首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Diamond films of different structures were deposited on quartz, WC-Co, and molybdenum substrates in a microwave plasma torch discharge in an argon-hydrogen-methane gas mixture in a sealed chamber at pressures close to atmospheric by using the chemical vapor deposition technique. Images of diamond polycrystal films and separate crystals, as well as results of Raman spectroscopy, are presented. The spectra of optical plasma radiation recorded during film deposition demonstrate the presence of intense Hα hydrogen and C2 radical bands known as Swan bands.  相似文献   

2.
A microwave plasma (2.45 GHz) was used for depositing single crystal diamond layers at the deposition rate up to 40 μm/h in hydrogen-methane mixtures on the substrates from natural and synthetic diamond with the (100) deposition surface and with the size up to 5 × 5 mm. The structure and the defect-impurity composition of the fabricated single crystals with the thickness up to 600 μm have been investigated using Raman spectroscopy, photoluminescence spectroscopy, cathode luminescence spectroscopy, and electron and optical microscopy. A high quality and purity of the diamond layers deposited from a plasma was confirmed.  相似文献   

3.
The structure of a discharge induced by a coaxial microwave plasmatron with a gas-supply channel in the inner electrode of a coaxial waveguide is investigated. A plasmatron with a power of up to 10 W operates at a frequency of 10 GHz. Depending on the operation regime, the discharge takes either a filament or torch form. A plasma filament arises at low flow rates of the working gas (argon) and occurs at the border of the potential core of the gas jet. A torch discharge occurs at high flow rates and has the form of a hollow cone. In both cases, the discharge arises in the potential core of the gas jet and does not spread beyond it. The distribution of the microwave field in the discharge plasma is determined.  相似文献   

4.
A novel method for visualization of the process of interaction of high-power energy fluxes with various surfaces is proposed. The possibility of the dynamic visualization of a surface covered with a ∼3-cm-thick plasma layer with a linear density of ∼1016 cm−2 is demonstrated experimentally. A scheme of intracavity shadowgraphy of phase objects with the use of a laser projection microscope is developed. Shadow images illustrating the development of the plasma torch of an erosion capillary discharge in air are presented.  相似文献   

5.
Results are presented from optical measurements of the atomic hydrogen density and the gas temperature in a reactor for depositing diamond films from the plasmas of pulsed and continuous microwave discharges at a fixed mean microwave power. The results obtained make it possible to explain the fact that the growth rate of diamond films in the plasma of a pulsed microwave discharge is larger than that in a continuous microwave discharge.  相似文献   

6.
The operating principle of a novel microwave plasma source—a linear microwave vibrator with a gap—is discussed. The source is placed on a microwave-transparent window of a chamber filled with a plasma-forming gas (argon or methane). The device operation is based on the combination of two resonances—geometric and plasma ones. The results of experimental tests of the source are presented. For a microwave frequency of 2.45 GHz, microwave power of ≤1 kW, and plasma-forming gas pressure in the range 5 × 10−2–10−1 Torr, the source is capable of filling the reactor volume with a plasma having an electron density of about 1012 cm−3 and electron temperature of a few electronvolts.  相似文献   

7.
X-ray detectors based on single crystal diamond film made via chemical vapor deposition were investigated to evaluate their performance under clinically relevant conditions for radiotherapy dosimetry. Studies focused on repeatability, dose rate dependence, tissue phantom ratios, output factors and beam profiling. Repeatability experiments revealed a temporary loss in sensitivity due to charge detrapping effects following irradiation, which was modeled to make corrections that improved short-term precision. Dose rate dependence was observed (Fowler fitting parameter Δ = 0.96 ± 0.2) using dose rates up to ~2 Gy min^?1. The detector statistically distinguished (n = 5, P < 0.05) between dose values separated by 7.7 × 10^?3 Gy (1 MU). Depth dose measurements from 1 to 15 cm and output factors using 3 × 3 to 10 × 10 cm^2 field sizes compared well with a Farmer ion chamber (<1.3% difference). Output factor measurements indicate encouraging results for fields sizes <4 × 4 cm^2. Off-axis measurements showed that perturbation of the beam could be reduced when the detector is used in the edge-on orientation due to its thin-film sandwich configuration and ~200 nm thick Ag contacts. This relatively inexpensive detector has potential to be used for routine dosimetry using conventional radiotherapy instrumentation.  相似文献   

8.
The review of the methods for obtaining the runaway electron beams in the gas discharge is performed. The new method is offered, using which the beam is first formed in a narrow gap (∼1 mm) between the cathode and the grid and then it is accelerated by the field of the plasma column of the anomalous self-sustained discharge in the main gap (10–20 mm long). The electron beams with an energy of about 10 keV and current density of 103 A/cm2 at a molecular nitrogen pressure of up to 100 Torr have been obtained experimentally. The results of research of the UV nitrogen laser with an excitation via runaway electron beam and radiation of energy of ∼1 mJ are given. The UV nitrogen laser generation with the energy of ∼1 mJ has been obtained by the runaway electron beams.  相似文献   

9.
Excitation of a microwave discharge at the end of a cylindrical electrode in nitrogen at a pressure of 1 Torr and incident powers of 60–140 W was investigated experimentally by using K-008 and K-011 video cameras and analyzing oscillograms of discharge emission. The times during which the discharge is established in the radial and axial directions are found to be on the order of 10−4 and 10−2 s, respectively. The results obtained are analyzed using one-dimensional simulations of a discharge in nitrogen in a quasistatic approximation. The kinetic scheme includes 50 processes involving electrons, ions, and excited molecules and atoms. The time evolution of the concentrations of molecular nitrogen in the N2(C 3II u ) and N2(B 3II g ) states, responsible for the recorded discharge emission, is compared with the experimental data.  相似文献   

10.
Gold nanoparticles-modified boron-doped diamond (AuNPs–BDD) electrodes, which were prepared with a self-assembly deposition of AuNPs at amine-terminated boron-doped diamond, were examined for voltammetric detection of neuraminidase (NA). The detection method was performed based on the difference of electrochemical responses of zanamivir at gold surface before and after the reaction with NA in phosphate buffer solution (PBS, pH 5.5). A linear calibration curve for zanamivir in 0.1 M PBS in the absence of NA was achieved in the concentration range of 1 × 10−6 to 1 × 10−5 M (R2 = 0.99) with an estimated limit of detection (LOD) of 2.29 × 10−6 M. Furthermore, using its reaction with 1.00 × 10−5 M zanamivir, a linear calibration curve of NA can be obtained in the concentration range of 0–12 mU (R2 = 0.99) with an estimated LOD of 0.12 mU. High reproducibility was shown with a relative standard deviation (RSD) of 1.14% (n = 30). These performances could be maintained when the detection was performed in mucin matrix. Comparison performed using gold-modified BDD (Au–BDD) electrodes suggested that the good performance of the detection method is due to the stability of the gold particles position at the BDD surface.  相似文献   

11.
PurposeThe aim of the present work was to evaluate small field size output factors (OFs) using the latest diamond detector commercially available, PTW-60019 microDiamond, over different CyberKnife systems. OFs were measured also by silicon detectors routinely used by each center, considered as reference.MethodsFive Italian CyberKnife centers performed OFs measurements for field sizes ranging from 5 to 60 mm, defined by fixed circular collimators (5 centers) and by Iris variable aperture collimator (4 centers). Setup conditions were: 80 cm source to detector distance, and 1.5 cm depth in water. To speed up measurements two diamond detectors were used and their equivalence was evaluated. MonteCarlo (MC) correction factors for silicon detectors were used for comparing the OF measurements.ResultsConsidering OFs values averaged over all centers, diamond data resulted lower than uncorrected silicon diode ones. The agreement between diamond and MC corrected silicon values was within 0.6% for all fixed circular collimators. Relative differences between microDiamond and MC corrected silicon diodes data for Iris collimator were lower than 1.0% for all apertures in the totality of centers. The two microDiamond detectors showed similar characteristics, in agreement with the technical specifications.ConclusionsExcellent agreement between microDiamond and MC corrected silicon diode detectors OFs was obtained for both collimation systems fixed cones and Iris, demonstrating the microDiamond could be a suitable detector for CyberKnife commissioning and routine checks. These results obtained in five centers suggest that for CyberKnife systems microDiamond can be used without corrections even at the smallest field size.  相似文献   

12.
Results from experimental studies of multipactor discharges on the surfaces of various dielectrics placed in a high-Q cylindrical microwave cavity excited at the TE013 mode in the X-band are presented. The thresholds for the onset and maintenance of a multipactor discharge on quartz, polycrystalline diamond, lithium fluoride, and Teflon surfaces possessing different roughness are determined. It is shown that, in such a resonance system, a steady multipactor discharge can operate without transition into the stage of microwave breakdown of the desorbed gas. It is found that, due to long-term action of the discharge, a thin carbon-containing film is deposited on the dielectric surface, which leads to an increase in the breakdown threshold.  相似文献   

13.
This movie shows how an atmospheric pressure plasma torch can be ignited by microwave power with no additional igniters. After ignition of the plasma, a stable and continuous operation of the plasma is possible and the plasma torch can be used for many different applications. On one hand, the hot (3,600 K gas temperature) plasma can be used for chemical processes and on the other hand the cold afterglow (temperatures down to almost RT) can be applied for surface processes. For example chemical syntheses are interesting volume processes. Here the microwave plasma torch can be used for the decomposition of waste gases which are harmful and contribute to the global warming but are needed as etching gases in growing industry sectors like the semiconductor branch. Another application is the dissociation of CO2. Surplus electrical energy from renewable energy sources can be used to dissociate CO2 to CO and O2. The CO can be further processed to gaseous or liquid higher hydrocarbons thereby providing chemical storage of the energy, synthetic fuels or platform chemicals for the chemical industry. Applications of the afterglow of the plasma torch are the treatment of surfaces to increase the adhesion of lacquer, glue or paint, and the sterilization or decontamination of different kind of surfaces. The movie will explain how to ignite the plasma solely by microwave power without any additional igniters, e.g., electric sparks. The microwave plasma torch is based on a combination of two resonators — a coaxial one which provides the ignition of the plasma and a cylindrical one which guarantees a continuous and stable operation of the plasma after ignition. The plasma can be operated in a long microwave transparent tube for volume processes or shaped by orifices for surface treatment purposes.  相似文献   

14.
Results are presented from experimental studies of the current-voltage characteristics and spatial and temporal parameters of the plasma in a high-current pulsed magnetron sputtering system with a 10-cm-diameter plane disk cathode. It is shown that the plasma density in such a system is three orders of magnitude higher than that in conventional dc magnetron discharges and reaches 1013 cm−3 at a distance of 250 mm from the cathode at a peak discharge current of 500 A. The plasma propagates from the cathode region at a velocity of 1 cm/μs in the axial direction and 0.25 cm/μs in the radial direction. Optical emission spectroscopy shows that the degree of plasma ionization increases severalfold with increasing discharge current, mainly at the expense of the sputtered material.  相似文献   

15.
The decay of air plasma produced by a high-voltage nanosecond discharge at room temperature and gas pressures in the range of 1–10 Torr was studied experimentally and theoretically. The time dependence of the electron density was measured with a microwave interferometer. The initial electron density was about 1012 cm−3. The discharge homogeneity was monitored using optical methods. The dynamics of the charged particle densities in the discharge afterglow was simulated by numerically solving the balance equations for electron and ions and the equation for the electron temperature. It was shown that, under these experimental conditions, plasma electrons are mainly lost due to dissociative and three-body recombination with ions. Agreement between the measured and calculated electron densities was achieved only when the rate constant of the three-body electron-ion recombination was increased by one order of magnitude and the temperature dependence of this rate constant was modified. This indicates that the mechanism for three-body recombination of molecular ions differs from that of the well-studied mechanism of atomic ion recombination.  相似文献   

16.
Results from studies of the parameters of a novel type of plasma source—a hollow cathode magnetron—are presented. The magnetron operates at a gas pressure of 5–20 mTorr, the discharge power being in the range of 0.5–4 kW. At discharge powers exceeding 2 kW, a plasma flow with a density of higher than 1011 cm?3 and length of up to 30 cm forms at the magnetron output. Using a grid quartz crystal microbalance, the ionized copper flux fraction was measured as a function of the gas pressure, discharge power, and distance from the target. At gas pressures of higher than 15 mTorr, the degree of ionization at a distance of 31 cm exceeds 50%.  相似文献   

17.
It is demonstrated experimentally that the lifetime of the afterglow plasma of a high-current pulsed discharge in a dielectric tube filled with a mixture of argon with saturated mercury vapor is longer than 1 ms. Such a long lifetime, during which the electron density decreases from 1014 to 1012 cm−3, is explained by the chemi-ionization of mercury vapor by long-lived metastable argon atoms. During this time, the afterglow plasma can serve as a microwave waveguide for a weakly damped low-noise E 0-type axisymmetric surface mode, which allows one to use it for transmission of signals in the centimeter wavelength range.  相似文献   

18.
The denitrification performance of a lab-scale anoxic rotating biological contactor (RBC) using landfill leachate with high nitrate concentration was evaluated. Under a carbon to nitrogen ratio (C/N) of 2, the reactor achieved N-NO3 removal efficiencies above 95% for concentrations up to 100 mg N-NO3  l−1. The highest observed denitrification rate was 55 mg N-NO3  l−1 h−1 (15 g N-NO3  m−2 d−1) at a nitrate concentration of 560 mg N-NO3  l−1. Although the reactor has revealed a very good performance in terms of denitrification, effluent chemical oxygen demand (COD) concentrations were still high for direct discharge. The results obtained in a subsequent experiment at constant nitrate concentration (220 mg N-NO3  l−1) and lower C/N ratios (1.2 and 1.5) evidenced that the organic matter present in the leachate was non-biodegradable. A phosphorus concentration of 10 mg P-PO4 3− l−1 promoted autotrophic denitrification, revealing the importance of phosphorus concentration on biological denitrification processes.  相似文献   

19.
The use of clove oil as a potential anaesthetic for freshwater amphipods was examined at 20 °C. Individuals of Gammarus minus, a common species in southern Illinois, USA, spanning the entire body size range (4.3–14.3 mm), were used to test four anaesthetic concentrations varying from 1.48 × 10−4 ml ml−1 to 5.9 × 10−4 ml ml−1. Small-bodied individuals (mean size = 5.4 mm ± 0.27SE) were used to test additional concentrations, up to 14.7 × 10−4 ml ml−1, a 10-fold span, to identify potential lethal concentrations. At the lowest concentration, time to anaesthesia and recovery was constant at all body sizes. For the three next higher concentrations, time to anaesthesia decreased with increasing concentration while recovery time increased. Activity of amphipods was not affected by the ethanol carrier. In addition, activity did not differ between amphipods that had recovered from anaesthesia and unexposed amphipods. At clove oil concentrations of 8.84 × 10−4 ml ml−1 and 14.7 × 10−4 ml ml−1, mortality was 7 and 40%, respectively, indicating, that 5.9 × 10−4 ml ml−1 was a safe working concentration. No mortality was observed with Gammarus acherondytes, a federally endangered cave amphipod on which the protocol with 80 μl of stock was used in the field. The method enabled us to obtain information on the endangered amphipod which normally would have required the sacrifice of individuals. Thus, research can continue on species for which population numbers are low and for which basic information is needed to formulate meaningful recovery plans.  相似文献   

20.
The objective of this study was to estimate the potential short‐term economic loss as a result of replacing the commercial diamond codend with a square mesh codend, and to compare fish lengths captured in 40 mm square (S40) vs 44 mm commercial hand‐woven diamond (CD44) mesh codends for red mullet (Mullus barbatus), common pandora (Pagellus erythrinus), bogue (Boops boops), European hake (Merluccius merluccius), axillary seabream (Pagellus acarne), and brushtooth lizardfish (Saurida undosquamis). A total of 20 hauls (10 hauls for S40 and 10 hauls for CD44) were conducted onboard a commercial trawler between 27 February and 11 April 2012 in Mersin Bay in the northeastern Mediterranean. Results showed that the 40 mm square mesh codend caught significantly fewer juveniles of all aforementioned species. However, when changing from the commercial diamond codend to the 40 mm square mesh codend the potential economic loss of revenue was found to be 40% in the study period, which covered the final 6 weeks of the fishing season.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号