1.
HTS is a key component of pharmaceutical lead identification process. Over recent years, the pharmaceutical industry has experienced significant increases in the throughput capabilities of its HTS functions. In those companies where HTS has been effectively deployed, it is now possible to screen the entire corporate compound collection against a pharmacological target within a timescale of several weeks to a few months. This capability has been realized, not as a result of the purchase of any one particular piece of hardware, but rather through the development of a truly effective HTS infrastructure that matches the needs of the parent organization. Central to this is the need to understand how to effectively combine the use of the different types of hardware available to the HTS specialist. The use of both modular workstations and single-arm robotic systems have underpinned most HTS groups operations. Recent advances in the field of multiple-arm robotic systems and dedicated automation systems offer even further potential for increasing productivity. This article describes our experience with the use of a dedicated automation system for HTS applications.  相似文献   

2.
The future of high-throughput screening   总被引:3,自引:0,他引:3  
High-throughput screening (HTS) is a well-established process in lead discovery for pharma and biotech companies and is now also being set up for basic and applied research in academia and some research hospitals. Since its first advent in the early to mid-1990s, the field of HTS has seen not only a continuous change in technology and processes but also an adaptation to various needs in lead discovery. HTS has now evolved into a quite mature discipline of modern drug discovery. Whereas in previous years, much emphasis has been put toward a steady increase in capacity ("quantitative increase") via various strategies in the fields of automation and miniaturization, the past years have seen a steady shift toward higher content and quality ("quality increase") for these biological test systems. Today, many experts in the field see HTS at the crossroads with the need to decide either toward further increase in throughput or more focus toward relevance of biological data. In this article, the authors describe the development of HTS over the past decade and point out their own ideas for future directions of HTS in biomedical research. They predict that the trend toward further miniaturization will slow down with the implementation of 384-well, 1536-well, and 384 low-volume-well plates. The authors predict that, ultimately, each hit-finding strategy will be much more project related, tailor-made, and better integrated into the broader drug discovery efforts.  相似文献   

3.
The selection of the highest quality chemical matter from high throughput screening (HTS) is the ultimate aim of any triage process. Typically there are many hundreds or thousands of hits capable of modulating a given biological target in HTS with a wide range of physicochemical properties that should be taken into consideration during triage. Given the multitude of physicochemical properties that define drug-like space, a system needs to be in place that allows for a rapid selection of chemical matter based on a prioritized range of these properties. With this goal in mind, we have developed a tool, coined Abbott Physicochemical Tiering (APT) that enables hit prioritization based on ranges of these important physicochemical properties. This tool is now used routinely at Abbott to help prioritize hits out of HTS during the triage process. Herein we describe how this tool was developed and validated using Abbott internal high throughput ADME data (HT-ADME).  相似文献   

4.
High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100,000 compounds per second.  相似文献   

5.
The transition from manual to robotic high throughput screening (HTS) in the last few years has made it feasible to screen hundreds of thousands of chemical entities against a biological target in less than a month. This rate of HTS has increased the visibility of bottlenecks, one of which is assay optimization. In many organizations, experimental methods are generated by therapeutic teams associated with specific targets and passed on to the HTS group. The resulting assays frequently need to be further optimized to withstand the rigors and time frames inherent in robotic handling. Issues such as protein aggregation, ligand instability, and cellular viability are common variables in the optimization process. The availability of robotics capable of performing rapid random access tasks has made it possible to design optimization experiments that would be either very difficult or impossible for a person to carry out. Our approach to reducing the assay optimization bottleneck has been to unify the highly specific fields of statistics, biochemistry, and robotics. The product of these endeavors is a process we have named automated assay optimization (AAO). This has enabled us to determine final optimized assay conditions, which are often a composite of variables that we would not have arrived at by examining each variable independently. We have applied this approach to both radioligand binding and enzymatic assays and have realized benefits in both time and performance that we would not have predicted a priori. The fully developed AAO process encompasses the ability to download information to a robot and have liquid handling methods automatically created. This evolution in smart robotics has proven to be an invaluable tool for maintaining high-quality data in the context of increasing HTS demands.  相似文献   

6.
We designed and developed NEXUS--a new natural products screening database and related suite of software applications--to utilize the spectacular increases in assay capacity of the modern high throughput screening (HTS) environment. NEXUS not only supports seamless integration with separate HTS systems, but supports user-customized integration with external laboratory automation, particularly sample preparation systems. Designed and developed based on a detailed process model for natural products drug discovery, NEXUS comprises two integrated parts: (1) a single schema of Oracle tables and callable procedures and functions, and (2) software "front-ends" to the database developed using Microsoft Excel and Oracle Discovery/2000. Many of the back-end processing functions were written in Programming Language/Structured Query Language (PL/SQL) to provide an Application Programmer's Interface, which allows end users to create custom applications with little input from information technology professionals.  相似文献   

7.
The drug discovery process pursued by major pharmaceutical companies for many years starts with target identification followed by high-throughput screening (HTS) with the goal of identifying lead compounds. To accomplish this goal, significant resources are invested into automation of the screening process or HTS. Robotic systems capable of handling thousands of data points per day are implemented across the pharmaceutical sector. Many of these systems are amenable to handling cell-based screening protocols as well. On the other hand, as companies strive to develop innovative products based on novel mechanisms of action(s), one of the current bottlenecks of the industry is the target validation process. Traditionally, bioinformatics and HTS groups operate separately at different stages of the drug discovery process. The authors describe the convergence and integration of HTS and bioinformatics to perform high-throughput target functional identification and validation. As an example of this approach, they initiated a project with a functional cell-based screen for a biological process of interest using libraries of small interfering RNA (siRNA) molecules. In this protocol, siRNAs function as potent gene-specific inhibitors. siRNA-mediated knockdown of the target genes is confirmed by TaqMan analysis, and genes with impacts on biological functions of interest are selected for further analysis. Once the genes are confirmed and further validated, they may be used for HTS to yield lead compounds.  相似文献   

8.
The Joint Center for Structural Genomics (JCSG) has emphasized automation and parallel processing approaches. Here, we describe automated methods used across the cloning process with results from JCSG projects. The protocols for PCR, restriction digests and ligations, as well as for gel electrophoresis and microtiter plate assays have all been automated. The system has the capacity to routinely process 384 clones a week. This throughput can adequately supply our expression and purification pipeline with expression-ready clones, including novel targets and truncations. The utility of our system is demonstrated by our results from three diverse projects. In summary, 94% of the PCR amplicons generated to date have been successfully cloned and verified by sequencing (83% of the total attempted targets). Our results demonstrate the capabilities of this robotic platform to provide an avenue to high-throughput cloning which requires little manpower and is rapid and cost-effective while providing insights for method optimization.  相似文献   

9.
Exocellulases play a key role in cleaving the accessible ends of cellulose molecules to release soluble glucose and cellobiose. To date, there have been no screens for exocellulase owing to assay protocol limitations, the high cost of substrates, and low activity of exocellulases compared with endocellulases. This study is the first to demonstrate direct screening for exocellulase activity using a robotic, high-throughput screening (HTS) system. Cell growth in 96-well plates was measured by monitoring optical density over 11–14 h at 37 °C with agitation. Fluorescence of methylumbelliferyl groups released from 4-methylumbelliferyl-β-D-cellobioside was determined using a VICTOR3 microplate reader. This new HTS system enabled activity verification of more than 104 clones per day. As a result, we obtained four exocellulases clones (CelEx-SF301, CelEx-SF309, CelEx-BR12 and CelEx-BR15) from 29,006 metagenomic fosmid clones that had previously been prepared from sweet potato field soil microbes and rumen fluid. This powerful approach could be effectively applied to screen various metagenomic resources for new enzymes.  相似文献   

10.
Reporter-based assays underlie many high-throughput screening (HTS) platforms, but most are limited to in vitro applications. Here, we report a simple whole-organism HTS method for quantifying changes in reporter intensity in individual zebrafish over time termed, Automated Reporter Quantification in vivo (ARQiv). ARQiv differs from current "high-content" (e.g., confocal imaging-based) whole-organism screening technologies by providing a purely quantitative data acquisition approach that affords marked improvements in throughput. ARQiv uses a fluorescence microplate reader with specific detection functionalities necessary for robust quantification of reporter signals in vivo. This approach is: 1) Rapid; achieving true HTS capacities (i.e., >50,000 units per day), 2) Reproducible; attaining HTS-compatible assay quality (i.e., Z'-factors of ≥0.5), and 3) Flexible; amenable to nearly any reporter-based assay in zebrafish embryos, larvae, or juveniles. ARQiv is used here to quantify changes in: 1) Cell number; loss and regeneration of two different fluorescently tagged cell types (pancreatic beta cells and rod photoreceptors), 2) Cell signaling; relative activity of a transgenic Notch-signaling reporter, and 3) Cell metabolism; accumulation of reactive oxygen species. In summary, ARQiv is a versatile and readily accessible approach facilitating evaluation of genetic and/or chemical manipulations in living zebrafish that complements current "high-content" whole-organism screening methods by providing a first-tier in vivo HTS drug discovery platform.  相似文献   

11.
Microbial HTS has been implemented at Rh?ne-Poulenc Rorer through the development of a dedicated robotic platform. This robot (Turbo) has been designed with the aim of fully integrating microbial HTS into the lead discovery processes. Innovative solutions have been found to reach high throughput as well as flexibility. This opens up new prospects for solid-phase microbial screening, taking advantage of the easy implementation and the very low costs of such screens. The different types of microbial screens done in our laboratory, as well as the throughputs and outputs obtained, are described. Some of the specific aspects of microbial HTS, as compared to biochemical and cell-based assays, are also discussed.  相似文献   

12.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

13.
High throughput drug screening has become a critical component of the drug discovery process. The screening of libraries containing hundreds of thousands of compounds has resulted in a requirement for assays and instrumentation that are amenable to nonradioactive formats and that can be miniaturized. Homogeneous assays that minimize upstream automation of the individual assays are also preferable. Fluorometric microvolume assay technology (FMAT) is a fluorescence-based platform for the development of nonradioactive cell- and bead-based assays for HTS. This technology is plate format-independent, and while it was designed specifically for homogeneous ligand binding and immunological assays, it is amenable to any assay utilizing a fluorescent cell or bead. The instrument fits on a standard laboratory bench and consists of a laser scanner that generates a 1 mm(2) digitized image of a 100-μmm deep section of the bottom of a microwell plate. The instrument is directly compatible with a Zymark Twistertrade mark (Zymark Corp., Hopkinton, MA) for robotic loading of the scanner and unattended operation in HTS mode. Fluorescent cells or beads at the bottom of the well are detected as localized areas of concentrated fluorescence using data processing. Unbound flurophore comprising the background signal is ignored, allowing for the development of a wide variety of homogeneous assays. The use of FMAT for peptide ligand binding assays, immunofluorescence, apoptosis and cytotoxicity, and bead-based immunocapture assays is described here, along with a general overview of the instrument and software.  相似文献   

14.
The incursion of High-Throughput Sequencing (HTS) in environmental microbiology brings unique opportunities and challenges. HTS now allows a high-resolution exploration of the vast taxonomic and metabolic diversity present in the microbial world, which can provide an exceptional insight on global ecosystem functioning, ecological processes and evolution. This exploration has also economic potential, as we will have access to the evolutionary innovation present in microbial metabolisms, which could be used for biotechnological development. HTS is also challenging the research community, and the current bottleneck is present in the data analysis side. At the moment, researchers are in a sequence data deluge, with sequencing throughput advancing faster than the computer power needed for data analysis. However, new tools and approaches are being developed constantly and the whole process could be depicted as a fast co-evolution between sequencing technology, informatics and microbiologists. In this work, we examine the most popular and recently commercialized HTS platforms as well as bioinformatics methods for data handling and analysis used in microbial metagenomics. This non-exhaustive review is intended to serve as a broad state-of-the-art guide to researchers expanding into this rapidly evolving field.  相似文献   

15.
High throughput screening (HTS) is at the core of the drug discovery process, and so it is critical to design and implement HTS assays in a comprehensive fashion involving scientists from the disciplines of biology, chemistry, engineering, and informatics. This requires careful analysis of many variables, starting with the choice of assay target and ending with the discovery of lead compounds. At every step in this process, there are decisions to be made that can greatly impact the outcome of the HTS effort, to the point of making it a success or a failure. Although specific guidelines should be established to insure that the screening assay reaches an acceptable level of quality, many choices require pragmatism and the ability to compromise opposing forces.  相似文献   

16.
A M Steff  M Fortin  C Arguin  P Hugo 《Cytometry》2001,45(4):237-243
BACKGROUND: Reliable assessment of cell death is now pivotal to many research programs aiming at generating new anti-tumor compounds or at screening cDNA libraries. Such approaches need to rely on reproducible, easy-to-handle, and rapid microplate-based cytotoxicity assays that are amenable to high-throughput screening (HTS) technologies. We describe a method for the direct measurement of cell death, based on the detection of a decrease in fluorescence observed following death induction in cells expressing enhanced green fluorescent protein (EGFP). METHODS: Cell death was induced by a variety of apoptotic stimuli in various EGFP-expressing mammalian cell lines, including those routinely used in anti-cancer drug screening. Decrease in fluorescence was assessed either by flow cytometry (and compared with other apoptotic markers) or by a fluorescence microplate reader. RESULTS: Cells expressing EGFP exhibited a decrease in fluorescence when treated by various agents, such as chemotherapeutic drugs, UV irradiation, or caspase-independent cell death inducers. Kinetics and sensitivity of this EGFP-based assay were comparable to those of traditional apoptosis markers such as annexin-V binding, propidium iodide incorporation, or reactive oxygen species production. We also show that the decrease in EGFP fluorescence is directly quantifiable in a fluorescence-based microplate assay. Furthermore, analysis of EGFP protein content in cells undergoing cell death demonstrates that the decrease in fluorescence does not arise from degradation of the protein. CONCLUSIONS: This novel GFP-based microplate assay combines sensitivity and rapidity, is easily amenable to HTS setups, making it an assay of choice for cytotoxicity evaluation.  相似文献   

17.
One of the critical steps in high throughput crystallography that so far has evaded automation is the actual harvesting of the delicate crystals from the mother liquor in which they are growing. The late-stage operation of harvesting is presently a most risky and loss-intensive procedure, compounded by its tight integration with the critical steps of cryo-protection and cryo-quenching. Recent advances in micromanipulation robotics and micro-fabrication have made it possible to seriously consider automation of protein crystal harvesting. Based on the experience gained during the development of an operator-assisted (and now operator-assisting) universal micromanipulation robot (UMR) prototype, we discuss the challenges ahead for the design of a fully autonomous, integrated system capable of the reliable harvesting of protein microcrystals. Experience from participation in NIH structural genomics projects and feedback from bottleneck workshops indicates that genuine demand exists in the high throughput community as well as in pharmaceutical production pipelines, justifying the effort and resources to develop autonomous harvesting robotics.  相似文献   

18.
An immunoassay for interferon-gamma (IFN-gamma) using homogeneous time-resolved fluorescence (HTRF) has been developed. In this assay, IFN-gamma can be detected by simply adding a mixture of three reagents-biotinylated polyclonal antibody, europium cryptate (fluorescence donor, EuK)-labeled monoclonal antibody, and crosslinked allophycocyanin (fluorescence acceptor, XL665) conjugated with streptavidin-and then measuring the time-resolved fluorescence. The detection limit of IFN-gamma by the proposed method is about 625 pg/ml. We applied the method to the detection of IFN-gamma secreted from NK3.3 cells and employed it in high throughput screening for IFN-gamma production inhibitors. With this screening format, IFN-gamma can be measured by directly adding the above reagents to microplate wells where NK3.3 cells are being cultured and stimulated with interleukin-12. This "in situ" immunoassay requires only pipetting reagents, with no need to transfer the culture supernatant to another microplate or wash the plate. Therefore, this screening format makes possible full automation of cell-based immunoassay, thus reducing cost and experimental time while increasing accuracy and throughput.  相似文献   

19.
Flow cytometry specializes in high-content measurements of cells and particles in suspension. Having long excelled in analytical throughput of single cells and particles, only recently with the advent of HyperCyt sampling technology, flow cytometry's multiexperiment throughput has begun to approach the point of practicality for efficiently analyzing hundreds-of-thousands of samples, the realm of high-throughput screening (HTS). To extend performance and automation compatibility, we built a HyperCyt-linked Cluster Cytometer platform, a network of flow cytometers for analyzing samples displayed in high-density, 1,536-well plate format. To assess the performance, we used cell- and microsphere-based HTS assays that had been well characterized in the previous studies. Experiments addressed important technical issues: challenges of small wells (assay volumes 10 μL or less, reagent mixing, cell and particle suspension), detecting and correcting for differences in performance of individual flow cytometers, and the ability to reanalyze a plate in the event of problems encountered during the primary analysis. Boosting sample throughput an additional fourfold, this platform is uniquely positioned to synergize with expanding suspension array and cell barcoding technologies in which as many as 100 experiments are performed in a single well or sample. As high-performance flow cytometers shrink in cost and size, cluster cytometry promises to become a practical, productive approach for HTS, and other large-scale investigations of biological complexity.  相似文献   

20.

Background

Shared-usage high throughput screening (HTS) facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups.

Results

We have developed Screensaver, a free, open source, web-based lab information management system (LIMS), to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects.

Conclusions

The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.  相似文献   