首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hip endoprosthesis for in vivo measurement of joint force and temperature.   总被引:2,自引:0,他引:2  
Friction between the prosthetic head and acetabular cup increases the temperature in hip implants during activities like walking. A hip endoprosthesis was instrumented with sensors to measure the joint contact forces and the temperature distribution along the entire length of the titanium implant. Sensors and two inductively powered telemetry units are placed inside the hip implant and hermetically sealed against body fluids. Each telemetry unit contains an integrated 8-channel telemetry chip and a radio frequency transmitter. Force, temperature and power supply data are transmitted at different frequencies by two antennas to an external twin receiver. The inductive power supply is controlled by a personal computer. Force and temperature are monitored in real time and all data are stored on a video tape together with the patient's images. This paper describes the design and accuracy of the instrumented implant and the principal function of the external system components.  相似文献   

2.
Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with respect to the underlying bones. A non-invasive dual fluoroscopic imaging system (DFIS) based tracking technique has been used to avoid skin artifacts and provide accurate 6-DOF kinematic measurement. This study aimed to quantify in-vivo 6-DOF THA kinematics during gait using DFIS. Twenty eight well-functioning THAs were evaluated during treadmill gait under DFIS surveillance. The maximum translations of the femoral head were 0.46±0.10 mm and 0.45±0.10 mm during the stance and swing phases (p=0.57), respectively. The range of hip flexion was from 8.7° to 47.6°, adduction from 3.0° to 12.5° and external rotation from 19.2° to 29.7°. The THA was flexed, externally rotated and adducted throughout the gait. The magnitudes of the femoral head translations were found to be within the manufacture tolerance of the components, suggesting that in-vivo hip “pistoning” during gait cycle may be minimal in well-functioning THAs. The 6-DOF kinematics could be used as the baseline knowledge for further improvement of wear-testing of hip implant, implants manufacturing and implant positioning during surgery.  相似文献   

3.
The long-term loosening of artificial hip joints remains a serious clinical problem. Optimization of implant design and material will improve the fixation, but it requires a detailed knowledge of the forces which act on the implant. A four-channel telemetric transmitter was developed and arranged completely inside a hermetically closed artificial hip joint. This permits long term in vivo measurements of the three-dimensional forces without endangering the patient. The external telemetry system consists of an inductive power supply, an RF receiver, a microcomputer with hardware extension and a VHS video system. The personal computer offers real-time data processing of three orthogonal force components as well as slow motion analysis of recorded measurements. After several years of animal tests, two instrumented prostheses were implanted in the first patient (male) in May and August of 1988. In March 1990 a third prosthesis was implanted in a second patient (female). Joint force measurements have regularly been performed from the first post-operative day until now for several kinds of activity.  相似文献   

4.
The rising prevalence of osteoarthritis and an increase in total hip replacements calls for attention to potential therapeutic activities. Cycling is considered as a low impact exercise for the hip joint and hence recommended. However, there are limited data about hip joint loading to support this claim. The aim of this study was to measure synchronously the in vivo hip joint loads and pedal forces during cycling. The in vivo hip joint loads were measured in 5 patients with instrumented hip implants. Data were collected at several combinations of power and cadence, at two saddle heights.Joint loads and pedal forces showed strong linear correlation with power. So the relationship between the external pedal forces and internal joint forces was shown. While cycling at different cadences the minimum joint loads were acquired at 60 RPM. The lower saddle height configuration results in an approximately 15% increase compared to normal saddle height.The results offered new insights into the actual effects of cycling on the hip joint and can serve as useful tools while developing an optimum cycling regimen for individuals with coxarthrosis or following total hip arthroplasty. Due to the relatively low contact forces, cycling at a moderate power level of 90 W at a normal saddle height is suitable for patients.  相似文献   

5.
In the past decade, there have been exciting developments in the field of lithium ion batteries as energy storage devices, resulting in the application of lithium ion batteries in areas ranging from small portable electric devices to large power systems such as hybrid electric vehicles. However, the maximum energy density of current lithium ion batteries having topatactic chemistry is not sufficient to meet the demands of new markets in such areas as electric vehicles. Therefore, new electrochemical systems with higher energy densities are being sought, and metal‐air batteries with conversion chemistry are considered a promising candidate. More recently, promising electrochemical performance has driven much research interest in Li‐air and Zn‐air batteries. This review provides an overview of the fundamentals and recent progress in the area of Li‐air and Zn‐air batteries, with the aim of providing a better understanding of the new electrochemical systems.  相似文献   

6.
In the past decade, there have been exciting developments in the field of lithium ion batteries as energy storage devices, resulting in the application of lithium ion batteries in areas ranging from small portable electric devices to large power systems such as hybrid electric vehicles. However, the maximum energy density of current lithium ion batteries having topatactic chemistry is not sufficient to meet the demands of new markets in such areas as electric vehicles. Therefore, new electrochemical systems with higher energy densities are being sought, and metal‐air batteries with conversion chemistry are considered a promising candidate. More recently, promising electrochemical performance has driven much research interest in Li‐air and Zn‐air batteries. This review provides an overview of the fundamentals and recent progress in the area of Li‐air and Zn‐air batteries, with the aim of providing a better understanding of the new electrochemical systems.  相似文献   

7.
Soldiers are fielded with a variety of equipment including battery powered electronic devices. An energy harvesting assault pack (EHAP) was developed to provide a power source to recharge batteries and reduce the quantity and load of extra batteries carried into the field. Little is known about the biomechanical implications of carrying a suspended-load energy harvesting system compared to the military standard assault pack (AP). Therefore, the goal of this study was to determine the impact of pack type and load magnitude on spatiotemporal and kinematic parameters while walking at 1.34 m/s on an instrumented treadmill at decline, level, and incline grades. There was greater forward trunk lean while carrying the EHAP and the heavy load (decline: p < 0.001; level: p = 0.009; incline: p = 0.003). As load increased from light to heavy, double support stance time was longer (decline: p = 0.012; level: p < 0.001; incline: p < 0.001), strides were shorter (incline: p = 0.013), and knee flexion angle at heel strike was greater (decline: p = 0.033; level: p = 0.035; incline: p = 0.005). When carrying the EHAP, strides (decline: p = 0.007) and double support stance time (incline: p = 0.006) was longer, the knee was more flexed at heel strike (level: p = 0.014; incline: p < 0.001) and there was a smaller change in knee flexion during weight acceptance (decline: p = 0.0013; level: p = 0.007; incline: p = 0.0014). Carrying the EHAP elicits changes to gait biomechanics compared to carrying the standard AP. Understanding how load-suspension systems influence loaded gait biomechanics are warranted before transitioning these systems into military or recreational environments.  相似文献   

8.
Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.  相似文献   

9.
The molecular machinery of life relies on complex multistep processes that involve numerous individual transitions, such as molecular association and dissociation steps, chemical reactions, and mechanical movements. The corresponding transition rates can be typically measured in vitro but not in vivo. Here, we develop a general method to deduce the in-vivo rates from their in-vitro values. The method has two basic components. First, we introduce the kinetic distance, a new concept by which we can quantitatively compare the kinetics of a multistep process in different environments. The kinetic distance depends logarithmically on the transition rates and can be interpreted in terms of the underlying free energy barriers. Second, we minimize the kinetic distance between the in-vitro and the in-vivo process, imposing the constraint that the deduced rates reproduce a known global property such as the overall in-vivo speed. In order to demonstrate the predictive power of our method, we apply it to protein synthesis by ribosomes, a key process of gene expression. We describe the latter process by a codon-specific Markov model with three reaction pathways, corresponding to the initial binding of cognate, near-cognate, and non-cognate tRNA, for which we determine all individual transition rates in vitro. We then predict the in-vivo rates by the constrained minimization procedure and validate these rates by three independent sets of in-vivo data, obtained for codon-dependent translation speeds, codon-specific translation dynamics, and missense error frequencies. In all cases, we find good agreement between theory and experiment without adjusting any fit parameter. The deduced in-vivo rates lead to smaller error frequencies than the known in-vitro rates, primarily by an improved initial selection of tRNA. The method introduced here is relatively simple from a computational point of view and can be applied to any biomolecular process, for which we have detailed information about the in-vitro kinetics.  相似文献   

10.
The development of wearable electronics and sensing networks has increased the demand for wearable power modules that have steady output, high energy density, and long cycle life. Current power modules, such as batteries, suffer from low energy density due to their limited storage capacity. One solution to avoid the issue is to build a hybrid device consisting of both energy harvesting elements that continuously harvest ambient mechanical energy, and electrochemical energy storage units to store the harvested energy. Here, a hybrid energy harvesting bracelet, which combines a dual electromagnetic and triboelectric nanogenerator to harvest wrist motions, is reported. The bracelet is able to charge the RuO2‐based microsupercapacitor to 2 V with a single shake of human wrist, which allows the supercapacitor to power most electronic devices for minutes, such as a calculator, relative humidity, and temperature sensors.  相似文献   

11.
When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2-10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants.  相似文献   

12.
The prospective of using direct‐write printing techniques for the manufacture of organic photovoltaics (OPVs) has made these techniques highly attractive. OPVs have the potential to revolutionize small‐scale portable electronic applications by directly providing electric power to the systems. However, no route is available for monolithically integrating the energy‐harvesting units into a system in which other components, such as transistors, sensors, or displays, are already fabricated. Here, the fabrication and the measurement of inkjet‐printed, air‐processed organic solar cells is reported for the first time. Highly controlled conducting and semiconducting films using engineered inks for inkjet printing enable good efficiencies for printed OPVs between ≈2 and 5% power conversion efficiency. The results show that inkjet printing is an attractive digital printing technology for cost‐effective, environmentally friendly integration of photovoltaic cells onto plastic substrates.  相似文献   

13.
The currently commercialized lithium‐ion batteries have allowed for the creation of practical electric vehicles, simultaneously satisfying many stringent milestones in energy density, lifetime, safety, power, and cost requirements of the electric vehicle economy. The next wave of consumer electric vehicles is just around the corner. Although widely adopted in the vehicle market, lithium‐ion batteries still require further development to sustain their dominating roles among competitors. In this review, the authors survey the state‐of‐the‐art active electrode materials and cell chemistries for automotive batteries. The performance, production, and cost are included. The advances and challenges in the lithium‐ion battery economy from the material design to the cell and the battery packs fitting the rapid developing automotive market are discussed in detail. Also, new technologies of promising battery chemistries are comprehensively evaluated for their potential to satisfy the targets of future electric vehicles.  相似文献   

14.
Gait modifications in acetabular dysplasia patients may influence cartilage contact stress patterns within the hip joint, with serious implications for clinical outcomes and the risk of developing osteoarthritis. The objective of this study was to understand how the gait pattern used to load computational models of dysplastic hips influences computed joint mechanics. Three-dimensional pre- and post-operative hip models of thirty patients previously treated for hip dysplasia with periacetabular osteotomy (PAO) were developed for performing discrete element analysis (DEA). Using DEA, contact stress patterns were calculated for each pre- and post-operative hip model when loaded with an instrumented total hip, a dysplastic, a matched control, and a normal gait pattern. DEA models loaded with the dysplastic and matched control gait patterns had significantly higher (p = 0.012 and p < 0.001) average pre-operative maximum contact stress than models loaded with the normal gait. Models loaded with the dysplastic and matched control gait patterns had nearly significantly higher (p = 0.051) and significantly higher (p = 0.008) average pre-operative contact stress, respectively, than models loaded with the instrumented hip gait. Following PAO, the average maximum contact stress for DEA models loaded with the dysplastic and matched control patterns decreased, which was significantly different (p < 0.001) from observed increases in maximum contact stress calculated when utilizing the instrumented hip and normal gait patterns. The correlation between change in DEA-computed maximum contact stress and the change in radiographic measurements of lateral center-edge angle were greatest (R2 = 0.330) when utilizing the dysplastic gait pattern. These results indicate that utilizing a dysplastic gait pattern to load DEA models may be a crucial element to capturing contact stress patterns most representative of this patient population.  相似文献   

15.
Since the first report of using micromechanical cleavage method to produce graphene sheets in 2004, graphene/graphene‐based nanocomposites have attracted wide attention both for fundamental aspects as well as applications in advanced energy storage and conversion systems. In comparison to other materials, graphene‐based nanostructured materials have unique 2D structure, high electronic mobility, exceptional electronic and thermal conductivities, excellent optical transmittance, good mechanical strength, and ultrahigh surface area. Therefore, they are considered as attractive materials for hydrogen (H2) storage and high‐performance electrochemical energy storage devices, such as supercapacitors, rechargeable lithium (Li)‐ion batteries, Li–sulfur batteries, Li–air batteries, sodium (Na)‐ion batteries, Na–air batteries, zinc (Zn)–air batteries, and vanadium redox flow batteries (VRFB), etc., as they can improve the efficiency, capacity, gravimetric energy/power densities, and cycle life of these energy storage devices. In this article, recent progress reported on the synthesis and fabrication of graphene nanocomposite materials for applications in these aforementioned various energy storage systems is reviewed. Importantly, the prospects and future challenges in both scalable manufacturing and more energy storage‐related applications are discussed.  相似文献   

16.
The migration of zinc‐ion batteries from alkaline electrolyte to neutral or mild acidic electrolyte promotes research into their flexible applications. However, discharge voltage of many reported zinc‐ion batteries is far from satisfactory. On one hand, the battery voltage is substantially restricted by the narrow voltage window of aqueous electrolytes. On the other hand, many batteries yield a low‐voltage discharge plateau or show no plateau but capacitor‐like sloping discharge profiles. This impacts the battery's practicability for flexible electronics where stable and consistent high energy is needed. Herein, an aqueous zinc hybrid battery based on a highly concentrated dual‐ion electrolyte and a hierarchically structured lithium‐ion‐intercalative LiVPO4F cathode is developed. This hybrid battery delivers a flat and high‐voltage discharge plateau of nearly 1.9 V, ranking among the highest reported values for all aqueous zinc‐based batteries. The resultant high energy density of 235.6 Wh kg?1 at a power density of 320.8 W kg?1 also outperforms most reported zinc‐based batteries. A designed solid‐state and long‐lasting hydrogel electrolyte is subsequently applied in the fabrication of a flexible battery, which can be integrated into various flexible devices as powerful energy supply. The idea of designing such a hybrid battery offers a new strategy for developing high‐voltage and high‐energy aqueous energy storage systems.  相似文献   

17.
Stationary batteries are projected to play a role in the electricity system of Switzerland after 2030. By enabling the integration of surplus production from intermittent renewables, energy storage units displace electricity production from different sources and potentially create environmental benefits. Nevertheless, batteries can also cause substantial environmental impacts during their manufacturing process and through the extraction of raw materials. A prospective consequential life cycle assessment (LCA) of lithium metal polymer and lithium‐ion stationary batteries is undertaken to quantify potential environmental benefits and drawbacks. Projections are integrated into the LCA model: Energy scenarios are used to obtain marginal electricity supply mixes, and projections about the battery performances and the recycling process are sourced from the literature. The roles of key parameters and methodological choices in the results are systematically investigated. The results demonstrate that the displacement of marginal electricity sources determines the environmental implications of using batteries. In the reference scenario representing current policy, the displaced electricity mix is dominated by natural gas combined cycle units. In this scenario, the use of batteries generates environmental benefits in 12 of the 16 impact categories assessed. Nevertheless, there is a significant reduction in achievable environmental benefits when batteries are integrated into the power supply system in a low‐carbon scenario because the marginal electricity production, displaced using batteries, already has a reduced environmental impact. The direct impacts of batteries mainly originate from upstream manufacturing processes, which consume electricity and mining activities related to the extraction of materials such as copper and bauxite.  相似文献   

18.
王昶  魏美芹  姚海琳  左绿水 《生态学报》2016,36(22):7346-7353
废旧动力电池包中含有丰富的镍、钴、稀土等稀贵金属,其资源化利用是实现混合动力汽车(Hybrid Electrical Vehicle,简称HEV)全生命周期绿色化管理的重要内容之一。随着HEV的不断发展,动力电池包在未来几年将逐渐进入批量报废阶段,其资源化利用的环境效益成为值得关注的问题。鉴于此,以丰田混合动力汽车镍氢电池包为研究对象,利用GREET模型和LIME值法测算出,相比于原生矿开采,单位废旧镍氢电池包中稀贵金属资源化利用所产生的环境效益为1083元;根据报废周期,对我国市场上现存的HEV镍氢电池包的未来报废情况进行预测。结果表明,这些电池包将从2018年开始迎来报废,在2021年达到报废高峰,至2024年基本完成报废;预计其稀贵金属资源化利用的环境效益,可累计达9421万元。提出了加强废旧动力电池回收体系和资源化利用体系建设的政策建议。  相似文献   

19.
With the development of the Internet of Things (IoTs), widely distributed electronics in the environment require effective in situ energy harvesting technologies, which is made challenging by the unstable supply and severe conditions in some environments. In this work, a hybrid all‐in‐one power source (AoPS) is demonstrated for widely adaptive environmental energy harvesting. With a novel structure, the AoPS hybridizes high‐performance spherical triboelectric nanogenerators (TENGs) with solar cells, enabling the harvesting of most typical environmental energies from wind, rain drops, and sun light, for complementary supply. The spherical TENG units with a packaged structure can work robustly to collect energy from fluid. Nearly continuous direct current and a high average power of 5.63 mW can be obtained by four TENG units, which is further complemented by solar cells. Typical application scenarios are also demonstrated, achieving self‐powered soil moisture control, forest fire prevention and pipeline monitoring. The work realizes the concept of an environmental power source that can be deployed in the environment with high adaptability to make use of all kinds of surrounding energies for powering electronics in all‐weather conditions, providing a reliable foundation for the era of the IoTs.  相似文献   

20.
The global energy demand is increasing at the same time as fossil fuel resources are dwindling. Consequently, the search for alternative energy sources is a major topic worldwide. Solar energy is one of the most promising, effective and emission‐free energy sources. However, the energy has to be stored to compensate the fluctuating availability of the sun and the actual energy demand. Photo‐rechargeable electric energy storage systems may solve this problem by immediately storing the generated electricity. Different combinations of solar cells and storage devices are possible. High efficiencies can be achieved by the combination of dye‐sensitized solar cells (DSSC) and capacitors. However, other hybrid devices including DSSCs or organic photovoltaic systems and redox flow batteries, lithium ion batteries and metal air batteries are playing an increasing role in this research field. This Progress Report reviews the state of the art research of photo‐rechargeable batteries based on organic solar cells, as well as storage modules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号