermophysiological responses of heat production and heat loss were measured in seven adult volunteers (six males and one female, aged 31-74 years) during 45 min dorsal exposures of the whole body to 100 MHz continuous wave (CW) radio frequency (RF) energy. Three power densities (PD) (average PD = 4, 6, and 8 mW/cm(2); whole body specific absorption rate [SAR] = 0.068 [W/kg]/[mW/cm(2)]) were tested in each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C), as well as in T(a) controls (no RF). A standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline) was used. Measured responses included esophageal and seven skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow. No changes in metabolic heat production occurred under any test condition. Unlike published results of similar exposures at 450 and 2450 MHz, local skin temperatures, even those on the back that were irradiated directly, changed little or not at all during 100 MHz exposures. The sole exception was the temperature of the ankle skin, which increased by 3-4 degrees C in some subjects at PD = 8 mW/cm(2). During the 45 min RF exposure, esophageal temperature showed modest changes (range = -0.15 to 0.13 degrees C) and never exceeded 37.2 degrees C. Thermoregulation was principally controlled by appropriate increases in evaporative heat loss (sweating) and, to a lesser extent, by changes in skin blood flow. Because of the deep penetration of RF energy at this frequency, effectively bypassing the skin, these changes must have been stimulated by thermal receptors deep in the body rather than those located in the skin.  相似文献   

2.
A previous study showed a substantial increase in the colonic temperature of rhesus monkeys (Macaca mulatta) exposed to radiofrequency (RF) fields at a frequency near whole-body resonance and specific absorption rates (SAR) of 2-3 W/kg. The present experiments were conducted to determine the metabolic and vasomotor responses during exposures to similar RF fields. We exposed five adult male rhesus monkeys to 225 MHz radiation (E orientation) in an anechoic chamber. Oxygen consumption and carbon dioxide production were measured before, during, and after RF exposure. Colonic, tail and leg skin temperatures were continuously monitored with RF-nonperturbing probes. The monkeys were irradiated at two carefully-controlled ambient temperatures, either cool (20 degrees C) or thermoneutral (26 degrees C). Power densities ranged from 0 (sham) to 10.0 mW/cm2 with an average whole-body SAR of 0.285 (W/kg)/(mW/cm2). We used two experimental protocols, each of which began with a 120-min pre-exposure equilibration period. One protocol involved repetitive 10-min RF exposures at successively higher power densities with a recovery period between exposures. In the second protocol, a 120-min RF exposure permitted the measurement of steady-state thermoregulatory responses. Metabolic and vasomotor adjustments in the rhesus monkey exposed to 225 MHz occurred during brief or sustained exposures at SARs at or above 1.4 W/kg. The SAR required to produce a given response varied with ambient temperature. Metabolic and vasomotor responses were coordinated effectively to produce a stable deep body temperature. The results show that the thermoregulatory response of the rhesus monkey to an RF exposure at a resonant frequency limits storage of heat in the body. However, substantial increases in colonic temperature were not prevented by such responses, even in a cool environment.  相似文献   

3.
Anatomic variability in the deposition of radiofrequency electromagnetic energy in mammals has been well documented. A recent study [D'Andrea et al., 1985] reported specific absorption rate (SAR) hotspots in the brain, rectum and tail of rat carcasses exposed to 360- and to 2,450-MHz microwave radiation. Regions of intense energy absorption are generally thought to be of little consequence when predicting thermal effects of microwave irradiation because it is presumed that heat transfer via the circulatory system promptly redistributes localized heat to equilibrate tissue temperature within the body. Experiments on anesthetized, male Long-Evans rats (200-260 g) irradiated for 10 or 16 min with 2,450, 700, or 360 MHz radiation at SARs of 2 W/kg, 6 W/kg, or 10 W/kg indicated that postirradiation localized temperatures in regions previously shown to exhibit high SARs were appreciably above temperatures at body sites with lower SARs. The postirradiation temperatures in the rectum and tail were significantly higher in rats irradiated at 360 MHz and higher in the tail at 2,450 MHz than temperatures resulting from exposure to 700 MHz. This effect was found for whole-body-averaged SARs as low as 6 W/kg at 360 MHz and 10 W/kg at 2,450 MHz. In contrast, brain temperatures in the anesthetized rats were not different from those measured in the rest of the body following microwave exposure.  相似文献   

4.
Thermoregulatory responses of heat production and heat loss were measured in seven adult volunteers (four women and three men, aged 21–57 yr) during 45-min dorsal exposures of the whole body to 450 MHz continuous wave radio frequency (RF) fields. Two power densities (PD) (local peak PD = 18 and 24 mW/cm2; local peak specific absorption rate = 0.320 [W/kg]/[mW/cm2]) were tested in each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). No changes in metabolic heat production occurred under any exposure conditions. Vigorous increases in sweating rate on back and chest, directly related to both Ta and PD, cooled the skin and ensured efficient regulation of the deep body (esophageal) temperature to within 0.1 °C of the normal level. Category judgments of thermal sensation, comfort, sweating, and thermal preference usually matched the measured changes in physiological responses. Some subtle effects related to gender were noted that confirm classic physiological data. Our results indicate that dorsal exposures of humans to a supra-resonant frequency of 450 MHz at local peak specific absorption rates up to 7.68 W/kg are mildly thermogenic and are counteracted efficiently by normal thermophysiologic heat loss mechanisms, principally sweating. Bioelectromagnetics 19:232–245, 1998. Published 1998 Wiley-Liss, Inc.  相似文献   

5.
Since 1994, our research has demonstrated how thermophysiological responses are mobilized in human volunteers exposed to three radio frequencies, 100, 450, and 2450 MHz. A significant gap in this frequency range is now filled by the present study, conducted at 220 MHz. Thermoregulatory responses of heat loss and heat production were measured in six adult volunteers (five males, one female, aged 24-63 years) during 45 min whole body dorsal exposures to 220 MHz radio frequency (RF) energy. Three power densities (PD = 9, 12, and 15 mW/cm(2) [1 mW/cm(2) = 10 W/m(2)], whole body average normalized specific absorption rate [SAR] = 0.045 [W/kg]/[mW/cm(2)] = 0.0045 [W/kg]/[W/m(2)]) were tested at each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C) plus T(a) controls (no RF). Measured responses included esophageal (T(esoph)) and seven skin temperatures (T(sk)), metabolic rate (M), local sweat rate, and local skin blood flow (SkBF). Derived measures included heart rate (HR), respiration rate, and total evaporative water loss (EWL). Finite difference-time domain (FDTD) modeling of a seated 70 kg human exposed to 220 MHz predicted six localized "hot spots" at which local temperatures were also measured. No changes in M occurred under any test condition, while T(esoph) showed small changes (< or =0.35 degrees C) but never exceeded 37.3 degrees C. As with similar exposures at 100 MHz, local T(sk) changed little and modest increases in SkBF were recorded. At 220 MHz, vigorous sweating occurred at PD = 12 and 15 mW/cm(2), with sweating levels higher than those observed for equivalent PD at 100 MHz. Predicted "hot spots" were confirmed by local temperature measurements. The FDTD model showed the local SAR in deep neural tissues that harbor temperature-sensitive neurons (e.g., brainstem, spinal cord) to be greater at 220 than at 100 MHz. Human exposure at both 220 and 100 MHz results in far less skin heating than occurs during exposure at 450 MHz. However, the exposed subjects thermoregulate efficiently because of increased heat loss responses, particularly sweating. It is clear that these responses are controlled by neural signals from thermosensors deep in the brainstem and spinal cord, rather than those in the skin.  相似文献   

6.
Six male New Zealand white rabbits were individually exposed to 600 MHz radiofrequency (RF) radiation for 90 min in a waveguide exposure system at an ambient temperature (Ta) of 20 or 30 degrees C. Immediately after exposure, the rabbit was removed from the exposure chamber and its colonic and ear skin temperatures were quickly measured. The whole-body specific absorption rate (SAR) required to increase colonic and ear skin temperature was determined. At a Ta of 20 degrees C the threshold SAR for elevating colonic and ear skin temperature was 0.64 and 0.26 W/kg, respectively. At a Ta of 30 degrees C the threshold SARs were slightly less than at 20 degrees C, with values of 0.26 W/kg for elevating colonic temperature and 0.19 W/kg for elevating ear skin temperature. The relationship between heat load and elevation in deep body temperature shown in this study at 600 MHz is similar to past studies which employed much higher frequencies of RF radiation (2450-2884 MHz). On the other hand, comparison of these data with studies on exercise-induced heat production and thermoregulation in the rabbit suggest that the relationship between heat gain and elevation in body temperature in exercise and from exposure to RF radiation may differ considerably. When combined with other studies, it was shown that the logarithm of the SAR required for a 1.0 degree C elevation in deep body temperature of the rabbit, rat, hamster, and mouse was inversely related to the logarithm of body mass. The results of this study are consistent with the conclusion that body mass strongly influences thermoregulatory sensitivity of the aforementioned laboratory mammals during exposure to RF radiation.  相似文献   

7.
The purpose of this study was to assess the ability of the rat to reduce metabolic rate when exposed to deep-penetrating radio-frequency (RF) radiation. Male Sprague-Dawley rats were maintained at an ambient temperature (Ta) of 10 degrees C and exposed to 600-MHz radiation while metabolic rate (MR) was measured by indirect calorimetry. RF radiation exposures were made in a waveguide-type system that permitted the continuous control of specific absorption rate (SAR). SAR's of 2-5 W/kg led to significant reductions in MR when averaged from 30 to 60 min after the initiation of RF radiation exposure. The total decrease in MR during RF radiation exposure accounted for approximately 37% of the total RF heat load. Exposure of another group of rats to the same SAR's at a Ta of 10 degrees C resulted in a significant elevation in colonic temperature. Thus, despite the decrease in MR, heat gain still exceeded heat loss during RF radiation exposure, with a resultant elevation in deep body temperature. In conclusion, in a cold environment the rat exposed to RF radiation decreases its MR. However, the response time and efficiency of the response is not adequate to prevent an increase in body temperature.  相似文献   

8.
Thermoregulatory responses of heat production and heat loss were measured in two different groups of seven adult volunteers (males and females) during 45‐min dorsal exposures of the whole body to 450 or 2450 MHz continuous‐wave radio frequency (RF) fields. At each frequency, two power densities (PD) were tested at each of three ambient temperatures (Ta = 24, 28, and 31 °C) plus Ta controls (no RF). The normalized peak surface specific absorption rate (SAR), measured at the location of the subject's center back, was the same for comparable PD at both frequencies, i.e., peak surface SAR = 6.0 and 7.7 W/kg. No change in metabolic heat production occurred under any exposure conditions at either frequency. The magnitude of increase in those skin temperatures under direct irradiation was directly related to frequency, but local sweating rates on back and chest were related more to Ta and SAR. Both efficient sweating and increased local skin blood flow contributed to the regulation of the deep body (esophageal) temperature to within 0.1 °C of the baseline level. At both frequencies, normalized peak SARs in excess of ANSI/IEEE C95.1 guidelines were easily counteracted by normal thermophysiological mechanisms. The observed frequency‐related response differences agree with classical data concerning the control of heat loss mechanisms in human beings. However, more practical dosimetry than is currently available will be necessary to evaluate realistic human exposures to RF energy in the natural environment. Bioelectromagnetics 20:12–20, 1999. Published 1999 Wiley‐Liss, Inc.  相似文献   

9.
Many reports describe data showing that continuous wave (CW) and pulsed (PW) radiofrequency (RF) fields, at the same frequency and average power density (PD), yield similar response changes in the exposed organism. During whole-body exposure of squirrel monkeys at 2450 MHz CW and PW fields, heat production and heat loss responses were nearly identical. To explore this question in humans, we exposed two different groups of volunteers to 2450 MHz CW (two females, five males) and PW (65 micros pulse width, 10(4) pps; three females, three males) RF fields. We measured thermophysiological responses of heat production and heat loss (esophageal and six skin temperatures, metabolic heat production, local skin blood flow, and local sweat rate) under a standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline), conducted in three ambient temperatures (T(a) = 24, 28, and 31 degrees C). At each T(a), average PDs studied were 0, 27, and 35 mW/cm2 (Specific absorption rate (SAR) = 0, 5.94, and 7.7 W/kg). Mean data for each group showed minimal changes in core temperature and metabolic heat production for all test conditions and no reliable differences between CW and PW exposure. Local skin temperatures showed similar trends for CW and PW exposure that were PD-dependent; only the skin temperature of the upper back (facing the antenna) showed a reliably greater increase (P =.005) during PW exposure than during CW exposure. Local sweat rate and skin blood flow were both T(a)- and PD-dependent and showed greater variability than other measures between CW and PW exposures; this variability was attributable primarily to the characteristics of the two subject groups. With one noted exception, no clear evidence for a differential response to CW and PW fields was found.  相似文献   

10.
The present study was undertaken to investigate the thermal adjustments of squirrel monkeys exposed in a cold environment to relatively high energy levels of microwave fields. The animals (Saimiri sciureus) were equilibrated for 90 min to a cool environment (Ta = 20 degrees C) to elevate metabolic heat production (M). They were then exposed for brief (10-min) or long (30-min) periods to 2,450-MHz continuous-wave microwaves. Power densities (MPD) were 10, 14, 19, and 25 mW/cm2 during brief exposures and 30, 35, 40, and 45 mW/cm2 during long exposures (rate of energy absorption: SAR = 0.15 [W/kg]/[mW/cm2]). Individual exposures were separated by enough time to allow physiological variables to return to baseline levels. The results confirm that each microwave exposure induced a rapid decrease in M. In a 20 degree C environment, the power density of a 10-min exposure required to lower M to approximate the resting level was 35 mW/cm2 (SAR = 5.3 W/kg). During the long exposures, 20 min was needed to decrease M to its lowest level. Cessation of irradiation was associated with persistence of low levels of M for periods that depended on the power density of the preceding microwave exposure. Vasodilation, as indexed by changes in local skin temperature, occurred at a high rate of energy absorption (SAR = 4.5 W/kg) and was sufficient to prevent a dramatic increase in storage of thermal energy by the body; vasoconstriction was reinstated after termination of irradiation. Patterns of thermophysiological responses confirm the influence both of peripheral and of internal inputs to thermoregulation in squirrel monkeys exposed to microwaves in a cool environment.  相似文献   

11.
Mouse spermatozoa were exposed in vitro for 1 h to 27- or 2,450-MHz CW RF radiation at SARs of 0 to 90 W/kg under isothermal (37 +/- 0.2 degrees C) conditions. Exposure at either frequency to RF radiation at SARs of 50 W/kg or greater resulted in a statistically significant reduction in the ability of irradiated sperm to fertilize mouse ova in vitro (P less than .05). Over the range of SARs there was no apparent difference in the effects of 27- vs. 2,450-MHz RF radiation. There were no readily detectable exposure effects on spermatozoan morphology, ultrastructure, or capacitation. The reduction of in vitro fertilization is attributed to a direct effect of RF radiation on spermatozoa rather than to heating.  相似文献   

12.
We examined the histological changes by radiofrequency (RF) fields on rat testis, specifically with respect to sensitive processes such as spermatogenesis. Male rats were exposed to 848.5 MHz RF for 12 weeks. The RF exposure schedule consisted of two 45‐min RF exposure periods, separated by a 15‐min interval. The whole‐body average specific absorption rate (SAR) of RF was 2.0 W/kg. We then investigated correlates of testicular function such as sperm counts in the cauda epididymis, malondialdehyde concentrations in the testes and epididymis, frequency of spermatogenesis stages, germ cell counts, and appearance of apoptotic cells in the testes. We also performed p53, bcl‐2, caspase 3, p21, and PARP immunoblotting of the testes in sham‐ and RF‐exposed animals. Based on these results, we concluded that subchronic exposure to 848.5 MHz with 2.0 W/kg SAR RF did not have any observable adverse effects on rat spermatogenesis. Bioelectromagnetics 31:528–534, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

13.
Permission was received from the Brooks AFB Institutional Review Board and the AF Surgeon General's Office to exceed the peak power density (PD = 35 mW/cm(2)) we had previously studied during partial body exposure of human volunteers at 2450 MHz. Two additional peak PD were tested (50 and 70 mW/cm(2)). The higher of these PD (normalized peak local SAR = 15.4 W/kg) is well outside the IEEE C95.1 guidelines for partial body exposure, as is the estimated whole body SAR approximately 1.0 W/kg. Seven volunteers (four males, three females) were tested at each PD in three ambient temperatures (T(a) = 24, 28, and 31 degrees C) under our standard protocol (30 min baseline, 45 min RF exposure, 10 min baseline). The thermophysiological data (esophageal and six skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow) were combined with comparable data at PD = 0, 27, and 35 mW/cm(2) from our 1999 study to generate response functions across PD. No change in esophageal temperature or metabolic heat production was recorded at any PD in any T(a). At PD = 70 mW/cm(2), skin temperature on the upper back (irradiated directly) increased 4.0 degrees C in T(a) = 24 degrees C, 2.6 degrees C in T(a) = 28 degrees C, and 1.8 degrees C in T(a) = 31 degrees C. These differences were primarily due to the increase in local sweat rate, which was greatest in T(a) = 31 degrees C. Also at PD = 70 mW/cm(2), local skin blood flow on the back increased 65% over baseline levels in T(a) = 31 degrees C, but only 40% in T(a) = 24 degrees C. Although T(a) becomes an important variable when RF exposure exceeds the C95.1 partial body exposure limits, vigorous heat loss responses of blood flow and sweating maintain thermal homeostasis efficiently. It is also clear that strong sensations of heat and thermal discomfort will motivate a timely retreat from a strong RF field, long before these physiological responses are exhausted. Published 2001 Wiley-Liss, Inc.  相似文献   

14.
The evolution of mobile phone technology is toward an increase of the carrier frequency up to 2.45 GHz. Absorption of radiofrequency (RF) radiation becomes more superficial as the frequency increases. This increasingly superficial absorption of RF radiation by the skin, which is the first organ exposed to RF radiation, may lead to stress responses in skin cells. We thus investigated the expression of three heat-shock proteins (HSP70, HSC70, HSP27) using immunohistochemistry and induction of apoptosis by flow cytometry on human primary keratinocytes and fibroblasts. A well-characterized exposure system, SXC 1800, built by the IT'IS foundation was used at 1800 MHz, with a 217 Hz modulation. We tested a 48-h exposure at an SAR of 2 W/kg (ICNIRP local exposure limit). Skin cells were also irradiated with a 600 mJ/cm2 single dose of UVB radiation and subjected to heat shock (45 degrees C, 20 min) as positive controls for apoptosis and HSP expression, respectively. The results showed no effect of a 48-h GSM-1800 exposure at 2 W/kg on either keratinocytes or fibroblasts, in contrast to UVB-radiation or heat-shock treatments, which injured cells. We thus conclude that the GSM-1800 signal does not act as a stress factor on human primary skin cells in vitro.  相似文献   

15.
A recent study raised concern about increase of resting blood pressure after a 35 min exposure to the radiofrequency (RF) field emitted by a 900 MHz cellular phone. In this randomized, double blind, placebo controlled crossover trial, 32 healthy subjects were submitted to 900 MHz (2 W), 1800 MHz (1 W) cellular phone exposure, and to sham exposure in separate sessions. Arterial blood pressure (arm cuff method) and heart rate were measured during and after the 35 min RF and sham exposure sessions. We evaluated cardiovascular responses in terms of blood pressure and heart rate during controlled breathing, spontaneous breathing, head-up tilt table test, Valsalva manoeuvre and deep breathing test. Arterial blood pressure and heart rate did not change significantly during or after the 35 min RF exposures at 900 MHz or 1800 MHz, compared to sham exposure. The results of this study indicate that exposure to a cellular phone, using 900 MHz or 1800 MHz with maximal allowed antenna powers, does not acutely change arterial blood pressure and heart rate.  相似文献   

16.
In utero exposure to microwave radiation and rat brain development   总被引:1,自引:0,他引:1  
Timed-pregnancy rats were exposed in a circular waveguide system starting on day 2 of gestation. The system operated at 2,450 MHz (pulsed waves; 8 microseconds PW; 830 pps). Specific absorption rate (SAR) was maintained at 0.4 W/kg by increasing the input power as the animals grew in size. On day 18 of gestation the dams were removed from the waveguide cages and euthanized; the fetuses were removed and weighed. Fetal brains were excised and weighed, and brain RNA, DNA and protein were determined. Values for measured parameters of the radiated fetuses did not differ significantly from those of sham-exposed fetuses. A regression of brain weight on body weight showed no micrencephalous fetuses in the radiation group when using as a criterion a regression line based on two standard errors of the estimate of the sham-exposed group. In addition, metrics derived from brain DNA (ie, cell number and cell size) showed no significant differences when radiation was compared to sham exposure. We conclude that 2,450-MHz microwave radiation, at an SAR of 0.4 W/kg, did not produce significant alterations in brain organogenesis.  相似文献   

17.
Despite much research, gaps remain in knowledge about the potential health effects of exposure to radiofrequency (RF) fields. This study investigated the effects of early‐life exposure to pulsed long term evolution (LTE) 1,846 MHz downlink signals on innate mouse behavior. Animals were exposed for 30 min/day, 5 days/week at a whole‐body average specific energy absorption rate (SAR) of 0.5 or 1 W/kg from late pregnancy (gestation day 13.5) to weaning (postnatal day 21). A behavioral tracking system measured locomotor, drinking, and feeding behavior in the home cage from 12 to 28 weeks of age. The exposure caused significant effects on both appetitive behaviors and activity of offspring that depended on the SAR. Compared with sham‐exposed controls, exposure at 0.5 W/kg significantly decreased drinking frequency (P ≤ 0.000) and significantly decreased distance moved (P ≤ 0.001). In contrast, exposure at 1 W/kg significantly increased drinking frequency (P ≤ 0.001) and significantly increased moving duration (P ≤ 0.005). In the absence of other plausible explanations, it is concluded that repeated exposure to low‐level RF fields in early life may have a persistent and long‐term effect on adult behavior. Bioelectromagnetics. 2019;40:498–511. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.  相似文献   

18.
This study was designed to identify and measure changes in thermoregulatory responses, both behavioral and physiological, that may occur when squirrel monkeys are exposed to 2450-MHz continuous wave microwaves 40 hr/week for 15 weeks. Power densities of 1 or 5 mW/cm2 (specific absorption rate = 0.16 W/kg per mW/cm2) were presented at controlled environmental temperatures of 25, 30, or 35 degrees C. Standardized tests, conducted periodically, before, during, and after treatment, assessed changes in thermoregulatory responses. Dependent variables that were measured included body mass, certain blood properties, metabolic heat production, sweating, skin temperatures, deep body temperature, and behavioral responses by which the monkeys selected a preferred environmental temperature. Results showed no reliable alteration of metabolic rate, internal body temperature, blood indices, or thermoregulatory behavior by microwave exposure, although the ambient temperature prevailing during chronic exposure could exert an effect. An increase in sweating rate occurred in the 35 degrees C environment, but sweating was not reliably enhanced by microwave exposure. Skin temperature, reflecting vasomotor state, was reliably influenced by both ambient temperature and microwaves. The most robust consequence of microwave exposure was a reduction in body mass, which appeared to be a function of microwave power density.  相似文献   

19.
Two systems for exposing mice to 2,450-MHz electromagnetic fields are described. In a waveguide system, four mice were placed in a Styrofoam cage and exposed dorsally to circularly polarized electromagnetic fields. The temperature and humidity in the mouse holder were kept constant by forced-air ventilation. For 1-W input power to the waveguide, the average specific absorption rate (SAR) was determined by twin-well calorimetry to be 3.60 ± 0.11 (SE) W/kg in 27-g mice. The maximum SAR at the skin surface determined thermographically was 8.36 W/kg in the head of the mouse. The second system was a miniature anechoic chamber. Six mice were irradiated dorsally to far field plane waves. Copper shielding and high-temperature absorbing material were lined inside the chamber to accommodate the high input power. The air ventilation at the location of the mice was separately controlled so that any heating in the absorber would not affect the animals. For 1-W input power, the average SAR was 0.17 ± 0.01 W/kg and the maximum SAR at the skin surface was 0.41 W/kg in the animal when irradiated with body axis parallel to the E field; the SARs were 0.11 ± 0.01 W/kg and 0.64 W/kg, respectively, when irradiated perpendicular to the E field.  相似文献   

20.
To compare the effects of exposure to a near-resonant frequency of microwaves at two orientations with a higher frequency exposure, five rhesus monkeys were exposed for 4 hr to 225 MHz, electric field oriented parallel to the long axis of the body (225 MHz-E), and to 225 MHz, magnetic field orientation (225 MHz-H), or to 1290 MHz, electric field orientation. On a separate occasion, the monkeys were exposed at night to 225 MHz-E. Exposures were conducted with the animal chair restrained in an anechoic chamber with rectal temperature continuously monitored. Blood samples were taken hourly during the 225-MHz-E exposures for cortisol analysis. The power densities used were 0, 1.2, 2.5, 5.0, 7.5, 10.0, and 15.0 mW/cm2 for 225 MHz-E (day), 0 and 5 mW/cm2 (225 MHz-E night and 225 MHz-H), and 0, 20, 28, and 38 mW/cm2 (1290 MHz). The monkeys were unable to tolerate exposure at power densities equal to or greater than 7.5 mW/cm2 (5.1 W/kg) at 225 MHz-E for longer than 90 min. The criterion for tolerance was that the rectal temperature would not exceed 41.5 degrees C. Average rectal temperature increases for day exposure to 225 MHz-E were 0.4 and 1.7 degrees C for 4-hr exposures to 2.5 and 5.0 mW/cm2 (1.7 and 3.4 W/kg). No changes in circulating cortisol levels occurred during any exposures to 5 mW/cm2 or less. Night exposures to 5 mW/cm2 (3.4 W/kg) at 225 MHz-E raised mean rectal temperature 2.1 degrees C. Exposure to 5 mW/cm2 (1.2 W/kg) at 225 MHz-H for 4 hr resulted in a 0.2 degree rise in mean rectal temperature. For 4 hr of 1290-MHz exposure to 20, 28, or 38 mW/cm2 (2.9, 4.0, and 5.4 W/kg), the mean body temperature increases were 0.4, 0.7, and 1.3 degrees C, respectively. The degree of hyperthermia caused by radiofrequency (rf) exposure was shown to be frequency and orientation dependent for equivalent power densities of exposure.  相似文献   