1.
A rapid and precise method for the identification and quantification of cysteinyl leukotrienes (leukotriene C(4), leukotriene D(4) and leukotriene E(4)), essential markers of bronchial asthma, in exhaled breath condensate was developed. The protocol consists of immunoaffinity separation and a detection step, liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized with a high precision (≤ 7.7%, determined as RSD), an acceptable accuracy (90.4-93.7%, determined as recovery), a low limit of detection (≤ 2 pg/ml EBC) and a low limit of quantification (≤ 10 pg/ml EBC). It was compared to other simple, clinically appropriate combinations of pre-treatment methods (solid phase extraction and lyophilization) with LC/MS. Finally, the method (a combination of immunoaffinity separation with LC-MS) was successfully tested in a clinical study where a significant difference was found in the concentration levels of cysteinyl leukotrienes between patients with occupational bronchial asthma and healthy subjects.  相似文献   

2.
The quantitative determination of 3-nitro-l-tyrosine, a biological marker for inflammatory processes, in exhaled breath condensate (EBC) is described. The clean-up and preconcentration was performed by solid phase extraction (SPE). After liquid chromatography the specific detection was performed by tandem mass spectrometry using electron spray ionisation and selected reaction monitoring (SRM). 13C9-3-nitrotyrosine was used as an internal standard. For reliability, tests for the precision of the method, the losses during preparation, a test for nitrating artifacts and the comparibility of calibrants in EBC and buffer solution were performed. The calibration of the method was linear over a range of 10-500 pg/mL. The within-run coefficients of variation (CV) of the samples were found to be 8.4% at 25 pg/mL and 8.3% at 250 pg/mL. The day-to-day CV was found to be 11.2%. The limit of quantification was 3.9 pg/mL. The losses during preparation were 15%. The discrepancy between the calibration with EBC and buffer solution was below 10%. No artificial production of 3-nitrotyrosine was observed during the procedure. The application of the method on the EBC samples of healthy smokers (N=10) and non-smokers (N=10) showed no difference between the two groups. The concentration of 3-nitrotyrosine ranged between the limit of quantification and 184 pg/mL and was distinctly lower than data detected by an immunoassay procedure. The procedure was proven to be accurate, sensitive and in contrast to GC methods less elaborate and is recommended for the determination of 3-nitrotyrosine in exhaled breath condensate.  相似文献   

3.
Here, the possibility of proteomic and metabolomic analysis of the composition of exhaled breath condensate of neonates with respiratory support. The developed method allows non-invasive collecting sufficient amount of the material for identification of disease-specific biomarkers. Samples were collected by using a condensing device that was incorporated into the ventilation system. The collected condensate was analyzed by liquid chromatography coupled with high resolution mass spectrometry and tandem mass spectrometry. The isolated substances were identified with a use of databases for proteins and metabolites. As a result, a number of compounds that compose the exhaled breath condensate was determined and can be considered as possible biomarkers of newborn diseases or stage of development.  相似文献   

4.
Exhaled breath condensate (EBC) contains many substances, which could help in diagnosis of occupational asthma. The aim of the study is to monitor leukotrienes (LT) and 8-isoprostane from EBC in bronchoprovocation tests with allergens in 47 patients with suspected occupational asthma. Forty-one patients were tested negative. In negative bronchoprovocation tests, no significant differences (P<0.05) were seen between the five measurements during and after the test. In control measurements (without provocation), significant differences were found among four measurements done within 24h for 8-isoprostane (P=0.0138). The relationship between the log transformed ratios of the EBC parameters and FEV(1) was never significant at the 5% level in control measurements, while in negative tests, statistical significance was recorded for LTB(4) (P=0.0299) before and 5h after the test. Six of 47 patients were tested positive. Such a small number of patients did not allow proper statistical analysis and therefore, the results are described separately for each patient.  相似文献   

5.
Retention of foetal membranes (RFM) in cows is supposed to be associated with the imbalance between production and neutralisation of reactive oxygen species (ROS). The consequence of uncontrolled ROS increase is oxidative damage to tissues, cells, and macromolecules. 8-iso-prostaglandin F2alpha (8-iso-PGF2alpha) is considered as a marker of oxidative tissue damage. The aim of the study was to investigate whether the concentrations of 8-iso-PGF2alpha, in caruncles and cotyledons from the bovine placenta differ between retained and properly released foetal membranes. Placentomes were collected immediately after either spontaneous delivery at term via the vagina or caesarean section before as well as at term through the incision and divided into six groups consisting of eight cows each as follows: A-preterm caesarean section without RFM, B-preterm caesarean section with RFM, C-term caesarean section without RFM, D-term caesarean section with RFM, E-term spontaneous delivery without RFM, F-term spontaneous delivery with RFM. The concentrations of free and total 8-iso-PGF2alpha, were determined in caruncles as well as cotyledons by enzyme immunoassay and expressed in picogram per gram of wet weight of tissue. The concentrations of free and total 8-iso-PGF2alpha were lower (P < 0.05) in cotyledons than in caruncles in all groups examined, as well as they were higher (P < 0.05) in retained than in released placenta. The concentrations of both parameters were lower (P < 0.05) in term spontaneous delivery groups than in term caesarean section groups. The results indicate that oxidative tissue damage, which may be the result of ROS imbalance, appears during RFM. However, the dynamics of this damage requires further elucidation.  相似文献   

6.
Isoprostanes are a family of prostaglandin (PG) F and E isomers generated by free-radical attack from membrane bound arachidonic acid. We measured detectable levels of 8-iso-PGF(2alpha) in the perfusates of synaptosomes obtained from different areas of the rat brain cortex. A small but significant release of this isoprostane was found under basal conditions from all the areas explored; being lower in the dorsal cortex in respect to the frontal, parietal and occipital areas. Exposure of synaptosomes to a phospholipase A(2) activator, i.e. calcium-ionophore A23187, an oxidant agent, such as hydrogen peroxide or amyloid beta-peptide did not modify 8-iso-PGF(2alpha) release when these stimuli were applied separately. However, either hydrogen peroxide or amyloid beta-peptide increased 8-iso-PGF(2alpha) release in a dose-dependent manner, when given in the presence of the calcium-ionophore A23187. Synaptosome treatment with a non-selective cyclooxygenase inhibitor (fenoprofen) did not modify 8-iso-PGF(2alpha) release in any way, but treatment with a water soluble antioxidant (Trolox C) completely suppressed isoprostane release under basal conditions, as well as after the oxidant injury induced either by hydrogen peroxide or amyloid beta-peptide. We conclude that, in neuronal endings, 8-iso-PGF(2alpha) is generated under basal conditions and its formation may be increased in a dose-dependent fashion by oxidant stimuli through a cyclooxygenase-independent mechanism involving free radical-catalyzed oxidation of arachidonic acid on membrane phospholipids.  相似文献   

7.
An improved and simplified high-performance liquid chromatographic (HPLC) method at UV detection 265 nm is presented for the determination of d4T in rat plasma. The mobile phase consists of methanol-distilled water-acetic acid in the 23:77:0.2 (v/v) ratio. Quantification is achieved by the peak-area ratio method with reference to the internal standard. This paper presents linearity, accuracy, precision, limit of quantification and limit of detection, specificity-selectivity and sample stability data. Based on the intra and inter-day validation, all coefficients of variation (CV) were found less than 15%. The assay is sufficiently rapid and sensitive and was applied in a pharmacokinetic study in rats.  相似文献   

8.
8-iso-prostaglandin F(2 alpha)(8-iso-PGF(2 alpha)), a representative isoprostane, has been reported to be a reliable marker for oxidant stress in vivo. To examine if 8-iso-PGF(2 alpha)is generated in patients with acute myocardial infarction (AMI), we measured the level of immunoreactive 8-iso PGF(2 alpha)in the great cardiac vein as well as classical eicosanoids, 6-keto-prostaglandin F(1 alpha)(6-keto-PGF(1 alpha)) and thromboxane B(2)(TXB(2)) in the process of urgent coronary balloon angioplasty. Fourteen patients with anterior AMI were divided into two groups: the totally occluded (n=7) and the already perfused groups (n=7). In the former, transient elevation of 8-iso-PGF(2 alpha)was observed immediately after the angioplasty, i.e. the ratio of post-angioplasty level to pre-level was approximately 2.4 for 8-iso-PGF(2 alpha), 14 for 6-keto-PGF(1 alpha), and 5 for TXB(2). In the already perfused group, the levels of these eicosanoids were unchanged. In the totally occluded group, peak creatine phosphokinase in a peripheral vein was correlated with the level of 8-iso-PGF(2 alpha)(r(2)=0.841, P<0.01), but not with those of the other two eicosanoids. In conclusion, transcardiac 8-iso-PGF(2 alpha)generation is a reliable marker for the size of myocardium exposed to oxidant stress.  相似文献   

9.
As a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from healthy individuals. Using a multiplex fluorescent bead immunoassay, we detected EPO in EBC, as well as tumour necrosis factor-alpha (TNF-alpha) in 13 out of 22 patients simultaneously (EPO 0.21 +/- 0.03 in U/mL and TNF-alpha 34.6 +/- 4.2 in pg/mL, mean +/- SEM). No significant differences for EPO levels or correlation between EPO and TNF-alpha were found but TNF-alpha was significantly higher in patients with chronic obstructive pulmonary disease (COPD) than in non-COPD (obstructive sleep apnoea, OSA, and lung healthy patients). This is the first report of detection of EPO in EBC. Due to the small study size more data is needed to clarify the role of EPO in EBC.  相似文献   

10.
11.
Liquid chromatography-tandem mass spectrometry (LC/MS-MS) was applied to the quantitative analysis of urinary 8-epi-prostaglandin F(2alpha) (8-epi-PGF(2alpha)) level. 8-Epi-PGF(2alpha) and its internal standard, [(2)H(4)]-8-epi-PGF(2alpha), were extracted from urine by using a solid phase extraction cartridge and loaded to LC/MS-MS in selected reaction monitoring (SRM) mode. The standard curve showed good linearity in the range of 40 pg to 10 ng (r = 0. 997). The accuracy of the added 8-epi-PGF(2alpha) ranged from 96.8 to 104.9% with a mean +/- SD of 99.5+/-2.5%. The average level +/- SD of urinary 8-epi-PGF(2alpha) in 13 healthy volunteers (five women and eight men, 31+/-7.4 years old) was 429.4+/-149.6 pg/mg creatinine. The level of seven patients with noninsulin dependent diabetes mellitus (two women and five men, 40+/-13.6 years old), 630.9+/-275.6 pg/mg creatinine, was statistically higher than that of healthy volunteers (P<0.05). This finding suggested that diabetics are in a highly oxidative condition. This simple and rapid LC/MS-MS method can be used to elucidate the pathophysiological feature of diabetes or for monitoring the curative effect.  相似文献   

12.
Yang PC  Fang WD  Huang SY  Chung WB  Hsu WH 《Theriogenology》1996,46(7):1289-1293
We studied the effect of prostaglandin (PG) F(2alpha)-AGN 190851 on farrowing induction and compared it with that of PGF(2alpha)-oxytocin. Eighty crossbred, multiparous sows were randomly assigned to the following 4 treatment groups of 20 sows each: 1) control, saline-saline; 2) PGF(2alpha) (10 mg/sow)-oxytocin (30 IU/sow); 3) PGF(2alpha) (10 mg/sow)-AGN 190851 (0.06 mg/kg); and 4) PGF(2alpha) (10 mg/sow)-AGN 190851 (0.1 mg/kg). Either PGF(2alpha) or saline was administered intramuscularly on Day 111 of gestation at 11:30 h; AGN 190851, oxytocin or saline was administered intramuscularly 20 h after the first injection. The PGF(2alpha)-AGN 190851 (0.1 mg/kg) treated sows had the shortest mean farrowing interval (2.1 +/- 1.6 h, mean +/- SD) compared with the remaining treatment groups (control: 67.1 +/- 26.2 h; PGF(2alpha)-oxytocin: 5.6 +/- 6.7 h; PGF(2alpha)-AGN 190851 [0.06 mg/kg]: 3.0 +/- 2.8 h). Duration of farrowing, litter size, litter weight and interval from weaning to first estrus in sows were not significantly changed by these treatments. The PGF(2alpha)-oxytocin group had a significantly higher stillbirth rate than the control group, whereas the PGF(2alpha)-AGN 190851 (0.1 mg/kg) group had the lowest number of pigs born dead and stillbirth rate among the 4 treatment groups. These results suggested that the PGF(2alpha)-AGN 190851 combination can be used as an alternative method to PGF(2alpha)-oxytocin for synchronizing farrowing.  相似文献   

13.
The hypothesis according to which iron overload could be harmful has been extensively and controversially discussed in the literature. One underlying pathological mechanism may be elevated oxidative stress. Thus, we studied the correlation between hemochromatosis and an established marker of oxidative stress, 8-iso-prostaglandin F2alpha (8-iso-PGF2alpha, iPF2alpha-III, 15-F2t-IsoP). We enrolled 21 patients with hemochromatosis, positive for the homozygous C282Y mutation in the HFE gene, and 21 healthy controls frequency-matched by age and gender in a case-control study design. The objective was to show that iron overload in HFE-related hemochromatosis is associated with increased oxidative stress assessed through 8-iso-PGF(2alpha) urinary excretion, and that oxidative stress is impacted by iron-removal treatment (phlebotomy). Study parameters were transferrin saturation, 8-iso-PGF(2alpha) urine excretion, transferrin, ferritin, serum iron, and vitamins A and E for all participants. Iron concentration in the liver and non-transferrin-bound iron were measured in patients only. We found a significant difference in 8-iso-PGF2alpha in patients (245 [interquartile range 157-348] pg/mg creatinine) compared with controls (128 [106-191] pg/mg creatinine, P = 0.002). Vitamin A was significantly reduced in cases (0.34 [0.25-1.83] microg/ml compared to 3.00 [2.11-3.39] microg/ml, P < 0.001), while vitamin E did not show a significant difference in cases (14.7 [11.5-18.1] microg/ml) compared with controls (14.9 [13.1-19.2] microg/ml, P = 0.52). After phlebotomy treatment and normalization of the iron parameters in the hemochromatosis group, serum vitamin A levels were significantly increased (1.36 [1.08-1.97] microg/ml, P = 0.035 vs. baseline, P < 0.001 vs. controls) and 8-iso-PGF2alpha urinary excretion was lowered to control levels (146 [117-198] pg/mg creatinine, P = 0.38 vs. controls). In our study, HFE-related hemochromatosis was associated with increased oxidative stress and hypovitaminemia A in C282Y homozygotes. The increased oxidative stress was reversible by normalization of the iron load by phlebotomy. Thus, phlebotomy is an effective and adequate means for reducing oxidative stress in these patients.  相似文献   

14.
This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the 'ECoScreen' in healthy calves (body weight 63-98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system 'ECoCheck'. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138-624 nmol l-1 EBC or 0.10-0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC-H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC-pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC-pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

15.
Abstract

This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the ‘ECoScreen’ in healthy calves (body weight 63–98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system ‘ECoCheck’. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138–624 nmol l?1 EBC or 0.10–0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC–H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC–pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC–pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

16.
CD163 is a membrane glycoprotein of the cysteine-rich scavenger receptor superfamily. Upon an inflammatory stimulus CD163 undergoes ectodomain shedding and the soluble protein has been shown to play a role in downregulation of inflammation. The purpose of the present study was to identify a physiological activator of CD163 shedding that is consistently present under inflammatory conditions. Therefore, we elucidated whether oxidative stress or 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)) is involved in shedding of CD163. Oxidative stress induced by H(2)O(2) or a NO donor as well as 8-iso-PGF(2alpha) induced significant shedding of CD163. In contrast, release of CD163 was not stimulated by PGF(2alpha). We identified both calcium and reactive oxygen species as common cellular mediators of CD163 release. Since shedding of both CD163 and tumor necrosis factor-alpha (TNFalpha) is known to be mediated by a TIMP-3-sensitive metalloproteinase we examined whether release of TNFalpha was induced by the same mediators that trigger shedding of CD163. Only oxidative stress generated by H(2)O(2) as well as 8-iso-PGF(2alpha) and PGF(2alpha) enhanced TNFalpha secretion. Thus, we identified novel common and divergent activators of shedding of CD163 and TNFalpha. These inducers of shedding are present in inflammation and might play an important role in membrane protein cleavage.  相似文献   

17.
Reactive nitrogen species can cause oxidative modifications of certain amino acid residues in proteins, notably the modification of tyrosine to 3-nitrotyrosine (3-NT), which is a potentially useful marker of oxidative stress. Since lung diseases are associated with airway inflammation and oxidative stress, quantification of 3-NT in exhaled breath condensate (EBC) may provide a non-invasive means for monitoring ongoing inflammatory processes. 3-NT-like immunoreactivity has previously been detected in EBC, but no definitive evidence for the presence of 3-NT in EBC is available. Here, a method based on gas chromatography/negative ion chemical ionization/tandem mass spectrometry was established for the quantification of free 3-NT in EBC. The detection limit was 0.56 pM (corresponding to 3.0 amol microl(-1) sample injected) and the method was found to give linear results (r2 > 0.999) in the concentration range of 0-5.0 nM. The coefficient of variation (CV) for within-day and between-day precision were 11 and 12%, respectively. No artifactual nitration was observed during sample processing. The method was applied to study subjects with asthma (n = 8), and healthy subjects (n = 10), but only a slight non-significant increase in 3-NT levels was found in the former group (median [interquartile ranges]; 99 [50-547] amol s(-1) vs. 75 [35-147] amol s(-1)). No correlation with exhaled nitric oxide (NO), pulmonary function or EBC levels of total protein was observed. The 3-NT levels were much lower compared to previously reported levels, based on immunochemical measurements. The method does not allow the simultaneous quantification of tyrosine in samples.  相似文献   

18.

Background

Airway eosinophilia is considered a central event in the pathogenesis of asthma. Eotaxin plays a key role in selective eosinophil accumulation in the airways and, subsequently, their activation and degranulation. The study was undertaken to evaluate eotaxin-1 levels in the exhaled breath condensate (EBC) of asthmatics with different degrees of asthma severity and to establish the possible correlation of these measurements with other recognized parameters of airway inflammation.

Methods

EBC was collected from 46 patients with allergic asthma (14 with steroid-naïve asthma, 16 with ICS-treated, stable asthma, 16 with ICS-treated unstable asthma) and 12 healthy volunteers. Concentrations of eotaxin-1 were measured by ELISA.

Results

In the three groups of asthmatics, eotaxin-1 concentrations in EBC were significantly higher compared with healthy volunteers (steroid-naïve asthma: 9.70 pg/ml ± 1.70, stable ICS-treated asthma: 10.45 ± 2.00, unstable ICS-treated asthma: 17.97 ± 3.60, healthy volunteers: 6.24 ± 0.70). Eotaxin-1 levels were significantly higher in patients with unstable asthma than in the two groups with stable disease. We observed statistically significant correlations between the concentrations of eotaxin-1 in EBC and exhaled nitric oxide (FENO) or serum eosinophil cationic protein (ECP) in the three studied groups of asthmatics. We also discovered a significantly positive correlation between eotaxin-1 in EBC and blood eosinophil count in the groups of patients with unstable asthma and steroid-naïve asthma.

Conclusions

Measurements of eotaxin-1 in the EBC of asthma patients may provide another useful diagnostic tool for detecting and monitoring airway inflammation and disease severity.  相似文献   

19.
Samples of exhaled breath condensate (EBC) provide a convenient and non-invasive method to study inflammation in lung diseases. The aim of the present study was to evaluate and compare the inflammatory protein mediator levels in EBC from healthy donors (HD) and from patients with exacerbation of chronic obstructive pulmonary disease (COPD) using an EBC collection device with and without a coating of albumin as a carrier. We studied 13 HD and 26 patients with exacerbation of COPD. The concentrations of myeloperoxidase (MPO), IFNγ and secretory leukocyte protease inhibitor (SLPI) in EBC were measured by immunoassays. The EBC samples from HD and COPD patients showed higher concentrations of MPO when samples were recovered with an albumin-coated device. Furthermore, levels of MPO in COPD patients were significantly higher than in HD. An inverse correlation was observed between MPO and spirometric parameters (FVC and FEV1). Almost all samples collected with the albumin-coated device showed higher amounts of IFNγ and SLPI than those collected with the uncoated device. The levels of SLPI in COPD patients were significantly higher than in HD. A direct correlation was observed between FVC% predicted and SLPI. We concluded that coating the collection device with albumin increased the sensitivity of the technique, at least for measurements of MPO, SLPI and IFNγ. Furthermore, the higher levels of MPO and SLPI and lower levels of IFNγ in EBC from COPD patients could reflect the immunological status and the response of lung parenchyma to treatment during the exacerbation of the illness.  相似文献   