首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
Electric fields, which are ubiquitous in the context of neurons, are induced either by external electromagnetic fields or by endogenous electric activities. Clinical evidences point out that magnetic stimulation can induce an electric field that modulates rhythmic activity of special brain tissue, which are associated with most brain functions, including normal and pathological physiological mechanisms. Recently, the studies about the relationship between clinical treatment for psychiatric disorders and magnetic stimulation have been investigated extensively. However, further development of these techniques is limited due to the lack of understanding of the underlying mechanisms supporting the interaction between the electric field induced by magnetic stimulus and brain tissue. In this paper, the effects of steady DC electric field induced by magnetic stimulation on the coherence of an interneuronal network are investigated. Different behaviors have been observed in the network with different topologies (i.e., random and small-world network, modular network). It is found that the coherence displays a peak or a plateau when the induced electric field varies between the parameter range we defined. The coherence of the neuronal systems depends extensively on the network structure and parameters. All these parameters play a key role in determining the range for the induced electric field to synchronize network activities. The presented results could have important implications for the scientific theoretical studies regarding the effects of magnetic stimulation on human brain.  相似文献   

3.
We suggest an experimental comparison of two directions for applying the time-varying magnetic fields which have been found to speed spontaneous regeneration of injured peripheral nerves and in attempts to repair spinal cord injuries. Time-varying magnetic fields induce currents in a plane perpendicular to the magnetic field direction. The lower conductivity of the spinal cord's sheath (dura matter) or of the myelin sheath of peripheral nerves would seem to confine the induced electric fields and currents to the spinal cord or nerve itself. The proposed comparison could allow choosing between two possible modes of action of the fields: (1) Magnetically-induced electric fields or currents may be encouraging ion flow or otherwise helping enzyme, channel or other interactions at the cell membrane, as is thought to be the case in field stimulation of healing in bone. This mechanism should be independent of field direction. (2) Work in developing organisms and with fields applied to nerve cells in vitro has shown that neurite growth is guided parallel to both endogenous and external electric fields. This mechanism would be effective when induced electric fields are parallel, but not when they are perpendicular to the nerve. Any experimental test should seek to produce as close as possible to the same induced current intensity with both field directions. Possible confounding factors, as well as breakdowns in the assumptions of the simple model presented here, would have to be considered. This proposal was motivated by a recent report in which the authors listed a changed field direction as one of several possible reasons for an unsuccessful experiment.  相似文献   

4.
The goal of the research reported here is to narrow the range of uncertainty about peripheral nerve stimulation (PNS) thresholds associated with whole body magnetic field exposures at 50/60 Hz. This involved combining PNS thresholds measured in human subjects exposed to pulsed magnetic gradient fields with calculations of electric fields induced in detailed anatomical models of the body by that same exposure system. PNS thresholds at power frequencies (50/60 Hz) can be predicted from these data due to the wide range of pulse durations (70 mus to 1 ms), the length of the pulse trains (several tens of ms), and the exposure of a large part of the body to the magnetic field. These data together with the calculations of the rheobase electric field exceeded in 1% (E(1%)) of two anatomical body models, lead to a median PNS detection threshold of 47.9 +/- 4.4 mT for a uniform 60 Hz magnetic field exposure coronal to the body. The threshold for the most sensitive 1% of the population is about 27.8 mT. These values are lower than PNS thresholds produced by magnetic fields with sagittal and vertical orientations or nonuniform exposures.  相似文献   

5.
Surface magnetic and electric recordings were used to localize the sources of late pain-related magnetic fields and electric potentials, evoked by painful intracutaneous electric finger stimulation. We find that the source of the P90m component of the evoked magnetic field lies in the finger area of the primary somatosensory cortex; the sources of the N150m and P250m are found to reside in the frontal operculum. These findings are unexpected from the evoked electric potential data, which suggest a central location for these sources. We also note that the interpretation of the electric data was confounded by the presence of an alpha-like oscillation, which overlapped many components of the evoked potential.  相似文献   

6.
This study tests the capacity of 50 Hz magnetic and electric fields to stimulate neurite outgrowth in PC-12D cells, a cell line which originated from a pheochromocytoma in rat adrenal medulla. The cells were plated on collagen-coated, plastic petri dishes and exposed to sinusoidal 50 Hz magnetic fields for 22 h in a 5% CO2 incubator at 37°C. Two 1,000 turn coils, 20 cm in diameter, were assembled in a Helmholtz configuration to generate a magnetic field in a vertical orientation, thereby inducing a companion electric field in the dish with intensity proportional to radius. A magnetic-field shield housed the control samples in the same incubator. Total cells and number of cells with neurites at least as long as one cell diameter or having a growth cone were counted within a radius of 0.3 cm of the dish center and within an annulus of 1.7–1.8 cm radii in 60 mm dishes, at 3.6 cm radius in 100 mm dishes, and between 1.9 and 2.1 cm radii in the outer well of organ culture dishes, which are physically separated into two concentric wells. Sham exposure demonstrated no difference in percentage of cells with neurites between the exposed and control locations in the incubator. Exposures were done at 4.0. 8.9, 22, 29, 40, 120, 236, and 400 milliGauss (mG). At dish radii of 1.7–1.8 cm in the 60 mm dishes these magnetic flux densities induced electric fields of 1.1, 2.5, 5.9, 8.1, 11, 33, 65, and 110 μV/m, respectively, while within a radius of 0.3 cm, the induced electric fields were less than 0.2, 0.4, 1.0, 1.5, 1.9, 6.0, 11, and 19 μV/m, respectively. For other dishes, the larger radii produced proportionally larger induced electric fields. At each field strength, there were two control dishes and four to nine exposed dishes: 100 or more cells were counted at each location on the dishes. The results demonstrate that magnetic fields stimulate neurite outgrowth in a flux-density-dependent manner between 22 and 40 mG, reaching an apparent stimulation plateau between 40 and 400 mG; no effects were seen at 8.9 mG or lower. There was no apparent neurite stimulation due to the electric field. Although relatively low intensity (?22mG) magnetic fields alone can stimulate a morphological response in a cell which is normally stimulated by nerve growth factor molecules binding to membrane receptors, the chemical basis of this response is unknown. © 1993 Wiley-Liss. Inc.  相似文献   

7.
A theoretical analysis of electric and magnetic fields of the heart, based solely upon the scalar multipole expansion, is carried out in order to gain an insight into the interrelation of the data contained in electro- and magnetocardiological measurements. The usual multipole expansion is applied for the electric field, however corresp[nding equivalent multipoles are formulated as idealized generators, having not only flow sources, but also vortex sources of the field. Furthermore, the magnetic field in a homogeneous infinite volume conductor is expressed as a sum of two series, the first being the usual multipole expansion of the nonvortex component of the magnetic field, and the second being a sequence of magnetic fields set up by the aforementioned electric multipole generators reduced to axial form. The former term is uniquely defined by the electric multipole components, but the latter reflects properties of the cardiogenerator that can be revealed only by means of magnetic measurements. Features of the electric and magnetic multipole components as integral characteristics of the cardiogenerator are discussed and concepts of the magnetic centre and magnetic axis of the cardiogenerator are proposed. The analysis is illustrated by examples of simple generator configurations.  相似文献   

8.
Limits on exposures to extremely low-frequency electric fields, magnetic fields and contact currents, designated as voluntary guidelines or standards by several organizations worldwide, are specified so as to minimize the possibility of neural stimulation. The limits, which we refer to as guidelines, derive from "basic restrictions" either on electric fields or current density within tissue, or on avoidance of annoying or startling interactions that may be experienced with spark discharge or contact current. Further, the guidelines specify more conservative permissible doses and exposure levels for the general public than for exposures in controlled environments, which most typically involve occupational settings. In 2001 we published an update on guideline science. This paper covers more recent developments that are relevant to the formulation and implementation of the next generation of guidelines. The paper deals with neurostimulation thresholds and the relevance of magnetophosphenes to setting guideline levels; dosimetry associated with contact current benchmarked against basic restrictions; tissue and cellular dosimetry from spark discharge; assessment of exposures to high electric fields in realistic situations (e.g., line worker in a transmission tower); a simplified approach to magnetic field assessment in non-uniform magnetic fields; and a quantitative approach to sampling workplace exposure for assessing compliance.  相似文献   

9.
A system is described that is capable of producing extremely low frequency (ELF) magnetic fields for relatively short-term exposure of cultured mammalian cells. The system utilizes a ferromagnetic core to contain and direct the magnetic field of a 1,000 turn solenoidal coil and can produce a range of flux densities and induced electric fields much higher than those produced by Helmholtz coils. The system can generate magnetic fields from the microtesla (μT) range up to 0.14 T with induced electric field strengths on the order of 1.0 V/m. The induced electric field can be accurately varied by changing the sample chamber configuration without changing the exposure magnetic field. This gives the system the ability to separate the bioeffects of magnetic and induced electric fields. In the frequency range of 4–100 Hz and magnetic flux density range of 0.005–0.14 T, the maximum total harmonic distortion of the induced electric field is typically less than 1.0%. The temperature of the samples is held constant to within 0.4°C by constant perfusion of warmed culture medium through the sample chamber. © 1993 Wiley-Liss, Inc.  相似文献   

10.
Transcranial magnetic stimulation (TMS) is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS) is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS) with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.  相似文献   

11.
Changes in the electrical properties of tissue during healing should affect the electric field and current density distributions produced by applied electric or magnetic fields. The electric field produced at a fracture site by surface electrodes is found using a finite-difference method, implemented with a commerically-available spread-sheet program on a microcomputer. The method is first validated by application to a two-layer cylinder. The model considered is the healing of a tibia fracture in an irregularly-shaped, anisotropic model of the human calf. Variations of the three components of the electric field throughout the calf due to the healing are examined. Significant changes are found at the fracture site and in its vicinity. Similar results should be observed with other forms of electromagnetic stimulation.  相似文献   

12.
Power-frequency electric and magnetic fields are known to exhibit marked temporal variation, yet in the absence of clear biological indications, the most appropriate summary indices for use in epidemiologic studies are unknown. In order to assess the statistical patterns among candidate indices, data on 4383 worker-days for magnetic fields and 2082 worker-days for electric fields collected for the Electric and Magnetic Field Project for Electric Utilities using the EMDEX meter [Bracken (1990): Palo Alto, CA: Electric Power Research Institute] were analyzed. We examined correlations at the individual and job title group levels among indices of exposure to both electric and magnetic fields, including the arithmetic mean, geometric mean, median, 20th and 90th percentiles, time above lower cutoffs of 20 V/m and 0.2 μT, and time above higher cutoffs of 100 V/m and 2.0 μT. For both electric and magnetic fields, the arithmetic mean was highly correlated with the 90th percentile; moderately correlated with the geometric mean, median, and lower and higher cutoff scores; and weakly correlated with the 20th percentile. Electric and magnetic field indices were generally weakly correlated with one another. Rank-order correlation coefficients were consistently greater than product-moment correlation coefficients. Job title group summary scores showed higher correlations among electric field indices and magnetic field indices and between electric and magnetic field indices than was found for individual worker-days, with only the 20th percentile clearly independent of the others. These results suggest that individuals' exposures are adequately characterized by a measure of central tendency for electric and magnetic fields, such as the arithmetic or geometric mean, and an indicator of a lower threshold or cutoff for each field type, such as the 20th percentile or proportion of time above 20 V/m or 0.2 μT. A single measure of central tendency for each type of field appears to be adequate when exposures are assessed at the job title level. © 1994 Wiley-Liss, Inc.  相似文献   

13.
Much of the research and reviews on extremely low frequency (ELF) electric and magnetic fields (EMFs) have focused on magnetic rather than electric fields. Some have considered such focus to be inappropriate and have argued that electric fields should be part of both epidemiologic and laboratory work. This paper fills the gap by systematically and critically reviewing electric‐fields literature and by comparing overall strength of evidence for electric versus magnetic fields. The review of possible mechanisms does not provide any specific basis for focusing on electric fields. While laboratory studies of electric fields are few, they do not indicate that electric fields should be the exposure of interest. The existing epidemiology on residential electric‐field exposures and appliance use does not support the conclusion of adverse health effects from electric‐field exposure. Workers in close proximity to high‐voltage transmission lines or substation equipment can be exposed to high electric fields. While there are sporadic reports of increase in cancer in some occupational studies, these are inconsistent and fraught with methodologic problems. Overall, there seems little basis to suppose there might be a risk for electric fields, and, in contrast to magnetic fields, and with a possible exception of occupational epidemiology, there seems little basis for continued research into electric fields. Bioelectromagnetics 31:89–101, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
Electric fields induced in a conductive body by the magnetic field of a current-carrying wire were analyzed theoretically and experimentally to assess the dosimetric importance of highly nonuniform, field-exposure conditions. Experimentation revealed that a 60-Hz magnetic field was inversely proportional to the radius of a wire bundle carrying 100 A within a 0.5-m2 test area. A miniaturized electric field probe was used to measure the electric fields induced in 5-cm-deep, saline-filled models. In the theoretical analysis, numerical estimates of induced fields were made by a spreadsheet method. The theoretical calculations and the measured values of induced electric fields were generally in good agreement. The induced fields were in a plane perpendicular to a vertically incident magnetic field; the maximally induced fields were in areas nearest the wire bundle. The strength of the induced field increased with model size: from 96 microV/cm in a 10 x 10 cm model to 176 microV/cm in a 40 x 40 cm model. The strength of the field induced in a 20 x 20 cm model decreased with increasing model-to-wire spacing: from 132 microV/cm for a 1-cm spacing (2-mT maximum, incident field) to 50 microV/cm for a 6-cm spacing (0.33-mT maximum). The results indicate that increases in local values of nonuniformly incident fields produce relatively small increases in induced electric fields. This finding may be important in dosimetric consideration of circumstances, such as use of electric blankets, in which fields of low average strength are accompanied by intense local fields.  相似文献   

15.
We prove that, at the frequencies generally proposed for extracranial stimulation of the brain, it is not possible, using any superposition of external current sources, to produce a three-dimensional local maximum of the electric field strength inside the brain. The maximum always occurs on a boundary where the conductivity jumps in value. Nevertheless, it may be possible to achieve greater two-dimensional focusing and shaping of the electric field than is currently available. Towards this goal we have used the reciprocity theorem to present a uniform treatment of the electric field inside a conducting medium produced by a variety of sources: an external magnetic dipole (current loop), an external electric dipole (linear antenna), and surface and depth electrodes. This formulation makes use of the lead fields from magneto- and electroencephalography. For the special case of a system with spherically symmetric conductivity, we derive a simple analytic formula for the electric field due to an external magnetic dipole. This formula is independent of the conductivity profile and therefore embraces spherical models with any number of shells. This explains the "insensitivity" to the skull's conductivity that has been described in numerical studies. We also present analytic formulas for the electric field due to an electric dipole, and also surface and depth electrodes, for the case of a sphere of constant conductivity.  相似文献   

16.
The goal of this paper is to examine the origins and relative importance of primary and secondary sources of electric and magnetic fields for excitable tissue. It is shown that for axonal and cardiac tissue a comparison of the relative field strength from both primary and secondary sources shows only the latter to be significant. Even if the divergence and curl of the primary source were independent (and hence were both needed to define the primary source), because the secondary sources all arise from the divergence of the primary source the magnetic field reflects the same source component as the electric field. As a consequence magnetic and electric fields arising from active tissue are strongly linked.  相似文献   

17.
Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32–95 Hz. When the rats were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface (where induced fields were maximal). Within the body, or in different directions relative to the applied field, the induced fields were reduced (reaching zero at the center of the animal). The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals. Bioelectromagnetics 18:317–323, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

18.
Electric fields induced by low-frequency magnetic fields into inhomogeneous structures, which have electric conductivities and dielectric permittivities of typical biological substances, are evaluated. Closed-form approximate and numerical solutions are obtained for nonconcentric cylinders with different electric properties (such as bone embedded in muscle), which are surrounded by a good electrical insulator (such as air). It is shown that even a single inhomogeneity in an otherwise homogenous cylinder, which is exposed to a uniform, axially directed magnetic field, can lead to substantial deviations from the direction and distribution of the induced electric field that would exist in the homogenous cylinder. Thus the induced field is not everywhere circumferential, nor does it magnitude at all angular positions increase linearly with the radial distance. Radially and circumferentially directed field components depend on size, electrical properties, and eccentricity of the inhomogeneities. Equations as well as graphical presentations are given that describe the induced fields when the enclosed inhomogeneities consist either of eccentrically located single cylinders or pairs of coaxial cylinders with different electrical conductivities or dielectric permittivities.  相似文献   

19.
AimAiming at analysing the signal conduction in muscular fibres, the spatio-temporal dynamics of the magnetic field generated by the propagating muscle action potential (MAP) is studied.MethodIn this prospective, proof of principle study, the magnetic activity of the intrinsic foot muscle after electric stimulation of the tibial nerve was measured using optically pumped magnetometers (OPMs). A classical biophysical electric dipole model of the propagating MAP was implemented to model the source of the data. In order to account for radial currents of the muscular tubules system, a magnetic dipole oriented along the direction of the muscle was added.ResultsThe signal profile generated by the activity of the intrinsic foot muscles was measured by four OPM devices. Three OPM sensors captured the spatio-temporal magnetic field pattern of the longitudinal intrinsic foot muscles. Changes of the activation pattern reflected the propagating muscular action potential along the muscle. A combined electric and magnetic dipole model could explain the recorded magnetic activity.InterpretationOPM devices allow for a new, non-invasive way to study MAP patterns. Since magnetic fields are less altered by the tissue surrounding the dipole source compared to electric activity, a precise analysis of the spatial characteristics and temporal dynamics of the MAP is possible. The classic electric dipole model explains major but not all aspects of the magnetic field. The field has longitudinal components generated by intrinsic structures of the muscle fibre. By understanding these magnetic components, new methods could be developed to analyse the muscular signal transduction pathway in greater detail. The approach has the potential to become a promising diagnostic tool in peripheral neurological motor impairments.  相似文献   

20.
Equipment designed for simultaneous exposure of rodents to 60-Hz electric and magnetic fields is described. Three identical systems were constructed, each capable of continuous exposure of 256 rats or 640 mice to a nominal electric field at less than 50 kV/m, and to horizontal and vertical magnetic fields at less than 1 mT. Design features, construction details, and results of various tests of the systems are described. Tests were made: of phase relations between electric and magnetic fields; of uniformity of electric and magnetic fields; of changes across time in electric-field intensity as a result of animals' soiling of cages and various washing routines; of resistance of bedding material during humid and dry conditions; and of acoustic noise due to background, to field-generation equipment, and to air conditioning equipment. The results demonstrated that fields were effectively generated but that significant and troublesome changes in electric-field intensity occurred because of cage-soiling. However, when cages were frequently cleaned, field intensities were consistent from one exposure to another.  相似文献   