首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study investigates the separate and combined effects of IGF-1 and mechanical loads on chondrocytes in elderly human femoral head articular cartilage. Full depth biopsies of articular cartilage were subjected to either no load, static or cyclic (2 s on/2 s off) loading in unconfined compression at a stress of 1 MPa for 48 h with or without IGF-1 (300 ng ml(-1)). Chondrocyte biosynthetic activity was measured using 35S-sulphate and 3H-leucine during the last 24 h of loading. IGF-1 alone increased the rates of isotope incorporation, by 80% for 35S-SO4 and 40% for 3H-leucine, whereas loading alone reduced matrix biosynthesis. Applying load (cyclic or static) in the presence of IGF-1 returned the incorporation rates to their unstimulated levels. This study suggests elderly human articular cartilage is responsive to stimulation by IGF-1 but mechanical factors seem to act sufficiently strongly in the opposite direction to cancel this response.  相似文献   

2.
Chondrocytes within articular cartilage experience complete unloading between loading cycles thereby utilizing mechanical signals to regulate their own anabolic and catabolic activities. Structural alterations of proteoglycans (PGs) during aging and the development of osteoarthritis (OA) have been reported; whether these can be attributed to altered load or compression is largely unknown. We report here on experiments in which the effect of intermittent loading on the fine structure of newly synthesized chondroitin sulfate (CS) in bovine articular cartilage explants was examined. Tissues were subjected for 6 days to cyclic compressive pressure using a sinusoidal waveform of 0.1, 0.5 or 1.0 Hz frequency with a peak stress of 0.5 MPa for a period of 5, 10 or 20 s, followed by an unloading period lasting 10, 100 or 1000 s. During the final 18 h of the culture, cartilage explants were radiolabeled with 50 microCi/ml D-6-[3H]glucosamine, and newly synthesized as well as endogenous CS chains were isolated after proteinase solubilization of the tissue. CS chains were depolymerized with chondroitinase ABC and ACII, and the 3H-digestion products were quantified after fractionation by high-performance anion-exchange chromatography using a CarboPac PA1 column. Intermittently applied cyclic mechanical loading did not affect the proportion of 4- and 6-sulfated disaccharide repeats, but caused a significant decrease in the abundance of the 4,6-disulfated nonreducing terminal galNAc residues. In addition, loading induced elongation of CS chains. Taken together, these data provide evidence for the first time that long-term in vitro loading results in marked and reproducible changes in the fine structure of newly synthesized CS, and that accumulation of such chains may in turn modify the physicochemical and biological response of articular cartilage. Moreover, data presented here suggest that in vitro dynamic compression of cartilage tissue can induce some of the same alterations in CS sulfation that have previously been shown to occur during the development of degenerative joint diseases such as OA.  相似文献   

3.
M Wong  M Siegrist  X Cao 《Matrix biology》1999,18(4):391-399
In this study, we investigated the biosynthetic response of full thickness, adult bovine articular cartilage explants to 45 h of static and cyclic unconfined compression. The cyclic compression of articular cartilage resulted in a progressive consolidation of the cartilage matrix. The oscillatory loading increased protein synthesis ([35S]methionine incorporation) by as much as 50% above free swelling control values, but had an inhibitory influence on proteoglycan synthesis ([35SO4] incorporation). As expected, static compression was associated with a dose-dependent decrease in biosynthetic activity. ECM oligomeric proteins which were most affected by mechanical loading were fibronectin and cartilage oligomeric matrix protein (COMP). Static compression at all amplitudes caused a significant increase in fibronectin synthesis over free swelling control levels. Cyclic compression of articular cartilage at 0.1 Hz and higher was consistently associated with a dramatic increase in the synthesis of COMP as well as fibronectin. The biosynthetic activity of chondrocytes appears to be sensitive to both the frequency and amplitude of the applied load. The results of this study support the hypothesis that cartilage tissue can remodel its extracellular matrix in response to alterations in functional demand.  相似文献   

4.
The biomechanical response of articular cartilage to a wide range of impact loading rates was investigated for stress magnitudes that exist during joint trauma. Viable, intact bovine cartilage explants were impacted in confined compression with stress rates of 25, 50, 130 and 1000 MPa/s and stress magnitudes of 10, 20, 30 and 40 MPa. Water loss, cell viability, dynamic impact modulus (DIM) and matrix deformation were measured. Under all loading conditions the water loss was small (approximately 15%); water loss increased linearly with increasing peak stress and decreased exponentially with increasing stress rate. Cell death was localized within the superficial zone (< or =12% of total tissue thickness); the depth of cell death from the articular surface increased with peak stress and decreased with increasing stress rate. The DIM increased (200-700 MPa) and matrix deformation decreased with increasing stress rate. Initial water and proteoglycan (PG) content had a weak, yet significant influence on water loss, cell death and DIM. However, the significance of the inhomogeneous structure and composition of the cartilage matrix was accentuated when explants impacted on the deep zone had less water loss and matrix deformation, higher DIM, and no cell death compared to explants impacted on the articular surface. The mechano-biological response of articular cartilage depended on magnitude and rate of impact loading.  相似文献   

5.
Macroscopic structural damage to the cartilage articular surface can occur due to slicing in surgery, cracking in mechanical trauma, or fibrillation in early stage osteoarthrosis. These alterations may render cartilage matrix and chondrocytes susceptible to subsequent mechanical injury and contribute to progression of degenerative disease. To examine this hypothesis, single 300 microm deep vertical slices were introduced across a diameter of the articular surface of osteochondral explant disks on day 6 after dissection. Then a single uniaxial unconfined ramp compression at 7 x 10(-5) or 7 x 10(-2) s(-1) strain rate to a peak stress of 3.5 or 14 MPa was applied on day 13 during which mechanical behavior was monitored. Effects of slices alone and together with compression were measured in terms of explant swelling and cell viability on days 10 and 17. Slicing alone induced tissue swelling without significant cell death, while compression alone induced cell death without significant tissue swelling. Under low strain rate loading, no differences in the response to injurious compression were found between sliced and unsliced explants. Under high strain rate loading, slicing rendered cartilage more easily compressible and appeared to slightly reduce compression-induced cell and matrix injury. Findings highlight microphysical factors important to cartilage mechanical injury, and suggest ways that macroscopic structural damage may accelerate or, in certain cases, possibly slow the progression of cartilage degeneration.  相似文献   

6.
Experimental evidence indicates that the biosynthetic activity of chondrocytes is associated with the mechanical environment. For example, excessive, repetitive loading has been found to induce cell death, morphological and cellular damage, as seen in degenerative joint disease, while cyclic, physiological-like loading has been found to trigger a partial recovery of morphological and ultrastructural aspects in osteoarthritic human articular chondrocytes. Mechanical stimuli are believed to influence the biosynthetic activity via the deformation of cells. However, the in situ deformation of chondrocytes for cyclic loading conditions has not been investigated experimentally or theoretically. The purpose of the present study was to simulate the mechanical response of chondrocytes to cyclic loading in unconfined compression tests using a finite element model. The material properties of chondrocytes and extracellular matrix were considered to be biphasic. The time-histories of the shape and volume variations of chondrocytes at three locations (i.e., surface, center, and bottom) within the cartilage were predicted for static and cyclic loading conditions at two frequencies (0.02 and 0.1 Hz) and two amplitudes (0.1 and 0.2 MPa). Our results show that cells at different depths within the cartilage deform differently during cyclic loading, and that the depth dependence of cell deformation is influenced by the amplitude of the cyclic loading. Cell deformations under cyclic loading of 0.02 Hz were found to be similar to those at 0.1 Hz. We conclude from the simulation results that, in homogeneous cartilage layers, cell deformations are location-dependent, and further are affected by load magnitude. In physiological conditions, the mechanical environment of cells are even more complex due to the anisotropy, depth-dependent inhomogeneity, and tension-compression non-linearity of the cartilage matrix. Therefore, it is feasible to speculate that biosynthetic responses of chondrocytes to cyclic loading depend on cell location and load magnitude.  相似文献   

7.
The boundary lubrication function of articular cartilage is mediated in part by molecules at the articular surface and in synovial fluid, encoded by Prg4. The objective of this study was to determine whether static and dynamic compression regulate PRG4 biosynthesis by cartilage explants. Articular cartilage disks were harvested to include the articular surface from immature bovines. Some disks were subjected to 24 h (day 1) of loading, followed by 72 h (days 2-4) of free-swelling culture to assess chondrocyte responses following unloading. Loading consisted of 6 or 100 kPa of static compression, with or without superimposed dynamic compression (10 or 300 kPa peak amplitude, 0.01 Hz). Other disks were cultured free-swelling as controls. PRG4 secretion into culture medium was inhibited by all compression protocols during day 1. Following unloading, cartilage previously subjected to dynamic compression to 300 kPa exhibited a rebound effect, secreting more PRG4 than did controls, while cartilage previously subjected to 100 kPa static loading secreted less PRG4. Immunohistochemistry revealed that all compression protocols also affected the number of cells expressing PRG4. The paradigm that mechanical stimuli regulate biosynthesis in cartilage appears operative not only for load bearing matrix constituents, but also for PRG4 molecules mediating lubrication.  相似文献   

8.
《Biorheology》1996,33(4-5):289-304
To study the effect of dynamic mechanical force on cartilage metabolism, many investigators have applied a cyclic compressive load to cartilage disc explants in vitro. The most frequently used in vitro testing protocol has been the cyclic unconfined compression of articular cartilage in a bath of culture medium. Cyclic compression has been achieved by applying either a prescribed cyclic displacement or a prescribed cyclic force on a loading platen placed on the top surface of a cylindrical cartilage disc. It was found that the separation of the loading platen from the tissue surface was likely when a prescribed cyclic displacement was applied at a high frequency.The purpose of the present study was to simulate mathematically the dynamic behavior of a cylindrical cartilage disc subjected to cyclic unconfined compression under a dynamic force boundary condition protocol, and to provide a parametric analysis of mechanical deformations within the extracellular matrix. The frequency-dependent dynamic characteristics of dilatation, hydrostatic pressure and interstitial fluid velocity were analyzed over a wide range of loading frequencies without the separation of the loading platen. The result predicted that a cyclic compressive force created an oscillating positive-negative hydrostatic pressure together with a forced circulation of interstitial fluid within the tissue matrix. It was also found that the load partitioning mechanism between the solid and fluid phases was a function of loading frequency. At a relatively high loading frequency, a localized dynamic zone was developed near the peripheral free surface of the cartilage disc, where a large dynamic pressure gradient exists, causing vigorous interstitial fluid flow.  相似文献   

9.
Articular cartilage in vivo experiences the effects of both cell-regulatory proteins and mechanical forces. This study has addressed the hypothesis that the frequency of intermittently or continuously applied mechanical loads is a critical parameter in the regulation of chondrocyte collagen biosynthesis. Cyclic compressive pressure was applied intermittently to bovine articular cartilage explants by using a sinusoidal waveform of 0.1–1.0 Hz frequency with a peak stress of 0.5 MPa for a period of 5–20 s followed by a load-free period of 10–1,000 s. These loading protocols were repeated for a total duration of 6 days. In separate experiments, cyclic loading was continuously applied by using a sinusoidal waveform of 0.001–0.5 Hz frequency and a peak stress of 1.0 MPa for a period of 3 days. Unloaded cartilage discs of the same condyle were cultured in identically constructed loading chambers and served as controls. We report quantitative data showing that (1) no correlation exists between the relative rate of collagen synthesis expressed as the proportion of newly synthesized collagen among newly made proteins and either the frequency of intermittently or continuously applied loads or the overall time cartilage is actively loaded, and (2) individual protocols of intermittently applied loads can reduce the relative rate of collagen synthesis and increase the water content, whereas (3) continuously applied cyclic loads always suppress the relative rate of collagen synthesis compared with that of unloaded control specimens. The results provide further experimental evidence that collagen metabolism is difficult to manipulate by mechanical stimuli. This is physiologically important for the maintainance of the material properties of collagen in view of the heavy mechanical demands made upon it. Moreover, the unaltered or reduced collagen synthesis of cartilage explants might reflect more closely the metabolism of normal or early human osteoarthritic cartilage.This work was supported by the Federal Ministry of Education and Research (BMBF no. 0311058) and by the foundation S.E.T.  相似文献   

10.
This study analyzes the molecular response of articular chondrocytes to short-term mechanical loading with a special focus on gene expression of molecules relevant for matrix turnover. Porcine cartilage explants were exposed to static and dynamic unconfined compression and viability of chondrocytes was assessed to define physiologic loading conditions. Cell death in the superficial layer correlated with mechanical loading and occurred at peak stresses >or=6 MPa and a cartilage compression above 45%. Chondrocytes in native cartilage matrix responded to dynamic loading by rapid and highly specific suppression of collagen expression. mRNA levels dropped 11-fold (collagen 2; 6 MPa, P=0.009) or 14-fold (collagen 1; 3 and 6 MPa, P=0.009) while levels of aggrecan, tenascin-c, matrix metalloproteinases (MMP1, 3, 13, 14), and their inhibitors (TIMP1-3) did not change significantly. Thus, dynamic mechanical loading rapidly shifted the balance between collagen and aggrecan/tenascin/MMP/TIMP expression. A better knowledge of the chondrocyte response to mechanical stress may improve our understanding of mechanically induced osteoarthrits.  相似文献   

11.
Morel V  Quinn TM 《Biorheology》2004,41(3-4):509-519
The short-term responses of articular cartilage to mechanical injury have important implications for prevention and treatment of degenerative disease. Cell and matrix responses were monitored for 11 days following injurious compression of cartilage in osteochondral explants. Injury was applied as a single ramp compression to 14 MPa peak stress at one of three strain rates: 7 x 10(-1), 7 x 10(-3) or 7 x 10(-5) s(-1). Responses were quantified in terms of the appearance of macroscopic matrix cracks, changes in cell viability, and changes in cartilage wet weights. Loading at the highest strain rate resulted in acute cell death near the superficial zone in association with cracks, followed over the 11 days after compression by a gradual increase in cell death and loss of demarcation between matrix zones containing viable versus nonviable cells. In contrast, loading at the lowest strain rate resulted in more severe, nearly full-depth cell death acutely, but with no apparent worsening over the 11 days following compression. Between days 4 and 11, all mechanically injured explants significantly increased in wet weight, suggesting loss of matrix mechanical integrity independent of compression strain rate. Results demonstrate that short-term responses of cartilage depend upon the biomechanical characteristics of injurious loading, and suggest multiple independent pathways of mechanically-induced cell death and matrix degradation. Modifications to an existing fiber-reinforced poroelastic finite element model were introduced and the model was used for data interpretation and identification of microphysical events involved in cell and matrix injury. The model performed reasonably well at the slower strain rates and exhibited some capacity for anticipating the formation of superficial cracks during injurious loading. However, several improvements appear to be necessary before such a model could reliably be used to draw upon in vitro experimental results for prediction of injurious loading situations in vivo.  相似文献   

12.
Articular cartilage is an enduring tissue. For most individuals, articular cartilage facilitates a lifetime of pain-free ambulation, supporting millions of loading cycles from activities of daily living. Although early studies into osteoarthritis focused on the role of mechanical fatigue in articular cartilage degeneration, much is still unknown regarding its strength and endurance characteristics. The compressive strength of juvenile, bovine articular cartilage explants was determined to be loading rate-dependent, reaching a maximum strength of 29.5 ± 4.8 MPa at a strain rate of 0.10 %/sec. The fatigue and endurance properties of articular cartilage were characterized utilizing a material testing system, as well as a custom, validated instrument termed the two degrees-of-freedom endurance meter (endurometer). These instruments characterized fatigue in articular cartilage explants at loading levels ranging from 10 to 80 % strength (%S), up to 100,000 cycles. Cartilage explants displayed characteristics of fatigue – fatigue life increased as the loading magnitude decreased. All explants failed within 14,000 cycles at loading levels between 50 and 80 %S. At 10 and 20 %S, all explants endured 100,000 loading cycles. There was no significant difference in equilibrium compressive modulus between run-out explants and unloaded controls, although the pooled modulus increased in response to testing. Histological staining and biochemical assays revealed no material changes in collagen, sulfated glycosaminoglycan, or hydration content between unloaded controls and explants cyclically loaded to run-out. These results suggest articular cartilage may have a putative endurance limit of 20 %S (5.86 MPa), with implications for articular cartilage biomechanics and mechanobiology.  相似文献   

13.
Excessive mechanical loading can lead to matrix damage and chondrocyte death in articular cartilage. Previous studies on chondral and osteochondral explants have not clearly distinguished to what extent the degree and the distribution of cell death are dependent on the presence of an underlying layer of bone. The current study hypothesized that the presence of underlying bone would decrease the amount of matrix damage and cell death. Chondral and osteochondral explants were loaded to 30 MPa at a high rate of loading (approximately 600 MPa/s) or at a low rate of loading (30 MPa/s). After 24 hours in culture, matrix damage was assessed by the total length and average depth of surface fissures. The explants were also sectioned and stained for cell viability in the various layers of the cartilage. More matrix damage was documented in chondral than osteochondral explants for each rate of loading experiment. The total amount of cell death was also less in osteochondral explants than chondral explants. The presence of underlying bone significantly reduced the extent of cell death in all zones in low rate of loading tests. The percentage of cell death was also reduced in the intermediate zone and deep zones of the explant by the presence of the underlying bone for a high rate of loading. This study indicated that the presence of underlying bone significantly limited the degree of matrix damage and cell death, and also affected the distribution of dead cells through the explant thickness. These data may have relevance to the applicability of experimental data from chondral explants to the in situ condition.  相似文献   

14.
Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the cartilage in both the underformed and deformed states. The objectives of the work reported in this article were to 1) design an apparatus that could apply highly repeatable cyclic compressive loads of 400 N and operate in the bore of an MRI scanner, 2) demonstrate that the apparatus and MRI scanner can be successfully integrated to observe 3D deformations in a phantom material, 3) use the apparatus to determine the load cycle necessary to achieve a steady-state deformation response in normal bovine articular cartilage samples using a flat-surfaced and nonporous indentor in unconfined compression. Composed of electronic and pneumatic components, the apparatus regulated pressure to a double-acting pneumatic cylinder so that (1) load-controlled compression cycles were applied to cartilage samples immersed in a saline bath, (2) loading and recovery periods within a cycle varied in time duration, and (3) load magnitude varied so that the stress applied to cartilage samples was within typical physiological ranges. In addition the apparatus allowed gating for MR image acquisition, and operation within the bore of an MRI scanner without creating image artifacts. The apparatus demonstrated high repeatability in load application with a standard deviation of 1.8% of the mean 400 N load applied. When the apparatus was integrated with an MRI scanner programmed with appropriate pulse sequences, images of a phantom material in both the underformed and deformed states were constructed by assembling data acquired through multiple signal acquisitions. Additionally, the number of cycles to reach a steady-state response in normal bovine articular cartilage was 49 for a total cycle duration of 5 seconds, but decreased to 33 and 27 for increasing total cycle durations of 10 and 15 seconds, respectively. Once the steady-state response was achieved, 95% of all displacements were within +/- 7.42 microns of the mean displacement, indicating that the displacement response to the cyclic loads was highly repeatable. With this performance, the MRI-loading apparatus system meets the requirements to create images of articular cartilage from which 3D deformation can be determined.  相似文献   

15.
Loading of articular cartilage during weight bearing is essential for the maintenance of cartilage function. Although certain cyclic loading protocols stimulate extracellular matrix synthesis, constant or static compression decreases proteoglycan and collagen synthesis in cartilage explants. The goal of this study was to determine whether the compression-induced decrease in proteoglycan synthesis involves an interleukin-1 (IL-1) signaling pathway. Cartilage explants were compressed 50% in the presence of IL-1 receptor antagonist (IL-1ra), and the incorporation of [35S]sulfate into macromolecules was measured. IL-1ra increased sulfate incorporation in compressed cartilage but not in cartilage maintained at the in situ thickness (0% compression). IL-1alpha and IL-1beta mRNAs were detected in cartilage compressed 50% for at least 3h, while nitric oxide synthase II mRNA was only detected in cartilage compressed 50% for 6h. The data support a role for the IL-1 receptor in the pathway linking static compression to reduced proteoglycan synthesis.  相似文献   

16.
Solute transport through the extracellular matrix is essential for cellular activities in articular cartilage. Increased solute transport via fluid convection may be a mechanism by which dynamic compression stimulates chondrocyte metabolism. However, loading conditions that optimally augment transport likely vary for different solutes. To investigate effects of dynamic loading on transport of a bioactive solute, triangular mechanical loading waveforms were applied to cartilage explants disks while interstitial transport of a fluorescent glucose analog was monitored. Peak-to-peak compression amplitudes varied from 5-50% and frequencies varied from 0.0006-0.1 Hz to alter the spatial distribution and magnitude of oscillatory fluid flow. Solute transport was quantified by monitoring accumulation of fluorescence in a saline bath circulated around the explant. Individual explants were subjected to a series of compression protocols, so that effects of loading on solute desorption could be observed directly. Maximum increases in solute transport were obtained with 10-20% compression amplitudes at 0.1 Hz; similar loading protocols were previously found to stimulate chondrocyte metabolism in vitro. Results therefore support hypotheses relating to increased solute transport as a mediator of the cartilage biological response to dynamic compression, and may have application in mechanical conditioning of cartilage constructs for tissue engineering.  相似文献   

17.
18.
A bovine cartilage explant system was used to evaluate the effects of injurious compression on chondrocyte apoptosis and matrix biochemical and biomechanical properties within intact cartilage. Disks of newborn bovine articular cartilage were compressed in vitro to various peak stress levels and chondrocyte apoptotic cell death, tissue biomechanical properties, tissue swelling, glycosaminoglycan loss, and nitrite levels were quantified. Chondrocyte apoptosis occurred at peak stresses as low as 4.5 MPa and increased with peak stress in a dose-dependent manner. This increase in apoptosis was maximal by 24 h after the termination of the loading protocol. At high peak stresses (>20 MPa), greater than 50% of cells apoptosed. When measured in uniaxial confined compression, the equilibrium and dynamic stiffness of explants decreased with the severity of injurious load, although this trend was not significant until 24-MPa peak stress. In contrast, the equilibrium and dynamic stiffness measured in radially unconfined compression decreased significantly after injurious stresses of 12 and 7 MPa, respectively. Together, these results suggested that injurious compression caused a degradation of the collagen fibril network in the 7- to 12-MPa range. Consistent with this hypothesis, injurious compression caused a dose-dependent increase in tissue swelling, significant by 13-MPa peak stress. Glycosaminoglycans were also released from the cartilage in a dose-dependent manner, significant by 6- to 13-MPa peak stress. Nitrite levels were significantly increased above controls at 20-MPa peak stress. Together, these data suggest that injurious compression can stimulate cell death as well as a range of biomechanical and biochemical alterations to the matrix and, possibly, chondrocyte nitric oxide expression. Interestingly, chondrocyte programmed cell death appears to take place at stresses lower than those required to stimulate cartilage matrix degradation and biomechanical changes. While chondrocyte apoptosis may therefore be one of the earliest responses to tissue injury, it is currently unclear whether this initial cellular response subsequently drives cartilage matrix degradation and changes in the biomechanical properties of the tissue.  相似文献   

19.
The deformational behavior of articular cartilage has been investigated in confined and unconfined compression experiments and indentation tests, but to date there exist no reliable data on the in situ deformation of the cartilage during static loading. The objective of the current study was to perform a systematic study into cartilage compression of intact human femoro-patellar joints under short- and long-term static loading with MR imaging. A non-metallic pneumatic pressure device was used to apply loads of 150% body weight to six joints within the extremity coil of an MRI scanner. The cartilage was delineated during the compression experiment with previously validated 2D and 3D fat-suppressed gradient echo sequences. We observed a mean (maximal) in situ deformation of 44% (57%) in patellar cartilage after 32 h of loading (mean contact pressure 3.6 MPa), the femoral cartilage showing a smaller amount of deformation than the patella. However, only around 7% of the final deformation (3% absolute deformation) occurred during the first minute of loading. A 43% fluid loss from the interstitial patellar matrix was recorded, the initial fluid flux being 0.217 +/- 0.083 microm/s, and a high inter-individual variability of the deformational behavior (coefficients of variation 11-38%). In conjunction with finite-element analyses, these data may be used to compute the load partitioning between the solid matrix and fluid phase, and to elucidate the etiologic factors relevant in mechanically induced osteoarthritis. They can also provide direct estimates of the mechanical strain to be encountered by cartilage transplants.  相似文献   

20.
Osteoarthritis is a severe socio-economical disease, for which a suitable treatment modality does not exist. Tissue engineering of cartilage transplants is the most promising method to treat focal cartilage defects. However, current culturing procedures do not yet meet the requirements for clinical implementation. This article presents a novel bioreactor device for the functional tissue engineering of articular cartilage which enables cyclic mechanical loading combined with medium perfusion over long periods of time, under controlled cultivation and stimulation conditions whilst ensuring system sterility. The closed bioreactor consists of a small, perfused, autoclavable, twin chamber culture device with a contactless actuator for mechanical loading. Uni-axial loading is guided by externally applied magnetic fields with real-time feedback-control from a platform load cell and an inductive proximity sensor. This precise measurement allows the development of the mechanical properties of the cultured tissue to be monitored in real-time. This is an essential step towards clinical implementation, as it allows accounting for differences in the culture procedure induced by patient-variability. This article describes, based on standard agarose hydrogels of 3 mm height and 10 mm diameter, the technical concept, implementation, scalability, reproducibility, precision, and the calibration procedures of the whole bioreactor instrument. Particular attention is given to the contactless loading system by which chondrocyte scaffolds can be compressed at defined loading frequencies and magnitudes, whilst maintaining an aseptic cultivation procedure. In a "proof of principle" experiment, chondrocyte seeded agarose gels were cultured for 21 days in the bioreactor system. Intermittent medium perfusion at a steady flow rate (0.5 mL/min) was applied. Sterility and cell viability (ds-DNA quantification and fluorometric live/dead staining) were preserved in the system. Flow induced shear stress stimulated sGAG (sulfated glycosaminoglycan) content (DMMB assay) after 21 days, which was confirmed by histological staining of Alcian blue and by immunostaining of Aggrecan. Experimental data on mechanotransduction and long-term studies on the beneficial effects of combined perfusion and different mechanical loading patterns on chondrocyte seeded scaffolds will be published separately.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号