Damage development in cemented acetabular replacements has been studied in bovine pelvic bones under long-term physiological loading conditions, including normal walking, stair climbing and a combined block loading with representative routine activities. The physiological loading conditions were achieved using a specially designed hip simulator for fixation endurance testing. Damage was detected and monitored using micro-CT scanning at regular intervals of the experiments, and verified by microscopic studies post testing. The results show that debonding at the bone–cement interface defined the failure of cement fixation in all cases, and debondings initiated near the dome of the acetabulum in the superior–posterior quadrant, consistent with the high-stress region identified from the finite element analysis of implanted acetabular models Zant, N.P., Heaton-Adegbile, P., Hussell, J.G., Tong, J., 2008b. In-vitro fatigue failure of cemented acetabular replacements—a hip simulator study. Journal of Biomechanical Engineering, Transactions of the ASME, 130, 021019-1–9]; [Tong, J., Zant, N.P., Wang, J-Y., Heaton-Adegbile, P., Hussell, J.G., 2008. Fatigue in cemented acetabulum. International Journal of Fatigue, 30(8), 1366–1375].  相似文献   

2.
The integrity of bone-cement interface is essential for the long-term stability of cemented total joint arthroplasty. Although several studies have been carried out on bone-cement interface at continuum level, micromechanics of the interface has been studied only recently for tensile and shear loading cases. Fundamental studies of bone-cement interface at microstructural level are critical to the understanding of the failure processes of the interface, where multiple factors may contribute to failure. Here we present a micromechanical study of bone-cement interface under compression, which utilised in situ mechanical testing, time-lapsed microcomputed tomography (CT) and finite element (FE) modelling. Bovine trabecular bone was used to interdigitate with bone cement to obtain bone-cement interface samples, which were tested in step-wise compression using a custom-made loading stage within the μCT chamber. A finite element model was built from the CT images of one of the tested samples and loaded similarly as in the experiment. The simulated stress-displacement response fell within the range of the experimental responses, and the predicted local strain distribution correlated well with the failure pattern in the subject-specific experimental model. Damage evolution with load in the samples was monitored both experimentally and numerically. The results from the FE simulations further revealed the development of damage in the regions of interest during compression, which may be useful towards a micromechanics understanding of the failure processes at bone-cement interface.  相似文献   

3.
Although hip simulators for in vitro wear testing of prosthetic materials used in total hip arthroplasty (THA) have been available for a number of years, similar equipment has yet to appear for endurance testing of fixation in cemented THA, despite considerable evidence of late aseptic loosening as one of the most significant failure mechanisms in this type of replacements. An in vitro study of fatigue behavior in cemented acetabular replacements has been carried out, utilizing a newly developed hip simulator. The machine was designed to simulate the direction and the magnitude of the hip contact force under typical physiological loading conditions, including normal walking and stair climbing, as reported by Bergmann et al. (2001, Hip 98, Freie Universitaet, Berlin). A 3D finite element analysis has been carried out to validate the function of the hip simulator and to evaluate the effects of boundary conditions and geometry of the specimen on the stress distribution in the cement mantle. Bovine pelvic bones were implanted with a Charnley cup, using standard manual cementing techniques. Experiments were carried out under normal walking and descending stairs loading conditions with selected load levels from a body weight of 75-125 kg. Periodically, the samples were removed from the test rigs to allow CT scanning for the purpose of monitoring damage development in the cement fixation. The hip simulator was found to be satisfactory in reproducing the hip contact force during normal walking and stair climbing, as reported by Bergmann et al. Finite element analysis shows that the stress distributions in the cement mantle and at the bone-cement interface are largely unaffected by the geometry and the boundary conditions of the model. Three samples were tested up to 17 x 10(6) cycles and sectioned post-testing for microscopic studies. Debonding at the bone-cement interface of various degrees in the posterior-superior quadrant was revealed in these samples, and the location of the failures corresponds to the highest stressed region from the finite-element analysis. Preliminary experimental results from a newly developed hip simulator seem to suggest that debonding at the bone-cement interface is the main failure mechanism in cemented acetabular replacements, and descending stairs seem to be more detrimental than normal walking or ascending stairs with regard to fatigue integrity of cement fixation.  相似文献   

4.
Bone-cement interface has been investigated under selected loading conditions, utilising experimental techniques such as in situ mechanical testing and digital image correlation (DIC). However, the role of bone type in the overall load transfer and mechanical behaviour of the bone-cement construct is yet to be fully quantified. Moreover, microdamage accumulation at the interface and in the cement mantle has only been assessed on the exterior surfaces of the samples, where no volumetric information could be obtained. In this study, some typical bone-cement interfaces, representative of different fixation scenarios for both hip and knee replacements, were constructed using mainly trabecular bone, a mixture of trabecular and cortical bone and mainly cortical bone, and tested under static and cyclic compression. Axial displacement and strain fields were obtained by means of digital volume correlation (DVC) and microdamage due to static compression was assessed using DVC and finite element (FE) analysis, where yielded volumes and strains (εzz) were evaluated. A significantly higher load was transferred into the cement region when mainly cortical bone was used to interdigitate with the cement, compared with the other two cases. In the former, progressive damage accumulation under cyclic loading was observed within both the bone-cement interdigitated and the cement regions, as evidenced by the initiation of microcracks associated with high residual strains (εzz_res).  相似文献   

5.
The acetabular labrum is believed to have a sealing function. However, a torn labrum may not effectively prevent joint fluid from escaping a compressed joint, resulting in impaired lubrication. We aimed to understand the role of the acetabular labrum in maintaining a low friction environment in the hip joint. We did this by measuring the resistance to rotation (RTR) of the hip, which reflects the friction of the articular cartilage surface, following focal and complete labrectomy. Five cadaveric hips without evidence of osteoarthritis and impingement were tested. We measured resistance to rotation of the hip joint during 0.5, 1, 2, and 3 times body weight (BW) cyclic loading in the intact hip, and after focal and complete labrectomy. Resistance to rotation, which reflects articular cartilage friction in an intact hip was significantly increased following focal labrectomy at 1-3 BW loading, and following complete labrectomy at all load levels. The acetabular labrum appears to maintain a low friction environment, possibly by sealing the joint from fluid exudation. Even focal labrectomy may result in increased joint friction, a condition that may be detrimental to articular cartilage and lead to osteoarthritis.  相似文献   

6.
After total hip arthroplasty, impingement of implant components may occur during every-day patient activities causing increased shear stresses at the acetabular implant-bone interface. In the literature, impingement related lever-out moments were noted for a number of acetabular components. But there is little information about pelvic load transfer. The aim of the current study was to measure the three-dimensional strain distribution at the macrostructured hemispherical interface and in the periphery of a standard acetabular press-fit cup in an experimental implant-bone substitute model. An experimental setup was developed to simulate impingement loading via a lever arm representing the femoral component and the lower limb. In one experimental setup 12 strain gauges were embedded at predefined positions in the periphery of the acetabular cup implant inside a tray, using polyurethane composite resin as a bone substitute material. By incremental rotation of the implant tray in steps of 10 and 30 deg, respectively, the strains were measured at evenly distributed positions. With the described method 288 genuine strain values were measured in the periphery of an embedded acetabular cup implant in one experimental setup. In two additional setups the strains were evaluated at different distances from the implant interface. Both in radial and meridional interface directions strain magnitudes reach their peak near the rim of the cup below the impingement site. Values of equatorial strains vary near zero and reach their peaks near the rim of the cup on either side and in some distance from the impingement site. Interestingly, the maximum of averaged radial strains does not occur, as expected, close to the interface but at an interface offset of 5.6 mm. With the described experimental setup it is now possible to measure and display the three-dimensional strain distribution in the interface and the periphery of an embedded acetabular cup implant. The current study provides the first experimental proof of the high local stresses gradients in the direct vicinity of the impingement site. The results of the current study help for a better understanding of the impingement mechanism and its impact on acetabular cup stability.  相似文献   

7.
In this study, a hemi-pelvis of composite sawbone was implanted with a Charnley cup using a conventional bone cement and the acetabular replacement was tested under constant amplitude cyclic loads, simulating the maximum hip contact force during normal walking. The damage development in the reconstruction was detected and monitored using CT scanning at regular test intervals, verified by microscopy post testing. Three identical experimental results showed that extensive debonding at the bone-cement interface occurred around the dome region after 20 million cycles.  相似文献   

8.
A Strain energy density (SED) criterion based on a fracture mechanics approach was used to assess the possible failure of acetabular bone cement after total hip replacement. Stress distributions in the cement at the bone-cement interface were calculated using two-dimensional finite element analyses. The results indicate that increasing the thickness of bone cement reduces the risk of cement fracture. The addition of a metal backing to the polyethylene cup and retention of the subchondral bone further reduces the risk of failure. The SED criterion was found to predict the same critical regions as zones of possible cement failure as the von Mises' criterion. Although either criterion can be used for predicting failure in this acetabular analysis both criteria are excessively conservative in predicting failure in regions where high principal compressive stresses are present. Further development of cement failure criteria are indicated.  相似文献   

9.
The Dry Holocene Megathermal in Inner Mongolia   总被引:5,自引:0,他引:5  
The paleoclimate since 14 kyr BP (14C age) was reconstructed based on a 16.22-m-long sediment core collected from Lake Yanhaizi, a saline lake located near the northern limit of the East Asian summer monsoon in Inner Mongolia. Coarse sediments were deposited there during a shrinkage phase of the lake when sand dunes reactivated. These sediments have low organic carbon contents but high maturity indices, indicating that they were deposited in an arid environment. By contrast, based on high organic contents and low maturity indices, fine sediments were deposited during periods of high lake stand in a humid environment. It was in general dry between 8.0 and 4.3 kyr BP. The above dry and wet phases are consistent with those recovered from the arid-semiarid transition zone elsewhere, but are unlike the widely perceived humid Holocene Megathermal reported in east China and the newly reconstructed record in the alpine Retreat Lake in Taiwan. The discrepancy may be due to a relative insensitivity to humidity changes in these two areas since they have both been under the total influence of the summer monsoon. On the other hand, much enhanced evaporation over higher monsoon precipitation at Lake Yanhaizi reduces the effective humidity in the warm climate near the northern boundary of the summer monsoon. This also accounts for the fact the high-temperature Holocene Megathermal, as revealed in the Okinawa Trough and the northern South China Sea, is correlated to the dry phases at Lake Yanhaizi. Conversely, the 4-2-kyr BP coldest period in the Holocene corresponds to a wet phase at Lake Yanhaizi.  相似文献   

10.
This paper is concerned with the fracture mechanics of a bone-cement interface that includes a cohesive zone effect on the crack faces. This accounts for the experimentally observed strengthening mechanism due to the mechanical interlock between the crack faces. Edge crack models are developed where the cohesive zone is simulated by a continuous or a discrete distribution of linear or nonlinear springs. It is shown that the solution obtained by assuming a homogeneous material is fairly close to the exact solution for the bimaterial interface edge crack problem. On the basis of that approximation, the analysis is conducted for the problem of two interacting edge cracks, one at the interface, and the other one in the cement. The small crack that was observed to initiate in the cement, close to the bone-cement interface, does not affect much the mode I stress-intensity factor at the tip of the interface crack. However it may grow, leading to a catastrophic breakdown of the cement. The analysis and following discussion point out an interdependency between bone-cement interface strength and cement strength not previously appreciated. The suggested crack models provide a framework for quantifying the fracture mechanisms at the bone-cement interface.  相似文献   

11.
This paper gives an insight about compression and tension cracks as encountered at a bone-cement interface. Within the context of continuum theory of fracture, an analytical solution is presented for the problem of a bimaterial interface edge crack under uniaxial tension or compression, assuming no tangential slip along the crack faces since cement pedicles penetrate into the cancellous bone several millimeters. Also essential to the solution are cohesive zone effects that account for a strengthening mechanism over the crack faces. The solution provides a methodological framework for quantifying the influence of the cohesive zone on the magnitude of the stress singularity. Mode I crack tip stress intensity factors are calculated at different stages of the loading and unloading phases under uniaxial tension or compression. Finally, an inelastic mechanism is presented that gives theoretical support to explain the formation of interfacial compression cracks, a phenomenon that was not previously appreciated and that arises from the rigid cement being forced into the more compliant cancellous bone.  相似文献   

12.
Polyethylene wear after total hip arthroplasty may occur as a result of normal gait and as a result of subluxation and relocation with impact. Relocation of a subluxed hip may impart a moment to the cup creating sliding as well as compression at the cup liner interface. The purpose of the current study is to quantify, by a validated finite element model, the forces generated in a hip arthroplasty as a result of subluxation relocation and compare them to the forces generated during normal gait. The micromotion between the liner and acetabular shell was quantified by computing the sliding track and the deformation at several points of the interface. A finite element analysis of polyethylene liner stress and liner/cup micromotion in total hip arthroplasty was performed under two dynamic profiles. The first profile was a gait loading profile simulating the force vectors developed in the hip arthroplasty during normal gait. The second profile is generated during subluxation and subsequent relocation of the femoral head. The forces generated by subluxation relocation of a total hip arthroplasty can exceed those forces generated during normal gait. The induced micromotion at the cup polyethylene interface as a result of subluxation can exceed micromotion as a result of the normal gait cycle. This may play a significant role in the generation of backsided wear. Minimizing joint subluxation by restoring balance to the hip joint after arthroplasty should be explored as a strategy to minimize backsided wear.  相似文献   

13.
Svensjö T  Pomahac B  Yao F  Slama J  Eriksson E 《Plastic and reconstructive surgery》2000,106(3):602-12; discussion 613-4
Full-thickness skin wounds are preferably allowed to heal under controlled hydration dressings such as hydrocolloids. It was hypothesized that a wet (liquid) environment rather than a dry or moist one would accelerate the wound healing process. We compared skin repair by secondary intention in full-thickness skin wounds in wet (saline), moist (hydrocolloid), and dry (gauze) conditions in an established porcine wound healing model. The study included three animals with a total of 70 wounds layered in a standardized fashion on the back of young Yorkshire pigs. Twelve days after wounding, 0 percent of dry, 20 percent of moist, and 86 percent of saline-treated wounds were completely reepithelialized (p values = 0.0046 and 0.027 for saline wounds compared with dry and moist wounds, respectively). The accelerated healing was caused at least in part by faster contraction in wet wounds (p value < 0.005 compared with that of other groups 9 and 12 days after wounding). Development of granulation tissue was faster in moist conditions than it was for dry and wet wounds. The thickness and number of cell layers of the newly formed epidermis were greater in dry and wet wounds than in moist ones. It was concluded that these full-thickness porcine skin wounds healed faster in a wet environment than in a moist one. Dry wounds healed more slowly than moist wounds. The basic mechanisms of skin wound repair were influenced by the treatment modality as demonstrated by the observed differences in granulation tissue formation, reepithelialization, and rate of wound contraction.  相似文献   

14.
The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35–50° and 10–25°, respectively, and 12 cases with different hip centre heights within a range of 0–15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants.  相似文献   

15.
Pre-clinical testing of hip endoprostheses is a mandatory requirement before clinical release. Inadequate loading conditions may lead to lower elastic and plastic interface movements than those occurring post-operatively in vivo. This study investigated the influence of patient activity on the primary stability of cementless prostheses with a special emphasis on active simulation of muscle forces. A loading setup, based on validated musculo-skeletal analyses, was used to generate the hip contact force during walking and stair climbing by transmitting muscle forces through the femur. In addition, a loading configuration which only generated the hip contact force occurring during stair climbing at the prosthesis head was simulated. CLS prostheses were implanted in 18 composite femora and subjected to cyclical loading. The relative micro-movements at the bone-prosthesis interface were determined and appeared to be extremely sensitive to the specific patient activity. Compared to walking, stair climbing generated higher micro-movements, with pronounced axial and rotational components. Stair climbing with the femur loaded by the resultant hip contact force only exhibited a characteristic valgus tilt of the stem with significantly lower interface micro-movements than under active simulation of muscle forces. The analyses suggest that stair climbing induced the highest mechanical instability at the bone-prosthesis interface, a level which may compromise the necessary osseointegration process. Active simulation of muscle forces considerably affects the primary stability of cementless hip endoprostheses. Pre-clinical in vitro tests should therefore simulate stair climbing and include muscle activity in the assessment of initial implant stability, otherwise micro-movements may be underestimated and the primary stability overestimated.  相似文献   

16.
Late loosening of cemented acetabular cups is increasingly being recognized as a clinical problem. One of the factors which may contribute to loosening is high localized deformation and stress at the cement-bone interface, the magnitude of which depends on the size of the total hip replacement (THR) femoral head. The effects of varying the femoral head size, from 22 to 32 mm, on strain values measured on the surface of the cup were investigated using experimental stress analysis techniques. The largest absolute strains were recorded when loading with the 22 mm head size. Peak strain values decreased to a minimum with the 26 mm head size and increased steadily with head sizes beyond 26 mm. The selection of an acetabular cup size and corresponding femoral head size in a total hip arthroplasty should not be an arbitrary one, but should be based on scientific studies which indicate minimum states of stress within the cup and cement mantle, as well as clinical evidence that the combination of components shows a reduced incidence of failure. This study experimentally quantifies the states of stress on the surface of the acetabular cup and points to the possible existence of an optimum component size to minimize surface stress.  相似文献   

17.
Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface.  相似文献   

18.
目的建立人体髋臼骨结核三维有限元模型,探讨不同部位髋臼骨结核软骨下骨塌陷的风险。方法通过正常髋关节CT数据,利用Mimics软件和ANSYS有限元软件,建立正常髋关节三维有限元模型(模型A)、髋臼顶部骨结核(模型B)、髋臼中心部骨结核(模型C)、髋臼前部骨结核(模型D)、髋臼后部骨结核(模型E)三维有限元模型,模拟人体单脚站立进行加载,分析髋臼软骨下骨峰值Von Mises应力和初始微动值。结果建立了正常髋关节和不同部位髋臼骨结核三维有限元模型,各模型含节点269284,三维四面体单元184786个。通过加载分析结果显示:与正常髋关节相比,峰值Von Mises应力,依次增加84%、3%、21%、67%;髋臼软骨下骨初始微动值依次增加66%、11%、17%、29%。结论髋臼顶部结核软骨下骨峰值Von Mises应力和初始微动值最大,塌陷的风险最大。  相似文献   

19.
The relatively high incidence of labral tears among patients presenting with hip pain suggests that the acetabular labrum is often subjected to injurious loading in vivo. However, it is unclear whether the labrum participates in load transfer across the joint during activities of daily living. This study examined the role of the acetabular labrum in load transfer for hips with normal acetabular geometry and acetabular dysplasia using subject-specific finite element analysis. Models were generated from volumetric CT data and analyzed with and without the labrum during activities of daily living. The labrum in the dysplastic model supported 4-11% of the total load transferred across the joint, while the labrum in the normal model supported only 1-2% of the total load. Despite the increased load transferred to the acetabular cartilage in simulations without the labrum, there were minimal differences in cartilage contact stresses. This was because the load supported by the cartilage correlated with the cartilage contact area. A higher percentage of load was transferred to the labrum in the dysplastic model because the femoral head achieved equilibrium near the lateral edge of the acetabulum. The results of this study suggest that the labrum plays a larger role in load transfer and joint stability in hips with acetabular dysplasia than in hips with normal acetabular geometry.  相似文献   

20.
A number of different animal models have been employed by investigators to study the biology of the bone-cement interface as it relates to the problem of hip implant loosening in humans. This study compares to the human three species (baboon, dog, and sheep) currently under use as experimental animal models from an anatomical point of view. A number of parameters, important for the dimensional design of a femoral prosthesis, loads at the hip joint and its subsequent performance, were used for comparing external and internal femoral anatomy. The baboon and dog femora were found to be most similar to the human femur in their external anatomy. The quantification of cancellous bone distribution within the medullary canal revealed that, of the species studied, the sheep femur provided the least support to the prosthesis. The results suggest that the dog and baboon are anatomically appropriate for studying hip implant biomechanics experimentally. Thus, from an anatomical point of view, the current extensive use of the dog as an experimental animal appears appropriate.  相似文献   