首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The most commonly used method for protein identification with two-dimensional (2D) online liquid chromatography-mass spectrometry (LC/MS) involves the elution of digest peptides from a strong cation exchange column by an injected salt step gradient of increasing salt concentration followed by reversed phase separation. However, in this approach ion exchange chromatography does not perform to its fullest extent, primarily because the injected volume of salt solution is not optimized to the SCX column. To improve the performance of strong cation exchange chromatography, we developed a new method for 2D online nano-LC/MS that replaces the injected salt step gradient with an optimized semicontinuous pumped salt gradient. The viability of this method is demonstrated in the results of a comparative analysis of a complex tryptic digest of the yeast proteome using the injected salt solution method and the semicontinuous pump salt method. The semicontinuous pump salt method compares favorably with the commonly used injection method and also with an offline 2D-LC method.  相似文献   

2.
The 2‐D peptide separations employing mixed mode reversed phase anion exchange (MM (RP‐AX)) HPLC in the first dimension in conjunction with RP chromatography in the second dimension were developed and utilised for shotgun proteome analysis. Compared with strong cation exchange (SCX) typically employed for shotgun proteomic analysis, peptide separations using MM (RP‐AX) revealed improved separation efficiency and increased peptide distribution across the elution gradient. In addition, improved sample handling, with no significant reduction in the orthogonality of the peptide separations was observed. The shotgun proteomic analysis of a mammalian nuclear cell lysate revealed additional proteome coverage (2818 versus 1125 unique peptides and 602 versus 238 proteins) using the MM (RP‐AX) compared with the traditional SCX hyphenated to RP‐LC‐MS/MS. The MM analysis resulted in approximately 90% of the unique peptides identified present in only one fraction, with a heterogeneous peptide distribution across all fractions. No clustering of the predominant peptide charge states was observed during the gradient elution. The application of MM (RP‐AX) for 2‐D LC proteomic studies was also extended in the analysis of iTRAQ‐labelled HeLa and cyanobacterial proteomes using nano‐flow chromatography interfaced to the MS/MS. We demonstrate MM (RP‐AX) HPLC as an alternative approach for shotgun proteomic studies that offers significant advantages over traditional SCX peptide separations.  相似文献   

3.
The sensitivity of proteomics measurements using liquid chromatography (LC) separations interfaced with electrospray ionization-mass spectrometry (ESI-MS) improves approximately inversely with liquid flow rate (for the columns having the same separation efficiency, linear velocity, and porosity), making attractive the use of smaller inner diameter LC columns. We report the development and initial application of 10 microm i.d. silica-based monolithic LC columns providing more sensitive proteomics measurements. A 50-microm-i.d. micro solid-phase extraction precolumn was used for ease of sample injection and cleanup prior to the reversed-phase LC separation, enabling the sample volume loading speed to be increased by approximately 50-fold. Greater than 10-fold improvement in sensitivity was obtained compared to analyses using more conventional capillary LC, enabling e.g. the identification of >5000 different peptides by MS/MS from 100-ng of a Shewanella oneidensis tryptic digest using an ion trap MS. The low nL/min LC flow rates provide more uniform responses for different peptides, and provided improved quantitative measurements compared to conventional separation systems without the use of internal standards or isotopic labeling. The improved sensitivity allowed LC-MS measurements of immunopurified protein phosphatase 5 that were in good agreement with quantitative Western blot analyses.  相似文献   

4.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

5.
A high-throughput on-line capillary array-based two-dimensional liquid chromatography (2D-LC) system coupled with MALDI-TOF-TOF-MS proteomics analyzer for comprehensive proteomic analyses has been developed, in which one capillary strong-cation exchange (SCX) chromatographic column was used as the first separation dimension and 18 parallel capillary reversed-phase liquid chromatographic (RPLC) columns were integrated as the second separation dimension. Peptides bound to the SCX phase were "stepped" off using multiple salt pulses followed by sequentially loading of each subset of peptides onto the corresponding precolumns. After salt fractionation, by directing identically split solvent-gradient flows into 18 channels, peptide fractions were concurrently back-flushed from the precolumns and separated simultaneously with 18 capillary RP columns. LC effluents were directly deposited onto the MALDI target plates through an array of capillary tips at a 15-s interval, and then alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix solution was added to each sample spot for subsequent MALDI experiments. This new system allows an 18-fold increase in throughput compared with serial-based 2D-LC system. The high efficiency of the overall system was demonstrated by the analysis of a tryptic digest of proteins extracted from normal human liver tissue. A total of 462 proteins was identified, which proved the system's promising potential for high-throughput analysis and application in proteomics.  相似文献   

6.
Evaluation of cellular processes and their changes at the level of protein expression and post-translational modifications may allow identification of novel proteins and the mechanisms involved in pathogenic processes. However, the number of proteins and, after tryptic digestion, of peptides from a single cell can be tremendously high. Separation and analysis of such complex peptide mixtures can be performed using multidimensional separation techniques such as two-dimensional gel electrophoresis or two-dimensional-high-performance liquid chromatography (2-D-HPLC). The aim of this work was to establish a fully automated on-line 2-D-HPLC separation method with column switching for the separation of complex tryptic digests. A model mixture of five proteins as well as a nuclear matrix protein sample were digested with trypsin and separated using a strong cation exchange (SCX) column in the first dimension and nano reversed phase in the second dimension. Separated peptides were detected using an ion trap mass spectrometer. The advantages of this new fully automated method are rapid sample loading, the possibility of injecting large volumes and no introduction of salt into the mass spectrometer. Furthermore, column switching allows the independent control and optimization of the two dimensions independently.  相似文献   

7.
A two-dimensional separation scheme for shotgun proteome analysis employing high-pH reversed-phase HPLC in the first and low-pH ion-pair reversed-phase HPLC in the second dimension (RP x IP-RP-HPLC) has been developed and evaluated. Compared to the classical strong cation exchange x ion-pair reversed-phase (SCX x IP-RP-HPLC) approach, the RP x IP-RP-HPLC system was characterized by a lower degree of orthogonality, which was, however, more than counterbalanced by higher separation efficiency, more homogeneous distribution of peptide elution, and easier experimental handling. Peptide fragment fingerprinting by electrospray-ionization tandem mass spectrometry (ESI-MS/MS) was employed for peptide detection and identification. About 13% more peptides and 7% more proteins could be identified with the alternative approach in 30% less analysis time, enabling the analysis of the proteome of Corynebacterium glutamicum with a coverage of 24.9% (745 proteins). Combining the identification results both of the SCX- x IP-RP-HPLC-ESI-MS/MS and RP- x IP-RP-HPLC-ESI-MS/MS methods, a total of 871 proteins were identified in a cytosolic protein preparation, which represented 29.1% of all proteins annotated in the genome of C. glutamicum.  相似文献   

8.
Haloferax volcanii, an extreme halophile originally isolated from the Dead Sea, is used worldwide as a model organism for furthering our understanding of archaeal cell physiology. In this study, a combination of approaches was used to identify a total of 1296 proteins, representing 32% of the theoretical proteome of this haloarchaeon. This included separation of (phospho)proteins/peptides by 2-dimensional gel electrophoresis (2-D), immobilized metal affinity chromatography (IMAC), metal oxide affinity chromatography (MOAC), and Multidimensional Protein Identification Technology (MudPIT) including strong cation exchange (SCX) chromatography coupled with reversed phase (RP) HPLC. Proteins were identified by tandem mass spectrometry (MS/MS) using nanoelectrospray ionization hybrid quadrupole time-of-flight (QSTAR XL Hybrid LC/MS/MS System) and quadrupole ion trap (Thermo LCQ Deca). Results indicate that a SCX RP HPLC fractionation coupled with MS/MS provides the best high-throughput workflow for overall protein identification.  相似文献   

9.
A simple and fast screening method for the selection of fractions of first dimension separation to be analyzed in second dimension‐MS/MS experiments in offline multidimensional liquid chromatographic separation schemes for shotgun proteome analysis was developed. The method is based on the measurement of total peptide content of the first dimension fractions by MALDI MS and was established using a tryptic digest of a bacterial proteome. The results of the screening process were in good agreement with those obtained in a detailed proteome analysis performed by RP×ion‐pair RP‐MALDI TOF/TOF MS analysis. The method supports a straightforward planning of experiments, also enabling a reduction of overall measurement time in shotgun proteome analysis.  相似文献   

10.
A rugged, reproducible, multi-dimensional LC-MS system was developed to identify and characterize proteins involved in protein-protein interactions and/or protein complexes. Our objective was to optimize chromatographic parameters for complex protein mixture analyses using automated peptide sequence recognition as an analytical end-point. The chromatographic system uses orthogonal separation mechanisms by employing strong cation exchange (SCX) in the first dimension and reversed phase (RP) in the second dimension. The system is fully automated and sufficiently robust to handle direct injections of protein digests. This system incorporates a streamlined post analysis results comparison, called DBParser, which permitted comprehensive evaluation of sample loading and chromatographic conditions to optimize the performance and reproducibility. Peptides obtained from trypsin digestion of a yeast soluble extract provided an open-ended model system containing a wide variety and dynamic range of components. Conditions are described that resulted in an average (n = 4) of 1489 unique peptide identifications, corresponding to 459 non-redundant protein sequence database records (SDRs) in the 20 microg soluble fraction digest.  相似文献   

11.
12.
Analysis of human liver proteome using replicate shotgun strategy   总被引:4,自引:0,他引:4  
Chen M  Ying W  Song Y  Liu X  Yang B  Wu S  Jiang Y  Cai Y  He F  Qian X 《Proteomics》2007,7(14):2479-2488
In this study, a liquid-based shotgun strategy was used to comprehensively identify the expression of human liver proteome. Proteins were extracted from human liver tissue and digested in-solution. The tryptic digest mixture was desalted and separated by off-line strong cation exchange (SCX) chromatography with a 60-min elution. The MS/MS spectra were acquired in data-dependent mode after an RP chromatographic separation combined with linear IT MS analysis. To obtain the most comprehensive human liver proteome, each SCX fraction was run six times in RPLC MS/MS manner. Finally, more than 6,000,000 MS/MS spectra were collected. Using a relatively strict filter criteria, 24,311 proteins (48.42% of the predicted human proteome from human International Protein Index (IPI) protein database 3.07) corresponding to 13,150 nonredundant proteins were successfully identified, in which 7001 proteins (53.24%) were identified by two or more peptides, which could be considered as a high-confident dataset. Among the 6149 proteins (46.76%) identified by single peptide, 3812 proteins (61.99%) were detected more than twice in six repeated runs. Comparative analysis between different runs shows that the overlap of identified proteins between any two runs ranged from 25 to 44%. Of the nonredundant proteins identified, 8919 proteins (67.83%) were detected more than twice and 4231 proteins (32.17%) were detected only once in six RPLC MS/MS runs. The Gene Ontology annotation shows that the identified proteins come from various subcellular components. In addition, a large number of low abundant proteins were identified. The dynamic range of the approach reached at least nine orders of magnitude by estimating the concentration of proteins.  相似文献   

13.
Capillary column immobilised metal affinity chromatography (IMAC) has been combined on-line with electrospray ionisation/quadrupole time-of-flight mass spectrometry for the fractionation of histidine-containing peptides. IMAC beads (Poros 20MC, 20 microm) containing imidodiacetate chelating groups on a cross-linked poly(styrene-divinylbenzene) support were packed into a fused silica column (250 microm i.d.), which was interfaced to the electrospray ion source of the spectrometer. A Cu(II) activated column was used to isolate histidine-containing peptides from tryptic and other peptide mixtures with an average breakthrough of 9.1%, to reduce the complexity of the mass spectral analysis. The analysis cycle time was reduced to less than 15 min, at an optimum flow rate of 7.5 microL/min, without sacrificing peptide selectivity. Direct coupling of capillary IMAC with MS allows on-line separation, using MS compatible loading and elution buffers, and detection in a high-throughput fashion when compared to off-line strategies.  相似文献   

14.
Highly complex protein mixtures can be directly analyzed after proteolysis by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). In this paper, we have utilized the combination of strong cation exchange (SCX) and reversed-phase (RP) chromatography to achieve two-dimensional separation prior to MS/MS. One milligram of whole yeast protein was proteolyzed and separated by SCX chromatography (2.1 mm i.d.) with fraction collection every minute during an 80-min elution. Eighty fractions were reduced in volume and then re-injected via an autosampler in an automated fashion using a vented-column (100 microm i.d.) approach for RP-LC-MS/MS analysis. More than 162,000 MS/MS spectra were collected with 26,815 matched to yeast peptides (7,537 unique peptides). A total of 1,504 yeast proteins were unambiguously identified in this single analysis. We present a comparison of this experiment with a previously published yeast proteome analysis by Yates and colleagues (Washburn, M. P.; Wolters, D.; Yates, J. R., III. Nat. Biotechnol. 2001, 19, 242-7). In addition, we report an in-depth analysis of the false-positive rates associated with peptide identification using the Sequest algorithm and a reversed yeast protein database. New criteria are proposed to decrease false-positives to less than 1% and to greatly reduce the need for manual interpretation while permitting more proteins to be identified.  相似文献   

15.
Trypsin is the most frequently used proteolytic enzyme in mass spectrometry-based proteomics. Beside its good availability, it also offers some major advantages such as an optimal average peptide length of ~ 14 amino acids, and typically the presence of at least two defined positive charges at the N-terminus as well as the C-terminal Arg/Lys, rendering tryptic peptides well suited for CID-based LC-MS/MS. Here, we conducted a systematic study of different types of commercially available trypsin in order to qualitatively and quantitatively compare cleavage specificity, efficiency as well as reproducibility and the potential impact on quantitation and proteome coverage. We present a straightforward strategy applied to complex digests of human platelets, comprising (1) digest controls using a monolithic column HPLC-setup, (2) SCX enrichment of semitryptic/nonspecific peptides, (3) targeted MRM analysis of corresponding full cleavage/missed cleavage peptide pairs as well as (4) LC-MS analyses of complete digests with a three-step data interpretation. Thus, differences in digest performance can be readily assessed, rendering these procedures extremely beneficial to quality control not only the trypsin of choice, but also to effectively compare as well as optimize different digestion conditions and to evaluate the reproducibility of a dedicated digest protocol for all kinds of quantitative proteome studies.  相似文献   

16.
The complexity of the human proteome, already enormous at the organism level, increases further in the course of the proteome analysis due to in vitro sample evolution. Most of in vitro alterations can also occur in vivo as post-translational modifications. These two types of modifications can only be distinguished a posteriori but not in the process of analysis, thus rendering necessary the analysis of every molecule in the sample. With the new software tool ModifiComb applied to MS/MS data, the extent of modifications was measured in tryptic mixtures representing the full proteome of human cells. The estimated level of 8-12 modified peptides per each unmodified tryptic peptide present at >or=1% level is approaching one modification per amino acid on average. This is a higher modification rate than was previously thought, posing an additional challenge to analytical techniques. The solution to the problem is seen in improving sample preparation routines, introducing dynamic range-adjusted thresholds for database searches, using more specific MS/MS analysis using high mass accuracy and complementary fragmentation techniques, and revealing peptide families with identification of additional proteins only by unfamiliar peptides. Extensive protein separation prior to analysis reduces the requirements on speed and dynamic range of a tandem mass spectrometer and can be a viable alternative to the shotgun approach.  相似文献   

17.
An improved strategy for the preparation of octadecylated silica monolith capillary column with high homogeneity was proposed. Column performance was evaluated by nanoscale HPLC. The design for constructing an integrated nanoelectrospray emitter on the octadecylated silica monolith capillary column was first introduced. In comparison with the separated configuration where the emitter is connected to monolithic capillary column by the aid of a zero dead volume union, the integrated capillary column has the inherent advantage of the minimized extracolumn volume thus providing improved separation quality. The performance of the integrated monolithic capillary column was evaluated by separation of BSA tryptic digest, and peak capacity of 313 with a 30-cm column was obtained. The high separation performance allowed highly confident identification of 662 distinct proteins through assignment of 1933 unique peptides by analysis of tryptic digest of 0.5 mug of Saccharomyces cerevisiae proteins. The higher separation efficiency by a 60-cm monolithic capillary column increased the proteome coverage with identification of 1323 proteins through assignment of 5501 unique peptides over 400-min gradient elution.  相似文献   

18.
Hao P  Guo T  Sze SK 《PloS one》2011,6(2):e16884
Protein post-translational modifications (PTMs) are regulated separately from protein expression levels. Thus, simultaneous characterization of the proteome and its PTMs is pivotal to an understanding of protein regulation, function and activity. However, concurrent analysis of the proteome and its PTMs by mass spectrometry is a challenging task because the peptides bearing PTMs are present in sub-stoichiometric amounts and their ionization is often suppressed by unmodified peptides of high abundance. We describe here a method for concurrent analysis of phosphopeptides, glycopeptides and unmodified peptides in a tryptic digest of rat kidney tissue with a sequence of ERLIC and RP-LC-MS/MS in a single experimental run, thereby avoiding inter-experimental variation. Optimization of loading solvents and elution gradients permitted ERLIC to be performed with totally volatile solvents. Two SCX and four ERLIC gradients were compared in details, and one ERLIC gradient was found to perform the best, which identified 2929 proteins, 583 phosphorylation sites in 338 phosphoproteins and 722 N-glycosylation sites in 387 glycoproteins from rat kidney tissue. Two hundred low-abundance proteins with important functions were identified only from the glyco- or phospho-subproteomes, reflecting the importance of the enrichment and separation of modified peptides by ERLIC. In addition, this strategy enables identification of unmodified and corresponding modified peptides (partial phosphorylation and N-glycosylation) from the same protein. Interestingly, partially modified proteins tend to occur on proteins involved in transport. Moreover, some membrane or extracellular proteins, such as versican core protein and fibronectin, were found to have both phosphorylation and N-glycosylation, which may permit an assessment of the potential for cross talk between these two vital PTMs and their roles in regulation.  相似文献   

19.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

20.
While prefractionation has previously been shown to improve results in MS analysis, a novel combination provides an additional dimension of separation: protein fractionation by SDS‐PAGE followed by IEF of tryptic peptides before separation by RP‐LC [Atanassov and Urlaub, Proteomics 2013, 13, 2947–2955]. This three‐step separation procedure prior to MS/MS substantially increases proteome coverage and represents a further step toward a more comprehensive analysis of complex proteomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号