首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A system which consisted of multidimensional liquid chromatography (Yin-yang MDLC) coupled with mass spectrometry was used for the identification of peptides and phosphopeptides. The multidimensional liquid chromatography combines the strong-cation exchange (SCX), strong-anion exchange (SAX), and reverse-phase methods for the separation. Protein digests were first loaded on an SCX column. The flow-through peptides from SCX were collected and further loaded on an SAX column. Both columns were eluted by offline pH steps, and the collected fractions were identified by reverse-phase liquid chromatography tandem mass spectrometry. Comprehensive peptide identification was achieved by the Yin-yang MDLC-MS/MS for a 1 mg mouse liver. In total, 14 105 unique peptides were identified with high confidence, including 13 256 unmodified peptides and 849 phosphopeptides with 809 phosphorylated sites. The SCX and SAX in the Yin-Yang system displayed complementary features of binding and separation for peptides. When coupled with reverse-phase liquid chromatography mass spectrometry, the SAX-based method can detect more extremely acidic (pI < 4.0) and phosphorylated peptides, while the SCX-based method detects more relatively basic peptides (pI > 4.0). In total, 134 groups of phosphorylated peptide isoforms were obtained, with common peptide sequences but different phosphorylated states. This unbiased profiling of protein expression and phosphorylation provides a powerful approach to probe protein dynamics, without using any prefractionation and chemical derivation.  相似文献   

2.
A new fast method for identification and characterization of proteolytic digests of proteins by monolithic liquid chromatography coupled with mass spectrometry has been developed. The advantages of the monolithic columns are a high-pressure stability and low back pressure resulting in higher flow rates for capillary or nanosize columns simplifying the system handling. As was shown in several publications, such monolithic stationary phases are highly qualified for the analysis of peptides and proteins, but so far, only small volumes could be injected into the system, which might hamper the sample preparation leading to protein precipitation and partial loss of sample. To overcome the problem of small injection volumes, we established a system including a short monolithic trap column to allow preconcentration of the peptides. The injected sample is flushed at higher flow rates onto the trap column, bound to the stationary phase, and in this way concentrated in a few nanoliters before starting the separation. The expanded system was optimized and tested using different reference protein samples. Eluting peptides were detected by MALDI-TOF/TOF-MS and identified by database searching. The system is now a permanent part for proteome analysis in our lab, and as such, it was successfully applied for the detection of post-translational modifications and the analysis of membrane proteins. One example for these analyses is also included in this paper.  相似文献   

3.
A method for the rapid identification of proteins and their N-glycans was developed through the use of two parallel columns directly connected to a mass spectrometer. Both porous graphitic carbon (PGC) and C18 capillary columns were connected in parallel with two switching valves for the simultaneous analysis of glycans and peptides, respectively. To verify the efficiency of the analytical system, profiling of N-glycans and proteins from human serum was demonstrated. This method is suitable for high-throughput analysis and automation, is contamination-free for the identification of N-glycans and proteins in a complex biological sample, and can be applied to glycomics and proteomics.  相似文献   

4.
Two-dimensional liquid-chromatographic (LC) separation followed by mass spectrometric (MS) analysis was examined for the identification of peptides in complex mixtures as an alternative to widely used two-dimensional gel electrophoresis followed by MS analysis for use in proteomics. The present method involves the off-line coupling of a narrow-bore, polymer-based, reversed-phase column using an acetonitrile gradient in an alkaline mobile phase in the first dimension with octadecylsilanized silica (ODS)-based nano-LC/MS in the second dimension. After the first separation, successive fractions were acidified and dried off-line, then loaded on the second dimension column. Both columns separate peptides according to hydrophobicity under different pH conditions, but more peptides were identified than with the conventional technique for shotgun proteomics, that is, the combination of a strong cation exchange column with an ODS column, and the system was robust because no salts were included in the mobile phases. The suitability of the method for proteomics measurements was evaluated.  相似文献   

5.
A comprehensive on-line sample clean-up with an integrated two-dimensional HPLC system was developed for the analysis of natural peptides. Samples comprised of endogenous peptides with molecular weights up to 20 kDa were generated from human hemofiltrate (HF) obtained from patients with chronic renal failure. The (poly-)peptides were separated using novel silica-based restricted access materials with strong cation-exchange functionalities (SCX-RAM). The size-selective sample fractionation step is followed by cation-exchange chromatography as the first dimension. The subsequent second dimension of separation is based on hydrophobic interaction using four parallel short reversed-phase (RP) columns implemented via a fully automated column switching technique. More than 1000 peaks were resolved within the total analysis time of 96 min. Substances of selected peaks were sampled to analyse their molecular weights by off-line MALDI-TOF mass spectrometry and to determine their amino acid sequence by Edman degradation. The potential for comprehensive peptide mapping and identification is demonstrated.  相似文献   

6.
Lu CY  Wu CY  Lin CH 《Analytical biochemistry》2007,368(2):123-129
In typical mass spectrometry-based protein identification using peptide fragmentation fingerprinting, front-end separation plays a critical role in successful peptide sequencing. This separation step demands a great deal of time and usually is the rate-limiting step for the whole process. Here we provide an alternative separation method, based on a simple nanoflow delivery system, that is able to shorten the separation time considerably. This system consists of a 25-mul syringe connected to a manually packed reversed-phase mini-capillary column that can be directly coupled to an electrospray ionization tandem mass spectrometer. A syringe pump is then used to deliver the peptide mixtures at a nanoscale flow rate. We examined the efficiency and efficacy of this method by analyzing the tryptic peptides of bovine serum albumin and of 10 Escherichia coli proteins separated by two-dimensional gel electrophoresis (2DE). The results showed that identification of each protein could be achieved successfully within 25 min by using the disposable mini-capillary column. Moreover, all 2DE-separated E. coli proteins were identified at high confidence levels. Together, our data suggest that this method is a suitable option for mass spectrometry-based protein identification.  相似文献   

7.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

8.
In carrying out proteomic researches using mass-spectrometry there often arises a need to compare experimental data with each other (e.g. control of pathology, the labeled to unlabelled samples). If for peptide identification in different experiments one uses only their exact mass measurements and the retention time in the chromatographic column, difficulties with the identification of chromatographic peaks belonging to the same substances in different chromatograms come up (retention time normalization). Due to inevitable discrepancies in chromatographic conditions of experiments (replacement of chromatographic columns, small changes in mobile phase flow rate or solvent concentration) retention times of the same peptides will diverge from experiment to experiment. In this paper we offer a reliable method for selecting peaks from mass-chromatograms corresponding to the same peptides, which can later be used for retention time normalization (either linear or any other monotone function).  相似文献   

9.
Immune complexome analysis is a method for identifying and profiling of antigens in circulating immune complexes (CICs); it involves separation of immune complexes from serum, direct tryptic digestion of these complexes, and protein analysis via nano-liquid chromatography–tandem mass spectrometry (nano-LC–MS/MS). To improve this method, we initially investigated the effects of two factors—the gradient elution program and nano-LC column type (C18-packed, C8-packed, or packed spray capillary column)—on the numbers of peptides and proteins identified. Longer gradient elution times resulted in higher identification capability throughout the range of 25–400 min. Moreover, the packed spray capillary column supported identification of more peptides and proteins than did any other column. In addition, microwave-assisted digestion was compared with conventional digestion, which involved incubation overnight at 37 °C. Microwave-assisted digestion produced more partially digested peptides than did conventional digestion. However, the percentages of miscleaved peptides in all of the identified peptides in microwave-assisted digestion of immune complexes (a protein mixture) were lower than those in the physical stimulation-assisted digestion of a model protein. Microwave-assisted digestion is slightly inferior to, or as effective as, conventional digestion, but it drastically reduces the digestion time.  相似文献   

10.
Evaluation of cellular processes and their changes at the level of protein expression and post-translational modifications may allow identification of novel proteins and the mechanisms involved in pathogenic processes. However, the number of proteins and, after tryptic digestion, of peptides from a single cell can be tremendously high. Separation and analysis of such complex peptide mixtures can be performed using multidimensional separation techniques such as two-dimensional gel electrophoresis or two-dimensional-high-performance liquid chromatography (2-D-HPLC). The aim of this work was to establish a fully automated on-line 2-D-HPLC separation method with column switching for the separation of complex tryptic digests. A model mixture of five proteins as well as a nuclear matrix protein sample were digested with trypsin and separated using a strong cation exchange (SCX) column in the first dimension and nano reversed phase in the second dimension. Separated peptides were detected using an ion trap mass spectrometer. The advantages of this new fully automated method are rapid sample loading, the possibility of injecting large volumes and no introduction of salt into the mass spectrometer. Furthermore, column switching allows the independent control and optimization of the two dimensions independently.  相似文献   

11.
Reversed phase high performance liquid chromatography (HPLC) interfaced to electrospray tandem mass spectrometry (MS/MS) is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average), costly (columns and mobile phase reagents), and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate) based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap) with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes). Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.  相似文献   

12.
Advancement in proteomics research relies on the development of new, innovative tools for identifying and characterizing proteins. Here, we describe a protocol for analyzing peptides and proteins on a chromatographic timescale by coupling nanoflow reverse-phase (RP) liquid chromatography (LC) to electron-transfer dissociation (ETD) mass spectrometry. For this protocol, proteins can be proteolytically digested before ETD analysis, although digestion is not necessary for all applications. Proteins 相似文献   

13.
Mass spectrometry-based neuropeptidomics is one of the most powerful approaches for identification of endogenous neuropeptides in the brain. Until now, however, the identification rate of neuropeptides in neuropeptidomics is relatively low and this severely restricts insights into their biological function. In the present study, we developed a high accuracy mass spectrometry-based approach to enhance the identification rates of neuropeptides from brain tissue. Our integrated approach used mixing on column for loading aqueous and organic extracts to reduce the loss of peptides during sample treatment and used charge state-directed tandem mass spectrometry to increase the number of peptides subjected to high mass accuracy fragmentation. This approach allowed 206 peptides on average to be identified from a single mouse brain sample that was prepared using 15 μL of solutions per 1 mg of tissue. In total, we identified more than 500 endogenous peptides from mouse hypothalamus and whole brain samples. Our identification rate is about two to four times higher compared to previously reported studies conducted on mice or other species. The hydrophobic peptides, such as neuropeptide Y and galanin, could be presented and detected with hydrophilic peptides in the same LC-MS run, allowing a high coverage of peptide characterization over an organism. This will advance our understanding of the roles of diverse peptides and their links in the brain functions.  相似文献   

14.
Reactive monoliths of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) have been prepared by "in-situ" copolymerization of the monomers in the presence of porogenic diluents. Protein A and L-histidine were immobilized on the monoliths directly or through a spacer arm, respectively. The properties of these two kinds of affinity columns were characterized, and the results showed that the columns with coupling of ligands by a spacer arm have some extent of non-specific adsorption for bovine serum albumin. The affinity column based on the monolithic polymer support provided us with good hydrodynamic characteristic, low flow resistance, and easy preparation. These two affinity columns were used for the purification of immunoglobulin G from human serum. The purity of the purified IgG was detected by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The stability of the protein A affinity column was investigated, and its performance remained invariable after half a year. The effects of the nature and the pH of the buffer system on the adsorption capacity of human IgG on histidyl affinity column were also investigated. The protein A affinity column is favorable for rapid analysis of human IgG samples. In contrast, the advantages of mild elution conditions, high stability, as well as low cost provide the histidyl column further potential possibility for fast removal of IgG from human plasma in clinical applications.  相似文献   

15.
We compared trysin-digested protein samples desalted by ZipTip(C18) reverse-phase microcolumns with on-plate washing of peptides deposited either on paraffin-coated plates (PCP), Teflon-based AnchorChip plates, or stainless steel plates, before analysis by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). Trypsinized bovine serum albumin and ovalbumin and 16 protein spots extracted from silver-stained two-dimensional gels of murine C(2)C(12) myoblasts or human leukocytes, prepared by the above two methods, were subjected to MALDI on PCP, AnchorChip plates, or uncoated stainless steel plates. Although most peptide mass peaks were identical regardless of the method of desalting and concentrating of protein samples, samples washed and concentrated by the PCP-based method had peptide peaks that were not seen in the samples prepared using the ZipTip(C18) columns. The mass spectra of peptides desalted and washed on uncoated stainless steel MALDI plates were consistently inferior due to loss of peptides. Some peptides of large molecular masses were apparently lost from samples desalted by ZipTip(C18) microcolumns, thus diminishing the quality of the fingerprint needed for protein identification. We demonstrate that the method of washing of protein samples on paraffin-coated plates provides an easy, reproducible, inexpensive, and high-throughput alternative to ZipTip(C18)-based purification of protein prior to MALDI-TOF-MS analysis.  相似文献   

16.
Proteomic workflows involving liquid-based protein separations are an alternative to gel-based protein analysis, however the trypsin digestion procedure is usually difficult to implement, particularly when processing low abundance proteins from capillary column effluent. To convert the protein to peptides for the purpose of identification, current protocols require several sample handling steps, and sample losses become an issue. In this study, we present an improved system that conducts reversed-phase protein chromatography and rapid on-line tryptic digestion requiring sub-nanogram quantities of protein. This system employs a novel mirror-gradient concept that allows for dynamic titration of the column effluent to create optimal conditions for real-time tryptic digestion. The purpose behind this development was to improve the limits of detection of the online concept, to support flow-based alternatives to gel-based proteomics and to simplify the characterization of low abundance proteins. Using test mixtures of proteins, we show that peptide mass fingerprinting with high sequence representation can be easily achieved at the 20 fmol level, with detection limits down to 5 fmol (85 pg myoglobin). Limits of identification using standard data-dependent MS/MS experiments are as low as 10 fmol. These results suggest that the nanoLC-trypsin-MS/MS system could represent an alternative to the conventional "1D-gel to MS" proteomic strategy.  相似文献   

17.
The direct linkage between folded structures of proteins and their function has increased the need for high resolution structures. In addition, there is a need for analytical methods for detecting and locating changes in the folded structures of proteins under a wide variety of conditions. The rates at which hydrogens located at peptide amide linkages undergo isotopic exchange has become the basis for an important method for detecting such structural changes. When detected by mass spectrometry, hydrogen exchange can be used to study dilute solutions of large proteins and protein complexes with very high sensitivity. To locate structural changes, labeled proteins are often digested with acid proteases to form peptides whose hydrogen/deuterium levels are determined by mass spectrometry. This approach is successful only when the protein can be digested rapidly under conditions where isotope exchange is slow. This study describes how columns packed with immobilized pepsin can be used to reduce the digestion time and to provide an effective means for separating the pepsin from the isotopically labeled fragments. These columns are part of an on-line system that facilitates both rapid digestion of low concentrations of protein and concentration of the peptides.  相似文献   

18.
蛋白质组学的基础研究之一是蛋白质鉴定.规模化的蛋白质鉴定通常采用"鸟枪法",即选择一些酶切肽段(母离子)碎裂生成二级谱图,通过二级谱图及其母离子质量鉴定肽段,再推断对应的蛋白质.在鉴定过程中,母离子质量是一个关键参数.母离子是否是肽段的单同位素峰决定了正确肽段是否能进入候选,母离子的质量精度决定了候选肽段的数目.本文从判断单同位素峰和系统误差校准这两个角度研究了母离子的准确检测技术.判断单同位素峰的技术在蛋白质上已有研究,包括电荷判断、单同位素峰判断和重叠同位素峰判断.可以借鉴蛋白质水平的技术研究母离子的单同位素峰判断方法.同时母离子的系统误差校准也有较为成熟的方法.这两个角度的研究有助于提高规模化蛋白质的鉴定率.  相似文献   

19.
Defining membrane proteomes is fundamental to understand the role of membrane proteins in biological processes and to find new targets for drug development. Usually multidimensional chromatography using step or gradient elution is applied for the separation of tryptic peptides of membrane proteins prior to their mass spectrometric analysis. Displacement chromatography (DC) offers several advantages that are helpful for proteome analysis. However, DC has so far been applied for proteomic investigations only in few cases. In this study we therefore applied DC in a multidimensional LC–MS approach for the separation and identification of membrane proteins located in cholesterol-enriched membrane microdomains (lipid rafts) obtained from rat kidney by density gradient centrifugation. The tryptic peptides were separated on a cation-exchange column in the displacement mode with spermine used as displacer. Fractions obtained from DC were analyzed using an HPLC-chip system coupled to an electrospray-ionization ion-trap mass spectrometer. This procedure yielded more than 400 highly significant peptide spectrum matches and led to the identification of more than 140 reliable protein hits within an established rat kidney lipid raft proteome. The majority of identified proteins were membrane proteins. In sum, our results demonstrate that DC is a suitable alternative to gradient elution separations for the identification of proteins via a multidimensional LC–MS approach.  相似文献   

20.
鸟枪法蛋白质鉴定质量控制方法研究进展   总被引:1,自引:0,他引:1  
鸟枪法串联质谱蛋白质鉴定策略由于其高可靠和高效率而被广泛应用于蛋白质组学研究中,这种方法直接对蛋白质混合物进行酶切,以肽段为鉴定单元,继而推导真实的样品蛋白质.由于利用质谱图推导肽段存在一定的假阳性率,而且直接对蛋白质混合物的酶切也导致了肽段和蛋白质之间关联信息的丢失,所鉴定的蛋白质难免存在部分不可靠结果.因此,蛋白质鉴定的质量控制在蛋白质组学研究中极为重要.蛋白质鉴定的质量控制包含两大类主要方法,其一为利用肽段进行蛋白质组装,当前最常用也被证明最有效的方法是使用简约原则,即用最少的蛋白质解释所有鉴定肽段,现有的方法可以分为布尔型和概率型,其二为鉴定蛋白质的可靠性评估,包括单个蛋白质鉴定置信度和蛋白质鉴定整体水平的假阳性率计算.综合各种可辅助蛋白质鉴定的先验信息,构建普适的概率统计模型,是目前蛋白质鉴定质量控制方法的发展趋势.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号