首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Picosecond multiphoton scanning near-field optical microscopy.   总被引:2,自引:0,他引:2       下载免费PDF全文
We have implemented simultaneous picosecond pulsed two- and three-photon excitation of near-UV and visible absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 1064-nm emission from a pulsed Nd:YVO4 laser was used to excite the visible mitochondrial specific dye MitoTracker Orange CM-H2TMRos or a Cy3-labeled antibody by two-photon excitation, and the UV absorbing DNA dyes DAPI and the bisbenzimidazole BBI-342 by three-photon excitation, in a shared aperture SNOM using uncoated fiber tips. Both organelles in human breast adenocarcinoma cells (MCF 7) and specific protein bands on polytene chromosomes of Drosophila melanogaster doubly labeled with a UV and visible dye were readily imaged without photodamage to the specimens. The fluorescence intensities showed the expected nonlinear dependence on the excitation power over the range of 5-40 mW. An analysis of the dependence of fluorescence intensity on the tip-sample displacement normal to the sample surface revealed a higher-order function for the two-photon excitation compared to the one-photon mode. In addition, the sample photobleaching patterns corresponding to one- and two-photon modes revealed a greater lateral confinement of the excitation in the two-photon case. Thus, as in optical microscopy, two-photon excitation in SNOM is confined to a smaller volume.  相似文献   

2.
Two-photon fluorescence excitation has been found to be a very powerful method for enhancing the sensitivity and resolution in far-field light microscopy. Two-photon fluorescence excitation also provides a substantially background-free detection on the single-molecule level. It allows direct monitoring of formation of labelled biomolecule complexes in solution. Two-photon excitation is created when, by focusing an intensive light source, the density of photons per unit volume and per unit time becomes high enough for two photons to be absorbed into the same chromophore. In this case, the absorbed energy is the sum of the energies of the two photons. In two-photon excitation, dye molecules are excited only when both photons are absorbed simultaneously. The probability of absorption of two photons is equal to the product of probability distributions of absorption of the single photons. The emission of two photons is thus a quadratic process with respect to illumination intensity. Thus in two-photon excitation, only the fluorescence that is formed in the clearly restricted three-dimensional vicinity of the focal point is excited. We have developed an assay concept that is able to distinguish optically between the signal emitted from a microparticle in the focal point of the laser beam, and the signal emitted from the surrounding free labelled reagent. Moreover, the free labels outside the focal volume do not contribute any significant signal. This means that the assay is separation-free. The method based on two-photon fluorescence excitation makes possible fast single-step and separation-free immunoassays, for example, for whole blood samples. Since the method allows a separation-free assay in very small volumes, the method is very useful for high-throughput screening assays. Consequently we believe that two-photon fluorescence excitation will make a remarkable impact as a research tool and a routine method in many fields of analysis.  相似文献   

3.
Continuous wave two-photon scanning near-field optical microscopy.   总被引:1,自引:0,他引:1       下载免费PDF全文
We have implemented continuous-wave two-photon excitation of near-UV absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 647-nm emission of an Ar-Kr mixed gas laser was used to excite the UV-absorbing DNA dyes DAPI, the bisbenzimidazole Hoechst 33342, and ethidium bromide in a shared aperture SNOM with uncoated fiber tips. Polytene chromosomes of Drosophila melanogaster and the nuclei of 3T3 Balb/c cells labeled with these dyes were readily imaged. The fluorescence intensity showed the expected nonlinear (second order) dependence on the excitation power in the range of 8-180 mW. We measured the fluorescence intensity as a function of the tip-sample displacement in the direction normal to the sample surface in the single- and two-photon excitation modes (SPE, TPE). The fluorescence intensity decayed faster in TPE than in SPE.  相似文献   

4.
We achieve simultaneous two-photon excitation of three chromophores with distinct absorption spectra using synchronized pulses from a femtosecond laser and an optical parametric oscillator. The two beams generate separate multiphoton processes, and their spatiotemporal overlap provides an additional two-photon excitation route, with submicrometer overlay of the color channels. We report volume and live multicolor imaging of 'Brainbow'-labeled tissues as well as simultaneous three-color fluorescence and third-harmonic imaging of fly embryos.  相似文献   

5.
We demonstrate broad-field, non-scanning, two-photon excitation fluorescence (2PEF) close to a glass/cell interface by total internal reflection of a femtosecond-pulsed infrared laser beam. We exploit the quadratic intensity dependence of 2PEF to provide non-linear evanescent wave (EW) excitation in a well-defined sample volume and to eliminate scattered background excitation. A simple model is shown to describe the resulting 2PEF intensity and to predict the effective excitation volume in terms of easily measurable beam, objective and interface properties. We demonstrate non-linear evanescent wave excitation at 860 nm of acridine orange-labelled secretory granules in live chromaffin cells, and excitation at 900 nm of TRITC-phalloidin-actin/GPI-GFP double-labelled fibroblasts. The confined excitation volume and the possibility of simultaneous multi-colour excitation of several fluorophores make EW 2PEF particularly advantageous for quantitative microscopy, imaging biochemistry inside live cells, or biosensing and screening applications in miniature high-density multi-well plates.Abbreviations 1PEF one-photon excited fluorescence - 2PEF two-photon excited fluorescence - APD avalanche photo diode - CHO Chinese hamster ovary - DMEM Dulbecco's modified Eagle's medium - EGFP enhanced green fluorescent protein - EW evanescent wave - FCS fetal calf serum - GPI glycosylphosphatidylinositol - TIR total internal reflectionThis paper is dedicated to the memory of Prof. Horst Harreis (1940–2002)  相似文献   

6.
The tumor-localizing photosensitizer hematoporphyrin derivative (HPD) is shown to undergo a simultaneous two-photon excitation into the near-ultraviolet Soret band system upon intense laser irradiation at 750 nm, a spectral region where there is no significant HPD one-photon absorbance in aqueous solution. Subsequent to this excitation, internal conversion and vibrational relaxation occur, resulting in the population of the vibrationless level of the first electronically excited singlet state. This state relaxes by two channels, the emission of fluorescence in the spectral region 600-700 nm and intersystem crossing into the triplet manifold, followed by near-resonant electronic energy transfer with surrounding oxygen to result in the generation of highly reactive singlet molecular oxygen (1 delta g). Evidence for the two-photon excitation consists in the observation both of the HPD fluorescence spectrum in the region of 615 nm as a result of 750 nm excitation and the quadratic dependence of this fluorescence emission intensity upon the excitation laser intensity. Since, in general, the penetration depth of ultraviolet and visible light into tissue varies directly with wavelength (red penetrating more deeply than blue), these studies suggest the possibility that two-photon-induced localization of tumor-bound HPD might facilitate the detection of deeper lying tumors than allowed by the current one-photon photolocalization method.  相似文献   

7.
We demonstrate the direct 1064 nm two-photon excitation of hematoporphyrin derivative (HPD), a complex mixture of photosensitizing porphyrins which is selectively retained in tumor tissue and used in cancer photochemotherapy. Although 1064 nm is outside of the one-photon HPD absorption spectrum, two-photon induced fluorescence from HPD was observed following excitation by the 20 ns output of an amplified, Q-switched Nd-YAG laser at peak power levels of 0.1 to 3 GW/cm2. Evidence for the successful two-photon excitation to vibrational levels of the S1 state consists of the observation of the known HPD fluorescence spectrum exhibiting peaks at approximately 615 and 675 nm, with the observed two-photon induced fluorescence intensity exhibiting a quadratic dependence on the excitation laser intensity as required for a direct two-photon process. More generally, these results suggest the possibility for the achievement of photosensitized oxidations utilizing photons of lower energy than that required for single photon excitation, offering the potential for both greater selectivity and a reduction in competing photochemical processes.  相似文献   

8.
Two-photon probe excitation data are commonly presented as absorption cross section or molecular brightness (the detected fluorescence rate per molecule). We report two-photon molecular brightness spectra for a diverse set of organic and genetically encoded probes with an automated spectroscopic system based on fluorescence correlation spectroscopy. The two-photon action cross section can be extracted from molecular brightness measurements at low excitation intensities, while peak molecular brightness (the maximum molecular brightness with increasing excitation intensity) is measured at higher intensities at which probe photophysical effects become significant. The spectral shape of these two parameters was similar across all dye families tested. Peak molecular brightness spectra, which can be obtained rapidly and with reduced experimental complexity, can thus serve as a first-order approximation to cross-section spectra in determining optimal wavelengths for two-photon excitation, while providing additional information pertaining to probe photostability. The data shown should assist in probe choice and experimental design for multiphoton microscopy studies. Further, we show that, by the addition of a passive pulse splitter, nonlinear bleaching can be reduced--resulting in an enhancement of the fluorescence signal in fluorescence correlation spectroscopy by a factor of two. This increase in fluorescence signal, together with the observed resemblance of action cross section and peak brightness spectra, suggests higher-order photobleaching pathways for two-photon excitation.  相似文献   

9.
Yan L  Rueden CT  White JG  Eliceiri KW 《BioTechniques》2006,41(3):249, 251, 253 passim
Live cell imaging has been greatly advanced by the recent development of new fluorescence microscopy-based methods such as multiphoton laser-scanning microscopy, which can noninvasively image deep into live specimens and generate images of extrinsic and intrinsic signals. Of recent interest has been the development of techniques that can harness properties of fluorescence, other than intensity, such as the emission spectrum and excited state lifetime of a fluorophore. Spectra can be used to discriminate between fluorophores, and lifetime can be used to report on the microenvironment of fluorophores. We describe a novel technique-combined spectral and lifetime imaging-which combines the benefits of multiphoton microscopy, spectral discrimination, and lifetime analysis and allows for the simultaneous collection of all three dimensions of data along with spatial and temporal information.  相似文献   

10.
Photobleaching in two-photon excitation microscopy   总被引:10,自引:0,他引:10       下载免费PDF全文
The intensity-squared dependence of two-photon excitation in laser scanning microscopy restricts excitation to the focal plane and leads to decreased photobleaching in thick samples. However, the high photon flux used in these experiments can potentially lead to higher-order photon interactions within the focal volume. The excitation power dependence of the fluorescence intensity and the photobleaching rate of thin fluorescence samples ( approximately 1 microm) were examined under one- and two-photon excitation. As expected, log-log plots of excitation power versus the fluorescence intensity and photobleaching rate for one-photon excitation of fluorescein increased with a slope of approximately 1. A similar plot of the fluorescence intensity versus two-photon excitation power increased with a slope of approximately 2. However, the two-photon photobleaching rate increased with a slope > or =3, indicating the presence of higher-order photon interactions. Similar experiments on Indo-1, NADH, and aminocoumarin produced similar results and suggest that this higher-order photobleaching is common in two-photon excitation microscopy. As a consequence, the use of multi-photon excitation microscopy to study thin samples may be limited by increased photobleaching.  相似文献   

11.
Multiphoton excitation microscopy at 730 nm and 960 nm was used to image in vivo human skin autofluorescence from the surface to a depth of approximately 200 microm. The emission spectra and fluorescence lifetime images were obtained at selected locations near the surface (0-50 microm) and at deeper depths (100-150 microm) for both excitation wavelengths. Cell borders and cell nuclei were the prominent structures observed. The spectroscopic data suggest that reduced pyridine nucleotides, NAD(P)H, are the primary source of the skin autofluorescence at 730 nm excitation. With 960 nm excitation, a two-photon fluorescence emission at 520 nm indicates the presence of a variable, position-dependent intensity component of flavoprotein. A second fluorescence emission component, which starts at 425 nm, is observed with 960-nm excitation. Such fluorescence emission at wavelengths less than half the excitation wavelength suggests an excitation process involving three or more photons. This conjecture is further confirmed by the observation of the super-quadratic dependence of the fluorescence intensity on the excitation power. Further work is required to spectroscopically identify these emitting species. This study demonstrates the use of multiphoton excitation microscopy for functional imaging of the metabolic states of in vivo human skin cells.  相似文献   

12.
We report on a novel technology for multicolor gene and chromosome detection as well as for three-dimensional (3D) DNA imaging by multiphoton excitation of multiple FISH fluorophores and DNA stains. Near infrared femtosecond laser pulses at 770 nm were used to simultaneously excite the visible fluorescence of a wide range of FISH fluorophores, such as FITC, DAC, Cy3, Cy5, Cy5.5, rhodamine, spectrum aqua, spectrum green, spectrum orange, Jenfluor, and Texas red as well as of DNA/chromosome stains, for example Hoechst 33342, DAPI, SYBR green, propidium iodide, ethidium homodimer, and Giemsa. In addition to the advantage of using only one excitation wavelength for a variety of fluorophores, multiphoton excitation provided the intrinsic possibility of 3D fluorescence imaging. The technology has been used in human genetics for the diagnosis of numerical chromosome aberrations and microdeletions. In particular, multicolor 3D images of the intranuclear localization of FISH-labeled chromosome territories in interphase nuclei of amniotic fluid cells have been obtained. Using the high light penetration depth at 770 nm, optical sectioning of Hoechst 33342-labeled DNA within living culture cells and within tissue of living tumor-bearing mice was performed.  相似文献   

13.
14.
Fluorescence cross-correlation spectroscopy is a powerful method for the study of molecular interactions and dynamics in solution and even in living cells. Usually, in the optical setup, either two laser beams have to be superimposed in their respective confocal volumes or two-photon excitation is used for a dual-color detection system. It has been shown recently that fluorescence cross correlation can be achieved with spectrally similar fluorophores using single wavelength excitation fluorescence cross-correlation spectroscopy (SW-FCCS). In this study, we show that SW-FCCS allows the simultaneous excitation of up to three fluorophores in which the cross correlation of their fluctuation signals is detected separately in three detection channels. The experimental and theoretical model to describe triple pairwise cross correlations incorporating cross talk and possible changes in emission characteristics such as quenching upon binding are outlined. The effectiveness of SW-FCCS to detect binding of three interacting partners is experimentally verified with a standard ligand-receptor model, biotin-streptavidin, where differently labeled biotin ligands and their binding to a third-color labeled streptavidin are studied. The cross-correlation amplitudes and their changes with stoichiometric binding are analyzed and the upper limits of dissociation constants are determined. Performed with appropriate negative controls, SW-FCCS can determine interaction patterns between ligands and receptors.  相似文献   

15.
H J Koester  D Baur  R Uhl    S W Hell 《Biophysical journal》1999,77(4):2226-2236
The signal and limitations of calcium florescence imaging using nonresonant multiphoton absorption of near-infrared femto- and picosecond laser pulses were examined. The fluorescence changes of various Ca(2+)-indicators induced by transient increases of the intradendritic calcium concentration were evaluated by evoking physiological activity in neocortical neurons in rat brain slices. Photodamage was noticeable as irreversible changes in the parameters describing the calcium fluorescence transients. At higher two-photon excitation rates, a great variety of irregular functional and structural alterations occurred. Thus, signal and observation time were limited by phototoxic effects. At lower excitation rates, photodamage accumulated linearly with exposure time. Femtosecond and picosecond laser pulses were directly compared with respect to this cumulative photodamage. The variation of the pulse length at a constant two-photon excitation rate indicated that a two-photon excitation mechanism is mainly responsible for the cumulative photodamage within the investigated window of 75 fs to 3.2 ps. As a direct consequence, at low excitation rates, the same image quality is achieved irrespective of whether two-photon Ca(2+)-imaging is carried out with femto- or picosecond laser pulses.  相似文献   

16.
Dimethyl-pepep (D-pepep), a newly developed and very efficient two-photon absorber, has been tested here for two-photon excitation (TPE) cellular imaging. The spectral characteristics of the dye following one-photon excitation (OPE) and TPE (excitation and emission spectra, fluorescence lifetime, molecular brightness, saturation intensity) are reported. In vitro interaction studies with biomolecules show that dimethyl-pepep has a large affinity for DNA. A comparison with a widely used DNA stainer, 4-6-diamidino-2-phenylindole (DAPI) bound to DNA shows that the D-pepep brightness is one order of magnitude higher than that of DAPI, making this dye suitable for microscopy and imaging applications. TPE images taken from double-stained yeast Saccharomyces cerevisiae cells have revealed that D-pepep localizes mainly in the nucleus, similarly to DAPI, and in mitochondria, although to a minor extent. Preliminary tests have shown that the dye cellular toxicity is negligible.  相似文献   

17.
In this study we demonstrate a new noninvasive imaging method to monitor freezing processes in biological samples and to investigate life in the frozen state. It combines a laser scanning microscope with a computer-controlled cryostage. Nearinfrared (NIR) femtosecond laser pulses evoke the fluorescence of endogenous fluorophores and fluorescent labels due to multiphoton absorption.The inherent optical nonlinearity of multiphoton absorption allows 3D fluorescence imaging for optical tomography of frozen biological material in-situ. As an example for functional imaging we use fluorescence lifetime imaging (FLIM) to create images with chemical and physical contrast.  相似文献   

18.
应用Nd:YAG激光器和光学光谱分析仪对蛋白质分子的同时吸收双光子过程作了进一步研究,讨论了蛋白质分子双光子过程的特性和估计了它们的双光子吸收截面,并得到胰蛋白酶,白蛋白和色氨酸等分子由于双光子激发产生的荧光光谱.  相似文献   

19.
The fluorescence spectral properties of recombinant green fluorescent protein (rGFP) were examined with one- and two-photon excitations using femtosecond pulses from a Ti:sapphire laser. Intensity-dependent properties of the two-photon-induced fluorescence from rGFP excited by an 800-nm, 100-fs laser beam were reported, and the two-photon excitation cross section of rGFP was measured at 800 nm as about 160 x 10(-50) cm(4)s/photon. The possible excited-state proton transfer between two electronic states at about 400 nm in protonated (RH) species and 478 nm in deprotonated (R(-)) species in rGFP was confirmed by fluorescence and fluorescence excitation anisotropy spectra. A subelectronic state (or vibronic progression) at about 420 nm in RH species was identified, which was relatively stable and not involved in the excited state proton transfer in rGFP upon irradiation.  相似文献   

20.
Three-photon induced fluorescence of the calcium probe Indo-1.   总被引:1,自引:0,他引:1       下载免费PDF全文
We report the calcium-dependent emission spectral properties of the calcium probe Indo-1 for three-photon excitation. We found that Indo-1 could be readily excited with the femtosecond pulses from a mode-locked Ti:sapphire laser at 885 nm. This wavelength is too long for two-photon excitation, which is expected to occur for wavelengths no longer than twice the longest single-photon absorption wavelength of 400 nm. For excitation at 885 nm the emission intensity was found to depend on the cube of the laser power, as expected for simultaneous interaction with three photons. At wavelengths below 840 nm the emission intensity depends on the square of the laser power, indicating two-photon excitation at shorter wavelengths. The intensity decays of Indo-1 were found to be dependent on Ca2+ and essentially identical for one- and three-photon excitation. The emission anisotropy of Indo-1 was found to be considerably higher for three-photon excitation than for one-photon excitation, consistent with cos6 theta photoselection, as compared with cos2 theta photoselection for one-photon excitation. The high values of the anisotropy are in agreement with those expected for a three-photon process. Calcium-dependent emission spectra were observed for Indo-1 with three-photon excitation, demonstrating that three-photon excitation of Indo-1 can be used for calcium imaging by emission intensity ratio measurements. The calcium-dependent emission spectra indicate a higher three-photon cross-section for the calcium-free form of Indo-1 than for the calcium-bound form. The possible advantages of three-photon excitation include the availability of the appropriate wavelengths with solid-state lasers, enhanced spatial resolution due to a reduced size of the excited volume, absence of light quenching, and possibly high selectivity of the three-photon excitation process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号