1.
BACKGROUND: Flow cytometers, which are commercially available, do not necessarily meet all demands of actual biomedical research. This is the case for the investigation of mechanisms involved in cell volume regulation, which requires electrical volume measurement and ratiometric multichannel fluorescence analysis for the simultaneous assessment of different physiologic parameters (intracellular pH and the intracellular concentration of calcium ions, etc). METHODS AND RESULTS: We describe the construction of a new nonsorting flow cytometer designed for the simultaneous acquisition of seven parameters including fluorescence signals, forward and perpendicular light scatter, cell volume according to the electrical Coulter principle, and flow cytometric imaging. The instrument is equipped with three different light sources. A tunable argon-ion laser generates efficient excitation of the most standard fluorescent probes in the visible spectral range, and an arc lamp provides the means for ultraviolet excitation at low cost. Because of the spatial filtering by the excitation and detection optics, two independent sets of dual fluorescence measurements can be performed, a prerequisite for flexible ratiometric fluorescence analysis. A flow video microscope integrated into the optical system optionally generates either brightfield or phase images of selected flowing particles. Only particles whose individual datasets meet predefined gating conditions are imaged in real time. To avoid smear effects, the motion of the object to be imaged (speed approximately 8 m/s) is frozen on the target of a CCD camera by flash illumination. For this purpose, a high radiance gas discharge lamp with 25-mJ electric pulse energy provides an illumination time of 18 ns (full width half maximum). Test results obtained from latex spheres and cells are shown. CONCLUSIONS: Test results indicate that our instrument can perform Coulter measurements in combination with flexible optical analysis. Moreover, integration of an adapted video microscope into a flow cytometer is an approach to overcome the gap between flow and image cytometry.  相似文献   

2.
Multiple wavelength operation in a flow cytometer is an exciting way for cell analysis based on both fluorescence and optical scattering processing. For example, this multiparametric technique is currently used to differentiate blood cells subpopulations. The choice of excitation wavelengths matching fluorochrome spectra (it is currently the opposite) and the use of a broader range of fluorochromes can be made by taking advantage of a filtered supercontinuum white light source. In this study, we first wished to validate the use of a specific triggered supercontinuum laser in a flow cytometer based on white light scattering and electric sizing on human blood cells. Subsequently, to show the various advantages of this attractive system, using scattering effect, electrical detections, and fluorescence analysis, we realized cells sorting based on DNA/RNA stained by thiazole orange. Discrimination of white blood cells is efficiently demonstrated by using a triggered supercontinuum-based flow cytometer operating in a "one cell-one shot" configuration. The discriminated leukocyte populations are monocytes, lymphocytes, granulocytes, immature granulocytes, and cells having a high RNA content (monoblasts, lymphoblasts, and plasma cells). To the best of our knowledge, these results constitute the first practical demonstration of flow cytometry based on triggered supercontinuum illumination. This study is the starting point of a series of new experiments fully exploiting the spectral features of such a laser source. For example, the large flexibility in the choice of the excitation wavelength allows to use a larger number of fluorochromes and to excite them more efficiently. Moreover, this work opens up new research directions in the biophotonics field, such as the combination of coherent Raman spectroscopy and flow cytometry techniques.  相似文献   

3.
The calibration of a flow cytometer against a microphotometer, to allow the correlation of cell morphology with fluorescence intensity, is described. Using three human lymphoblastoid cell lines, the photomultiplier amplification of the microphotometer and the flow cytometer that gave optimum linearity between fluorescence intensity and DNA content for the two instruments was established. Thereafter, at these settings, there was satisfactory linear agreement between the fluorescence intensity profiles, as measured by the flow cytometer and the microphotometer, of stained cell populations. Day-to-day variation was also minimal, and it was demonstrated that the application of this procedure can provide an alternative to the employment of the sorting facility of a flow cytometer for the morphologic identification of cell subpopulations during flow cytometric analysis.  相似文献   

4.
Fluorescence is a mainstay of bioanalytical methods, offering sensitive and quantitative reporting, often in multiplexed or multiparameter assays. Perhaps the best example of the latter is flow cytometry, where instruments equipped with multiple lasers and detectors allow measurement of 15 or more different fluorophores simultaneously, but increases beyond this number are limited by the relatively broad emission spectra. Surface enhanced Raman scattering (SERS) from metal nanoparticles can produce signal intensities that rival fluorescence, but with narrower spectral features that allow a greater degree of multiplexing. We are developing nanoparticle SERS tags as well as Raman flow cytometers for multiparameter single cell analysis of suspension or adherent cells. SERS tags are based on plasmonically active nanoparticles (gold nanorods) whose plasmon resonance can be tuned to give optimal SERS signals at a desired excitation wavelength. Raman resonant compounds are adsorbed on the nanoparticles to confer a unique spectral fingerprint on each SERS tag, which are then encapsulated in a polymer coating for conjugation to antibodies or other targeting molecules. Raman flow cytometry employs a high resolution spectral flow cytometer capable of measuring the complete SERS spectra, as well as conventional flow cytometry measurements, from thousands of individual cells per minute. Automated spectral unmixing algorithms extract the contributions of each SERS tag from each cell to generate high content, multiparameter single cell population data. SERS-based cytometry is a powerful complement to conventional fluorescence-based cytometry. The narrow spectral features of the SERS signal enables more distinct probes to be measured in a smaller region of the optical spectrum with a single laser and detector, allowing for higher levels of multiplexing and multiparameter analysis.  相似文献   

5.
Analysis of phytoplankton by flow cytometry   总被引:3,自引:0,他引:3  
Optical properties of eight algae species were measured on a flow cytometer. Forward and perpendicular light scatter measurements provide information on the size and shape of algae cells. The intensity of chlorophyll fluorescence varies greatly among the studied algae species and can be used to distinguish them. Measurements of chlorophyll fluorescence after excitation with different wavelengths provide a fluorescence excitation spectrum for each species over the available wavelength range. These spectra reflect the different photosynthetic pigment contents of the species. Staining algae cells with the DNA stains, Hoechst 33342 and DAPI, provides two additional optical parameters to distinguish algae populations: blue nuclear fluorescence and yellow granular fluorescence. The combination of these optical measurements enables the distinction of each algae species into a small cluster in a hyperspace of parameters. The automation of phytoplankton analysis on the flow cytometer may lead to the rapid and objective assessment of water quality.  相似文献   

6.
BACKGROUND: Flow cytometric fluorescence resonance energy transfer (FCET) is an efficient method to map associations between biomolecules because of its high sensitivity to changes in molecular distances in the range of 1-10 nm. However, the requirement for a dual-laser instrument and the need for a relatively high signal-to-noise system (i.e., high expression level of the molecules) pose limitations to a wide application of the method. METHODS: Antibodies conjugated to cyanines 3 and 5 (Cy3 and Cy5) were used to label membrane proteins on the cell surface. FCET measurements were made on a widely used benchtop dual-laser flow cytometer, the FACSCalibur, by using cell-by-cell analysis of energy transfer efficiency.ResultsTo increase the accuracy of FCET measurements, we applied a long wavelength donor-acceptor pair, Cy3 and Cy5, which beneficially affected the signal-to-noise ratio in comparison with the classic pair of fluorescein and rhodamine. A new algorithm for cell-by-cell correction of autofluorescence further improved the sensitivity of the technique; cell subpopulations with only slightly different FCET efficiencies could be identified. The new FCET technique was tested on various direct and indirect immunofluorescent labeling strategies. The highest FCET values could be measured when applying direct labeling on both (donor and acceptor) sides. Upon increasing the complexity of the labeling scheme by introducing secondary antibodies, we detected a decrease in the energy transfer efficiency. CONCLUSIONS: We developed a new FCET protocol by applying long wavelength excitation and detection of fluorescence and by refining autofluorescence correction. The increased accuracy of the new method makes cells with low receptor expression amenable to FCET investigation, and the new approach can be implemented easily on a commercially available dual-laser flow cytometer, such as a FACSCalibur.  相似文献   

7.
BACKGROUND: The ImageStream system combines advances in CCD technologies with a novel optical architecture for high sensitivity and multispectral imaging of cells in flow. The sensitivity and dynamic range as well as a methodology for spectral compensation of imagery is presented. METHODS: Multicolored fluorescent beads were run on the ImageStream and a flow cytometer. Four single color fluorescent control samples of cells were run to quantify spectral overlap. An additional sample, labeled with all colors was run and compensated in six spectral channels. RESULTS: Analysis of empirical data for sensitivity and dynamic range matched theoretical predictions. The ImageStream system demonstrated fluorescence sensitivity comparable to a PMT-based flow cytometer. A methodology for addressing spectral overlap, individual pixel anomalies, and multiple imaging modalities was demonstrated for spectral compensation of K562 cells. Imagery is shown pre- and post-compensation. CONCLUSIONS: Unlike intensity measurements made with conventional flow cytometers, object size impacts both dynamic range and fluorescence sensitivity in systems that utilize pixilated detection. Simultaneous imaging of alternate modalities can be employed to increase fluorescent sensitivity. Effective compensation of complex multimode imagery spanning six spectral bands is accomplished in a semi-automated manner.  相似文献   

8.
Change in fluorescence polarization of intracellular fluorescein measured with a specially adapted flow cytometer reliably reflected subtle biophysical changes in cells, such as those accompanying increased temperature or osmolality of the suspending medium. This system was developed to monitor changes in lymphocytes one hour after stimulation with the mitogen phytohaemagglutinin, and provided a sensitive and rapid assay of lymphocyte activation.  相似文献   

9.
We have investigated changes that occur in mitochondria obtained from the livers of rats that had been maintained on a high protein diet (80% casein instead of 20%) for 6 months. Liver homogenates were separated by centrifugation into a mitochondrial fraction, a nuclear fraction and the supernatant fluid of the nuclear fraction (nuclear wash). Rhodamine-123 was used to selectively stain mitochondria depending upon their membrane potential. The stained organelles were processed through a flow cytometer where the fluorescent stains were excited by the 488 nm wavelength of a laser and the resultant fluorescence signals analysed. After 6 months on a high protein diet, mitochondria displayed an increase in the fluorescence associated with rhodamine-123 uptake in both mitochondrial and nuclear wash fractions, while mitochondrial fluorescence in the nuclear fraction showed a heterogeneous distribution. This was interpreted as an increase in membrane potential in most of the liver mitochondria under these nutritional conditions, with a certain degree of heterogeneity. These functional changes may be correlated with morphological alterations previously reported and show the usefulness of flow cytometry for biochemical analysis of isolated mitochondria.  相似文献   

10.
A method has been developed for the determination of the efficiency (E) of the fluorescence resonance energy transfer between moieties on cell surfaces by use of a computer-controlled flow cytometer capable of dual wavelength excitation. The absolute value of E may be calculated on a single-cell basis. The analysis requires the measurement of samples stained with donor and acceptor conjugated ligands alone as well as together. In model experiments HK 22 murine lymphoma cells labeled with fluorescein-conjugated concanavalin A (Con A) and/or rhodamine conjugated Con A were used to determine energy transfer histograms. Using the analytic solution to energy transfer in two dimensions, a high surface density of Con A binding sites was found that suggests that the Con A receptor sites on the cell surface are to a degree preclustered . We call this technique flow cytometric energy transfer ( FCET ).  相似文献   

11.
C S Owen 《Cell calcium》1991,12(6):385-393
In the theory of measurement of calcium ion activity by determination of Fura-2 fluorescence at two excitation wavelengths, the accuracy of the result depends upon the accuracy both of the sample measurements and of the calibration measurements which are made on calcium-bound and free dye. Two factors underlie adequate calibration and accuracy. The first is the elimination of systematic error due to spectral shifts arising from the intracellular environment felt by the dye. To this end, detailed comparisons between complete spectra of both calcium-bound and calcium-free Fura-2 can be used to help separate spectral effects due to light absorption by cellular constituents versus polarity and viscosity of the intracellular milieu. The second major factor which determines accuracy is the experimental uncertainty (in both sample and calibration measurements). For samples in which the ratio of bound to free dye is large, the uncertainty in the ratio is also large, even when it is expressed as a percentage of the ratio itself. The errors in calibration measurements impact on the accuracy of the method primarily through the measurements made at wavelengths which are off the spectral peaks of the bound or free dye, since these are the least accurate. In order to obtain a guide to the choice of wavelengths and estimation of the reliability of results, a mathematical expression is derived for the dependence of the accuracy of the method on the accuracy of both sample and calibration measurements.  相似文献   

12.
We provide a protocol for a high-resolution flow cytometry-based method for quantitative and qualitative analysis of individual nano-sized vesicles released by cells, as developed and previously described by our group. The method involves (i) bright fluorescent labeling of cell-derived vesicles and (ii) flow cytometric analysis of these vesicles using an optimized configuration of the commercially available BD Influx flow cytometer. The method allows the detection and analysis of fluorescent cell-derived vesicles of ~100 nm. Integrated information can be obtained regarding the light scattering, quantity, buoyant density and surface proteins of these nano-sized vesicles. This method can be applied in nanobiology to study basic aspects of cell-derived vesicles. Potential clinical applications include the detailed analysis of vesicle-based biomarkers in body fluids and quality control analysis of (biological) vesicles used as therapeutic agents. Isolation, fluorescent labeling and purification of vesicles can be done within 24 h. Flow cytometer setup, calibration and subsequent data acquisition can be done within 2-4 h by an experienced flow cytometer operator.  相似文献   

13.
The new, fluorescent Ca2+ indicator, fura-2, promises to expand our understanding of the role of subcellular changes in Ca2+ underlying cell function. During an investigation of the role of Ca2+ in the polarization response of human polymorphonuclear leukocytes to formyl-methionyl-leucyl-phenylalanine, we found that fura-2 trapped by cells incubated with the acetoxy-methyl ester of fura-2, F2-AM, yielded measurements of Ca2+ that were depressed at rest and during the response to formyl-methionyl-leucyl-phenylalanine. Fura-2, trapped by the cells, exhibited a spectrum in the presence of saturating Ca2+ that differed from that of fura-2 free acid. We have shown that the cellular fluorescence can be spectrally decomposed into two components: one with Ca2+ sensitivity identical to fully deesterified fura-2, and another which is Ca2+-insensitive. The Ca2+-insensitive component appears to be more fluorescent than F2-AM as well as spectrally different from F2-AM. The insensitive form probably results from incomplete deesterification of F2-AM by the cells. In order to accurately measure Ca2+ in polymorphonuclear leukocytes, it is imperative to check for the presence of Ca2+-insensitive fluorescence. The contribution of Ca2+-insensitive fura-2 fluorescence can be assessed routinely from spectral data obtained by calibration of intracellular fura-2 with known [Ca2+] using ionomycin. The end-of-experiment calibration step not only ensures accurate [Ca2+] measurements in polymorphonuclear leukocytes and in other cell types that display Ca2+-insensitive, contaminating fluorescence but also yields the spectral characteristics of the insensitive species.  相似文献   

14.
C van Oven  J A Aten 《Cytometry》1990,11(5):630-635
An instrument is described which analyses shapes of fluorescence profiles generated by particles passing through the focussed laser beam of a flow cytometer. The output signal of this pulse-shape analyzer is used as input for the signal processing electronics of a commercial flow cytometer system. The instrument detects dips in pulse-profiles; a shape parameter named Pulse Dip Index (PDI) is defined as the ratio of the integrated signal from the beginning of the pulse until the first dip, relative to the integrated signal of the complete profile. This PDI is similar to the Centromeric Index of chromosomes. The composition of aggregates in mixtures of fluorescent particles of different sizes was evaluated by PDI analysis. In our experiments the PDI was determined within 30 microseconds from the onset of the pulse-profile and particles with a specified morphology of interest were selected for on-line registration of their profiles as digitized pulse-shapes. In a cell sorter system, the PDI can be used as a parameter for sorting.  相似文献   

15.
Global analysis using trilinear curve resolution is described and shown to be a powerful method for the resolution of polarized fluorescence data arrays, in which the measured fluorescence intensity is a separable function of polarization orientation, excitation wavelength, and emission wavelength. This methodology is applicable to mixtures the components of which have linearly independent excitation and emission spectra and distinct anisotropies. Normalized excitation and emission spectra of individual components can be uniquely determined without prior assumptions concerning spectral shapes (e.g., sum of Gaussians) and without the uncertainties inherent in bilinear techniques such as principal component analysis or factor analysis. The normalized excitation and emission vectors are combined with the total absorption spectrum of the multicomponent mixture to compute absolute absorption and emission spectra. The precision of this methodology is evaluated as a function of noise, overlap, relative intensity, and anisotropy difference between components using simulated mixtures of the DNA bases. The ability of this method to extract individual spectra from steady-state fluorescence data arrays is illustrated for mixtures containing two and three components.  相似文献   

16.
Despite recent progress in cell-analysis technology, rapid classification of cells remains a very difficult task. Among the techniques available, flow cytometry (FCM) is considered especially powerful, because it is able to perform multiparametric analyses of single biological particles at a high flow rate-up to several thousand particles per second. Moreover, FCM is nondestructive, and flow cytometric analysis can be performed on live cells. The current limit for simultaneously detectable fluorescence signals in FCM is around 8-15 depending upon the instrument. Obtaining multiparametric measurements is a very complex task, and the necessity for fluorescence spectral overlap compensation creates a number of additional difficulties to solve. Further, to obtain well-separated single spectral bands a very complex set of optical filters is required. This study describes the key components and principles involved in building a next-generation flow cytometer based on a 32-channel PMT array detector, a phase-volume holographic grating, and a fast electronic board. The system is capable of full-spectral data collection and spectral analysis at the single-cell level. As demonstrated using fluorescent microspheres and lymphocytes labeled with a cocktail of antibodies (CD45/FITC, CD4/PE, CD8/ECD, and CD3/Cy5), the presented technology is able to simultaneously collect 32 narrow bands of fluorescence from single particles flowing across the laser beam in <5 μs. These 32 discrete values provide a proxy of the full fluorescence emission spectrum for each single particle (cell). Advanced statistical analysis has then been performed to separate the various clusters of lymphocytes. The average spectrum computed for each cluster has been used to characterize the corresponding combination of antibodies, and thus identify the various lymphocytes subsets. The powerful data-collection capabilities of this flow cytometer open up significant opportunities for advanced analytical approaches, including spectral unmixing and unsupervised or supervised classification.  相似文献   

17.
H B Steen 《Cytometry》1992,13(8):822-830
The sensitivity and resolution of flow cytometers are functions of the signal produced by a given particle as well as by the noise in the presence of which the signal is detected. The noise is primarily due to the fact that emission of light as well as its detection by photoelectric devises are stochastic processes. This fact leads to equations describing how resolution and sensitivity are limited by the magnitude of the signal, the background, and the photoelectron quantum yield of the detector. The equations are pointing to a method by which the signal and noise of a flow cytometer can be measured in absolute terms, as well as a way to determine fluorescence sensitivity without having to extrapolate to the noise level. The equations appear to be validated when applied to measuring data obtained with two different flow cytometers.  相似文献   

18.
A high throughput method for screening of protein expression is described. By using a flow cytometer, levels of both soluble and precipitated protein can simultaneously be assessed in vivo. Protein fragments were fused to the N-terminus of enhanced GFP and the cell samples were analysed using a flow cytometer. Data concerning whole cell fluorescence and light scattering was collected. The whole cell fluorescence is probing intracellular concentrations of soluble fusion proteins. Concurrently, forward scattered light gives data about inclusion body formation, valuable information in process optimisation. To evaluate the method, the cells were disrupted, separated into soluble and non-soluble fractions and analysed by gel electrophoresis. A clear correlation between fluorescence and soluble target protein was shown. Interestingly, the distribution of the cells regarding forward scatter (standard deviation) correlates with the amount of inclusion bodies formed. Finally, the newly developed method was used to evaluate two different purification tags, His(6) and Z(basic), and their effect on the expression pattern.  相似文献   

19.
Techniques for correction of fluorescence emission and excitationspectra of phytoplankton are described, which can be appliedin any commercially available spectrophotometer. The correctionof the emission spectrum is based on the measurement of a calibratedlight source. The excitation spectra are corrected by meansof a quantum counter solution that measures the spectral intensityof the excitation system and separate correction for wavelength-dependenteffects of the excitation optics. The correction proceduresgive technically corrected spectra, i.e. spectra that are freefrom wavelength dependent bias, but do not give absolute intensityvalues. Spectra that have been properly corrected for instrumentalwavelength dependencies are suitable for intercomparison, bothintra- and interlaboratory. Another application is the derivationof spectral data that will be obtained by other techniques thatmake use of fluorescence measurements, such as flow cytometry,remote sensing and in situ instruments. A necessary conditionis that the spectral response functions of these instrumentsmust be known. 1Present address: AKZO, Arla-CRL, PO Box 9300, NL-6800 SB Arnhem,The Netherlands  相似文献   

20.
流式细胞术是一种采用激光束激发单行流动的细胞,对它的散射光和携带的荧光进行探测,从而完成细胞分析和分选的技术。以流式细胞术为核心技术,流式细胞仪集光学、电子学、生物学、免疫学等多门学科和技术于一体,能够高效分析微小颗粒(如细胞,细菌)的先进科技设备。它对社会产生了深远的影响,成为了科学研究的必要工具。最近几年,流式细胞仪取得了长足进步。为了深入的了解它,本文从流式细胞仪的工作原理和技术指标,在临床医学、生物学、生殖学和制药学中的应用,以及它的世界格局、仪器功能的最新进展三方面,进行了简明、扼要的论述。展望未来:功能专业化、自动化,体积小型化,多色多参数分析能力提高和分析分选速度更快成为流式细胞仪发展的趋势。  相似文献   