共查询到20条相似文献,搜索用时 15 毫秒
1.
Effects of local elastic compression on muscle strength, electromyographic, and mechanomyographic responses in the lower extremity 总被引:1,自引:0,他引:1
The purpose of this study was to investigate the effect of elastic compression on muscle strength, electromyographic (EMG), and mechanomyographic (MMG) responses of quadriceps femoris during isometric and isokinetic contractions. Twelve participants performed 5 s isometric maximal voluntary contractions (MVC) and 25 consecutive and maximal isokinetic knee extensions at 60 and 300 °/s with no (control, CC), medium (MC), and high (HC) compression applied to the muscle. The EMG and MMG signals were collected simultaneously with muscle isometric and isokinetic strength data. The results showed that the elevated compression did not improve peak torque, peak power, average power, total work, and regression of torque in the isometric and isokinetic contractions. However, the root mean squared value of EMG in both HC and MC significantly decreased compared with CC at 60 and 300 °/s (p < 0.01). Furthermore, the EMG mean power frequency in HC was significantly higher than that in CC at 60 °/s (p < 0.05) whereas no significant compression effect was found in the MMG mean power frequency. These findings provide preliminary evidence suggesting that the increase in local compression pressure may effectively increase muscle efficiency and this might be beneficial in reducing muscle fatigue during concentric isokinetic muscle contractions. 相似文献
2.
Kyle T. Ebersole Terry J. Housh Glen O. Johnson Tammy K. Evetovich Douglas B. Smith Sharon R. Perry 《European journal of applied physiology and occupational physiology》1998,78(3):264-269
The purpose of this investigation was to examine the effect of leg flexion angle on the relationship between mechanomyographic
(MMG) amplitude and isometric torque production. Adult males (n = 9) performed isometric muscle actions of the leg extensors at 25, 50, 75, and 100 percent maximal voluntary contraction
(%MVC) on a calibrated CYBEX 6000 dynamometer at 25, 50, and 75° below full extension. A piezoelectric MMG recording device
was placed over the mid-portion of the rectus femoris. At 25° of leg flexion, the MMG amplitude increased to 100%MVC. At 50
and 75° of leg flexion, however, MMG amplitude increased to 75%MVC, and then did not change significantly (P > 0.05) between 75 and 100%MVC. These findings indicate that the MMG amplitude-isometric torque relationship is joint angle
specific and may be the result of leg flexion angle differences in: (1) muscle stiffness, or (2) motor unit activation strategies.
Accepted: 2 March 1998 相似文献
3.
C E Cronk A F Roche R Kent D Eichorn R W McCammon 《American journal of physical anthropology》1983,61(2):197-204
Longitudinal principal components (LPC) analysis is used to summarize adolescent trends in subcutaneous fat thickness at three sites (biceps, suprailiac, and abdominal). For each site, component 1 (C1) represents fatness level, and component 2 (C2) represents an increase followed by a decrease (fat wave) in fatness. Components 3-5 (retained for girls only) represent more complicated patterns of change (multiple increases and decreases). Correlations among scores for C1 for each site and among scores for C2 for each site indicate a high correspondence of fatness level and the magnitude of the fat wave. Associations between components and other indicators of maturity are apparent, indicating that serial fat patterns are controlled to some degree by influences affecting other pubescent events. Continuity between childhood fatness levels and adolescent patterns of fatness are relatively weak. Continuity between adolescent and adulthood fatness is somewhat greater. 相似文献
4.
Minoru Shinohara Motoki Kouzaki Takeshi Yoshihisa Tetsuo Fukunaga 《European journal of applied physiology and occupational physiology》1997,76(4):314-319
The mechanical activity of the human quadriceps muscle during maximal incremental cycle ergometry was investigated by mechanomyography
(MMG). MMG and surface electromyography (EMG) recordings of vastus lateralis muscle activity were obtained from nine males.
Cycle ergometry was performed at 60 rev/min and work load was incremented step wise by 20 W (3.2 Nm) every minute until volitional
fatigue. The mean amplitudes of MMG (mMMG) and EMG (mEMG) during the contraction phase were calculated from the last six contractions
in each load. The duration, load and work rate of exercise at exhaustion were 13.3 (1.6) min, 44.1 (5.5) Nm, 276.7 (34.7) W,
respectively. A linear relationship between mMMG and load was evident in each subject (r = 0.868–0.995), while mEMG seemed to dissociate as the load became greater. In the grouped mean data, mMMG was linearly related
to load whether aligned to the absolute (r = 0.995) or maximal (r = 0.995) load. Involvement of the noise component was further investigated by studying passive cycling by four subjects.
Pedals were rotated passively for the first half of each stage (PAS) and the subject then pushed the pedals for the second
half (ACT). In the lighter load region, the mMMG of ACT was as small as that of PAS. However, the change in the mMMG of PAS
was very small compared with that of ACT. In conclusion, this study demonstrates a linear relationship between the mMMG of
the quadriceps muscle and work load during maximal incremental cycle ergometry. The effect of movement noise was thought to
be small and stable.
Accepted: 22 April 1997 相似文献
5.
Mean power frequency and amplitude of the mechanomyographic and electromyographic signals during incremental cycle ergometry. 总被引:2,自引:0,他引:2
S R Perry T J Housh J P Weir G O Johnson A J Bull K T Ebersole 《Journal of electromyography and kinesiology》2001,11(4):299-305
The purpose of this investigation was to determine the relationships for mechanomyographic (MMG) amplitude, MMG mean power frequency (MPF), electromyographic (EMG) amplitude, and EMG MPF versus power output during incremental cycle ergometry. Seventeen adults volunteered to perform an incremental test to exhaustion on a cycle ergometer. The test began at 50 W and the power output was increased by 30 W every 2 min until the subject could no longer maintain 70 rev min(-1). The MMG and EMG signals were recorded simultaneously from the vastus lateralis during the final 10 s of each power output and analyzed. MMG amplitude, MMG MPF, EMG amplitude, EMG MPF, and power output were normalized as a percentage of the maximal value from the cycle ergometer test. Polynomial regression analyses indicated that MMG amplitude increased (P<0.05) linearly across power output, but there was no change (P>0.05) in MMG MPF. EMG amplitude and MPF were fit best (P<0.05) with quadratic models. These results demonstrated dissociations among the time and frequency domains of MMG and EMG signals, which may provide information about motor control strategies during incremental cycle ergometry. The patterns for amplitude and frequency of the MMG signal may be useful for examining the relationship between motor-unit recruitment and firing rate during dynamic tasks. 相似文献
6.
Electromyography (EMG) is the standard modality for measuring muscle activity. However, the convenience and availability of low-cost accelerometer-based wearables makes mechanomyography (MMG) an increasingly attractive alternative modality for clinical applications. Literature to date has demonstrated a strong association between EMG and MMG temporal alignment in isometric and isokinetic contractions. However, the EMG-MMG relationship has not been studied in gait. In this study, the concurrence of EMG- and MMG-detected contractions in the tibialis anterior, lateral gastrocnemius, vastus lateralis, and biceps femoris muscles were investigated in children during self-paced gait. Furthermore, the distribution of signal power over the gait cycle was statistically compared between EMG-MMG modalities. With EMG as the reference, muscular contractions were detected based on MMG with balanced accuracies between 88 and 94% for all muscles except the gastrocnemius. MMG signal power differed from that of EMG during certain phases of the gait cycle in all muscles except the biceps femoris. These timing and power distribution differences between the two modalities may in part be related to muscle fascicle length changes that are unique to muscle motion during gait. Our findings suggest that the relationship between EMG and MMG appears to be more complex during gait than in isometric and isokinetic contractions. 相似文献
7.
Kumi Akataki Katsumi Mita Yasushi Itoh 《European journal of applied physiology and occupational physiology》1999,80(3):173-179
A mechanomyogram (MMG) is considered to represent the pressure waves resulting from the lateral expansion of contracting muscle fibers. However, the actual MMG recording appears not only to reflect lateral changes of active fibers, but also to include the effect of their longitudinal shortening, because the fiber orientation, particularly in pennate muscles, is not parallel with the MMG transducer attached at the skin surface. In the present investigation, a spectral decomposition method was developed to eliminate the interference due to fiber longitudinal movement from the MMG recording. The MMG was recorded over the belly of the rectus femoris muscle, which is a pennate muscle. Vibration over the tibial tuberosity (VTT) was used as a measure of the integrated longitudinal movement of the muscle fibers. The lateral and longitudinal components included in the MMG were separated by a spectral decomposition method that is based on the coherence function of the MMG and VTT. The MMG/force relationship was compared between the original and decomposed MMG. One-third of the 12 subjects demonstrated a curvilinear relationship between the original MMG and force throughout the range of force. In the other two-thirds, the MMG saturated or reduced beyond 70% of the maximum voluntary contraction (MVC). After decomposition, the MMG increased progressively with force up to 70% MVC, beyond which it decreased in all subjects. The spectral decomposition method described here is considered to be a useful tool with which to examine in more detail the MMG/force relationship of different pennate muscles. 相似文献
8.
《Journal of electromyography and kinesiology》2014,24(5):614-620
In this study, we aimed to compare the intrarater reliability and validity of muscle thickness measured using ultrasonography (US) and muscle activity via electromyography (EMG) during manual muscle testing (MMT) of the external oblique (EO) and lumbar multifidus (MF) muscles. The study subjects were 30 healthy individuals who underwent MMT at different grades. EMG was used to measure the muscle activity in terms of ratio to maximum voluntary contraction (MVC) and root mean square (RMS) metrics. US was used to measure the raw muscle thickness, the ratio of muscle thickness at MVC, and the ratio of muscle thickness at rest. One examiner performed measurements on each subject in 3 trials. The intrarater reliabilities of the % MVC RMS and raw RMS metrics for EMG and the % MVC thickness metrics for US were excellent (ICC = 0.81–0.98). There was a significant difference between all the grades measured using the % MVC thickness metric (p < 0.01). Further, this % MVC thickness metric of US showed a significantly higher correlation with the EMG measurement methods than with the others (r = 0.51–0.61). Our findings suggest that the % MVC thickness determined by US was the most sensitive of all methods for assessing the MMT grade. 相似文献
9.
Cramer JT Housh TJ Weir JP Johnson GO Ebersole KT Perry SR Bull AJ 《Journal of strength and conditioning research / National Strength & Conditioning Association》2002,16(3):399-408
The purpose of this study was to examine the responses of peak torque (PT), mean power output (MP), mechanomyographic (MMG) and electromyographic (EMG) amplitudes, and mean power frequencies (MPFs) of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) in men and women during dynamic muscle actions. Twelve women (mean +/- SD age = 22 +/- 3 years) and 11 men (22 +/- 3 years) performed maximal, concentric, isokinetic leg extensions at velocities of 60, 120, 180, 240, and 300 degrees x s(-1) on a Cybex 6000 dynamometer. Piezoelectric MMG-recording sensors and bipolar surface EMG electrodes were placed over the VL, RF, and VM muscles. No sex-related differences were found among the velocity-related patterns for PT, MP, MMG amplitude, MMG MPF, or EMG MPF. There were, however, sex-related differences in the patterns of EMG amplitude across velocity. The results indicated similar velocity-related patterns of increase of MP and MMG amplitude for all 3 muscles and of EMG amplitude for the VL and VM in the women. Velocity-related decreases (p 0.05) across velocity. MMG MPF increased (p < or = 0.05) only between 240 and 300 degrees x s(-1). Overall, these findings suggested that there were sex- and muscle-specific, velocity-related differences in the associations among motor unit activation strategies (EMG amplitude and MPF) and the mechanical aspects of muscular activity (MMG amplitude and MPF). With additional examination and validation, however, MMG may prove useful to practitioners for monitoring training-induced changes in muscle power output. 相似文献
10.
J. Celichowski K. Grottel E. Bichler 《European journal of applied physiology and occupational physiology》1998,78(4):283-288
In previous studies on mechanomyogram (MMG) signals no analysis of these signals accompanying force generation has been performed.
Therefore, we have recorded MMG signals (previously referred to as muscle sound or acoustomyographic signals) during voluntary
contractions of forefinger flexor muscles in 31 young subjects. These subjects made contractions to produce force records
of triangular or trapeziform shape. The peak target force amounted to 10, 20 or 40 N which represented less than 40% of maximal
voluntary contraction. The MMG signals during the transient phases of force generation at three different rates were analysed.
The MMG intensity level calculated for MMG records and the peak-to-peak amplitude of MMG signals correlated with both the
velocity of force increase and the contraction force. The occurrence of the strongest MMG signals corresponded to changes
in contractile force. Therefore, it is suggested that measurements of these parameters could be a useful tool in studies of
changes in contractile force.
Accepted: 11 March 1998 相似文献
11.
Travis W Beck Terry J Housh Glen O Johnson Joseph P Weir Joel T Cramer Jared W Coburn Moh H Malek 《Journal of electromyography and kinesiology》2005,15(2):190-199
The primary purpose of the present study was to compare the fast Fourier transform (FFT) with the discrete wavelet transform (DWT) for determining the mechanomyographic (MMG) and electromyographic (EMG) center frequency [mean power frequency (mpf), median frequency (mdf), or wavelet center frequency (cf)] patterns during fatiguing isokinetic muscle actions of the biceps brachii. Seven men (mean+/-SD age=23+/-3 years) volunteered to perform 50 consecutive maximal, concentric isokinetic muscle actions of the dominant forearm flexors at a velocity of 180 degrees s(-1). Non-parametric "run" tests indicated significant (p<0.05) trends in the MMG and EMG signals for the 5th, 25th, and 45th muscle actions for all subjects, thereby confirming non-stationarity of the MMG and EMG signals. There were significant (p<0.05) correlations among the average normalized mpf, mdf, and cf values for contractions 1-50 for both MMG (r=0.671-0.935) and EMG (r=0.956-0.987). Polynomial regression analyses demonstrated quadratic decreases in normalized MMG mpf (R2=0.439), MMG mdf (R2=0.258), MMG cf (R2=0.359), EMG mpf (R2=0.952), EMG mdf (R2=0.914) and EMG cf (R2=0.888) across repetitions. The primary finding of this study was the similarity in the mpf, mdf, and cf patterns for both MMG and EMG, which suggested that, despite the concerns over non-stationarity, Fourier based methods are acceptable for determining the patterns for normalized MMG and EMG center frequency during fatiguing dynamic muscle actions at moderate velocities. 相似文献
12.
Coburn JW Housh TJ Cramer JT Weir JP Miller JM Beck TW Malek MH Johnson GO 《Journal of strength and conditioning research / National Strength & Conditioning Association》2005,19(2):412-420
The purpose of this study was to examine the patterns for the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) vs. torque relationships during submaximal to maximal isometric and isokinetic muscle actions. Seven men (mean +/- SD age, 22.4 +/- 1.3 years) volunteered to perform isometric and concentric isokinetic leg extension muscle actions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) and peak torque (PT) on a Cybex II dynamometer. A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes on the vastus medialis. Polynomial regression and separate 1-way repeated-measures analysis of variance were used to analyze the EMG amplitude, MMG amplitude, EMG MPF, and MMG MPF data for the isometric and isokinetic muscle actions. For the isometric muscle actions, EMG amplitude (R(2) = 0.999) and MMG MPF (R(2) = 0.946) increased to MVC, mean MMG amplitude increased to 60% MVC and then plateaued, and mean EMG MPF did not change (p > 0.05) across torque levels. For the isokinetic muscle actions, EMG amplitude (R(2) = 0.988) and MMG amplitude (R(2) = 0.933) increased to PT, but there were no significant mean changes with torque for EMG MPF or MMG MPF. The different torque-related responses for EMG and MMG amplitude and MPF may reflect differences in the motor control strategies that modulate torque production for isometric vs. dynamic muscle actions. These results support the findings of others and suggest that isometric torque production was modulated by a combination of recruitment and firing rate, whereas dynamic torque production was modulated primarily through recruitment. 相似文献
13.
John Paul V. Anders Joshua L. Keller Tyler J. Neltner Terry J. Housh Richard J. Schmidt Glen O. Johnson 《Journal of musculoskeletal & neuronal interactions》2021,21(1):4
Objectives:The purpose of the present study was to compare the fatigue-induced changes in performance fatigability, bilateral deficit, and patterns of responses for the electromyographic (EMG) and mechanomyographic (MMG) amplitude (AMP) and mean power frequency (MPF), during unilateral and bilateral maximal, fatiguing leg extensions.Methods:Nine men (Mean±SD; age =21.9±2.4 yrs; height =181.8±11.9 cm; body mass =85.8±6.2 kg) volunteered to perform 50 consecutive maximal, bilateral (BL), unilateral dominant (DL), and unilateral non-dominant (NL) isokinetic leg extensions at 180°·s-1, on 3 separate days. Electromyographic and MMG signals from both vastus lateralis (VL) muscles were recorded. Repeated measures ANOVAs were utilized to examine mean differences in normalized force, EMG AMP, EMG MPF, MMG AMP, MMG MPF and the bilateral deficit.Results:The results demonstrated a Condition × Repetition interaction for normalized force (p=0.004, η2p=0.222) and EMG MPF (p=0.034, η2p=0.214) and main effects for Repetition for EMG AMP (p=0.019, η2p=0.231), MMG AMP (p<0.001, η2p=0.8550), MMG MPF (p=0.009, η2p=0.252), and the bilateral deficit (p<0.001, η2p=0.366).Conclusions:The findings demonstrated less performance fatigability during the BL than the unilateral tasks, likely due to a reduced relative intensity via interhemispheric inhibition that attenuated the development of excitation-contraction coupling failure during the BL task. 相似文献
14.
Travis W Beck Terry J Housh Glen O Johnson Joseph P Weir Joel T Cramer Jared W Coburn Moh H Malek 《Journal of electromyography and kinesiology》2005,15(5):482-495
The purpose of this study was to examine the effects of interelectrode distance (IED) on the absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isokinetic and isometric torque relationships for the biceps brachii muscle. Ten adults [mean+/-SD age=22.0+/-3.4 years] performed submaximal to maximal, isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects performed randomly ordered, submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the biceps brachii muscle with IEDs of 20, 40, and 60mm. Absolute and normalized EMG amplitude (muVrms and %max) increased linearly with torque during the isokinetic and isometric muscle actions (r(2) range=0.988-0.998), but there were no significant changes for absolute or normalized EMG MPF (Hz or %max) from 10% to 100% PT and MVC. In some cases, there were significant (p<0.05) differences among the three IED arrangements for absolute EMG amplitude and MPF values, but not for the normalized values. These findings suggested that for the biceps brachii muscle, IEDs between 20 and 60mm resulted in similar patterns for the EMG amplitude or MPF versus dynamic and isometric torque relationships. Furthermore, unlike the absolute EMG amplitude and MPF values, the normalized EMG data were not influenced by changes in IED between 20 and 60mm. Thus, normalized EMG data can be compared among previous studies that have utilized different IED arrangements. 相似文献
15.
Jorge M. Zuniga Terry J. Housh Clayton L. Camic C. Russell Hendrix Haley C. Bergstrom Richard J. Schmidt Glen O. JohnsonAuthor vitae 《Journal of electromyography and kinesiology》2011,21(5):789-794
The purpose of this study was to examine the effects of skinfold (SF) thicknesses at four locations on the vastus lateralis (VL) muscle and the placement of accelerometers relative to the innervation zone (IZ) on the mechanomyographic (MMG) amplitude and mean power frequency (MPF) responses during incremental cycle ergometry. Twenty adults (age ± SD = 23.8 ± 3.0 years) participated in the investigation. The MMG signals were detected during incremental cycle ergometry using four accelerometers placed on the right VL. Prior to the cycle ergometer test, SF thicknesses were measured. Simple linear regression analyses and one-way repeated measures analyses of variance (ANOVAs) were performed. The present study found that only 10% of the regression analyses and mean comparisons were significant (p < 0.05). Furthermore, the accelerometer placed at the most proximal site (Prox 2) had significantly greater MMG amplitude and MMG MPF than accelerometers placed at more distal sites (Prox 1, Over IZ, and Dist). There were no significant differences, however, in SF thickness between accelerometer placement sites. In addition, the IZ had no effect on MMG amplitude and little effect on MMG MPF values. The results of the present study indicated that the SF thickness values and IZ did not affect the MMG signal. 相似文献
16.
Surface electromyography (sEMG) is commonly used to estimate muscle demands in occupational tasks. To allow for comparisons, sEMG amplitude is normalized to muscle specific maximum voluntary contractions (MVCs) performed in a standardized set of postures. However, maximal sEMG amplitude in shoulder muscles is highly dependent on arm posture and therefore, normalizing task related muscular activity to standard MVCs may lead to misinterpretation of task specific muscular demands. Therefore, the purpose of this study was to investigate differences in commonly monitored shoulder muscles using normalized sEMG amplitude between maximal exertions at different hand locations and across force exertion directions relative to standard MVCs. sEMG was recorded from the middle deltoid, pectoralis major sternal head, infraspinatus, latissimus dorsi, and upper trapezius. Participants completed standardized muscle-specific MVCs and two maximal exertions in 5 hand locations (low left, low right, high left, high right, and central) in each of the four force directions (push, pull, up, and down). Peak sEMG was analyzed in the direction(s) that elicited the highest signal for each muscle. All muscles differed by location (p < 0.05). Latissimus dorsi had the greatest activation during pulls (32–135% MVC); upper trapezius and middle deltoid while exerting upwards (73–103% and 42–78% MVC, respectively); infraspinatus while pushing (38–79% MVC); and pectoralis major activation was the highest during downwards exertions (48–84% MVC). Normalization of location specific maximal exertions to standard muscle specific MVCs underestimated maximal activity across 90% of the tasks in all shoulder muscles tested, except for latissimus dorsi where amplitudes were overestimated in low right hand location. Normalization of location specific muscle activity to standard muscle specific MVCs often underestimates muscle activity in task performance and is cautioned against if the goal is to accurately estimate muscle demands. 相似文献
17.
Mohamad Razif Mohamad Ismail Chee Kiang Lam Kenneth Sundaraj Mohd Hafiz Fazalul Rahiman 《Journal of musculoskeletal & neuronal interactions》2021,21(4):481
Objective:This paper presents the analyses of the fatigue effect on the cross-talk in mechanomyography (MMG) signals of extensor and flexor forearm muscles during pre- and post-fatigue maximum voluntary isometric contraction (MVIC).Methods:Twenty male participants performed repetitive submaximal (60% MVIC) grip muscle contractions to induce muscle fatigue and the results were analyzed during the pre- and post-fatigue MVIC. MMG signals were recorded on the extensor digitorum (ED), extensor carpi radialis longus (ECRL), flexor digitorum superficialis (FDS) and flexor carpi radialis (FCR) muscles. The cross-correlation coefficient was used to quantify the cross-talk values in forearm muscle pairs (MP1, MP2, MP3, MP4, MP5 and MP6). In addition, the MMG RMS and MMG MPF were calculated to determine force production and muscle fatigue level, respectively.Results:The fatigue effect significantly increased the cross-talk values in forearm muscle pairs except for MP2 and MP6. While the MMG RMS and MMG MPF significantly decreased (p<0.05) based on the examination of the mean differences from pre- and post-fatigue MVIC.Conclusion:The presented results can be used as a reference for further investigation of cross-talk on the fatigue assessment of extensor and flexor muscles’ mechanic. 相似文献
18.
Beck TW Housh TJ Cramer JT Weir JP Johnson GO Coburn JW Malek MH Mielke M 《Biomedical engineering online》2005,4(1):67
The purpose of this review is to examine the literature that has investigated mechanomyographic (MMG) amplitude and frequency
responses during dynamic muscle actions. To date, the majority of MMG research has focused on isometric muscle actions. Recent
studies, however, have examined the MMG time and/or frequency domain responses during various types of dynamic activities,
including dynamic constant external resistance (DCER) and isokinetic muscle actions, as well as cycle ergometry. Despite the
potential influences of factors such as changes in muscle length and the thickness of the tissue between the muscle and the
MMG sensor, there is convincing evidence that during dynamic muscle actions, the MMG signal provides valid information regarding
muscle function. This argument is supported by consistencies in the MMG literature, such as the close relationship between
MMG amplitude and power output and a linear increase in MMG amplitude with concentric torque production. There are still many
issues, however, that have yet to be resolved, and the literature base for MMG during both dynamic and isometric muscle actions
is far from complete. Thus, it is important to investigate the unique applications of MMG amplitude and frequency responses
with different experimental designs/methodologies to continually reassess the uses/limitations of MMG. 相似文献
19.
Compliant foams can be used to mitigate ground reaction forces. However, it is unknown how foam surfaces influence the modulation of leg muscle activity. Thus, the current study aimed to investigate how the neuromuscular system managed changes in expected loading due to various thickness of foam placed on the landing surface during a step down task. The surface electromyographic signal (sEMG) pre-activation duration and the root mean square (RMS) amplitude of tibialis anterior (TA), lateral gastrocnemius (LG), and vastus medialis (VM) of 10 active females were measured as they stepped-down with a single leg onto polyurethane foam slabs of varying thickness (0–50 mm). Pre-activation duration was not affected by the thickness of the foam padding. LG RMS amplitude was less in the foam conditions than the control (no– foam) condition, with the greatest reduction observed for the 50 mm foam condition. In some trials, the muscles remained active throughout the step-down task. In such instances, a sEMG onset time and thus a pre-activation duration could not be determined. All foam conditions significantly increased the odds of continuous muscle activity above that of the no-foam condition. The results indicate that foam surfaces may alter the modulation of muscle activity during step-down tasks. 相似文献
20.
The purpose of this study was to describe and examine the variations in recruitment patterns of motor units (MUs) in biceps brachii (BB) through a range of joint motion during dynamic eccentric and concentric contractions. Twelve healthy participants (6 females, 6 males, age = 30 ± 8.5 years) performed concentric and eccentric contractions with constant external loading at different levels. Surface electromyography (EMG) and mechanomyography (MMG) were recorded from BB. The EMGs and MMGs were decomposed into their intensities in time–frequency space using a wavelet technique. The EMG and MMG spectra were then compared using principal component analysis. Variations in total intensity, first principal component (PCI), and the angle θ formed by first component (PCI) and second component (PCII) loading scores were explained in terms of MU recruitment patterns and elbow angles. Elbow angle had a significant effect on dynamic concentric and eccentric contractions. The EMG total intensity was greater for concentric than for eccentric contractions in the present study. MMG total intensity, however, was lower during concentric than during eccentric contractions. In addition, there was no significant difference in θ between concentric and eccentric contractions for both EMG and MMG. Selective recruitment of fast MUs from BB muscle during eccentric muscle contractions was not found in the present study. 相似文献