首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Legionella pneumophila is a waterborne pathogen that has been isolated sporadically from drinking water distribution systems (DWDS). Resistance to disinfectants is mainly attributed to the association of cells with amoebae, but biofilms are also thought to provide some degree of protection. In the present work, a two-stage chemostat was used to form heterotrophic biofilms from drinking water to study the influence of chlorine on the presence of naturally occurring L. pneumophila. The pathogen was tracked in planktonic and sessile biofilm phases using standard culture recovery techniques for cultivable cells and a peptide nucleic acid fluorescence in situ hybridisation assay for total cells. The results showed that the total number of L. pneumophila cells in biofilms was not affected by the concentrations of chlorine tested, and the presence of L. pneumophila could not be detected by culturing. To restrict the outbreaks of disease caused by this bacterium, efforts need to be concentrated on preventing L. pneumophila from re-entering an infectious state by maintaining residual disinfectant levels through the entire DWDS network so that the resuscitation of cells via contact with amoebae is prevented.  相似文献   

2.
Using fluorescence in situ hybridization to detect bacterial groups has several inherent limitations. DNA probes are generally used, targeting sites on the 16S rRNA. However, much of the 16S rRNA is highly conserved, with variable regions often located in inaccessible areas where secondary structures can restrict probe access. Here, we describe the use of peptide nucleic acid (PNA) probes as a superior alternative to DNA probes, especially when used for environmental samples. A complex bacterial genus (Legionella) was studied, and two probes were designed, one to detect all species and one targeted to Legionella pneumophila. These probes were developed from existing sequences and are targeted to low-binding-affinity sites on the 16S rRNA. In total, 47 strains of Legionella were tested. In all cases, the Legionella spp. PNA probe labeled cells strongly but did not bind to any non-Legionella species. Likewise, the specific L. pneumophila PNA probe labeled only strains of L. pneumophila. By contrast, the equivalent DNA probes performed poorly. To assess the applicability of this method for use on environmental samples, drinking-water biofilms were spiked with a known concentration of L. pneumophila bacteria. Quantifications of the L. pneumophila bacteria were compared using PNA hybridization and standard culture methods. The culture method quantified only 10% of the number of L. pneumophila bacteria found by PNA hybridization. This illustrates the value of this method for use on complex environmental samples, especially where cells may be in a viable but noncultivable state.  相似文献   

3.
The aim of this study was to compare the occurrence of L. pneumophila in hot water samples from hot water tanks and instantaneous devices. Tanks and devices were all operated by heat exchangers employed in the town's district heating system. Thirty-six out of 171 (21%) hot water samples tested positive for L. pneumophila isolation, with 14.6% belonging to serogroup 1 and 6.4% to serogroups 2–14. The proportion of L. pneumophila detected in hot water reservoirs (30%) was higher than that observed in hot water instantaneous devices (6.2%). Differences in L. pneumophila isolation reflected different temperatures registered at the faucet: ≤50°C for hot water from reservoir devices, and >60°C for hot water from instantaneous devices. These data emphasize the need to control temperature in hot water distribution devices, thus inhibiting the formation of biofilm and L. pneumophila colonization. Received: 4 April 2000 / Accepted: 31 May 2000  相似文献   

4.
Legionella pneumophila, the aetiological agent of 90% of legionellosis cases, is a common inhabitant of natural and anthropogenic freshwater environments, where it resides in biofilms. Biofilms are defined as complex, natural assemblages of microorganisms that involve a multitude of trophic interactions. A thorough knowledge and understanding of Legionella ecology in relation to biofilm communities is of primary importance in the search for innovative and effective control strategies to prevent the occurrence of disease cases. This review provides a critical update on the state‐of‐the‐art progress in understanding the mechanisms and factors affecting the biofilm life cycle of L. pneumophila. Particular emphasis is given to discussing the different strategies this human pathogen uses to grow and retain itself in biofilm communities. Biofilms develop not only at solid‐water interfaces (substrate‐associated biofilms), but also at the water‐air interface (floating biofilms). Disturbance of the water surface can lead to liberation of aerosols derived from the floating biofilm into the atmosphere that allow transmission of biofilm‐associated pathogens over considerable distances. Recent data concerning the occurrence and replication of L. pneumophila in floating biofilms are also elaborated and discussed.  相似文献   

5.
Sterilization values were determined forLegionella pneumophila in chlorine-free, chlorine-demand-free water at elevated temperatures. These values were calculated from experimentally determined D values of 2500 min, 380 min, 13.93 min, 0.74 min, and 0.45 min at 45°C, 50°C, 55°C, 60°C, and 66°C, respectively. D values, Z value and temperature coefficient do not indicate unusual thermal resistance. Sterilization values, the minimum time required to eliminate an aquatic population ofL. pneumophila at a given test temperature, indicate that temperatures greater than about 65°C may not be necessary for efficient disinfection of potable quality water. These values and monitoring of time and temperature parameters can help predict the efficacy of in situ heat treatment of potable quality waters harboringL. pneumophila.  相似文献   

6.
Aims: This study was designed to evaluate the usefulness of quantification by real‐time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90‐431). Methods and Results: Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 105 GU l?1) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57–100% of the samples. Conclusions: These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real‐time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. Significance and Impact of the Study: This study shows the possibility of using real‐time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters.  相似文献   

7.
Currently, models for studying Legionella pneumophila biofilm formation rely on multi-species biofilms with low reproducibility or on growth in rich medium, where planktonic growth is unavoidable. The present study describes a new medium adapted to the growth of L. pneumophila monospecies biofilms in vitro. A microplate model was used to test several media. After incubation for 6 days in a specific biofilm broth not supporting planktonic growth, biofilms consisted of 5.36 ± 0.40 log (cfu cm?2) or 5.34 ± 0.33 log (gu cm?2). The adhered population remained stable for up to 3 weeks after initial inoculation. In situ confocal microscope observations revealed a typical biofilm structure, comprising cell clusters ranging up to ~300 μm in height. This model is adapted to growing monospecies L. pneumophila biofilms that are structurally different from biofilms formed in a rich medium. High reproducibility and the absence of other microbial species make this model useful for studying genes involved in biofilm formation.  相似文献   

8.
Biofilms are a major source of human pathogenic Legionella pneumophila in aquatic systems. In this study, we investigated the capacity of L. pneumophila to colonize floating biofilms and the impact of Acanthamoeba castellanii on the replication of biofilm-associated Legionella. Biofilms were grown in Petri dishes and consisted of Aeromonas hydrophila, Escherichia coli, Flavobacterium breve, and Pseudomonas aeruginosa. Six hours following inoculation, Legionella were detected in floating biofilms in mean concentrations of 1.4 × 104 cells/cm2 (real-time polymerase chain reaction) and 8.3 × 102 CFU/cm2 (culture). Two-way analysis of variance tests and fluorescent in situ hybridization clearly proved that increased biofilm-associated L. pneumophila concentrations were the result of intracellular replication in A. castellanii. Forty-eight hours after the introduction of A. castellanii in the Petri dishes, 90 ± 0.8% of the amoebae (infection rate) were completely filled with highly metabolic active L. pneumophila (mean infection intensity).  相似文献   

9.
Listeria monocytogenes is a typical foodborne pathogen that causes hard-to-treat bacterial infections, mainly due to its ability to form biofilm and enter into a viable but non-culturable state (VBNC). In this study, we investigated the removal effects of four antimicrobial agents on L. monocytogenes biofilms formed at 32°C and 10°C, analysed the resistances of the mature biofilms to antimicrobial agents, and explored the VBNC state of cells in mature biofilms induced by lavender essential oil (LEO). The results showed that the growth of L. monocytogenes was completely inhibited when 1·6% (v/v) of the LEO was added. Meanwhile, the results of the crystal violet staining and XTT reduction method indicated that different concentrations of LEO significantly reduced L. monocytogenes biofilms biomass and metabolic activities, followed by sodium hypochlorite, lactic acid, and hydrogen peroxide. Moreover, the confocal laser scanning microscopy (CLSM) images confirmed that the treated biofilms became thinner, the structure was sparse, and the appearance was blurry. More interestingly, L. monocytogenes biofilms developed at 10°C were less susceptible to the sanitizers than those formed at 32°C. In addition, LEO presented a more significant dispersing effect on the biofilm cells, and 1/2 MIC to 4 MIC of LEO could induce fewer VBNC state cells in biofilm and plankton compared with sodium hypochlorite. This study indicated that the LEO could be considered as an ideal antibiofilm agent for controlling L. monocytogenes. But we should pay attention to the resistance of the biofilms developed at low temperatures.  相似文献   

10.
Legionella pneumophila serogroup 1 causes Legionnaires'' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires'' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot springs, and potable water systems were divided into 25 sequence types (STs; index of discrimination [IOD], 0.711), 19 STs (IOD, 0.934), and 3 STs (IOD, 0.151), respectively. The genetic variation among the potable water isolates was lower than that among cooling tower and hot spring isolates. ST1 was the predominant type, accounting for 49.4% of analyzed strains (n = 81), followed by ST154. With the exception of two strains, all potable water isolates (92.3%) belonged to ST1. In contrast, 53.1% (51/96) and only 14.3% (6/42) of cooling tower and hot spring, respectively, isolates belonged to ST1. There were differences in the distributions of clone groups among the water sources. The comparisons among L. pneumophila strains isolated in China, Japan, and South Korea revealed that similar clones (ST1 complex and ST154 complex) exist in these countries. In conclusion, in China, STs had several unique allelic profiles, and ST1 was the most prevalent sequence type of environmental L. pneumophila serogroup 1 isolates, similar to its prevalence in Japan and South Korea.  相似文献   

11.

Background  

It is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission remains unknown but water seems to play an important role. This work aims to study the influence of five microorganisms isolated from drinking water biofilms on the survival and integration of both of these pathogens into biofilms.  相似文献   

12.
Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic‐associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS‐culture and standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS‐culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.  相似文献   

13.
A two-stage chemostat model of a plumbing system was developed, with tap water as the sole nutrient source. The model system was populated with a naturally occurring inoculum derived from an outbreak of Legionnaires' disease and containing Legionella pneumophila along with associated bacteria and protozoa. The model system was used to develop biofilms on the surfaces of a range of eight plumbing materials under controlled, reproducible conditions. The materials varied in their abilities to support biofilm development and the growth of L. pneumophila. Elastomeric surfaces had the most abundant biofilms supporting the highest numbers of L. pneumophila CFU; this was attributed to the leaching of nutrients for bacterial growth from the materials. No direct relationship existed between total biofouling and the numbers of L. pneumophila CFU.  相似文献   

14.
Legionella pneumophila is accounted for more than 80% of Legionella infection. However it is difficult to discriminate between the L. pneumophila and non-L. pneumophila species rapidly. In order to detect the Legionella spp. and distinguish L. pneumophila from Legionella spp., a real-time loop-mediated isothermal amplification (LAMP) platform that targets a specific sequence of the 16S rRNA gene was developed. LS-LAMP amplifies the fragment of the 16S rRNA gene to detect all species of Legionella genus. A specific sequence appears at the 16S rRNA gene of L. pneumophila, while non-L. pneumophila strains have a variable sequence in this site, which can be recognized by the primer of LP-LAMP. In the present study, 61 reference strains were used for the method verification. We found that the specificity was 100% for both LS-LAMP and LP-LAMP, and the sensitivity of LAMP assay for L. pneumophila detection was between 52 and 5.2 copies per reaction. In the environmental water samples detection, a total of 107 water samples were identified by the method. The culture and serological test were used as reference methods. The specificity of LS-LAMP and LP-LAMP for the samples detection were 91.59% (98/107) and 93.33% (56/60), respectively. The sensitivity of LS-LAMP and LP-LAMP were 100% (51/51) and 100% (18/18). The results suggest that real-time LAMP, as a new assay, provides a specific and sensitive method for rapid detection and differentiation of Legionella spp. and L. pneumophila and should be utilized to test environmental water samples for increased rates of detection.  相似文献   

15.
A total of 25 gyrB gene sequences from 20 Legionella pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were obtained and analyzed, and a multiplex PCR for the simultaneous detection of Legionella bozemanae, Legionella longbeachae, Legionella micdadei and Legioenella pneumophila, and two single PCRs for the differentiation of L. pneumophila subsp. pneumophila and L. pneumophila subsp. fraseri were established. The multiplex PCR method was shown to be highly specific and reproducible when tested against 41 target strains and 17 strains of other bacteria species. The sensitivity of the multiplex PCR was also analyzed and was shown to detect levels as low as 1 ng of genomic DNA or 10 colony-forming units (CFUs) per milliliter in mock water samples. Sixty-three air conditioner condensed water samples from Shanghai City were examined, and the result was validated using 16S rRNA sequencing. The data reported here demonstrate that the multiplex PCR method described is efficient and convenient for the detection of Legionella species in water samples. Twenty L. pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were used for the validation of the two L. pneumophila subspecies-specific PCR methods, and the results indicated that the two PCR methods were both highly specific and convenient for the identification of L. pneumophila at the subspecies level.  相似文献   

16.
Legionella pneumophila, the agent of Legionnaires'' disease pneumonia, is transmitted to humans following the inhalation of contaminated water droplets. In aquatic systems, L. pneumophila survives much of time within multi-organismal biofilms. Therefore, we examined the ability of L. pneumophila (clinical isolate 130b) to persist within biofilms formed by various types of aquatic bacteria, using a bioreactor with flow, steel surfaces, and low-nutrient conditions. L. pneumophila was able to intercalate into and persist within a biofilm formed by Klebsiella pneumoniae, Flavobacterium sp. or Pseudomonas fluorescens. The levels of L. pneumophila within these biofilms were as much as 4×104 CFU per cm2 of steel coupon and lasted for at least 12 days. These data document that K. pneumoniae, Flavobacterium sp., and P. fluorescens can promote the presence of L. pneumophila in dynamic biofilms. In contrast to these results, L. pneumophila 130b did not persist within a biofilm formed by Pseudomonas aeruginosa, confirming that some bacteria are permissive for Legionella colonization whereas others are antagonistic. In addition to colonizing certain mono-species biofilms, L. pneumophila 130b persisted within a two-species biofilm formed by K. pneumoniae and Flavobacterium sp. Interestingly, the legionellae were also able to colonize a two-species biofilm formed by K. pneumoniae and P. aeruginosa, demonstrating that a species that is permissive for L. pneumophila can override the inhibitory effect(s) of a non-permissive species.  相似文献   

17.
Aims: Open cooling towers are frequent sources of infections with Legionella pneumophila. The gold standard for the detection of Leg. pneumophila is based on cultivation lasting up to 10 days and detecting only culturable cells. Alternative fluorescence in situ hybridization (FISH) protocols have been proposed, but they result in faint fluorescence signals and lack specificity because of cross‐hybridization with other Legionella species. Our aim was thus to develop a new FISH protocol for rapid and specific detection of Leg. pneumophila in water samples. Methods and Results: A novel catalysed reporter deposition FISH (CARD‐FISH) protocol for the detection of Leg. pneumophila was developed, which significantly enhanced signal intensity as well as specificity of the probe through the use of a novel competitor probe. The developed protocol was compared with the culture method for monitoring the seasonal development of culturable and nonculturable Leg. pneumophila in two hospital cooling tower systems. Seasonal fluctuations of Leg. pneumophila concentrations detected via CARD‐FISH were related to the development of the total bacterial community in both cooling towers, with temperature and biocide as the main factors controlling this development. Conclusions: Our results clearly showed that the majority of the Leg. pneumophila cells were in a nonculturable state. Thus, detection of Leg. pneumophila with culture methods may underestimate the total numbers of Leg. pneumophila present. Significance and Impact of the Study: Rapid, sensitive and specific detection and quantification of Leg. pneumophila in water systems is prerequisite for reliable risk estimation. The new protocol significantly improves current methodology and can be used to monitor and screen for Leg. pneumophila concentrations in cooling towers or other water systems.  相似文献   

18.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

19.
The oomycete Leptolegnia chapmanii is among the most promising entomopathogens for biological control of Aedes aegypti. This mosquito vector breeds in small water collections, where this aquatic watermold pathogen can face short-term scenarios of challenging high or low temperatures during changing ambient conditions, but it is yet not well understood how extreme temperatures might affect the virulence and recycling capacities of this pathogen. We tested the effect of short-term exposure of encysted L. chapmanii zoospores (cysts) on A. aegypti larvae killed after infection by this pathogen to stressful low or high temperatures on virulence and production of cysts and oogonia, respectively. Cysts were exposed to temperature regimes between ?12 °C and 40 °C for 4, 6 or 8 h, and then their infectivity was tested against third instar larvae (L3) at 25 °C; in addition, production of cysts and oogonia on L3 killed by infection exposed to the same temperature regimes as well as their larvicidal activity were monitored. Virulence of cysts to larvae and the degree of zoosporogenesis on dead larvae under laboratory conditions were highest at 25 °C but were hampered or even blocked after 4 up to 8 h exposure of cysts or dead larvae at both the highest (35 °C and 40 °C) and the lowest (?12 °C) temperatures followed by subsequent incubation at 25 °C. The virulence of cysts was less affected by accelerated than by slow thawing from the frozen state. The production of oogonia on dead larvae was stimulated by short-term exposure to freezing temperatures (?12 °C and 0 °C) or cool temperatures (5 °C and 10 °C) but was not detected at higher temperatures (25 °C–40 °C). These findings emphasize the susceptibility of L. chapmanii to short-term temperature stresses and underscore its interest as an agent for biocontrol of mosquitoes in the tropics and subtropics, especially A. aegypti, that breed preferentially in small volumes of water that are generally protected from direct sunlight.  相似文献   

20.
Listeria monocytogenes is a foodborne pathogen that can be transmitted through contaminated raw food or by ready-to-eat products that have been in contact with contaminated surfaces. Tap water (TW) is used to wash produce, as a processed food constituent and to wash processing surfaces and floors. The main aim of this work was to investigate the formation and survival of L. monocytogenes biofilms on stainless steel (SS) coupons in TW at 4, 22, 30 and 37 °C. For that, coupons with biofilm were visualised in situ while other coupons were scraped to quantify total cells by SYTO 9, cultivable numbers by plating onto brain heart infusion agar and viable numbers by the direct viable count method. Results showed that L. monocytogenes can form biofilms on SS surfaces in TW at any temperature, including at 4 °C. The number of total cells was similar for all the conditions tested while cultivable numbers varied between the level of detection (<8.3 CFU cm?2) and 3.5?×?105 CFU cm?2, meaning between 7.0?×?104 and 1.1?×?107 cells cm?2 have entered the viable but non-cultivable (VBNC) state. This work clearly demonstrates that L. monocytogenes can form biofilms in TW and that sessile cells can remain viable and cultivable in some conditions for at least the 48 h investigated. On the other hand, VBNC adaptation suggests that the pathogen can remain undetectable using traditional culture recovery techniques, which may give a false indication of processing surface hygiene status, leading to potential cross-contamination of food products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号