1.
The rapid determination of waste-water quality of waste-water treatment plants in terms of pollutional strength, i.e. biochemical oxygen demand (BOD) is difficult or even impossible using the chemical determination method. The present study reports the determination of BOD within minutes using microbial BOD sensors, as compared to the 5-day determination using the conventional method. Multiple criteria establish the basis for the development of a BOD biosensor useful for rapid and reliable BOD estimation in industrial waste-waters. Of these, preparation of a suitable novel immobilized microbial membrane used in conjunction with an apt transducer is discussed. As a result, a microbial biosensor based on a formulated, synergistic, pre-tested microbial consortium has been developed for the measurement of BOD load of various industrial waste-waters. The sensor showed maximum response in terms of current difference, when a cell concentration of 2.25 x 10(10) CFU, harvested in their log phase of growth were utilized for microbial membrane construction. The sensor showed a stability of 180 days when the prepared membranes were stored at a temperature of 4 degrees C in 50 mM phosphate buffer of pH 6.8. The reusability of the immobilized membranes was up to 200 cycles without appreciable loss of their response characteristics. A linear relationship between the current change and a glucose-glutamic acid (GAA) concentration up to 60 mg l(-1) was observed (r=0.999). The lower detection limit was 1.0 mg l(-1) BOD. The sensor response was reproducible within +/-5% of the mean in a series of ten samples having 44 mg l(-1) BOD using standard a GGA solution. When used for the BOD estimation of industrial waste-waters, a relatively good agreement was found between the two methods, i.e. 5-day BOD and that measured by the developed microbial sensor.  相似文献   

2.
Aeromonas hydrophila P69.1 (A. hydrophila) was used to construct a semi-specific biosensor to estimate biochemical oxygen demand (BOD) in high fat and grease content wastewaters. A. hydrophila cells were grown in fat containing medium to induce necessary enzymes for transport and degradation of fatty substances. Universal biosensor based on non-specific Pseudomonas fluorescens P75 (P. fluorescens) was used to conduct comparison experiments. Biosensors were calibrated using OECD synthetic wastewater and steady-state method, subsequently several experiments with synthetic and industrial wastewaters were conducted. A linear range up to 45 mg l(-1) BOD(7) was gained using A. hydrophila biosensor, in comparison to 40 mg l(-1) BOD(7) obtained using P. fluorescens biosensors. The lower limit of detection was 5 mg l(-1) BOD(7). Service life of A. hydrophila and P. fluorescens biosensors were 110 and 115 days, respectively. The response time of the biosensors depended on the BOD(7) of measuring solution and was up to 20 min when analyzing different wastewaters. Both biosensors underestimated BOD in meat industry wastewater from 43% up to 71%, but more accurate results could be obtained with A. hydrophila biosensor. Semi-specific A. hydrophila biosensor was able to measure proportion of fat found in wastewater sample, while other refractory compounds remained undetectable to both biosensors.  相似文献   

3.
The microorganisms Trichosporon cutaneum and Bacillus licheniformis were used to develop a microbial biochemical oxygen demand (BOD) sensor. It was found that T. cutaneum gave a greater response to glucose, whereas B. licheniformis gave a better response to glutamic acid. Hence, co-immobilized T. cutaneum and B. licheniformis were used to construct a glucose and glutamic acid sensor with improved sensitivity and dynamic range. A membrane loading of T. cutaneum at 1.1x10(8 )cells ml(-1) cm(-2) and B. licheniformis at 2.2x10(8) cells ml(-1) cm(-2) gave the optimum result: a linear range up to 40 mg BOD l(-1) with a sensitivity of 5.84 nA mg(-1) BOD l. The optimized BOD sensor showed operation stability for 58 intermittent batch measurements, with a standard deviation of 0.0362 and a variance of 0.131 nA. The response time of the co-immobilized microbial BOD sensor was within 5-10 min by steady-state measurement and the detection limit was 0.5 mg BOD l(-1). The BOD sensor was insensitive to pH in the range of pH 6.8-7.2.  相似文献   

4.
The photocatalytic biosensor of flow system using semiconductor TiO2 was developed to evaluate biochemical oxygen demand (BOD) levels in river water. Photocatalysis of sample was carried out in a photoreactor with TiO2 and a 6W black-light blue fluorescent tube as light source. Sample from a photoreactor outlet was measured by an oxygen electrode with a biofilm. The sensor response of photocatalytic biosensor was between 5 and 10 min depending on concentration of biochemical in the samples. At BOD of 1 mgl-1, the sensor response increased 1.33-fold in comparison with that without photocatalysis. The degradation of tannic acid and humic acid with photocatalysis were 51.8 and 38.4%, respectively. Gum arabic and linear alkylbenzene sulfonate (LAS) were degraded a little, but gave the responses of more than double to the sensor. Free radicals yielded by photocatalysis in a photoreactor did not affect the sensor response because their lifetime is extremely short. Fairly good correlation (r=0.983) between the sensor method and the conventional method was obtained for test samples. This biosensor using photocatalytic pretreatment improved the sensitivity.  相似文献   

5.
A novel design of a biochemical oxygen demand (BOD) biosensor has been developed for on-line monitoring of easily biodegradable organic compounds in aqueous samples. The biological recognition element of the sensor could be easily renewed by injecting new bacterial paste without disassembling the sensor system. The sensor measurements were carried out in the initial-rate mode using a flow injection (FI) system, resulting in 60 s for one sample analysis followed by a recovery time less than 10 min. The sensor performance achieved showed a wide detection linearity over the range of 5-700 mg BOD5.l(-1) and a generally good agreement between the BOD values estimated by the biosensor and the conventional 5-day test. Furthermore, the precision test was in the control range (i.e. repeatability < or = /+/-7.5%/, reproducibility < or = /+/-7.3%/). The sensor could be used over 1 week in continuous test, however, the best performance was found within the first 24 h where standard deviation of the sensor response was +/-2.4%. The design of the sensor allows easy and fast renewal of the cells used as sensing elements. Replacement of biological recognition element and calibration of the sensor responses can be performed in a rather simple procedure on a daily regular basis. By using a mixed culture as the bio-receptor, one gets a sensor that reacts to a wide range of substrates. The new sensor construction will thus allow fast and convenient replacement of the bio-receptor and on-line assay of a broad range of substrates. This makes the sensor being an interesting and promising candidate for on-line monitoring of biological treatment process.  相似文献   

6.
Liu C  Ma C  Yu D  Jia J  Liu L  Zhang B  Dong S 《Biosensors & bioelectronics》2011,26(5):2074-2079
To improve the practicability of rapid biochemical oxygen demand (BOD) method, we proposed a stable BOD sensor based on immobilizing multi-species BODseed for wastewater monitoring in the flow system. The activation time of the biofilm was greatly shortened for the biofilm prepared by BODseed in the organic-inorganic hybrid material. Some influence factors such as temperature, pH, and concentration of phosphate buffer solution (PBS) were investigated in detail in which high tolerance to environment was validated for the BOD sensor permitted a wide pH and PBS concentration ranges. The minimum detectable BOD was around 0.5 mg/l BOD under the optimized 1.0 mg/ml BODseed immobilized concentration. The as-prepared BOD sensor exhibited excellent stability and reproducibility for different samples. Furthermore, the as-prepared BOD biosensor displayed a notable advantage in indiscriminate biodegradation to different organic compounds and their mixture, similar to the character of conventional BOD(5) results. The results of the BOD sensor method are well agreed with those obtained from conventional BOD(5) method for wastewater samples. The proposed rapid BOD sensor method should be promising in practical application of wastewater monitoring.  相似文献   

7.
A biochemical oxygen demand (BOD) sensor has been developed, which is based on an immobilized mixed culture of microorganisms combined with a dissolved oxygen (DO) optical fiber. The sensing film for BOD measurement consists of an organically-modified silicate (ORMOSIL) film embedded with tri(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) perchlorate and three kinds of seawater microorganisms immobilized on a polyvinyl alcohol sol-gel matrix. The BOD measurements were carried out in the kinetic mode inside a light-proof cell and with constant temperature. Measurements were taken for 3 min followed by 10 min recovery time in 10 mg/L glucose/glutamate (GGA) BOD standard solution, and the range of determination was from 0.2 to 40 mg/L GGA. The effects of temperature, pH and sodium chloride concentration on the BOD sensing films were studied. BOD values estimated by this optical BOD sensing film correlate well with those determined by the conventional BOD5 method for seawater samples.  相似文献   

8.
A method to determine the spectrophotometric biochemical oxygen demand (BOD(sp)) was studied with high sensitivity and reproducibility by employing 2,6-dichlorophenolindophenol (DCIP) as a redox color indicator, the yeast Saccharomyces cerevisiae, and a temperature-controlling system providing a three-consecutive-stir unit. The absorbance of DCIP decreased due to the metabolism of organic substances in aqueous samples by S. cerevisiae. Under optimum conditions, a calibration curve for glucose glutamic acid concentration between 1.1 and 22mg O(2) L(-1) (r=0.988, six points, n=3) was obtained when the incubation mixture was incubated for 10min at 30 degrees C. The reproducibility of the optical responses in the calibration curve was 1.77% (average of relative standard deviations; RSD(av)). Subsequently, the characterization of this method was studied. The optical responses to pure organic substances and the influence of chloride ions, artificial seawater, and heavy metal ions on the sensor response were investigated before use with real samples. Measurements of real samples using river water were performed and compared with those obtained using the BOD(5) method. Finally, stable responses were obtained for 36 days when the yeast cell suspension was stored at 4 degrees C (response reduction, 89%; RSD(av) value for 9 testing days, 8.4%).  相似文献   

9.
The stopped-flow system with an ozonizer was developed to estimate low biochemical oxygen demand (BOD) in rivers. Rivers contain many biopersistent organic compounds such as humic acid, lignin, and gum arabic. Free radicals generated by self-decomposition of ozone were used as powerful oxidants to split organic compounds. Ozonysis of the samples was carried out by 42.4 g N−1 m−3 ozone for 3 min at pH 7.0. Artificial wastewater (AWW) solutions were employed as standard solutions for the calibrations of the BOD sensor. At a BOD of 1 mg l−1, the sensor response after ozonation was 1.6-fold higher than that before ozonation. The response time of the BOD sensor was only 5 min, being independent of the concentrations, and the lower detection limit was 0.5 mg l−1 BOD. The degradations of lignin and tannic acid by ozonation were 54.1 and 42.3%, respectively. In the biosensor responses by ozonation, lignin, gum arabic, and surfactant increased by double or more compared with previous responses. BOD in rivers was estimated using the stopped-flow system. Environmental samples pretreated with ozone gave high responses to the biosensor that were similar to those of the conventional BOD5 method. Accordingly, a good correlation between the sensor and the conventional BOD5 was obtained (r = 0.989). The system has to evolve the highly sensitive BOD determination.  相似文献   

10.
We characterized a mediator-type biochemical oxygen demand (BOD) sensor with a three-electrode system using potassium ferricyanide (FC) and Pseudomonas fluorescens in our previous study. In the present study, we have utilized the advantages of a mediator-type biosensor, which does not require air-supply equipment for on-site measurements, and made a fully disposable sensor tip for a portable device. The tip consists of a two-electrode system with P. fluorescens immobilized on a cellulose acetate membrane and is packaged in polyester film to prevent it from drying out. By aeration with a 0.1 M NaCl solution of P. fluorescens (after growth), the sensor responses as well as their reproducibility and stability have been successfully improved. The responses increased more than seven times, and the calibration curve from 15 to 260 mg l(-1) also remained linear although the response decreased approximately half the original after at least 35 days in storage. The reproducibility of the sensor responses improved to 12.7% (average of relative standard deviations (RSDs)) in the calibration curve obtained by using the Organization for Economic Cooperation and Development synthetic sewage. Examination of real samples from three different sources showed that the BOD as determined by the sensor correlates well with the conventional 5-day BOD method (r(2)=0.982, 0.823, and 0.809). Consequently, the aeration process makes it possible to realize rapid, and in situ measurements without the long conditioning process that is generally required to activate the microorganisms immobilized on bio-films before use. Finally, we have designed a portable device that utilizes our disposable sensor tip.  相似文献   

11.
A fast estimation of biochemical oxygen demand using microbial sensors   总被引:7,自引:0,他引:7  
Summary Microbial amperometric sensors for biochemical oxygen demand (BOD) determination using Bacillus subtilis or Trichosporon cutaneum cells immobilized in polyvinylalcohol have been developed. These sensors allow BOD measurements with very short response times (15–30s), a level of precision of ±5% and an operation stability of 30 days. A linear range was obtained for a B. subtilis-based sensor up to 20 mg/l BOD and for a T. cutaneum-based sensor up to 100 mg/l BOD using a glucose/glutamic acid standard.  相似文献   

12.
A novel type of biochemical oxygen demand (BOD) biosensor was developed for water monitor, based on co-immobilizing of Trichosporon cutaneum and Bacillus subtilis in the sol-gel derived composite material which is composed of silica and the grafting copolymer of poly (vinyl alcohol) and 4-vinylpyridine (PVA-g-P(4-VP)). Factors that influence the performance of the resulting biosensor were examined. The biodegradable substrate spectrum could be expanded by the co-immobilized microorganisms. The biosensor prepared also exhibited good reproducibility and long-term stability. Good agreement was obtained between the results of the sensor BOD measurement and those obtained from conventional BOD(5) method for water samples.  相似文献   

13.
The titres of physiological processes in bacteria (hydrolysis of urea, nitrification), total number of bacteria and photosynthesis were found to show high correlation with standard characteristics: BOD5 and saprobic index. The classificatory values of BOD5 and saprobic index depend on the pollution of waters (with BOD5 less than 3 mg O2/l more information on the extent of pollution is given by the saprobic index whereas with higher values BOD5 is better). The content of NH3-N and titres of ammonification and H2S production depend on the type of pollution and should not be used for determination of water purity without additional studies. Of increasing importance as a measure of pollution is the BOD5/BOD2 quotient.  相似文献   

14.
A novel BOD sensor based on bacterial luminescence   总被引:4,自引:0,他引:4  
A reagent-type BOD sensor with a new principle employing a luminous bacterium, Photobacterium phosphoreum, was developed. The increased intensity of luminescence resulting from the cellular assimilation of organic compounds in wastewater was detected by a photodiode. The BOD response of the bacterial reagent could be obtained within 15 min with +/-7% error. The temperature condition for optimal BOD response was 18 degrees to 25 degrees C at pH 7 to 8, indicating that it is possible to measure BOD at room temperature without having to stabilize the temperature of the measuring system. For practical use, two procedures for long-term preservation of the bacterial reagent, vacuum drying method and freezing method, are suggested. The metabolic characteristics of employed luminous bacteria were investigated by comparing the BOD values for several pure organic substrates estimated by the BOD sensor with conventional 5-day BOD values. In comparison with the 5-day measurement for some wastewater samples, BOD values estimated by the sensor showed comparatively good agreement with those measured by the 5-day method. (c) 1993 Wiley & Sons, Inc.  相似文献   

15.
Two new yeast strains (SPT1 and SPT2) were isolated and immobilized on glassy carbon electrodes to form microbial biosensors for estimation of biochemical oxygen demand (BOD). Ferricyanide was proven to be the most efficient mediator to shuttle electrons from the redox center of reduced microbial enzymes to the electrode in the presence of excess glucose/glutamic acid (GGA). With a 3-fold greater metabolic assimilation capability and greater responses to various effluent samples, SPT1 was selected for sensor-BOD measurements. BOD estimations for the GGA standard resulted in an extended linear range: 2-100 mg/l. Response reproducibility was +/-10% for a GGA standard containing 10 mg BOD/l. For analysis of pulp mill effluents, the BOD detection limit was 2 mg/l with a response time of 5 min.  相似文献   

16.
A microbial biosensor based on the yeast Arxula adeninivorans LS3 has been developed for measurement of biodegradable substances. Arxula is immobilized in the hydrogel poly(carbamoyl) sulfonate (PCS). The immobilized yeast membrane is placed in front of an oxygen electrode with -600 mV versus Ag/AgCl. Arxula is salt tolerant; it can give a stable signal up to 2.5 M NaCl in sample (120 mM in measuring cell). The sensor's measurements are highly correlated to BOD5 measurements. It has a very high stability which can last for 40 day without any decrease in signal. The linear range of the sensor is up to a corresponding BOD value of 550 mg/l.  相似文献   

17.
Three amperometric biosensors based on immobilization of tyrosinase on a new Sonogel-Carbon electrode for detection of phenols and polyphenols are described. The electrode was prepared using high energy ultrasounds (HEU) directly applied to the precursors. The first biosensor was obtained by simple adsorption of the enzyme on the Sonogel-Carbon electrode. The second and the third ones, presenting sandwich configurations, were initially prepared by adsorption of the enzyme and then modification by mean of polymeric membrane such as polyethylene glycol for the second one, and the ion-exchanger Nafion in the case of the third biosensor. The optimal enzyme loading and polymer concentration, in the second layer, were found to be 285 U and 0.5%, respectively. All biosensors showed optimal activity at the following conditions: pH 7, -200 mV, and 0.02 mol l(-1) phosphate buffer. The response of the biosensors toward five simple phenols derivatives and two polyphenols were investigated. It was found that the three developed tyrosinase Sonogel-Carbon based biosensors are in satisfactory competitiveness for phenolic compounds determination with other tyrosinase based biosensors reported in the literature. The detection limit, sensitivity, and the apparent Michaelis-Menten constant K(m)(app) for the Nafion modified biosensor were, respectively, 0.064, 0.096, and 0.03 micromol, 82.5, 63.4, and 194 nA micromol(-1)l(-1), and 67.1, 54.6, and 12.1 micromol l(-1) for catechol, phenol, and 4-chloro-3-methylphenol. Hill coefficient values (around 1 for all cases), demonstrated that the immobilization method does not affect the nature of the enzyme and confirms the biocompatibility of the Sonogel-Carbon with the bioprobe. An exploratory application to real samples such as beers, river waters and tannery wastewaters showed the ability of the developed Nafion/tyrosinase/Sonogel-Carbon biosensor to retain its stable and reproducible response.  相似文献   

18.
Amperometric estimation of BOD by using living immobilized yeasts   总被引:4,自引:0,他引:4  
Summary A microbial electrode consisting of immobilized living whole cells of yeasts, porous membrane and an oxygen electrode was prepared for continuous estimation of biochemical oxygen demand (BOD). Immobilized Trichosporon cutaneum was employed for the microbial electrode sensor for BOD. When a sample solution containing the equivalent amount of glucose and glutamic acid was injected into the sensor system, the current of the electrode decreased markedly with time until steady state was reached. The response time was within 18 min. A linear relationship was observed between the current decrease and the concentration below 41 mg l of glucose and 41 mg l glutamic acid (5-day BOD 60 mg l ). The current decrease was reproducible within ± 6% of the relative error when a sample solution containing 27 mg l of glucose and 27 mg l of glutamic acid (5-day BOD 40 mg l ) was employed. The microbial electrode sensor was applied to untreated waste waters from a fermentation factory. Good comparative results were obtained between BOD estimated by the microbial electrode and that determined by the conventional 5-day method (regression coefficient was 1.2). Furthermore, the effect of various compounds on BOD estimation was also examined. The current output of the microbial electrode sensor was almost constant for 17 d and 400 tests.  相似文献   

19.
A microbial fuel cell type of biosensor was used to determine the biochemical oxygen demand (BOD) of wastewater. The biosensor gave a good correlation between the BOD value and the coulomb produced. The BOD sensor has been operated for over 5 years in a stable manner without any servicing. This is much longer that that of previously reported BOD biosensors.  相似文献   

20.
生物传感器快速测定BOD的研究   总被引:13,自引:0,他引:13  
生化需氧量(biochemicaloxygendemand,BOD)是一种表征水体有机污染程度的综合指标,广泛应用于水体监测和废水处理厂的运行控制。由于BOD的标准测定方法需时5天,不能及时地反映水质状况和反馈处理信息,因此快速测定BOD的方法和仪器化研究近年来得到广泛的重视。利用生物传感器测定BOD是一种有效地快速测定废水中可生化降解有机物的方法。介绍生物传感器的工作原理及其生物敏感材料,讨论BOD传感器的性能参数以及BOD快速测定值(BODst)与标准BOD5值的一致性问题。对现阶段市场上常见的几种BOD快速测定仪进行简单的介绍,并对它们的性能进行比较 。  相似文献   