首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously determine berberine, palmatine and jatrorrhizine in rat plasma. After mixing with the internal standard (IS) tetrahydropalmatine, plasma samples were pretreated by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatographic separation was carried out on a C18 column using a mixture of water (containing 0.1% formic acid) and acetonitrile (30:70, v/v) as mobile phase. The detection was performed by selected reaction monitoring (SRM) mode via electrospray ionization (ESI) source operating in the positive ionization mode. The method was linear over the concentration range of 1.0-250.0 ng/mL for all components. The intra- and inter-day precision values were less than 14.6% and the deviations were within +/-4.0%. The fully validated LC-MS/MS method has been successfully applied to the pharmacokinetic study of berberine, palmatine and jatrorrhizine in rat plasma after oral administration of coptis-evodia herb couple. Three peaks were observed in both individual and mean plasma-concentration curves of berberine, palmatine and jatrorrhizine, which may be attributed to distribution re-absorption and enterohepatic circulation.  相似文献   

2.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

3.
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid-liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 microm, 150 mmx2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from -5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from -4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.  相似文献   

4.
A sensitive and highly selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine nimodipine in human plasma. The analyte and internal standard nitrendipine were extracted from plasma samples by n-hexane-dichloromethane-isopropanol (300:150:4, v/v/v), and chromatographed on a C(18) column. The mobile phase consisted of methanol-water-formic acid (80:20:1, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI) source. The method has a limit of quantification of 0.24 ng/ml. The linear calibration curves were obtained in the concentration range of 0.24-80 ng/ml. The intra- and inter-day precisions were lower than 4.4% in terms of relative standard deviation (R.S.D.), and the accuracy ranged from 0.0 to 5.8% in terms of relative error (RE). This validated method was successfully applied for the evaluation of pharmacokinetic profiles of nimodipine tablets administered to 18 healthy volunteers.  相似文献   

5.
In the present studies, to give momentum to traditionally low throughput pharmacokinetic screening, a bioanalytical method based on the concept of sample pooling for simultaneous bioanalysis of multiple compounds is discussed. A sensitive, selective, specific and rapid HPLC/ESI-MS/MS assay method was developed and validated for the simultaneous quantitation of three novel trioxane antimalarials (99-357, 99-408 and 99-411) in rat plasma using trioxane analogue as internal standard. The suitably validated bioanalytical method was then further extrapolated to rabbit and monkey plasma by performing partial validation. Extraction from the plasma involves a simple two-step liquid-liquid extraction with n-hexane. The analytes were chromatographed on a cyano column by isocratic elution with acetonitrile:ammonium acetate buffer (pH 6) (85:15, v/v) and analyzed by mass spectrometry in multiple reaction-monitoring (MRM) mode. The chromatographic run time was 5.5 min and the weighted (1/x(2)) calibration curves were linear over a range of 1.56-200 ng/ml. The limit of detection (LOD) and lower limit of quantification (LLOQ) in rat plasma, rabbit plasma and monkey plasma were 0.78 and 1.56 ng/ml, respectively, for all three analytes. The intra- and inter-batch accuracy and precision in terms of % bias and % relative standard deviation were found to be well within the acceptable limits (< 15%). The average absolute recoveries of 99-357, 99-408 and 99-411 from spiked plasma samples were > 90%, > 70% and > 60%, respectively. The assay method described here could be applied to study the pharmacokinetics of 99-357, 99-408 and 99-411 using sample-pooling technique.  相似文献   

6.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

7.
A simple, rapid and accurate liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed and validated for quantification of mangiferin in rat plasma. After the addition of the internal standard (IS) paracetamol, plasma samples were pretreated by protein precipitation. Chromatographic separation was carried out on a C(18) column by isocratic elution with methanol-acetonitrile-1% acetic acid (40:3:57, v/v/v). The detection was performed on a Sciex API 3000 LC/MS/MS with TurboIonSpray ionization (ESI) inlet in the positive ion MRM mode. Good linearity was achieved over the concentration range of 3.01-601 ng/mL. Intra- and inter-day precisions were less than 9.1%, and accuracy ranged from 100.5% to 104.0%. The pharmacokinetic profiles of free mangiferin at three dose levels and mangiferin in Zhimu decoction and Zhimu-Huangbai decoction were studied for the first time in rats by this method. After single intragastric administration of free mangiferin 17.5, 35 and 70 mg/kg, C(max) and AUC increased but non-proportional to the doses. At the same dose level (35 mg/kg), C(max) and AUC of mangiferin in two decoctions were significantly higher than the corresponding values of free mangiferin.  相似文献   

8.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for determination of ibutilide in human plasma. The analyte and internal standard sotalol were extracted from plasma samples by liquid-liquid extraction, and separated on a C(18) column, using acetonitrile-water-10% butylamine-10% acetic acid (80:20:0.07:0.06, v/v/v/v) as the mobile phase. Detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via TurboIonSpray ionization (ESI). Linear calibration curves were obtained in the concentration range of 20-10,000 pg/ml, with a lower limit of quantitation of 10 pg/ml. The intra- and inter-day precision values were below 8% and accuracy was within +/-3% at all three QC levels. The method was utilized to support clinical pharmacokinetic studies of ibutilide in healthy volunteers following intravenous administration.  相似文献   

9.
A new HPLC method was developed for the estimation of carboxylic acid metabolite of clopidogrel bisulfate in rat plasma using atorvastatin as internal standard. Plasma samples were extracted with a mixture of ethyl acetate and di-chloro methane (80:20, v/v) followed by subsequent reconstitution in a mixture of water:methanol:acetonitrile (40:40:20, v/v). The chromatographic separation was achieved with gradient elution on Kromasil ODS, 250 mm x 4.6 mm i.d., 5 microm analytical column maintained at 30 degrees C. Carboxylic acid metabolite of clopidogrel as well as the internal standard were detected at a wavelength of 220 nm. The method was validated as per USFDA guidelines. Calibration curves were linear in the concentration range of 125.0-32,000 ng/ml and the correlation coefficient was better than 0.999. The extraction efficiency for the carboxylic acid metabolite of clopidogrel was more than 85.76%. The intra-day accuracy ranged from 98.9% to 101.5% with a precision of 1.30% to 6.06%. Similarly, the inter-day accuracy was between 96.2% and 101.1% with a precision of 3.47% to 4.30%. The drug containing plasma samples were stable at -70 degrees C for 48 days and at ambient temperature for 24h. In the auto-sampler maintained at 15 degrees C, the processed and reconstituted samples were stable for 35 h. The drug containing frozen plasma samples were stable enough to with stand three freeze thaw cycles. The method was successfully applied to the pharmacokinetic study of the two different polymorphs of clopidogrel bisulfate in Wistar rat.  相似文献   

10.
A sensitive and specific liquid chromatographic method using solid-phase extraction with Sep-pak cartridges has been developed for the determination of Casiopeina IIgly and validated over the linear range 2.5-50 microg/ml in rat plasma. The analysis was performed on a Symetry C(18) (5 microm) column with a Phenomenex C(18) precolumn. The mobile phase was methanol-water (58:42, v/v). The column effluent was monitored at 273 nm. The results showed that the assay is sensitive at 2.5 microg/ml. Maximum intra-day coefficient of variation was 11.47%. The recovery based upon addition of internal standard to rat plasma was 80.98%. The method was used to perform preclinical pharmacokinetic studies in rat plasma and was found to be satisfactory.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method for the determination of sinefungin, a new antiprotozoal drug, in rat plasma has been developed and validated. Sample preparation was performed at 4°C by deproteinization with acetonitrile. Vidarabine was used as an internal standard. Both sinefungin and vidarabine were separated on a C18 column with a mobile phase of ammmonium dihydrogenphosphate-acetonitrile (95:5, v/v) and detected by ultraviolet absorbance at 260 nm. Recoveries of sinefungin from plasma were 75 ± 3.2% and 81 ± 4.8% following dosage at concentrations of 10 μg/ml and 30 μ/ml, respectively. Using 25- μl of rat plasma the limit of quantitation was 1 μg/ml sinefungin, and the assay was linear from 1 to 30 μg/ml. This method appears sensitive enough to be used in further pharmacokinetic studies of sinefungin in animal models.  相似文献   

12.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

13.
Tubeimoside I is an important component isolated from Bolbostemma paniculatum. Tubeimoside I has been demonstrated to possess many pharmacological activities, including anti-inflammatory, antitumor, and antitumor-promoting effects. The purpose of the present study was to examine in vivo pharmacokinetics and bioavailability of tubeimoside I in rats by using a liquid chromatography coupled with mass spectrometry quantitative detection method (LC/MS). The plasma samples were deproteinated, evaporated and reconstituted in 100 microl methanol prior to analysis. The separation was performed by Waters Symmetry C18 reversed-phase column (3.5 microm, 150 mm x 2.1mm, Waters Inc., USA) and a SB-C18 guard column (5 microm, 20 mm x 4.0mm). The mobile phase was a mixture of acetonitrile and water containing 5 microM NaAc (60:40, v/v). The method was validated within the concentration range 20-5000 ng/ml, and the calibration curves were linear with correlation coefficients >0.999. The lowest limit of quantitation (LLOQ) for tubeimoside I was 20 ng/ml in 0.1 ml rat plasma. The intra-assay accuracy and precision ranged from 92.4 to 104.9% and from 5.8 to 10.5%, respectively, while inter-assay accuracy and precision ranged from 94.2 to 95.0% and from 5.1 to 8.8%, respectively. The method was further applied to assess pharmacokinetics and oral bioavailability of tubeimoside I after intravenous and oral administration to rats. The oral bioavailability of tubeimoside I is only 0.23%, which indicates that tubeimoside I has poor absorption or undergoes acid-induced degradation. Practical utility of this new LC/MS method was confirmed in pilot pharmacokinetic studies in rats following both intravenous and oral administration.  相似文献   

14.
A sensitive, specific and rapid liquid chromatography–mass spectrometry (LC–MS) method has been developed and validated for the simultaneous determination of xanthotoxin (8-methoxypsoralen), psoralen, isoimpinellin (5,8-dimethoxypsoralen) and bergapten (5-methoxypsoralen) in rat plasma using pimpinellin as an internal standard (IS). The plasma samples were pretreated by protein precipitation with methanol and chromatographic separation was performed on a C18 column with a mobile phase composed of 1 mmol ammonium acetate and methanol (30:70, v/v). The detection was accomplished by multiple-reaction monitoring (MRM) scanning via electrospray ionization (ESI) source operating in the positive ionization mode. The optimized mass transition ion-pairs (m/z) for quantitation were 217.1/202.1 for xanthotoxin, 187.1/131.1 for psoralen, 247.1/217.0 for isoimpinellin, 217.1/202.1 for bergapten, and 247.1/231.1 for IS. The total run time was 6 min between injections. The calibration curves were linear over the investigated concentration range with all correlation coefficients higher than 0.998. The lower limits of quantitation (LLOQ) of these analytes were less than 1.21 ng/ml. The intra- and inter-day RSD were no more than 9.7% and the relative errors were within the range of ?8.1% to 4.5%. The average extraction recoveries for all compounds were between 90.7% and 106.2%. The proposed method was further applied to the determination of actual plasma samples from rats after oral administration of Radix Glehniae extract.  相似文献   

15.
A rapid and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) had been developed and validated to determine the concentrations of BPR0L075 in rat plasma. After a simple protein precipitation of plasma samples by acetonitrile, BPR0L075 was analyzed on a C(8) column at a flow rate of 0.5 mL/min. The mobile phase consisted of a mixture of 10 mM ammonium acetate containing 0.1% formic acid and acetonitrile (20:80, v/v). Both BPR0L075 (analyte) and the internal standard (BPR0L092) were determined using electro-spray ionization and the MS data acquisition was via multiple reactions monitoring (MRM) in positive scanning model. The MS/MS ion transitions monitored are m/z 342.2/195.2 and 312.5/165.2 for BPR0L075 and BPR0L092, respectively. The low limit of quantitation was 0.5 ng/mL. Each plasma sample was chromatographed within 5 min. The method was validated with respect to linearity, accuracy, precision, recovery, and stability. A good linear relationship was observed over the concentration range of 0.5-1000 ng/mL (r>0.9994). Absolute recoveries ranged from 63.45 to 68.34% in plasma at the concentrations of 2, 40, 400, and 800 ng/mL. The intra- and inter-day accuracy ranged from 92.04 to 111.80%. Intra- and inter-day relative standard deviations were 1.08-3.29% and 1.96-5.46%, respectively. This developed and validated assay method had been successfully applied to a pharmacokinetic study after intravenous injection of BPR0L075 in rats at a dose of 5mg/kg.  相似文献   

16.
Oxytocin (OT) is a neuropeptide with an extremely low endogenous level (low pg/ml) in human plasma. It is very challenging to develop a highly sensitive assay to measure endogenous OT, including radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA). Electrospray ionization (ESI) liquid chromatography–tandem mass spectrometry (LC–MS/MS) can provide high-throughput and selective methods for quantification of peptides in biological samples. A novel and highly sensitive two-dimensional LC–MS/MS (2D-LC–MS/MS) assay combining solid-phase extraction (SPE) has been developed and validated for the determination of endogenous OT in both human and rat plasma. The lower limit of quantification (LLOQ) was 1.00 pg/ml for human and 50.0 pg/ml for rat. Human plasma diluted with water (1:6, v/v) was successfully optimized as a surrogate matrix for human to prepare standard curves without endogenous interference. The extraction efficiency and absolute recovery were above 65.8% using the HLB SPE procedure, and matrix effects were lower than 12%. The method was validated in the range of 1.00–250 pg/ml for human plasma and 50.0–10,000 pg/ml for rat plasma with precision less than 12.7% and accuracy less than 7%.  相似文献   

17.
Recently a novel class of non-competitive AMPA receptor (AMPAR) antagonists, such as, N-acetyl-1-(p-chlorophenyl)-6,7-dimethoxy-1,2,3,4-tetrahydroisoquinoline (PS3Ac) have been developed using molecular modeling studies. In this study we present a validated method for detecting PS3Ac in biological matrices by high performance liquid chromatography with ultraviolet detection. In this study PS3Ac was administered to Wistar rats. After intraperitoneal administration, the plasma concentrations of PS3Ac and its potential metabolic products, i.e., PS3OH, PS3 and PS3OHAc were determined. Serum samples (0.5 ml) were purified by solid-phase extraction of analytes using Oasis cartridges. The chromatographic separation was performed on a LiChrosorb RP-1 at 30 degrees C. The eluent was made of potassium dihydrogen phosphate/acetonitrile in ratio of 50:50 (v/v); the flow rate was 1 ml/min. The detection was performed at 220 nm. The method exhibited a large linear range from 0.05 to 5 microg/ml for all studied compounds. The intra-assay accuracy ranged from 92% determined at 0.1 microg/ml of PS3OH, to 108% determined at 0.05 microg/ml of PS3OHAc. The average coefficient of variation of inter-assay was 6.27%. The average recovery from plasma was 78.5%. The limits of quantification for all the tetrahydroisoquinoline derivatives was 20 ng. The method proved to be highly sensitive and specific for the determination of the studied compounds in rat plasma and has been successfully applied to the evaluation of the pharmacokinetic profile of the inoculated compound.  相似文献   

18.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of beraprost, a stable, orally active prostacyclin analogue with vasodilatory, antiplatelet and cytoprotective effects. The analyte and internal standard, indomethacin, were extracted by solid-phase extraction using OASIS HLB cartridge. The chromatographic separation was performed on a C18 column with a mobile of 0.1% formic acid-methanol (30:70, v/v). The highest daughter ion of deprotonated analyte was quantitated in negative ionization by multiple reactions monitoring with a mass spectrometer. The mass transitions m/z 397>269 and m/z 356>312 were used to measure beraprost and internal standard, respectively. The assay exhibited a linear range from 0.02 to 2 ng/mL for beraprost in human plasma. The lower limit of quantitation was 20 pg/mL with a relative standard deviation of less than 20%. The method was validated with respect to linearity, sensitivity, specificity, recovery, accuracy and precision. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic study.  相似文献   

19.
A simple and specific HPLC assay for simultaneous determination of two major active components (-) epigallocatechin-3-gallate (EGCG), and (-) epicatechin-3-gallate (ECG) of tea polyphenols (TP) in rat plasma was developed and validated. Following addition of resorcinol as internal standard (IS) the analytes were isolated from rat plasma by liquid-liquid extraction with ethyl acetate. The chromatographic separation was achieved on a reversed-phase C18 column using an isocratic mobile phase consisting of 0.1% citric acid+CH(3)CN (86:14, v/v) running at flow rate of 1.5 mL/min. The effluent was monitored at a wavelength of 280 nm. EGCG, ECG and IS were well separated from each other and free from interference from blank plasma and other components in TP as well as metabolites post-dosing. The calibration curve was constructed by plotting peak area ratio of analytes to IS vs. concentration. The method showed good linearity over range of 0.5-300 microg/mL for EGCG and 0.1-60 microg/mL for ECG (r>0.999). The intra- and inter-day precision (R.S.D.) was better than 6 and 12%, respectively. Assay accuracy was better than 94.78% for both compounds. Extraction recovery at QC samples was between 85.73 and 91.93% for EGCG and 79.08 and 86.51% for ECG. The developed method was successfully used to simultaneously measure plasma concentrations of EGCG and ECG after intravenous administration of TP to rats and yielded two typical biexponential decay concentration-time curves.  相似文献   

20.
A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and all samples and standard solutions were chromatographed at 45°C using triethylamine solution (0.5%, v/v, pH 3.0±0.1), methanol and acetonitrile (63:30:7, v/v/v) as the mobile phase. Chromatographic resolution was achieved using a RP-C(18) column (Atlantis, Waters, 150 mm × 4.6 mm, 5 μm) at a flow rate of 1.0 mL min(-1) and an injection volume of 30 μL. The analytes were measured by fluorescence detection with excitation and emission wavelengths of 344 nm and 399 nm, respectively. The retention times for GEM and I.S. were approximately 7.5 and 12.6 min, respectively. The lower limit of quantitation (LLOQ) was 20 ng mL(-1) and the calibration curves were linear over a concentration range of 20-5000 ng mL(-1). The intra- and inter-day precisions, expressed by relative standard deviation (R.S.D.) were lower than 6.24% and 4.49%, respectively. The accuracy ranged from 91.3% to 112% and from 98.8% to 106% for the lower and upper limit of quantitation of the calibration curve, respectively. Ratio of peak area of analyte to I.S. was used for quantification of plasma samples. No interferences from endogenous substances were found. The recovery of GEM and I.S. from plasma was greater than 90%. Drug stability in plasma was shown at room temperature for 4h, after three freeze-thaw cycles for 24h, in freezer at -80°C for 60 days, and in the autosampler after processing for 12h. The utility of the assay was confirmed by the successful analysis of plasma samples from GEM pharmacokinetics studies in the rats after intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号