首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A column-switching high-performance liquid chromatographic assay is described for the determination of ceftazidime (a third-generation cephalosporin) in human serum. The method does not require prior sample pretreatment. Serum is directly injected in a first chromatographic column for sample clean-up and extraction. Thereafter, using an on-line column-switching system, the drug is quantitatively transferred and separated on a second, analytical column followed by determination using ultraviolet absorption at 258 nm. The technique allows direct, rapid, precise, and simple determination of ceftazidime in serum over the range of 1–250 μg/ml using 12.5 μl of serum. This method was applied to study the pharmacokinetics of the drug in patients undergoing vascular surgery.  相似文献   

2.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase HPLC procedure for the assay of alinastina (pINN) in biological fluids is reported. The effects of the sample pH, composition of the washing and elution solvents and the nature of the SPE cartridge on recovery were evaluated. The selectivity of SPE was examined using spiked rat urine and plasma samples and the CH and PH cartridges gave rise to the cleanest extracts. The recoveries obtained in spiked rat urine and plasma samples were 91.2±2.7 and 99.9±2.8%, respectively. The proposed SPE method coupled off-line with a reserved-phase HPLC system with fluorimetric detection was applied to the quantitation of alinastine in real rat urine samples. The analytical method was also applied and validated for the determination of alinastine in dog plasma. The recovery from spiked dog plasma samples using the PH cartridge was around 65%. The within-day and between-day precisions were 7 and 12%, respectively. The detection and quantitation limits in dog plasma were 0.024 and 0.078 μg/ml, respectively.  相似文献   

3.
A novel solid-phase extraction (SPE) method and HPLC method were developed for the determination of methadone and its metabolite from spiked human urine. For sample cleanup, a spiked urine sample was pretreated with phosphoric acid followed by a well-thought-out SPE method using a 10-mg Oasis HLB 96-well extraction plate. In this SPE method, the concentration of methanol as well as the pH are optimized to preferentially isolate the analytes of interest from the sample matrix. Low elution volumes (200 μl) are achieved; this eliminates evaporation and reconstitution of the sample solution. Recoveries from human urine matrix were greater than 91% with RSD values less than 4.5%. For the HPLC analysis, the separation was obtained using a SymmetryShield RP18 column with a mobile phase of 0.1% TFA–methanol (60:40, v/v). Good peak shapes were obtained without the need of addition of any competing reagent to the mobile phase. Additionally, significant signal-to-noise enrichment was achieved by diluting the final SPE eluates four-fold with water.  相似文献   

4.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

5.
Local transcutaneous delivery of non-steroidal anti-inflammatory drugs avoids gastrointestinal side effects and concentrates drugs in the intended tissues. An extraction and HPLC method was developed for ketoprofen in skin, fascia and muscle. Tissue samples were homogenized in NaHCO3. After methylene chloride removal of lipids, the aqueous layer was acidified with HCl and back extracted into isooctane/isopropanol. Ketoprofen was derivatized with ethylchloroformate/S-(−)-α-phenylethylamine in triethylamine, then detected by HPLC. Ketoprofen recovery was linear (1–33 μg/g) and was detected in these tissues following in vivo cathodic iontophoresis (160 mA*min). This represents the first non-radioactive method for determination of ketoprofen in tissues following transcutaneous iontophoresis.  相似文献   

6.
An improved, more efficient method for the determination of metoprolol and its two metabolites in human urine is reported. The simultaneous analysis of the zwitterionic metoprolol acidic metabolite (III, H117/04) with the basic metabolites α-hydroxymetoprolol (II, H119/66), metoprolol (I) and guanoxan (IV, internal standard) was achieved employing solid-phase extraction and isocratic reversed-phase HPLC. The analytes were extracted from urine (100 μl) using C18 solid-phase extraction cartridges (100 mg), and eluted with aqueous acetic acid (0.1%, v/v)–methanol mixture (40:60, v/v, 1.2 ml). The eluents were concentrated (250 μl) under vacuum, and aliquots (100 μl) were analysed by HPLC with fluorescence detection at 229 nm (excitation) and 309 nm (emission) using simple isocratic reversed-phase HPLC (Novapak C18 radial compression cartridge, 4 μm, 100×5 mm I.D.). Acetonitrile–methanol–TEA/phosphate buffer pH 3.0 (9:1:90, v/v) was employed as the eluent (1.4 ml/min). All components were fully resolved within 18 min, and the calibration curves for the individual analytes were linear (r2≥0.996) within the concentration range of 0.25–40.0 mg/ml. Recoveries for all four analytes were greater than 76% (n=4). The assay method was validated with intra-day and inter-day variations less than 2.5%.  相似文献   

7.
8.
Naringenin and hesperetin, the aglycones of the flavanone glucosides naringin and hesperidin occur naturally in citrus fruits. They exert a variety of pharmacological effects such as antioxidant, blood lipid-lowering, anticarcinogenic and inhibit selected cytochrome P-450 enzymes resulting in drug interactions. A specific, sensitive, precise, and accurate solid-phase extraction high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of naringenin and hesperetin in human plasma was developed and validated. After addition of 7-ethoxycoumarin as internal standard, plasma samples were incubated with beta-glucuronidase/sulphatase, and the analytes were isolated from plasma by solid-phase extraction using C(18) cartridges and separated on a C(8) reversed phase column with methanol/water/acetic acid (40:58:2, v/v/v) as the eluent at 45 degrees C. The method was linear in the 10-300 ng/ml concentration range for both naringenin and hesperetin (r>0.999). Recovery for naringenin, hesperetin and internal standard was greater than 76.7%. Intra- and inter-day precision for naringenin ranged from 1.4 to 4.2% and from 1.9 to 5.2%, respectively, and for hesperetin ranged from 1.3 to 4.1% and from 1.7 to 5.1%, respectively. Accuracy was better than 91.5 and 91.3% for naringenin and hesperetin, respectively.  相似文献   

9.
A novel high-performance liquid chromatographic (HPLC) method for the quantification of diclofenac in human plasma was set up. Samples, added with ibuprofen (used as internal standard) were purified by solid-phase extraction using Abselut Nexus cartridges (Varian) not requiring pre-conditioning. Drugs of interest were eluted directly into the autosampler vials and injected. The recovery of diclofenac was 92%, the analysis lasted 7 min with a sensitivity of 5 ng/ml and intra- and inter-day RSDs of 3 and 8%, respectively. The pharmacokinetics of diclofenac after oral and rectal administration in 10 healthy volunteers are reported.  相似文献   

10.
A 0.5-ml aliquot of a serum sample, after the addition of a 100-μl aliquot of a 5 μg/ml solution of dibucaine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifuged. The supernatant is applied to a 1-ml BondElut C18 silica extraction column conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid—methanol (1:40, v/v). A 7-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 10 mM phosphate buffer-acetonitrile (2:1, v/v) (pH 3.2). The peaks are detected with a fluorescence detector (excitation at 295 nm, emission at 365 nm). The resulting chromatogram is clean with no extraneous peaks. Paroxetine and dibucaine give sharp peaks which are well separated from each other and from the solvent peaks. The extraction recovery of the drug and the internal standard is in the range of 90% which allows a highly sensitive determination of paroxetine.  相似文献   

11.
A new high-performance liquid chromatographic method for simultaneous determination of primidone (PRM) and of its three major metabolites, phenobarbital (PB), p-hydroxyphenobarbital (p-HO-PB) and phenylethylmalonamide (PEMA), in rat urine, was developed. After acid hydrolysis, these compounds were extracted from urine by means of a Bond Elut Certify LRC column with good clean-up. The extracts were chromatographed on a C18 reversed-phase column using isocratic elution at 40°C, with UV detection at 227 nm. The limit of detection was 0.5 mg/ml for the four compounds. Good linearity (r2>0.99) was observed within the calibration ranges studied: 37.4–299.3 μg/ml for PRM, 26.4–211.2 μg/ml for PB, 12.5–100.2 μg/ml for p-HO-PB and 12.1–97.0 μg/ml for PEMA. Repeatability was in the range 3.1–6.8%. This method constitutes a useful tool for studies on the influence of various parameters on primidone metabolism.  相似文献   

12.
In this study, a method for partly automated sample preparation and fully automated solid-phase extraction method for plasma, kidney and liver samples for various retinoids like all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid, retinol and retinyl palmitate was established. Plasma, embryo-, kidney-and liver-homogenates were automatically mixed and extracted on multiple usage solid-phase (C2) extraction cartridges immediately before HPLC analysis. Automated cleaning, preconditioning and incorporation of the loaded cartridge to fully automated HPLC separation and quantification of the various retinoids in a single HPLC run was established. The recovery of the retinoids was generally between 80 and 90%. Intra-day repeatability was < 11.7%. As little as 1.2 ng/ml could be quantified in lipid-mixture standard samples. This method allows a highly automated sample preparation and a fully automated solid-phase extraction with good selectivity for the study of endogenous retinoids and retinoids after nutritional supplementations and pharmacological applications in several biological samples.  相似文献   

13.
Different extraction methods of nucleotides from the yeast Saccharomyces cerevisiae were compared. A new extraction solution--formic acid saturated with 1-butanol--was found to be more effective than the commonly used solutions of trichloroacetic acid, perchloric acid, or formic acid alone. Using this solution the optimal extraction conditions were established. Nucleotide recovery was evaluated by adding standard nucleotides to the extraction medium and carrying them together with the cells through the whole extraction procedure. Nucleotides were separated and quantitated by high-performance liquid chromatography on an anion-exchange column.  相似文献   

14.
15.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic method is reported for the analysis of sulphur mustard in blood with the aid of solid-phase extraction sample preparation. Sulphur mustard is extracted from blood samples (both in vitro and in vivo) of rats with a solution of 0.05 M sodium dodecyl sulphate and pre-concentrated over Sep-Pak C18cartridges pre-coated with Tween-20. A Polygosil C18 column is used with acetonitrile—water (52:48, v/v) as mobile phase for separation and sulphur mustard was detected at 200 nm.  相似文献   

17.
An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250×4.6 mm I.D., 5 μm particle size). The mobile phases were acetonitrile–0.1 M ammonium acetate–acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile–0.1 M ammonium acetate–triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.  相似文献   

18.
A rapid and specific method for the determination of iodide in urine by high-performance liquid chromatography on an anion-exchange column with electrochemical detection is described. The assay is reproducible as judged by the coefficient of variation of less than 4% at all concentrations used. The limit of detection was 0.1 μ mol, and the calibration graph was linear for concentrations between 0.1 and 200 μmol. Using this method, healthy volunteers were found to excrete 69±39 μmol of iodide per mole of creatinine.  相似文献   

19.
The biomedically and neurochemically important compounds 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) have been simultaneously determined in human urine after reverse-phase two-dimensional high-performance liquid chromatography. A 10-fold-diluted urine sample (20 microliters) is first separated on a C18 column (30 X 0.39 cm) using an 85% pH 6.0 phosphate buffer/15% methanol solvent system. The elution volume containing both 5-HIAA and HVA (Rt approximately 3 min) is collected. Recoveries (mean +/- SD) for this purification step, which is monitored using fluorometric detection, were usually above 90%. After acidification of the approximately 2 ml collected fraction, 100 microliters is reinjected on a C18 column and separated (Rt: 5-HIAA, 4 min; HVA 5.5 min) using an 80% pH 3.5 phosphate buffer/20% methanol mobile phase. The compounds are determined by flow-through amperometry with absolute detection limits of approximately 25 pg. Both 5-HIAA and HVA are well resolved from other electroactive species present and are easily determined at normal and greatly reduced concentrations in human urine.  相似文献   

20.
A 0.5-ml aliquot of a serum sample, after the addition of a 50-μl aliquot of a 5 μg/ml solution of amoxapine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifugated. The supernatant is applied to a 1-ml BondElut C18 silica extraction column-conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid-methanol (1:100, v/v). A 15-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 0.1% tetramethylammonium perchlorate-acetonitrile (73:27, v/v) adjusted to pH 4.2 with 10% perchloric acid. The peaks are detected with an absorbance detector at 245 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号