首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
This work describes the electrochemical and electrocatalytic properties of carbon ceramic electrode (CCE) modified with lead nitroprusside (PbNP) nanoparticles as a new electrocatalyst material. The structure of deposited film on the CCE was characterized by energy dispersive X-ray (EDX), Fourier transform infrared (FTIR), and scanning electron microscopy (SEM). The cyclic voltammogram (CV) of the PbNP modified CCE showed two well-defined redox couples due to [Fe(CN)5NO]3−/[Fe(CN)5NO]2− and PbIV/PbII redox reactions. The modified electrode showed electrocatalytic activity toward the oxidation of l-cysteine and was used as an amperometric sensor. Also, to reduce the fouling effect of l-cysteine and its oxidation products on the modified electrode, a thin film of Nafion was coated on the electrode surface. The sensor response was linearly changed with l-cysteine concentration in the range of 1 × 10−6 to 6.72 × 10−5 mol L−1 with a detection limit (signal/noise ratio [S/N] = 3) of 0.46 μM. The sensor sensitivity was 0.17 μA (μM)−1, and some important advantages such as simple preparation, fast response, good stability, interference-free signals, antifouling properties, and reproducibility of the sensor for amperometric determination of l-cysteine were achieved.  相似文献   

2.
A novel amperometric biosensor for xanthine was developed based on covalent immobilization of crude xanthine oxidase (XOD) extracted from bovine milk onto a hybrid nanocomposite film via glutaraldehyde. Toward the preparation of the film, a stable colloids solution of core–shell Fe3O4/polyaniline nanoparticles (PANI/Fe3O4 NPs) was dispersed in solution containing chitosan (CHT) and H2PtCl6 and electrodeposited over the surface of a carbon paste electrode (CPE) in one step. Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) were used for characterization of the electrode surface. The developed biosensor (XOD/CHT/Pt NPs/PANI/Fe3O4/CPE) was employed for determination of xanthine based on amperometric detection of hydrogen peroxide (H2O2) reduction at –0.35 V (vs. Ag/AgCl). The biosensor exhibited a fast response time to xanthine within 8 s and a linear working concentration range from 0.2 to 36.0 μM (R2 = 0.997) with a detection limit of 0.1 μM (signal/noise [S/N] = 3). The sensitivity of the biosensor was 13.58 μA μM−1 cm−2. The apparent Michaelis–Menten (Km) value for xanthine was found to be 4.7 μM. The fabricated biosensor was successfully applied for measurement of fish and chicken meat freshness, which was in agreement with the standard method at the 95% confidence level.  相似文献   

3.
A modified electrode, nickel(II)-baicalein complex modified multiwall carbon nanotube paste electrode (Ni(II)-BA-MWCNT-PE), has been fabricated by electrodepositing Ni(II)-BA complex on the surface of MWCNT-PE in alkaline solution. The Ni(II)-BA-MWCNT-PE exhibits the characteristic of improved reversibility and enhanced current responses of the Ni(III)/Ni(II) couple compared with Ni(II)-BA-carbon paste electrode (CPE). It also shows better electrocatalytic activity toward the oxidation of glycine than Ni(II)-MWCNT-PE. Kinetic parameters such as the electron transfer coefficient α, rate constant ks of the electrode reaction, the diffusion coefficient D of glycine, and the catalytic rate constant kcat of the catalytic reaction are determined. Moreover, the catalytic currents present linear dependence on the concentration of glycine from 20 μM to 1.0 mM by amperometry. The detection limit and sensitivity are 9.2 μM and 3.92 μA mM−1, respectively. The modified electrode for glycine determination is of the property of simple preparation, fast response, and good stability.  相似文献   

4.
A novel nanocomposite material of multiwalled carbon nanotubes (MWCNTs) and room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) was explored and used to construct a novel microperoxidase-11 (MP-11) biosensor for the determination of hydrogen peroxide (H2O2). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the performance of the biosensor. Under the optimized experimental conditions, H2O2 could be detected in a linear calibration range of 0.5 to 7.0 × 10−7 mol L−1 with a correlation coefficient of 0.9949 (n = 9) and a detection limit of 3.8 × 10−9 mol L−1 at 3σ. The modified electrodes displayed excellent electrochemical response, high sensitivity, long-term stability, and good bioactivity and selectivity.  相似文献   

5.
An interesting electrochemical sensor has been constructed by the electrodeposition of palladium nanoclusters (Pdnano) on poly(N-methylpyrrole) (PMPy) film-coated platinum (Pt) electrode. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy were used to characterize the properties of the modified electrode. It was demonstrated that the electroactivity of the modified electrode depends strongly on the electrosynthesis conditions of the PMPy film and Pdnano. Moreover, the modified electrode exhibits strong electrocatalytic activity toward the oxidation of a mixture of dopamine (DA), ascorbic acid (AA), and uric acid (UA) with obvious reduction of overpotentials. The simultaneous analysis of this mixture at conventional (Pt, gold [Au], and glassy carbon) electrodes usually struggles. However, three well-resolved oxidation peaks for AA, DA, and UA with large peak separations allow this modified electrode to individually or simultaneously analyze AA, DA, and UA by using differential pulse voltammetry (DPV) with good stability, sensitivity, and selectivity. This sensor is also ideal for the simultaneous analysis of AA, UA and either of epinephrine (E), norepinephrine (NE) or l-DOPA. Additionally, the sensor shows strong electrocatalytic activity towards acetaminophen (ACOP) and other organic compounds. The calibration curves for AA, DA, and UA were obtained in the ranges of 0.05 to 1 mM, 0.1 to 10 μM, and 0.5 to 20 μM, respectively. The detection limits (signal/noise [S/N] = 3) were 7 μM, 12 nM, and 27 nM for AA, DA, and UA, respectively. The practical application of the modified electrode was demonstrated by measuring the concentrations of AA, DA, and UA in injection sample, human serum, and human urine samples, respectively, with satisfactory results. The reliability and stability of the modified electrode gave a good possibility for applying the technique to routine analysis of AA, DA, and UA in clinical tests.  相似文献   

6.
GOX is the most widely used enzyme for the development of electrochemical glucose biosensors and biofuel cell in physiological conditions. The present work describes the production of a recombinant glucose oxidase from Penicillium amagasakiense (yGOXpenag) displaying a more efficient glucose catalysis (kcat/KM(glucose) = 93 μM−1 s−1) than the native GOX from Aspergillus niger (nGOXaspng), which is the most industrially used (kcat/KM(glucose) = 27 μM−1 s−1). Expression in Pichia pastoris allowed easy production and purification of the recombinant active enzyme, without overglycosylation. Its biotechnological interest was further evaluated by measuring kinetics of ferrocinium-methanol (FMox) reduction, which is commonly used for electron transfer to the electrode surface. Despite their homologies in sequence and structure, pH-dependant FMox reduction was different between the two enzymes. At physiological pH and temperature, we observed that electron transfer to the redox mediator is also more efficient for yGOXpenag than for nGOXaspng(kcat/KM(FMox) = 27 μM−1 s−1 and 17 μM−1 s−1 respectively). In our model system, the catalytic current observed in the presence of blood glucose concentration (5 mM) was two times higher with yGOXpenag than with nGOXaspng. All our results indicated that yGOXpenag is a better candidate for industrial development of efficient bioelectrochemical devices used in physiological conditions.  相似文献   

7.
The composite film based on Nafion and hydrophilic room temperature ionic liquid (RTIL) 1-butyl-3-methyl-imidazolium chloride ([bmim]Cl) was used as an immobilization matrix to entrap myoglobin (Mb). The study of ionic liquid (IL)-Mb interaction by ultraviolet-visible (UV-vis) spectroscopy showed that Mb retains its native conformation in the presence of IL. The immobilized Mb displayed a pair of well-defined cyclic voltammetric peaks with a formal potential (Eo) of −0.35 V in a 0.1 M phosphate buffer solution (PBS) of pH 7.0. The immobilized Mb exhibited excellent electrocatalytic response to the reduction of hydrogen peroxide, based on which a mediator-free amperometric biosensor for hydrogen peroxide was designed. The linear range for the determination of hydrogen peroxide was from 1.0 to 180 μM with a detection limit of 0.14 μM at a signal/noise ratio of 3. The apparent Michaelis constant () for the electrocatalytic reaction was 22.6 μM. The stability, repeatability, and selectivity of the sensor were evaluated. The proposed biosensor has a lower detection limit than many other IL-heme protein-based biosensors and is free from common interference in hydrogen peroxide biosensors.  相似文献   

8.
Large catalase based bioelectrode for biosensor application   总被引:1,自引:0,他引:1  
A large catalase (CAT) (Mr ~ 90 kDa), immobilized on multiwalled carbon nanotubes—Nafion® (MWCNT-NF) matrix and encapsulated with polyethylenimine (PEI) on glassy carbon electrode (GCE), showed a pair of nearly reversible cyclic voltammetric peaks for Fe(III)/Fe(II) couple with formal potential of about −0.45 V (vs. Ag/AgCl electrode at pH 7.5). PEI significantly reduced the charge transfer resistance and stabilized the bioelectrode through electrostatic interaction. The electron transfer rate constant and surface coverage of the immobilized CAT were 1.05 ± 0.2 s−1 and 2.1 × 10−10 mol cm−2, respectively. Studies on electrocatalytic activity and kinetics of GCE/MWCNT-NF/CAT/PEI for hydrogen peroxide (H2O2) showed the apparent Michaelis-Menten constant of 3 mM, linear response in the range of 10 μM to 5 mM, response time of ~ 2 s for steady state current, and detection limit of ~ 1 μM. A high operational and storage stability was also demonstrated for the bioelectrode. Hence, the direct electrochemistry of the large catalase and its potential biosensor application have been established through this investigation.  相似文献   

9.
Li Shen 《BBA》2004,1608(1):23-33
Biocompatible nanosized polyamidoamine (PAMAM) dendrimer films provided a suitable microenvironment for heme proteins to transfer electron directly with underlying pyrolytic graphite (PG) electrodes. Hemoglobin (Hb), myoglobin (Mb), horseradish peroxidase (HRP), and catalase (Cat) incorporated in PAMAM films exhibited a pair of well-defined, quasi-reversible cyclic voltammetric peaks, respectively, characteristic of the protein heme Fe(III)/Fe(II) redox couples. While Hb-, Mb-, and HRP-PAMAM films showed the cyclic voltammetry (CV) peaks at about −0.34 V vs. saturated calomel electrode (SCE) in pH 7.0 buffers, Cat-PAMAM films displayed the peak pair at a more negative potential of −0.47 V. The protein-PAMAM films demonstrated a surface-confined or thin-layer voltammetric behavior. The electrochemical parameters such as apparent heterogeneous electron transfer rate constants (ks) and formal potentials (E°′) were estimated by square wave voltammetry with nonlinear regression analysis. UV-vis and IR spectroscopy showed that the proteins retained their near-native secondary structures in PAMAM films. Oxygen, hydrogen peroxide, and nitrite were catalytically reduced at the protein-PAMAM film electrodes, showing the potential applicability of the films as the new type of biosensors or bioreactors based on direct electrochemistry of the proteins.  相似文献   

10.
Reactive oxygen species (ROS) are known to mediate a variety of biological responses, including cell motility. Recently, we indicated that lysophosphatidic acid (LPA) receptor-3 (LPA3) increased cell motile activity stimulated by hydrogen peroxide. In the present study, we assessed the role of LPA1 in the cell motile activity mediated by ROS in mouse fibroblast 3T3 cells. 3T3 cells were treated with hydrogen peroxide and 2,3-dimethoxy-1,4-naphthoquinone (DMNQ) at concentrations of 0.1 and 1 μM for 48 h. In cell motility assays with Cell Culture Inserts, the cell motile activities of 3T3 cells treated with hydrogen peroxide and DMNQ were significantly higher than those of untreated cells. 3T3 cells treated with hydrogen peroxide and DMNQ showed elevated expression levels of the Lpar3 gene, but not the Lpar1 and Lpar2 genes. To investigate the effects of LPA1 on the cell motile activity induced by hydrogen peroxide and DMNQ, Lpar1-overexpressing (3T3-a1) cells were generated from 3T3 cells and treated with hydrogen peroxide and DMNQ. The cell motile activities stimulated by hydrogen peroxide and DMNQ were markedly suppressed in 3T3-a1 cells. These results suggest that LPA signaling via LPA1 inhibits the cell motile activities stimulated by hydrogen peroxide and DMNQ in 3T3 cells.  相似文献   

11.
A sensitive and convenient electrochemical assay of plasmin activity and its kinetic analysis are described. Thus, a ferrocenyl peptide substrate (FcPS) having a plasmin-specific substrate sequence, Lys-Thr-Phe-Lys, and a Cys residue was prepared and immobilized on a gold electrode through the sulfur-gold linkage. The obtained electrode showed a redox signal based on the ferrocene moiety, suggesting the immobilization of FcPS on the electrode. After treatment of this electrode with plasmin, its electrochemical signal was decreased in proportion to an increase of the amount of plasmin. The detection limit for plasmin in this assay system was as low as 50 ng/ml or 0.15 mU/ml. Real-time monitoring of plasmin reaction on the electrode could also be achieved, and the kinetic parameters of this enzymatic reaction could be determined; for example, the kcat/Km value was 0.063 μM−1 s−1. Furthermore, a quantitative assay for streptokinase as a plasminogen activator was also demonstrated by using this system.  相似文献   

12.
Stoichiometry of the electrocatalytical cycle of cytochrome P450 2B4 was studied in kinetic mode according to bielectrode scheme. Graphite screen-printed electrodes with immobilized cytochrome P450 2B4 were used as the operating electrode (at the potential E0′ = −450 mV) and electrodes, modified with cytochrome c (E0′ = −50 mV) or Prussian Blue (E0′ = 0), as measuring electrodes (for H2O2) and Clark-type electrode (for O2). Benzphetamine N-demethylation rate was 17 ± 3 nmol/nmol of enzyme/min, peroxide production was 4.8 ± 0.7 nmol/nmol of enzyme/min (substrate-free system), 3.3 ± 0.6 nmol/nmol of enzyme/min (0.5 mM benzphetamine), the oxygen consumption rate by Р450 2В4 was 19.4 ± 0.6 nmol/nmol of enzyme/min (in the presence of benzphetamine), 4.8 ± 0.4 nmol/nmol of enzyme/min (without substrate). Based on stoichiometry of P450 electrocatalysis adequacy of electrochemical reduction and P450-monooxygenase system was revealed.  相似文献   

13.
Electrically active magnetic nanocomposites (EAMNCs), Au nanoparticles/self-doped polyaniline@Fe3O4 (AuNPs/SPAN@Fe3O4) with well-defined core/shell structure, were first synthesized by a simple method. The morphology and composition of the as-synthesized AuNPs/SPAN@Fe3O4 nanocomposite have been characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier transform infrared (FT–IR), ultraviolet–visible (UV–Vis), X-ray powder diffraction (XRD), and thermogravimetric analysis (TGA). Horseradish peroxidase (HRP)–AuNPs/SPAN@Fe3O4 biocomposites were immobilized onto the surface of indium tin oxide (ITO) electrode to construct an amperometric hydrogen peroxide (H2O2) biosensor. The effects of HRP dosage, solution pH, and the working potential on the current response toward H2O2 reduction were optimized to obtain the maximal sensitivity. Under the optimal conditions, the proposed biosensor exhibited a linear calibration response in the range of 0.05 to 0.35 mM and 0.35 to 1.85 mM, with a detection limit of 0.01 mM (signal-to-noise ratio = 3). The modified electrode could virtually eliminate the interference of ascorbic acid (AA) and uric acid (UA) during the detection of H2O2. Furthermore, the biosensor was applied to detect H2O2 concentration in real samples, which showed acceptable accuracy with the traditional potassium permanganate titration.  相似文献   

14.
We have designed a simple and novel electrochemical biosensor based on glassy carbon electrode (GCE) for DNA detection. GCE was modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) by the electrochemical method, which is helpful for immobilization of thiolated bioreceptors. The electrode modification processes were characterized by scanning electron microscopy (SEM) and electrochemical methods. Then a single-stranded DNA (ssDNA) probe for BRCA1 5382 insC mutation detection was immobilized on the modified electrode for a specific time. The experimental conditions, such as probe immobilization time and target DNA (complementary DNA) hybridization time and temperature with probe DNA, were optimized using electrochemical methods. The electrochemical response for DNA hybridization and synthesis was measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods. The calibration graph contains two linear ranges; the first part is in the range of 3.0 × 10−20 to 1.0 × 10−12 M, and the second segment part is in the range of 1.0 × 10−12 to 1.0 × 10−7 M. The biosensor showed excellent selectivity for the detection of the complementary sequences from noncomplementary sequences, so it can be used for detection of breast cancer.  相似文献   

15.
Real-time investigation of molecular recognition between protein and the photosensitizer of photodynamic therapy (PDT) was carried out by a quartz crystal microbalance (QCM) sensor integrated into a flow injection analysis (FIA) system. The photosensitizer meso-tetrakis(4-hydroxyphenyl)porphyrin (p-THPP) was immobilized on the gold electrode of the QCM chip by combining the sol-gel and self-assembly methods. Such a rapid screen analysis of molecular recognition showed that the p-THPP-immobilized sensor exhibited sensitive and specific interaction only with hemoglobin (Hb). The kinetic rate constants (kass and kdiss) and the equilibrium association constant (KA) for p-THPP-Hb interaction were calculated by linear regression. The sensing performance characteristics of the proposed sensor were investigated. The sensor showed excellent selectivity, reproducibility, and repeatability for the detection of Hb. A linear calibration plot was obtained over a range from 0.2 to 1.0 μM with a detection limit (signal/noise ratio = 3) of 0.15 μM. The response mechanism of the sensor is discussed in detail. Due to its low cost and simple manipulation, this QCM-FIA system was shown to be a highly effective method for the investigation of interaction between biomacromolecules and the PDT photosensitizer. It also provides a potential strategy for screening an efficient and less harmful photosensitizer for PDT application.  相似文献   

16.
The tetranuclear and pentanuclear mixed-valence coordination compounds Na[(NC)5FeII-μ(CN)-PtIV(NH3)4-μ(NC)-FeII(CN)4-μ(CN)-RuIII(NH3)5], or FePtFeRu, and [RuIII(NH3)5-μ(NC)-FeII(CN)4-μ(CN)-PtIV(NH3)4-μ(NC)-FeII(CN)4-μ(CN)-RuIII(NH3)5](OSO2CF3)2, or RuFePtFeRu, were synthesized and characterized by IR and UV-Vis spectroscopy, electron microprobe analysis (EPMA), inductively coupled plasma (ICP), and cyclic voltammetry (CV). Both molecules exhibit FeII → PtIV intervalent charge transfer (IVCT) absorptions in the 400-450 nm range and FeII → RuIII transition(s) between 750 and 950 nm. The energies, intensities, and half-widths of these transitions correspond well with those of model compounds. The cyclic voltammogram of FePtFeRu between 0.00 and 0.90 V versus SCE exhibits two quasi-reversible Fe waves at 0.56 and 0.74 V versus SCE, while that for RuFePtFeRu has only one Fe redox event at 0.72 V versus SCE. When the potential of the working electrode is scanned negative of −0.38 V versus SCE, however, both complexes undergo an ECE (electrochemical-chemical-electrochemical) mechanism whereby the electrochemical reduction of Ru(III) is followed by a double electron transfer to reduce Pt(IV) to Pt(II). Upon reduction to Pt(II), the cyanide bridges break and the complexes dissociate into smaller fragments. Irradiation of the FeII → PtIV IVCT transition in both compounds leads to a photolysis solution that contains dissociated Fe(II)-Ru(III) as one of its products. Irradiation of the FeII → RuIII IVCT transition yields a similar UV-Vis spectrum, suggesting that the same intermediate is common to both photolysis mechanisms. The implications of this research within the larger context of multiple electron transfer are also discussed.  相似文献   

17.
Kinetics of the reaction of octacarbonyl dicobalt with ethyl diazoacetate leading to [μ2-{ethoxycarbonyl(methylene)}-μ2-(carbonyl)-bis(tricarbonyl-cobalt)] (Co-Co) (1), dinitrogen, and carbon monoxide were investigated at 10 °C in heptane solution. The initial rate of the reaction was measured by following both the gas evolution and the decrease of the octacarbonyl dicobalt concentration. The rate is first order with respect to octacarbonyl dicobalt and a complex order with respect to ethyl diazoacetate and carbon monoxide depending on the ratio of their concentrations. This is in accord with the formation of a heptacarbonyl dicobalt reactive intermediate (k1 (10 °C) = (1.22 ± 0.06) × 10−3 s−1) for which carbon monoxide and ethyl diazoacetate compete (k−1/k2 (10 °C) = 1.34 ± 0.07).  相似文献   

18.
This article reports the first electrochemical characterization of pain biomarkers that include arachidonic acid (AA), prostaglandin G2 (PGG2), and cyclooxygenase 2 (COX-2). These biomarkers are mediators of pathophysiology of pain, inflammation, and cell proliferation in cancer. The article also reports the development of an electrochemical immunosensor for monitoring these pain biomarkers. The results revealed that direct electron transfer between AA metabolites and the electrode could be easily monitored and that an enzyme-modified electrode dramatically enhanced bioelectrocatalytic activity toward AA. Cyclic voltammetric analysis of AA revealed a concentration-dependent anodic current with a slope of 2.37 and a limit of detection (LOD) of 0.25 nM. This unique AA/gold electrode electron transfer provides a good electrochemical sensing platform for prostaglandin H2 (PGH2) as the basis for quantitation of pain. An amperometric signal intensity of a COX-2 antibody-modified gold electrode was linear with COX-2 concentration in the range of 0.1-0.5 μg/ml and an LOD of 0.095 μg/ml. The results also revealed a linear correlation of the concentration of PGG2 with an LOD of 0.227 μM.  相似文献   

19.
A product isolated from a reaction mixture of Br2 and Ph3 Sn(CH2)13CH3 (3:1 mole ratio) in CHCl3 solution in air was bis{di-μ-hydroxobis[fac-tribromoaquotin(IV)]} heptahydrate, 2[Br3 (H2O)Sn(μ-OH)2 Sn(O2H)Br3] · 7H2O, 2[fac-(1: X = Br)] · 7H2O. Previous reports had indicated that the tin complexes, [fac-(1: X = Cl or Br)], had been obtained in various solvated forms from hydrolysis or oxidation/hydrolysis of appropriate tin(IV) or tin(II) halides. The crystal structure determination, reported here, provides an improved refinement of the core, i.e., [fac-(1: X = Br)], of 2[fac-(1: X = Br)] · 7H2O compared to previous attempts. The solid state structure consists of a central rhomboidal planar Sn2O2 ring. The tin centres have distorted octahedral geometries, with each Br ligand trans to an O atom. The Br ligands, trans to the aqua ligands, form longer bonds to tin at 2.5556(7) and 2.5544(6) Å, than those trans to the bridging OH ligands, between 2.5021(7) and 2.5127(7) Å. The Br, OH and H2O ligands as well as the solvate water molecules are all involved in an extensive hydrogen bonding system in 2[fac-(1: X = Br)] · 7H2O.  相似文献   

20.
ADP-ribosyl cyclase and NAD+ glycohydrolase (CD38, E.C.3.2.2.5) efficiently catalyze the exchange of the nicotinamidyl moiety of NAD+, nicotinamide adenine dinucleotide phosphate (NADP+) or nicotinamide mononucleotide (NMN+) with an alternative base. 4′-Pyridinyl drugs (amrinone, milrinone, dismerinone and pinacidil) were efficient alternative substrates (kcat/KM = 0.9-10 μM−1 s−1) in the exchange reaction with ADP-ribosyl cyclase. When CD38 was used as a catalyst the kcat/KM values for the exchange reaction were reduced two or more orders of magnitude (0.015-0.15 μM−1 s−1). The products of this reaction were novel dinucleotides. The values of the equilibrium constants for dinucleotide formation were determined for several drugs. These enzymes also efficiently catalyze the formation of novel mononucleotides in an exchange reaction with NMN+, kcat/KM = 0.05-0.4 μM−1 s−1. The kcat/KM values for the exchange reaction with NMN+ were generally similar (0.04-0.12 μM−1 s−1) with CD38 and ADP-ribosyl cyclase as catalysts. Several novel heterocyclic alternative substrates were identified as 2-isoquinolines, 1,6-naphthyridines and tricyclic bases. The kcat/KM values for the exchange reaction with these substrates varied over five orders of magnitude and approached the limit of diffusion with 1,6-naphthyridines. The exchange reaction could be used to synthesize novel mononucleotides or to identify novel reversible inhibitors of CD38.  相似文献   