首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
单分子荧光检测技术是利用荧光基团对目的分子标记后,在单分子水平成像并追踪分子的构象变化、动力学特征以及分子之间相互作用的研究方法.相较于传统分子生物学和遗传学的研究手段,单分子检测技术可以对单个分子的动态和特性进行分析,特别是瞬时或偶发性的事件,从而更加深入地挖掘在群体测量中被掩盖的信息.该技术已广泛应用于动物细胞生物...  相似文献   

2.
Naturally occurring mutant forms of p53 are deficient for specific DNA binding. However, their specific DNA binding can be reactivated. The search for small molecules that reactivate latent p53 is considered to be a cornerstone in cancer therapy. The authors describe a new homogeneous fluorescent assay approach for the characterization of binding affinities of human wild-type latent and activated p53 using DNA(*)spec(26), with and without the addition of the antibody PAb421, respectively, and fluorescence correlation spectroscopy (FCS)/2-dimensional fluorescence-intensity distribution analysis anisotropy as the detection methods. FCS was compared with 2D-FIDA anisotropy, and a very good correlation of the results with both readouts was observed (K(D)s for nonspecific DNA binding of 24.4+/-3.5 nM with 2D-FIDA anisotropy and of 29.5+/-5.5 nM with FCS). The presence of poly(dI-dC) led to a 10-fold increase of binding affinity (K(D) of 3.3+/-0.5 nM in the presence of PAb421). 2D-FIDA anisotropy was demonstrated to be the most accurate readout; hence, this detection technology was selected for a 25,000 compound member high-throughput screening (HTS) campaign. The hits obtained were qualified using a novel data evaluation algorithm that identifies false positives and moreover assesses the validity of true hits in the presence of the deteriorating artifact. This process step is of utmost importance for decreasing the attrition in fluorescence-based HTS.  相似文献   

3.
Fluorescence correlation spectroscopy (FCS) and fluorescence cross-correlation spectroscopy (FCCS) are powerful techniques to measure molecular interactions with high sensitivity in homogeneous solution and living cells. In this study, we developed methods for the detection of prion protein (PrP) using FCS and FCCS. A combination of a fluorescent-labeled Fab' fragment and another anti-PrP monoclonal antibody (mAb) enabled us to detect recombinant bovine PrP (rBoPrP) using FCS because there was a significant difference in the diffusion coefficients between the labeled Fab' fragment and the trimeric immune complex consisting of rBoPrP, labeled Fab' fragment, and another anti-PrP mAb. On the other hand, FCCS detected rBoPrP using two mAbs labeled with different fluorescence dyes. The detection limit for PrP in FCCS was approximately threefold higher than that in FCS. The sensitivity of FCCS in detection of abnormal isoform of PrP (PrP(Sc)) was comparable to that of enzyme-linked immunosorbent assay (ELISA). Because FCS and FCCS detect the PrP immune complex in homogeneous solution of only microliter samples with a single mixing step and without any washing steps, these features of measurement may facilitate automating bovine spongiform encephalopathy diagnosis.  相似文献   

4.
High-throughput screening (HTS), a major component of lead identification, often utilizes fluorescence-based assay technologies. For example, HTS kinase assays are formatted using a variety of fluorescence-based assay technologies including, but not limited to, dissociation enhanced lanthanide fluoroimmunoassay (DELFIA), time-resolved fluorescence resonance energy transfer (TR-FRET), and fluorescence polarization (FP). These assays offer tremendous advantages such as a nonradioactive format, ease of automation, and excellent reproducibility. Fluorescence-based assays frequently used for lead identification can also be useful for structure activity relationship (SAR) studies during lead optimization. An important issue when assessing an assay to be used for SAR is the ability of the assay to discriminate high-affinity small molecule inhibitors (pM-nM) from low-affinity inhibitors (microM-mM). The purpose of this study was to utilize HTS-friendly assay formats for SAR by developing TR-FRET, FP, and DELFIAassays measuring Src kinase activity and to define the theoretical lower limit of small molecule inhibitor detection achievable with these assay formats. The authors show that 2 homogeneous assay formats, TR-FRET and FP, allowed for the development of Src kinase assays with a lower limit of detection of K(i) = 0.01 nM. This study indicates that assay technologies typically used for HTS can be used during lead optimization by providing quantitative measurements of compound activity critical to driving SAR studies.  相似文献   

5.
High-throughput screening (HTS) of large chemical libraries has become the main source of new lead compounds for drug development. Several specialized detection technologies have been developed to facilitate the cost- and time-efficient screening of millions of compounds. However, concerns have been raised, claiming that different HTS technologies may produce different hits, thus limiting trust in the reliability of HTS data. This study was aimed to investigate the reliability of the authors most frequently used assay techniques: scintillation proximity assay (SPA) and homogeneous time-resolved fluorescence resonance energy transfer (TR-FRET). To investigate the data concordance between these 2 detection technologies, the authors screened a large subset of the Schering compound library consisting of 300,000 compounds for inhibitors of a nonreceptor tyrosine kinase. They chose to set up this study in realistic HTS scale to ensure statistical significance of the results. The findings clearly demonstrate that the choice of detection technology has no significant impact on hit finding, provided that assays are biochemically equivalent. Data concordance is up to 90%. The little differences in hit findings are caused by threshold setting but not by systematic differences between the technologies. The most significant difference between the compared techniques is that in the SPA format, more false-positive primary hits were obtained.  相似文献   

6.
A M Steff  M Fortin  C Arguin  P Hugo 《Cytometry》2001,45(4):237-243
BACKGROUND: Reliable assessment of cell death is now pivotal to many research programs aiming at generating new anti-tumor compounds or at screening cDNA libraries. Such approaches need to rely on reproducible, easy-to-handle, and rapid microplate-based cytotoxicity assays that are amenable to high-throughput screening (HTS) technologies. We describe a method for the direct measurement of cell death, based on the detection of a decrease in fluorescence observed following death induction in cells expressing enhanced green fluorescent protein (EGFP). METHODS: Cell death was induced by a variety of apoptotic stimuli in various EGFP-expressing mammalian cell lines, including those routinely used in anti-cancer drug screening. Decrease in fluorescence was assessed either by flow cytometry (and compared with other apoptotic markers) or by a fluorescence microplate reader. RESULTS: Cells expressing EGFP exhibited a decrease in fluorescence when treated by various agents, such as chemotherapeutic drugs, UV irradiation, or caspase-independent cell death inducers. Kinetics and sensitivity of this EGFP-based assay were comparable to those of traditional apoptosis markers such as annexin-V binding, propidium iodide incorporation, or reactive oxygen species production. We also show that the decrease in EGFP fluorescence is directly quantifiable in a fluorescence-based microplate assay. Furthermore, analysis of EGFP protein content in cells undergoing cell death demonstrates that the decrease in fluorescence does not arise from degradation of the protein. CONCLUSIONS: This novel GFP-based microplate assay combines sensitivity and rapidity, is easily amenable to HTS setups, making it an assay of choice for cytotoxicity evaluation.  相似文献   

7.
Aberrant regulation of phosphoinositide 3-kinase (PI3K) activity is implicated in various diseases such as cancer and diabetes. Thus, high-throughput screening (HTS) of small-molecule inhibitors for PI3 kinases is an appealing strategy for drug development. Despite the attractiveness of lipid kinases as drug targets, screening for inhibitors for PI3K activities has been hampered by limited assay formats adaptable for HTS. The authors describe a homogeneous, direct, and nonradioactive assay for highly sensitive detection of PI3Kalpha, beta, delta, and gamma activities, which is suitable for HTS. The assay is based on fluorescence superquenching of a conjugated polymer upon metal-ion-mediated association of phosphorylated and dye-labeled substrates. As a result of phosphorylation, quencher and polymer are brought into proximity, and fluorescent energy transfer occurs. This event can be monitored as either fluorescence quench of the polymer or as enhanced emission from the quencher. Ratiometric analysis of the wavelengths eliminates interferences from autofluorescing compounds, which are present in HTS libraries. The platform has been adapted for the 384-well microplate format and delivers Z factors of > 0.6 at substrate conversions as low as 7%. Using this assay platform, several unreported inhibitors and activators of PI3Ks were identified in an 84- compound screen.  相似文献   

8.
High-throughput screening (HTS) has grown rapidly in the past decade, with many advances in new assay formats, detection technologies, and laboratory automation. Recently, several studies have shown that the choice of assay technology used for the screening process is particularly important and can yield quite different primary screening outcomes. However, because the screening assays in these previous studies were performed in a single-point determination, it is not clear to what extent the difference observed in the screening results between different assay technologies is attributable to inherent assay variability and day-to-day measurement variation. To address this question, a nuclear receptor coactivator recruitment assay was carried out in 2 different assay formats, namely, AlphaScreen and time-resolved fluorescence resonance energy transfer, which probed the same biochemical binding events but with different detection technologies. For each assay format, 4 independent screening runs in a typical HTS setting were completed to evaluate the run-to-run screening variability. These multiple tests with 2 assay formats allow an unambiguous comparison between the discrepancies of different assay formats and the effects of the variability of assay and screening measurements on the screening outcomes. The results provide further support that the choice of assay format or technology is a critical factor in HTS assay development.  相似文献   

9.
Recent developments of single molecule detection techniques and in particular the introduction of fluorescence correlation spectroscopy (FCS) led to a number of important applications in biological research. We present a unique approach for the gene expression analysis using dual-color cross-correlation. The expression assay is based on gene-specific hybridization of two dye-labeled DNA probes to a selected target gene. The counting of the dual-labeled molecules within the solution allows the quantification of the expressed gene copies in absolute numbers. As detection and analysis by FCS can be performed at the level of single molecules, there is no need for any type of amplification. We describe the gene expression assay and present data demonstrating the capacity of this novel technology. In order to prove the gene specificity, we performed experiments with gene-depleted total cDNA. The biological application was demonstrated by quantifying selected high, medium and low abundant genes in cDNA prepared from HL-60 cells.  相似文献   

10.
Fluorescence correlation spectroscopy (FCS) is a fluorescence microscopy technique that allows the study of molecular interactions in extremely low volumes, at nanomolar concentrations, even when binding is not accompanied by a fluorescence change. It can be applied directly in living cells. FCS clearly considerably extends the possibilities of the classical techniques used in molecular recognition studies and can be considered to belong to a growing group of techniques that allow detection at the single molecule level. In this review, several applications of FCS, both in vitro and in vivo, will be discussed.  相似文献   

11.
A simple fluorescence method is reported for the detection of colloidal aggregate formation in solution, with specific applications to determine the critical micelle concentration (CMC) of surfactants and detect small-molecule promiscuous inhibitors. The method exploits the meniscus curvature changes in high-density multiwell plates associated with colloidal changes in solution. The shape of the meniscus has a significant effect on fluorescence intensity when detected using a top-read fluorescence plate reader because of the effect of total internal reflection on fluorescence emission through a curved liquid surface. A dynamic range of 60% is calculated and observed and is measured with a relative sensitivity of 2%. Facile determination of the CMC of a variety of surfactants is demonstrated, as well as a screening assay for aggregate forming properties of small drug-like compounds, a common cause of promiscuous inhibition in high-throughput screening (HTS) enzyme inhibitor assays. Our preliminary results show a potential HTS assay with Z' factor of 0.76, with good separation between aggregating and nonaggregating small molecules. The method combines the high sensitivity and universality of classic surface tension methods with simplicity and high-throughput determination, enabling facile detection of molecular interactions involving a change in liquid or solid surface character.  相似文献   

12.
Frequent hitters are compounds that are detected as a "hit" in multiple high-throughput screening (HTS) assays. Such behavior is specific (e.g., target family related) or unspecific (e.g., reactive compounds) or can result from a combination of such behaviors. Detecting such hits while predicting the underlying reason behind their promiscuous behavior is desirable because it provides valuable information not only about the compounds themselves but also about the assay methodology and target classes at hand. This information can also greatly reduce cost and time during HTS hit profiling. The present study exemplifies how to mine large HTS data repositories, such as the one at Boehringer Ingelheim, to identify frequent hitters, gain further insights into the causes of promiscuous behavior, and generate models for predicting promiscuous compounds. Applications of this approach are demonstrated using two recent large-scale HTS assays. The authors believe this analysis and its concrete applications are valuable tools for streamlining and accelerating decision-making processes during the course of hit discovery.  相似文献   

13.
Necrotic cell death is prevalent in many different pathological disease states and in traumatic injury. Necroptosis is a form of necrosis that stems from specific signaling pathways, with the key regulator being receptor interacting protein 1 (RIP1), a serine/threonine kinase. Specific inhibitors of RIP1, termed necrostatins, are potent inhibitors of necroptosis. Necrostatins are structurally distinct from one another yet still possess the ability to inhibit RIP1 kinase activity. To further understand the differences in the binding of the various necrostatins to RIP1 and to develop a robust high-throughput screening (HTS) assay, which can be used to identify new classes of RIP1 inhibitors, we synthesized fluorescein derivatives of Necrostatin-1 (Nec-1) and Nec-3. These compounds were used to establish a fluorescence polarization (FP) assay to directly measure the binding of necrostatins to RIP1 kinase. The fluorescein-labeled compounds are well suited for HTS because the assays have a dimethyl sulfoxide (DMSO) tolerance up to 5% and Z' scores of 0.62 (fluorescein-Nec-1) and 0.57 (fluorescein-Nec-3). In addition, results obtained from the FP assays and ligand docking studies provide insights into the putative binding sites of Nec-1, Nec-3, and Nec-4.  相似文献   

14.
15.
Protein aggregation is an essential molecular event in a wide variety of biological situations, and is a causal factor in several degenerative diseases. The aggregation of proteins also frequently hampers structural biological analyses, such as solution NMR studies. Therefore, precise detection and characterization of protein aggregation are of crucial importance for various research fields. In this study, we demonstrate that fluorescence correlation spectroscopy (FCS) using a single‐molecule fluorescence detection system enables the detection of otherwise invisible aggregation of proteins at higher protein concentrations, which are suitable for structural biological experiments, and consumes relatively small amounts of protein over a short measurement time. Furthermore, utilizing FCS, we established a method for high‐throughput screening of protein aggregation and optimal solution conditions for structural biological experiments.  相似文献   

16.
This protocol describes assay development, validation and implementation of automated immobilized metal affinity for phosphochemicals (IMAP)-based fluorescence polarization (FP) and time-resolved fluorescence resonance energy transfer (TR-FRET) high-throughput screening (HTS) assays for identification of low-molecular-weight kinase inhibitors. Both procedures are performed in miniaturized kinase reaction volumes and involve the stepwise addition of test or control compounds, enzyme and substrate/ATP. Kinase reactions are stopped by subsequent addition of IMAP-binding buffer. Assay attributes of the IMAP FP and TR-FRET methodologies are described. HTS assays developed using these procedures should result in Z-factors and low assay variability necessary for robust HTS assays. Providing that the required reagents and equipment are available, one scientist should be able to develop a 384-well, miniaturized HTS assay in approximately 6-8 weeks. Specific automated HTS assay conditions will determine the number of assay plates processed in a screening session, but two scientists should expect to process between 100 and 150 assay plates in one 8-h screening day.  相似文献   

17.
In today's high-throughput screening (HTS) environment, an increasing number of assay detection technologies are routinely utilized in lead finding programs. Because of the relatively broad applicability of several of these technologies, one is often faced with a choice of which technology to utilize for a specific assay. The aim of this study was to address the question of whether the same compounds would be identified from screening a set of samples in three different versions of an HTS assay. Here, three different versions of a tyrosine kinase assay were established using scintillation proximity assay (SPA), homogeneous time-resolved fluorescence resonance energy transfer (HTR-FRET), and fluorescence polarization (FP) technologies. In this study, 30,000 compounds were evaluated in each version of the kinase assay in primary screening, deconvolution, and dose-response experiments. From this effort, there was only a small degree of overlap of active compounds identified subsequent to the deconvolution experiment. When all active compounds were then profiled in all three assays, 100 and 101 active compounds were identified in the HTR-FRET and FP assays, respectively. In contrast, 40 compounds were identified in the SPA version of the kinase assay, whereas all of these compounds were detected in the HTR-FRET assay only 35 were active in the FP assay. Although there was good correlation between the IC(50) values obtained in the HTR-FRET and FP assays, poor correlations were obtained with the IC(50) values obtained in the SPA assay. These findings suggest that significant differences can be observed from HTS depending on the assay technology that is utilized, particularly in assays with high hit rates.  相似文献   

18.
Reporter-based assays underlie many high-throughput screening (HTS) platforms, but most are limited to in vitro applications. Here, we report a simple whole-organism HTS method for quantifying changes in reporter intensity in individual zebrafish over time termed, Automated Reporter Quantification in vivo (ARQiv). ARQiv differs from current "high-content" (e.g., confocal imaging-based) whole-organism screening technologies by providing a purely quantitative data acquisition approach that affords marked improvements in throughput. ARQiv uses a fluorescence microplate reader with specific detection functionalities necessary for robust quantification of reporter signals in vivo. This approach is: 1) Rapid; achieving true HTS capacities (i.e., >50,000 units per day), 2) Reproducible; attaining HTS-compatible assay quality (i.e., Z'-factors of ≥0.5), and 3) Flexible; amenable to nearly any reporter-based assay in zebrafish embryos, larvae, or juveniles. ARQiv is used here to quantify changes in: 1) Cell number; loss and regeneration of two different fluorescently tagged cell types (pancreatic beta cells and rod photoreceptors), 2) Cell signaling; relative activity of a transgenic Notch-signaling reporter, and 3) Cell metabolism; accumulation of reactive oxygen species. In summary, ARQiv is a versatile and readily accessible approach facilitating evaluation of genetic and/or chemical manipulations in living zebrafish that complements current "high-content" whole-organism screening methods by providing a first-tier in vivo HTS drug discovery platform.  相似文献   

19.
Dynamics of fluorescence marker concentration as a probe of mobility.   总被引:46,自引:4,他引:42       下载免费PDF全文
We have developed an effective experimental system for the characterization of molecular and structural mobility. It incorporates a modified fluorescence microscope geometry and a variety of analytical techniques to measure effective diffusion coefficients ranging over almost six orders of magnitude, from less than 10(-11) cm2/s to greater than 10(-6) cm2/s. Two principal techniques, fluorescence correlation spectroscopy (FCS) and fluorescence photobleaching recovery (FPR), are employed. In the FPR technique, translational transport rates are measured by monitoring the evolution of a spatial inhomogeneity of fluorescence that is produced photochemically in a microscopic volume by a short burst of intense laser radiation. In contrast, FCS uses laser-induced fluorescence to probe the spontaneous concentration fluctuations in microscopic sample volumes. The kinetics are analyzed by computing time-correlation functions of the stochastic fluctuations of the measured fluorescence intensity. The optical system and digital photocount correlator designed around a dedicated minicomputer are described and discussed. The general power of these techniques is demonstrated with examples from studies conducted on bulk solutions, lipid bilayer membranes, and mammalian cell plasma membranes.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号