首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The mechanical properties of turkey and heron leg tendons have been investigated in dynamic tensile tests. Heron tendons have properties similar to those found for various mammalian tendons. The Young's modulus and the density of turkey tendons increase with increasing calcification. Ultimate tensile stresses are similar to those found for uncalcified tendon, but Young's modulus may reach about 16 GPa, a value normally associated with bone. Calcification lowers the amount of strain energy that can be stored temporarily in the tendons of the legs. The contribution made by elastic strain energy storage to lowering the cost of running is reduced.  相似文献   

2.
The biomechanical properties of tendinous structures have traditionally been studied using excised material. Limitations associated with displacement measurements and clamping, and uncertainties as to whether in vitro testing represents physiological function, necessitate developing a method for assessing the mechanical properties of tendinous tissue in the in vivo state. This paper reviews recent results taken with an in vivo and noninvasive protocol using ultrasound as a means of measuring tendon-aponeurosis elongation during tensile loading applied by contraction of the in-series muscle. The results obtained indicate that: (1) the Young's modulus and mechanical hysteresis of in vivo tendons is independent of physiological function and loading, (2) there is a strain variation along the tendon-aponeurosis, and (3) in vivo tendons may exhibit creep. These findings agree with reports from experiments on isolated material and have important biological implications for both the tendon and the in-series muscle. The method described here allows designing longitudinal studies on tendon adaptability, but it also has direct clinical applications.  相似文献   

3.
With the aim of studying mechanisms of the remodeling of tendons and ligaments, the effects of stress shielding on the rabbit patellar tendon were studied by performing tensile and stress relaxation tests in the transverse direction. The tangent modulus, tensile strength, and strain at failure of non-treated, control patellar tendons in the transverse direction were 1272 kPa, 370 kPa, and 40.5 percent, respectively, whereas those of the tendons stress-shielded for 1 week were 299 kPa, 108 kPa, and 40.4 percent, respectively. Stress shielding markedly decreased tangent modulus and tensile strength in the transverse direction, and the decreases were larger than those in the longitudinal direction, which were determined in our previous study. For example, tensile strength in the transverse and longitudinal direction decreased to 29 and 50 percent of each control value, respectively, after 1 week stress shielding. In addition, the stress relaxation in the transverse direction of stress-shielded patellar tendons was much larger than that of nontreated, control ones. In contrast to longitudinal tensile tests for the behavior of collagen, transverse tests reflect the contributions of ground substances such as proteoglycans and mechanical interactions between collagen fibers. Ground substances provide lubrication and spacing between fibers, and also confer viscoelastic properties. Therefore, the results obtained from the present study suggest that ground substance matrix, and interfiber and fiber-matrix interactions have important roles in the remodeling response of tendons to stress.  相似文献   

4.
Mechanical properties of collagen fascicles from the rabbit patellar tendon   总被引:1,自引:0,他引:1  
Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils.  相似文献   

5.
Connective tissue susceptibility to nonenzymatic glycation was examined following 0, 2, 4, 6, 8, and 10 weeks of incubating the rabbit Achilles tendon in phosphate-buffered saline containing ribose (glycated). The biomechanical integrity of the glycated tendons was then compared to control tendons incubated in phosphate-buffered saline (non-glycated) at each time interval, while the biochemical stability of both groups of tendons was determined by examining collagen extractability and the formation of pentosidine at 8 weeks. Whereas there were no significant biomechanical differences between control and glycated tendons at 0- and 2-week intervals (P > 0.05), moderately significant increases in maximum load, energy to yield, and toughness of glycated tendons were observed at 4 weeks. Beyond 4 weeks of incubation, the differences between glycated and non-glycated tendons became highly significant, as glycated tendons withstood more load and tensile stress (P < 0.01 for each variable), attained significantly higher modulus of elasticity (P < 0.01), absorbed more energy (P < 0.01), and became tougher (P < 0.01) than controls. These differences in the biomechanical indices of the effects of glycation were stable between the 6th and 10th week of glycation. The maximum increases in the biomechanical measurements as a result of glycation were 29% for maximum load, 125% for stress, 19% for strain, 106% for Young's modulus of elasticity, 14% for energy to yield, and 57% for toughness. Biochemical analysis showed a 61% reduction in the extractability of neutral salt-soluble collagen, a 48% decrease in acid-soluble collagen, and a 29% decline in pepsin-soluble collagen in glycated tendons (P < 0.01). In contrast, there was a 28% increase in the amount of insoluble collagen and significantly higher amounts of pentosidine (P < 0.01) in glycated tendons. Collectively, these biomechanical and biochemical results suggest that nonenzymatic glycation may explain the altered stability of connective tissue matrix induced by the processes of diabetes and aging.  相似文献   

6.
The covariation of a number of mechanical of properties, and some physical characteristics, of compact bones from a wide range of bones were examined. Young's modulus was well predicted by a combination of mineral content and porosity. Increasing Young's modulus was associated with: increasing stress at yield, increasing bending strength, and a somewhat higher resilience, tensile strength and fatigue strength. Contrarily, in the post-yield region a higher Young's modulus (and more clearly, a higher mineral content) was associated with: a reduced work to fracture in tension, a reduced impact strength and an increased notch sensitivity in impact. Increasing porosity is associated with deleterious effects in the pre-yield region, but has little effect in the post-yield region. Bone, like many other materials, is unable to have good qualities in both the pre- and post-yield regions. Since an increase in mineral or Young's modulus is more potent, that is deleterious, in the post-yield than it is advantageous in the pre-yield region, it is likely that mineral content will be selected to be slightly lower than would be the case if it were equally potent in both regions. As is usual in biology, different adaptive extremes are incompatible.  相似文献   

7.
We investigated the possibility that tendons that normally experience relatively high stresses and function as springs during locomotion, such as digital flexors, might develop different mechanical properties from those that experience only relatively low stresses, such as digital extensors. At birth the digital flexor and extensor tendons of pigs have identical mechanical properties, exhibiting higher extensibility and mechanical hysteresis and lower elastic modulus, tensile strength, and elastic energy storage capability than adult tendons. With growth and aging these tendons become much stronger, stiffer, less extensible, and more resilient than at birth. Furthermore, these alterations in elastic properties occur to a significantly greater degree in the high-load-bearing flexors than in the low-stress extensors. At maturity the pig digital flexor tendons have twice the tensile strength and elastic modulus but only half the strain energy dissipation of the corresponding extensor tendons. A morphometric analysis of the digital muscles provides an estimate of maximal in vivo tendon stresses and suggests that the muscle-tendon unit of the digital flexor is designed to function as an elastic energy storage element whereas that of the digital extensor is not. Thus the differences in material properties between mature flexor and extensor tendons are correlated with their physiological functions, i.e., the flexor is much better suited to act as an effective biological spring than is the extensor.  相似文献   

8.
Mechanical hysteresis in tendons has traditionally been quantified from tensile testing of isolated specimens. Limitations associated with tendon displacement measurement and clamping, and uncertainties as to whether in vitro material represents intact tendon function necessitate measuring hysteresis under in vivo conditions. In the present study such measurements were taken in the human tibialis anterior (TA) tendon. Having the foot fixed on a dynamometer footplate, the displacement of the TA tendon during stimulation and relaxation of the TA muscle was recorded by means of ultrasonography in six men. Combining moment data corresponding to 0, 20, 40, 60, 80 and 100% of maximum voltage moment and the respective tendon-displacement data, a hysteresis loop was obtained between the load–displacement curves during contraction and relaxation. Measurement of the hysteresis loop area yielded a value of 19%. This value agrees with results from in vitro tensile tests of low-stress tendons, suitable for tensile force transmission and joint displacement control. In fact, the human TA tendon has such functional characteristics. The methodology presented allows design of longitudinal and cross-sectional experimental protocols, and in vivo assessment of tendon function and propensity to overheat.  相似文献   

9.
Song Y  Zheng Q 《Bioresource technology》2008,99(16):7665-7671
The aim of the present work has been to study the influence of hydrophobic liquids on the morphology and the properties of thermo-molded plastics based on glycerol-plasticized wheat gluten (WG). While the total amount of castor oil and glycerol was remained constant at 30 wt%, castor oil with various proportions with respect to glycerol was incorporated with WG by mixing at room temperature and the resultant mixtures were thermo-molded at 120 degrees C to prepare sheet samples. Moisture absorption, morphology, dynamic mechanical properties, and tensile properties (Young's modulus, tensile strength and elongation at break) of the plastics were evaluated. Experimental results showed that the physical properties of WG plastic were closely related to glycerol to castor oil ratio. Increasing in castor oil content reduces the moisture absorption markedly, which is accompanied with a significant improvement in tensile strength and Young's modulus. These observations were further confirmed in 24 wt% glycerol-plasticized WG plastics containing 6 wt% silicone oil or polydimethylsiloxane (PDMS) liquid rubber.  相似文献   

10.
The purpose of this study is to investigate age-dependent changes in the architecture and mechanical properties of tendon in TGF-beta inducible early gene-1 (TIEG) knockout mice. Wild-type and TIEG knockout mice, aged 1, 2, and 15 mo, were used. The mechanical properties of tail tendons isolated from these mice were determined using uniaxial tensile ramp (0.05 mm/s) and relaxation (5 mm/s) tests, with a strain of 10%. Mechanical parameters (Young's modulus from the ramp test; fast and static stresses from the relaxation test) were measured and recorded. The structure of the tail tendon fascicle was characterized by transmission electron microscopy. The results of the mechanical testing revealed no significant difference between the knockout and wild-type groups at 1 or 15 mo of age. However, the fascicles of the knockout mice at 3 mo of age exhibited decreased fast and static stresses compared with those of the wild-type mice. Electron microscopy revealed an increase in fibril size in the knockout mouse tendons relative to wild-type controls at 1 and 3 mo of age. These data indicate an important role for TIEG in tendon microarchitecture and strength in adult mice.  相似文献   

11.
Growth-related changes in the mechanical properties of collagen fascicles (approximately 300 microm in diameter) were studied using patellar tendons obtained from skeletally immature 1 and 2 months old and matured 6 months old rabbits. Tensile properties were determined using a specially designed micro-tensile tester. In each age group, there were no significant differences in the properties among cross-sectional locations in the tendon. Tangent modulus and tensile strength significantly increased with age; the rates of their increases between 1 and 2 months were higher than those between 2 and 6 months. The tangent modulus and tensile strength were positively correlated with the body weight of animals. However, growth-related changes in the mechanical properties were different between collagen fascicles and bulk patellar tendons, which may be attributable to such non-collagenous components as ground substances and also to mechanical interactions between collagen fascicles.  相似文献   

12.
Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.  相似文献   

13.
Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n = 5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon, and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young's modulus was 2.0 ± 0.5 GPa, and the toe region reached 3.3 ± 1.9% strain in whole patellar tendons. Based on dry cross-sectional area, the Young's modulus of isolated collagen fibrils was 2.8 ± 0.3 GPa, and the toe region reached 0.86 ± 0.08% strain. The measured fibril modulus was insufficient to account for the modulus of the tendon in vivo when fibril content in the tendon was accounted for. Thus, our original hypothesis was not supported, although the in vitro fibril modulus corresponded well with reported in vitro tendon values. This correspondence together with the fibril modulus not being greater than that of tendon supports that fibrillar rather than interfibrillar properties govern the subfailure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition to the primary work comparing the two hierarchical levels, we also verified the existence of viscoelastic behavior in isolated human collagen fibrils.  相似文献   

14.
Small sinusoidal vibrations at 300 HZ were applied to frog sartorius muscle to measure the dynamic stiffness (Young's modulus) throughout the course of tetanus. For a peak-to-peak amplitude of 0.4% the dynamic Young's modulus increased from 1.5 X 10(5) Nm-2 in the resting state to 2 X 10(7) Nm-2 in tetanus. After correction for the external connective tissue, the dynamic Young's modulus of the muscle was almost directly proportional to the tension throughout the development of tetanus. The ratio of dynamic Young's modulus to tensile stress thus remained constant (with a value at 300 Hz of approximately 100), consistently with Huxley and Simmon's identification of the crossbridges as the source of both tension and stiffness. For a single crossbridge the ratio of stiffness to tension was 8.2 X 10(7) m-1 at 300 Hz; it is deduced from literature data that the limiting value at high frequencies is about 1.6 X 10(8) m-1. This ratio is interpreted on Harrington's (1971) model to show that crossbridge action can be explained by a helix-coil transition of about 80 out of the 260 residues in each S-2 myosin strand. It is also shown that a helix-coil model can account for the observed rapid relaxation of muscle without invoking any complex behaviour of the crossbridge head.  相似文献   

15.
BACKGROUND: Experiments on the fatigue of tendons have shown that cyclic loading induces failure at stresses lower than the ultimate tensile strength (UTS) of the tendons. The number of cycles to failure (Nf) has been shown to be dependent upon the magnitude of the applied cyclic stress. METHOD OF APPROACH: Utilizing data collected by Schechtman (1995), we demonstrate that the principles of Linear Elastic Fracture Mechanics (LEFM) can be used to predict the fatigue behavior of tendons under cyclic loading for maximum stress levels that are higher than 10% of the ultimate tensile strength (UTS) of the tendon (the experimental results at 10% UTS did not fit with our equations). CONCLUSIONS: LEFM and other FM approaches may prove to be very valuable in advancing our understanding of damage accumulation in soft connective tissues.  相似文献   

16.
The purpose of this study was to determine the effect of Haversian remodeling on the tensile properties of human cortical bone by testing specimens containing, as far a possible, a single type of bone tissue. Fifty-one specimens were prepared from sixteen fresh tibias, removed at autopsy. Age range was 19-35. Regions were selected so that the specimens would consist almost exclusively of either primary bone or Haversian bone. The ultimate tensile strength, ultimate strain and Young's modulus of elasticity were determined at a loading rate of 0.05 mm s-1. The primary bone specimens were found to have a significantly higher ultimate tensile strength and modulus of elasticity than those formed of Haversian bone.  相似文献   

17.
Gamma irradiation is a proven sterilization method, but is not widely used on allografts for anterior cruciate ligament reconstruction (e.g., patella tendon) due to radiation-induced decreases in mechanical strength. Addressing this drawback would improve the safety and supply of allografts to meet current and future demand. It was hypothesized that genipin-induced collagen cross-linking would increase the tensile modulus of patella tendon tissue such that 5 MRad gamma irradiation would not reduce the tissue mechanical strength below the original untreated values. Optimized genipin treatment increased the tensile modulus of bovine tendons by ~2.4-fold. After irradiation, genipin treated tissue did not significantly differ from native tissue, proving the hypothesis. Optimized genipin treatment of human tendons increased the tensile modulus by ~1.3-fold. After irradiation, both control and genipin-treated tissues possessed ~50–60% of their native tendon modulus, disproving the hypothesis. These results highlight possible age- and species- dependent effects of genipin cross-linking on tendon tissue. Cross-linking of human allografts may be beneficial only in younger donor tissues. Future research is warranted to better understand the mechanisms and applications of collagen cross-linking for clinical use.  相似文献   

18.
Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The purpose of this study was to use imaging techniques to measure the strains around the circumference of 11 mm wide Achilles tendon grafts during a uniaxial tensile test. Pairs of radiopaque beads with a diameter of 2mm were affixed around the mid-substance of the tendon in four different locations. The motion of the beads was recorded using a cine fluoroscope. This system was shown to measure the displacement of the beads with an accuracy of 0.02 mm. During the uniaxial tensile test, large variations in local tissue strains were observed. At 10 MPa of applied stress, the local tissue strain varied from an average of 2.5-8.7%, an increase in strain of more than three times. As a result of these large variations, the modulus calculated from the stress-strain data varied from an average of 217 to 897 MPa, an increase of approximately 4 times. Furthermore, these data suggest that underestimates of the elastic modulus may result if a uniform strain distribution is assumed. These results indicate that during uniaxial tensile tests, the assumption of uniform stress and strain distributions should be carefully considered and small, uniform specimens should be used when measuring the material properties of soft tissues.  相似文献   

19.
Rats use specialized tactile hairs on their snout, called vibrissae (whiskers), to explore their surroundings. Vibrissae have no sensors along their length, but instead transmit mechanical information to receptors embedded in the follicle at the vibrissa base. The transmission of mechanical information along the vibrissa, and thus the tactile information ultimately received by the nervous system, depends critically on the mechanical properties of the vibrissa. In particular, transmission depends on the bending stiffness of the vibrissa, defined as the product of the area moment of inertia and Young's modulus. To date, Young's modulus of the rat vibrissa has not been measured in a uniaxial tensile test. We performed tensile tests on 22 vibrissae cut into two halves: a tip-segment and a base-segment. The average Young's modulus across all segments was 3.34±1.48GPa. The average modulus of a tip-segment was 3.96±1.60GPa, and the average modulus of a base-segment was 2.90±1.25GPa. Thus, on average, tip-segments had a higher Young's modulus than base-segments. High-resolution images of vibrissae were taken to seek structural correlates of this trend. The fraction of the cross-sectional area occupied by the vibrissa cuticle was found to increase along the vibrissa length, and may be responsible for the increase in Young's modulus near the tip.  相似文献   

20.
Cellular responses to mechanical stimuli are regulated by interactions with the extracellular matrix, which, in turn, are strongly influenced by the degree of cell stiffness (Young's modulus). It was hypothesized that a more elastic cell could better withstand the rigors of remodeling and mechanical loading. It was further hypothesized that interleukin-1beta (IL-1beta) would modulate intracellular cytoskeleton polymerization and regulate cell stiffness. The purpose of this study was to investigate the utility of IL-1beta to alter the Young's modulus of human tenocytes. Young's modulus is the ratio of the stress to the strain, E = stress/strain = (F/A)/(deltaL/L0), where L0 is the equilibrium length, deltaL is the length change under the applied stress, F is the force applied, and A is the area over which the force is applied. Human tenocytes were incubated with 100 pM recombinant human IL-1beta for 5 days. The Young's modulus was reduced by 27-63%. Actin filaments were disrupted in >75% of IL-1beta-treated cells, resulting in a stellate shape. In contrast, immunostaining of alpha-tubulin showed increased intensity in IL-1beta-treated tenocytes. Human tenocytes in IL-1beta-treated bioartificial tendons were more tolerant to mechanical loading than were untreated counterparts. These results indicate that IL-1beta reduced the Young's modulus of human tenocytes by disrupting the cytoskeleton and/or downregulating the expression of actin and upregulating the expression of tubulins. The reduction in cell modulus may help cells to survive excessive mechanical loading that may occur in damaged or healing tendons.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号